My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1064
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1064
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2022 3:00:58 PM
Creation date
5/26/2022 3:00:56 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1064
Building Department - Name
DR HORTON
Address
6610 COBBLE BLISS ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- wrightsofto <br /> Manual S Compliance Report oa <br /> Entire-House By: <br /> Progressive Air Systems, Inc Plan: 2795Camden <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 22 Blk 10 Silverado, Zephyrhills, FL <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 32883 Btuh Entering coil DB: 77.3°F <br /> Outdoor design WB: 77.1 OF Latent gain: 5478 Btuh Entering coil WB: 63.7°F <br /> 'Indoor design DB: 75.0°F Total gain: 38361 Btuh <br /> Indoor RH: 50% Estimated airflow: 1383 cfm <br /> Manufacturer's Performance Data at-Actual Design Conditions <br /> Equipment type: Split ASHP - <br /> Manufacturer: Bryant Model: 215BNA042****A+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Sensible capacity: 33898 Btuh 103%of load <br /> Latent capacity: 5894 Btuh 108%of load <br /> Total capacity: 39792 Btuh 1040/o of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 32298 Btuh . Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data.at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Bryant Model: 215BNA042****A+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Output capacity: 37812 Btuh 117%of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1383 cfm <br /> Output capacity: 9.6 kW 102%of load Temp. rise: 22 OF <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsoft' 2020-Aug-1013:31:39 <br /> Q. Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...esktop\Jill\Wrightsoft Files\DR Horton\2795.rup Calc=MJ8 House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.