My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1677
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1677
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 12:14:49 PM
Creation date
5/9/2022 12:14:47 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1677
Building Department - Name
WATSON,JOHN & SUE
Address
37946 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FL 7271.8-R4 <br /> C2174-8 <br /> 8.23.2017 <br /> Page 2 of 2 <br /> Manufacturer: Union Corrugating Company <br /> Product Name: MasterRib Panel <br /> Panel Description: 36"wide coverage with 3/4"high ribs at 9" o.c. <br /> Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) <br /> or Galvalume; coated steel (ASTM A792) or painted steel (ASTM <br /> A755). <br /> Deck Description: Min. 19/32" thick APA rated plywood or min. 3/4" thick wood plank <br /> (min SG of 0.42) for new and existing constructions. Designed by <br /> others and installed as per FBC 2017. <br /> Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 <br /> Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 <br /> Design Uplift Pressure: 61.8 psf @ fastener spacing of 30" o.c. <br /> (Factor of Safety=2) 114.3 psf @ fastener spacing of 24" o.c. <br /> Panel Attachment: #9-15 or#10-14 x 1.5" long wood screw with washer <br /> At panel ends @ 5.5"-3.5"-5.5" o.c. across panel width <br /> At interior @ 9" o.c. across panel width <br /> Sidelap Attachment: 1/4"-14 x 7/8" long SDS with washer @ max 30" o.c. <br /> Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard <br /> Requirements for Metal Roofing Systems'. <br /> Code Compliance: The product described herein has demonstrated compliance with FBC <br /> 2017 Section 1507.4. <br /> Product Limitations: Design wind loads shall be determined for each project in accordance <br /> with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress <br /> design. The maximum fastener spacing listed herein shall not be <br /> exceeded. This evaluation report is not applicable in High Velocity <br /> Hurricane Zone. Refer to current NOA for use of this product in High <br /> Velocity Hurricane Zone. Fire classification is not within scope of this <br /> Evaluation Report. Refer to FBC 2017 Section 1505 and current <br /> approved roofing materials directory or ASTM E 108/UL790 report <br /> from an accredited laboratory for fire ratings of this product. <br /> Supporting Documents: TAS 125-03 Test Reports <br /> Hurricane Test Laboratory <br /> -Report No. 0293-0611-05, Reporting Date 8/31/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.