f <br /> 23. Tamper-Resistant Receptacles in accordance with 406.l l ofthe 2016 N.E.0 <br /> 24. M accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation <br /> Insulation for'hot water pipe with'a minimum thermal resistance (R-__value) of R-3 shall be applied to the <br /> following: <br /> Piping 3!,inch (19.1 mm) and larger-in nominal diameter., <br /> Piping;serving more than.one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping Irom the Water heater to:a distribution manifold:. <br /> Piping,located under.a floor slab. <br /> Buried in piping. <br /> Supply and return piping in,recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O. <br /> 26.A cony of-the energu cacls shall be with perry:it at all times <br /> 27. Cony of final insulation report shaft be provided with permit before final <br /> 28:No fence,-Pool or'screen enclosure Is.issued.with:this permit. <br /> F.F.E.-Finished Floor Elevation <br /> RB.Cm Florida Building Code 6ffi Edition <br /> R.D.W.-Right of Way <br /> A.D.A.-Americans with Disabilities-Act N.E.C.-National Electric Code(2016) <br />