My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1058
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1058
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2022 2:56:59 PM
Creation date
5/26/2022 2:56:58 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1058
Building Department - Name
DR HORTON
Address
7863 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 � D <br /> RIR <br /> a <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F:B.C: <br /> 3. Compaction test required if 24"or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require-a R.O..W. use permit. A114 sides of drivewaythru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time:of first inspection_ . <br /> 8: All A.D.A. requirements shall.be met: <br /> 9: No electric,,plumbing;mechanical, or franiing shall be covered without an inspection and - <br /> approval first: <br /> 10. All Garages,shall comply with section R302:6 of the F.B:C. (Fire Separation): <br /> 1-1. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303;4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for-AX-units shall be raised at least 3" above finished grade. M1308.:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620:4 <br /> 15. Smoke detectors.are to be installed in accordance with R3111 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4.of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C: . <br /> 18. `-`Green gypsum board" shall riot be used as a backer'in showers or tubs. R702:4.2 F.B.C. . <br /> 10. Combination-type AM.breakers are required at all locations requiring an AFCI type breaker. . <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and.electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.