Laserfiche WebLink
D <br /> Q <br /> � w <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall.be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to.comply with R401:3 of the F.B.C.- <br /> 3., Compaction test required if 24"or-more.of fill.dirt is brought in at any one place. <br /> 4: Tie'in survey,required before pouring concrete. <br /> 5: Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered,and marked at time of first inspection. <br /> 8: All A:D.A' requirements shall-be.met: <br /> R. No electric,.plumbing;mechanical,or framing shall be covered without an inspection and . <br /> approval first. . <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances,shall not be installed in a location:where subject to mechanical damage unless <br /> protected by approved barriers. M303;4 of the F.B.0 <br /> 12. Water heaters shall.comply with section P607.3 of the E.B.C. <br /> 13. Foundation supports for AX units shall b:e raised at least 3" above finished grade. M1308:1 .. " <br /> 14:.Returri air in all bedrooms. F.B:C. M1620:4 <br /> 1.5. Smoke detectors.are to be installed in accordance with R3.13:1 of the F.B.C. <br /> 16:All glazing requirements are to be iri accordance with R308.4 of the F.B.0 <br /> 17. All means of egress are to be.in accordance_with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer in showers or tubs.R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AM type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall.be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />