Laserfiche WebLink
o _ <br /> 4 <br /> Single Family Dwelling <br /> Plan Review Comments . <br /> 1. F:F.E:.shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: .Lots shall be graded to.comply with R401:3.of the F.-B.C. <br /> I, Compaction test required if 24 or more,of fill dirt is brought in 'at any one.place. <br /> 4: Tie in survey required before pouri ng concrete. . <br /> 5: Driveways require.a W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6' .All setbacks shall be met. <br /> 7, All property markers shall be uncovered-and marked at time of first inspection. <br /> 8:: All A.D.A. requirements shall be met: <br /> 9; .'No electric,-plumbing,mechanical, or,framing shall,be covered without an inspection and . <br /> -approval first:. <br /> 10: All Garages shall-comply with section R302,6 of the RJIC. (Fire Separation): - <br /> 11. Appliances shall not-be installed in a location where subject to mechanical,damage unless <br /> protected by approved barriers. M303:4 of the RB:C <br /> 12-Water heaters shall comply with section P607.3.of the E.B.C. <br /> 11 Foundation supports for A/.0 units,shall be raised at least 3" above finished grade. M1308:1. . <br /> 14.Return air in all bedrooms: F.B:C.. Ml620.4 <br /> 1.5. Smoke detectors are to be' installed in accordance with.R313:1 of the,F.B.C. <br /> 16: All msretoteinaccordance' ith R308A of the FB:C:w <br /> 17. All means.of egress are.to be in accordance with R311 of the F.B.C. <br /> 18."Green gypsum.�board"shall not be used as a backer in showers or tubs: R702:4.2 F.B.C. <br /> . 19:,Combination-type AM breakers are required at all locations requiring an AM type breaker-. <br /> 20. Carbon monoxide alarms will be required in new,constrdction that'uses fossil-burning heating <br /> or appliances or an attached-garage. They shall be'installed in accordance with-the F.B.C. <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22: All 2016 N.E.C. Codes will be enforced: <br />