My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-918
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-918
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2022 8:00:09 AM
Creation date
5/25/2022 8:00:07 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-918
Building Department - Name
DR HORTON
Address
8015 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 6, BLOCK 15, ZEPHYR.LAKES SUBDIVISION PHASE 2D <br /> AS RECORDED IN PLAT BOOK 82, PAGE(S) 62-64, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> ON LOT CALCULATIONS <br /> LOT = 5.927 SQ. FT. <br /> LIVING AREA = 1.498 SQ. FT. <br /> GARAGE = 385 SQ. FT. <br /> ENTRY = 17 SQ. FT. <br /> LANAI = 0 SQ. FT. <br /> PATIO = 80 SO. FT. <br /> DRIVEWAY = 409 SQ. FT. <br /> A/C PAD = 12 SO. FT. <br /> WALKWAY = 24 SQ. FT. <br /> IMPERVIOUS = 41% <br /> = 2425 SQ. FT. r'RC 2:p ?o <br /> SOD — 3.502 SQ. FT. y of ip <br /> OFF LOT CALCULATIONS A (q,YF <br /> RIGHT OF WAY = 587 SQ. FT. 4T/9 S <br /> DRIVE APRON = 133 SQ. FT. @p?q U@O/CyT R/In. <br /> PUBLIC S/W — 245 SO. FT. Cpl c 80� yZII 016 k, z <br /> SOD 209 S0. FT. R/cyp Aqq pygY 1" = 30' <br /> TOTALS W4A4- Cf,�� qSF GRAPHIC SCALE <br /> AREA = 6.514 SQ. FT. es\ 0 15 30 <br /> DRIVEWAY = 542 SQ. FT. <br /> SIDEWALK = 269 SQ. FT. \` <br /> SOD = 3,711 SQ. FT. <br /> /47 <br /> 10 <br /> OOr h / ? <br /> r <br /> i O <br /> n� i .hry arVV <br /> boo h e(pk � <br /> \ g(OC\s <br /> Curve Table <br /> •� Curve+ Length Radius Delta Chord Bearing Chord <br /> 2fipQ2"4 A" C` / Ci 49.18 1200.00 220'54' 58550 30'E 49.18 <br /> PREPARED FOR: yyR o 6?R cz 53.90' 1315.00 2z054• se55o30•E. saes' <br /> �I , P 1 `F '49�f <br /> ®'R NUlili)N• T @q 2 Sl/@0 fgFq C3 305.44' 1175.00 1433'38' S89 25'38'E 304.59' <br /> ookg8o@,/4S/o @N¢ 1 ' C4 103.2W 1175.00' 5M2'11• S84'29'52'E 103.25' <br /> pgGF 3j ygSF C5 202-16' 1175.00' 951'27• 1 S7156.41-E 201.91' <br /> BUILDING SETBACKS <br /> FRONT: 20• <br /> GARAGE 25' <br /> REAR: 15' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: <br /> LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE —•—•— BUILDING SETBACK UNE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS Pc POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING dK CENTERLINE RP PT RADIUS POINT TANGENCY <br /> SURVEYING INC. ———— RIGHT OF WAY LINE PRO POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED.ON NAVD 1988 %LO PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> (P) PER PLAT <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES :r:;:: CONCRETE (C) CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING s/W SIDEWALK SO. FT. SQUARE FEET <br /> F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.I.R.M. FLOOD INSURANCE RATE MAP <br /> CONSTRUCTION. NAVD NORTH AMERICAN VERTICAL DATUM. <br /> D&UE DRAINAGE&UTILITY EASEMENT <br /> THIS IS NOT A SURVEY o� DRAINAGE&ACCESS <br /> ENT,(SEMEN DRAINAGE ) <br /> THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC) <br /> LOOD NOTE: SURVEYOR NOTES: <br /> IF HAVE EXAMINED THE F.I.R.M. MAP NO.12101CO293F, DATED 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> 09/28 2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO UE IN <br /> LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> ZONE AE•,DENOTES AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD OF WAY, RESTRICTIONS OF RECORD WHICH <br /> AREAS SUBJECT TO INUNDATION BY THE 1%ANNUAL CHANCE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> EVENT,BASE FLOOD ELEVATIONS DETERMINED TO BE 55.1.THE SURVEYOR <br /> MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE SOUTHEASTERLY LINE AS[" 3. NOT VAUD WITHOUT THE AUTHENTIC <br /> OF LOT,8,BLOCK 15 soNc s2259'03•4,PER PLAT. iELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> A ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> (FIELD DATE A <br /> ) REVISED: MERICAN SURVEYING SURVEYOR AND MAPPER. <br /> SCALE 1• 30 FEET !& MAPPING INC. ♦s;•c;,+•+r e„ Digitallysignedby JamesWBoleman <br /> DN:c=us,sr-Florida,)=Orlando, <br /> -AMERICAN SURVEYING& <br /> APPROVED BY: ' ' MAPPING,+ ' Bolema INC,m=JamesW <br /> 200831 LOT S.BLOCK • . .- gz= email=)boleman@asmcorpomte.com FOR <br /> JOB NO. 15 3191 Maguire Blvd,Suite 200.Orlando,FL 32803 ®mmc�o !: Date:1070.083408]1:56-04'00' THE <br /> FIRM <br /> DRAWN BY: D58 407•a2ii 7s79 JAMES W. BOLEMAN PSM 6485 oAtE <br /> PLOT PLAN OB 20 2020 JG americansurve in andma in ,com # <br />
The URL can be used to link to this page
Your browser does not support the video tag.