Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: C mden 2795 Elev D Builder Name: DR Horton <br /> Street: lob10 (C) 31- 9. v Permit Office: <br /> City,State,Zip: Zephyrhills,FL,3 3S� 2 Permit Number: <br /> Owner: Z I Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2338.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1945.20 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 393.56 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A 2 <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (3041.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2836.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2836 b.Knee Wall(Vented) R=19.0 205.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(330.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 529 <br /> a. U-Factor: Dbl,U=0.34 258.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 72.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 41.5 SEER:15.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.214 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (2836.0 sgft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2836.00 ft2 EF:0.950 <br /> 9 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.116 f1�7J <br /> Total Proposed Modified Loads: 86.45 PASS <br /> SS <br /> Total Baseline Loads: 87.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans andTx E sx, �. <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> sri�rr , <br /> with the Florida Energy Code. <br /> PREPARED BY: L a Before construction is completed w <br /> :r-0 <br /> DATE: 2-10-20 this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. . <br /> with the Florida Energy Code O.:y � <br /> OWNER/AGENT: / BUILDING OFFICIAL: <br /> DATE: �1 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 8/10/2020 1:30 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />