Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016-N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25.-R403.5.3Hot.water pipe insulation <br /> Insulation for hot-water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> followin . . <br /> .9 .. <br /> Piping:-h inch (19.1 mm)and larger in:nominal diameter. <br /> Piping.serving more than one dwelling unit: <br /> Piping located outside'the-conditioned space. <br /> Piping from the water heater to a distribution manifold.. <br /> .Piping,located under a floor slab.- <br /> Buried in piping,. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.- Blower-door test shall be provided.before CO. <br /> 26.A cony of the enerj&cacls-shall be with Oermit at all times <br /> 27 Copy of final'insulation report shall be provided ivith neimit before rinaL <br /> 28.No fence, pool or screen enclosure :is issued with this permi>~ . <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.:-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />