My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1677
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1677
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 12:14:49 PM
Creation date
5/9/2022 12:14:47 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1677
Building Department - Name
WATSON,JOHN & SUE
Address
37946 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- 1 <br /> 83. <br /> PWT: M E <br /> ]/19/15 <br /> a <br /> ROOF PANEL SEE DETAIL 1 9 (NP') PANEL FASTENER PANEL OVERLAP <br /> ,,--.-,-THIS SHEET W NDING LOADETABLE ALLOWABLE <br /> _ o <br /> II II II z <br /> UNDERLAYMENT SHALL BE INSTALLED DECK ATTACHMENT AND 1/4" X 7/8" SDS <br /> AS PER MANUFACTURER'S INSTALLATION SUPPORTS MUST BE SPACING PER ALLOWABLE z <br /> GUIDELINES DESIGNED AND INSTALLED WIND LOAD TABLE <br /> BY OTHERS <br /> RAFTER/JOIST/TRUSS <br /> AT MAX. 24" O.C. <br /> UO <br /> t�M <br /> TYPICAL PANEL INSTALLATION X-SECTION Z <br /> Q SUN <br /> ALLOWABLE UPLIFF PRESSURE c YJ� <br /> U fnE'd O <br /> OVERLAP PANEL PRESSURE tt <br /> z <br /> FASTENERS FASTENERS L <br /> SPACING SPACING (PSF) j o^� <br /> ALONG RIB ALONG RIB <br /> 30" 30" 61.8 <br /> 24" 24" 114.3 ' 2 <br /> J W uS <br /> 1 1/2" c n <br /> 1/4" X 7/8" SDS a. m <br /> ® MAX 30 O.C. #9-15 OR #10-14 X 1.5" LONG m a tom <br /> WOOD SCREW WITH WASHER cr <br /> ® MAX. 30" O.C. Boa <br /> z <br /> MIN 26 GA. PANEL GENERAL NOTES: <br /> 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE �za <br /> FLORIDA BUILDING CODE (FBC). _ � <br /> 2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF <br /> PANEL = 36". 'g <br /> 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS <br /> SPECIFIED ON THIS DRAWING. <br /> 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. <br /> THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN <br /> WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. <br /> 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA <br /> UNDERLAYMENT J BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM <br /> REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. <br /> PLYWOOD 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS <br /> 19/32" THICK (MIN.) REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. <br /> DETAIL 1 <br /> N HV. <br /> C2174-8 <br /> SHEEP NO. <br /> 1 OF 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.