Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method.Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Permit#- <br /> :Job Information <br /> Builder: DR Horton Community: Lot: 22/10 <br /> Address: <br /> City: Zephyrhills State: FL Zip: <br /> Air Leakage TeSt ReSUItS Passing resu/ts must:nJeet:either the Perforrnance;-Prescriptive, or ERI Method <br /> 0 PRESCRIPTIVE METHOD-The building or dwelling unit shall be.tested and verified As having an air leakage rate of not exceeding 7 air <br /> changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones T and 2. <br /> Q' PERFORMANCE or ERI'METHOD-Theā€¢building:or dwelling_unit,'shall:be testedand Verified as having an air leakage tate.of riot.exceeding- <br /> the selected ACH(5O)walue,as§hown on'Forrn R405;20;1T(Performance)or R406-201:7(ERI),section labeled as infilttation;sub-section ACH50. <br /> ACH(50)specified on Form R405=2017-Energy Calc(Performance)or''R406 2017(ERl); 7.000 <br /> x 60 = -2.091128E35 = Method for calculating building volume: <br /> CFM(50) Building Volume ACH(50) O Retrieved from architectural plans <br /> PASS 0 Code software calculated <br /> When ACH(50)is less than 3,Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During-testing: <br /> I.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> Testing Company <br /> Company Name: Phone: <br /> I hereby verify that the above Air Leakage results_are in accordance with the 2017 6th Edition Florida Building Code <br /> .Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 8/10/2020 121:21 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Pagel of 1 <br />