My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1119
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1119
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2022 8:02:13 AM
Creation date
5/27/2022 8:02:11 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-1119
Building Department - Name
ROSSELLO ANGELO & RUTH E LIVING TRUST
Address
5424 10TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: Rossello-542410thSt <br /> F_-Calc5 Date: Feb 03,2021 <br /> Plus,Inc. Entire House By: E-Calcs Plus,Inc. <br /> E-Calcs Plus, Inc. <br /> 9250 Corkscrew Rd,Suite 8,Estero,FL 33928 Phone:239.810.6106 Email:eric@ecalcsplus.com Web:www.ecaicsplus.com License:HERS Rater ID 0757810 <br /> Project Information <br /> For: Rossello-5424 10th St <br /> 5424 10th St,Zephyrhills, FL 33542 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 19775 Btuh Entering coil DB: 76.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 4358 Btuh Entering coil WB: 63.5'F <br /> Indoor design DB: 75.0°F Total gain: 24134 Btuh <br /> Indoor RH: 50% Estimated airflow: 953 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030POOGAO+FB4CNF030L++TXV <br /> Actual airflow: 953 cfm <br /> Sensible capacity: 22057 Btuh 112%of load <br /> Latent capacity: 5012 Btuh 115%of load <br /> Total capacity: 27069 Btuh 1121/6 of load SHR: 81% <br /> Heating 'Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.5°F Heat loss: 17359 Btuh Entering coil DB: 69.1°F <br /> Indoor design DB: 70.07 <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030POOGAO+FB4CNF030L++TXV <br /> Actual airflow: 953 cfm <br /> Output capacity: 26492 Btuh 153%of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -44 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Carrier Model: AFUE 100 <br /> Actual airflow: 953 cfm <br /> Output capacity: 5.0 kW 98%of load Temp.rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> A -* wrightsoft- 2021-Feb-0510:53:28 <br /> ,d�. „. .....,._ Right-Suite@ Universal 2021 21.0.03 RSU28254 Page 1 <br /> 24 10th StlRossello-5424 10t... h St 2.5.2021.rup Calc=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.