Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida:Department of Business and Professional Regulation - Residential Performance Method <br /> Proj' t.N C mdren 279 Elev D 1 Builder Name: DR Horton <br /> Street: (0(010 CO b[� 1�7sS 5- � Permit Office: <br /> City,State,Zip: Zephyrhills,FL,335� Z Permit Number `fir <br /> Owner: Jurisdiction: . <br /> 40 �� <br /> Design Location: FL;Tampa County: Pasco( offaClimate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2338.8 sqft.) Insulation Area <br /> 2.'Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1945.20 ft2. <br /> b.Frame-Wood,Adjacent R=13.0 393.56 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A <br /> R= 2 ft <br /> 4. Number of Bedrooms 4 d.N/A R= ft2. <br /> 5. Is this a worst case? No 10.Ceiling Types (3041.0 sgft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2836.00 ft2 .. <br /> 6. Conditioned floor area above grade(ft2) 2836 b.Knee Wall(Vented) R=19.0 205.00 ft2 <br /> Conditioned floor area below grade'(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(330.0 sgft.) - Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 529 <br /> a. U-Factor: Dbl,U=0.34 258.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 72.00 ft2 12.Cooling.systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 41.5 SEER:15.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.214 ft. <br /> Area Weighted Average SHGC: 6.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (2836.0 sgft.) Insulation Area EF:0.950 <br /> a..Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.116 Total Proposed Modified Loads: 86.45 PASS <br /> Total Baseline Loads: 87.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and. 09"iHE$?,gp� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: LMb- A&;&, Before construction is completed s� <br /> DATE: this building will be inspected for y <br /> compliance with Section 553.908 <br /> I herebycertify that this building,as designed,is in compliance Florida Statutes. <br /> y 9, 9 p <br /> with the Florida Energy Coodde�f,�� OD WrET� <br /> OWNER/AGENT: / BUILDING OFFICIAL: <br /> DATE: M 7 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier.and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no.greater than 7.00 ACH50(R402.4.1.2). <br /> 8/10/2020 1:30 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />