My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1191
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1191
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 2:40:52 PM
Creation date
6/1/2022 8:58:30 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1191
Building Department - Name
DR HORTON
Address
7053 STEER BLADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-��- Manual S Compliance Report <br /> wrightsoft® Date: <br /> Entire House By: <br /> Plan: Plan 2795 Camden <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> lop <br /> • • • <br /> For: DR Horton <br /> Lot 4 Blk 14 Silverado, Zephyrhills, FL <br /> • • • • o <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 34477 Btuh Entering coil DB: 77.1'F <br /> Outdoor design WB: 77.1 of Latent gain: 5203 Btuh Entering coil WB: 63.6°F <br /> Indoor design DB: 75.0°F Total gain: 39680 Btuh <br /> Indoor RH: 50% Estimated airflow: 1383 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Sensible capacity: 33904 Btuh 98%of load <br /> Latent capacity: 5871 Btuh 113%of load <br /> Total capacity: 39775 Btuh 100%of load SHR: 85% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 32296 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Bryant Model: 215BNA042+FX4DN(B,F)043 <br /> Actual airflow: 1383 cfm <br /> Output capacity: 37812 Btuh 117%of load Capacity balance: 33 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 of <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1383 cfm <br /> Output capacity: 9.6 kW 102%of load Temp. rise: ' 22 of <br /> Meets are all requirements of ACCA Manual S. <br /> .► wri htsoft® 2020-Nov-20 14:age I <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page <br /> 'C'� ...tsoft Files\SF Tampa\2795 w Multi gen suite.rup Calc=MJ8 House Front faces:SE <br />
The URL can be used to link to this page
Your browser does not support the video tag.