Laserfiche WebLink
Project Summary Job: Rossello-542410thSt <br /> E-CaICS ry Date. Feb 03,2021 <br /> Plus,Inc. Entire House By: E-Calcs Plus,Inc. <br /> E-Calcs Plus, Inc. <br /> 9250 Corkscrew Rd,Suite 8,Estero,FL 33928 Phone:239.810.6106 Email:eric@ecalcsplus.com Web:www.ecalcsplus.com License:HERS Rater ID 0757810 <br /> • Information <br /> For: Rossello-5424 10th St <br /> 5424 10th St,Zephyrhills, FL 33542 <br /> Notes: <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 28 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 12521 Btuh Structure 14417 Btuh <br /> Ducts 4838 Btuh Ducts 5358 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 17359 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19775 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2570 Btuh <br /> Ducts 1788 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1440 1440 Equipment latent load 4358 Btuh <br /> Volume(ft3) 13824 13824 <br /> Air changes/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 24134 Btuh <br /> Equiv.AVF(cfm) 104 53 Req.total Capacity at 0.70 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB030POOGAO Cond CH14NB030POOGAO <br /> AHRI ref 204861632 Coil FB4CNF030L++TXV <br /> AHRI ref 204861632 <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating Input Sensible cooling 20020 Btuh <br /> Heating output 28600 Btu h @ 47°F Latent cooling 8580 Btuh <br /> Temperature rise 27 OF Total cooling 28600 Btuh <br /> Actual air flow 953 cfm Actual air flow 953 cfm <br /> Air flow factor 0.055 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.50 in H2O Static pressure 0.50 in H2O <br /> Space thermostat Load sensible heat ratio 0.82 <br /> Capacitybalance point=31 OF <br /> Backup: CarrierAFUE 100 <br /> Input=5 kW, Output= 17061 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -� wrightsoft^ 2021-Feb-0510:53:28 <br /> '� +-»• M Right-Suite®Universal 2021 21.0.03 RSU28254 Pagel <br /> ...24 10th StlRossello-5424 10th St 2.5.2021.rup Calc=MJ8 Front Door faces: W <br />