Laserfiche WebLink
Sing e Faml - D welling <br /> Plan Review Comments: <br /> 1. F.E. shall be a minimum of 8" above the road elevation and an engmeered'site plan. <br /> 2: Lots shall b.graded to.comply with.R401:3 oft e'-F.B.C.. <br /> 3: Compaction test required if 24'',or more of fill dirt is brought in at any one place. <br /> 4 Tie in survey required before pouring concrete: <br /> 5; 'Driveways require a R.OM.use permit: All 4 sides of driveway thru the sidewalk:shall have <br /> expansion material. <br /> .6. All setbacks shall be met. <br /> 7: All property:markers shall be uncovered.-arid marked attime of first inspection. <br /> 8:: All A:D.A. requirements shall be,met: . <br /> 9. :No electric,plumbing;mechanical, or framing shall be:covered without an inspection and .. <br /> approval first:" <br /> l0: All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not b.e installed in a location where.subject.to:mecl ani6ai.damage unless <br /> protected by:approved barriers. M303:4 of the F:B.0 <br /> 12..Waterheaters.shall comply with section P607.3 of the:F.B:C: <br /> 13:-Foundation.suliports for A/C.-units-,shall be'Mised at least 3" above finished grade. M1308:1; <br /> 14.Return air in all bedrooms. F.B.C. 'M1620:4 <br /> 15. Smoke detectors are to be installed'in accordance with R313:T of the F.B.C. <br /> . 16:All glazing-requirements are to bean accordance:with R308A of the F.B:C: <br /> 17. All means of egress are to be:in accordance:with RM 1 of the F.B.C: . <br /> 18. "Green gypsum:board" shall not be used as"a backer in showers or tubs. R702.:4.2 F.B.C. , <br /> 19: Combination-type AFCI.breakers are required at all locations requiring:an'AFCI type breaker.: <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached-garage. They shall be installed in accordance with the F.B.G: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground:plumbing and electric.- <br /> 22: All 201:6 N.E.C. Codes will be enforced: <br />