My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1201
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1201
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2022 3:27:12 PM
Creation date
6/1/2022 9:05:09 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
20-1201
Building Department - Name
DR HORTON
Address
7870 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q <br /> d �I <br /> L <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E...shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> .21 Lots shall be graded to.comply with R401.3 of the F.B.C.. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in.survey required before pouring concrete. <br /> 5: Driveways require a R.O.W. use permit. All 4 sides-of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> -7. All property markers shall be uncovered and-maiked at time.of first-inspection. <br /> 8: All A.D.A. requirerrients shall be met: . <br /> 9. No electric,.plumbing;mechanical,or framing shall be:covered without an inspection and <br /> approval first: <br /> 10.. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location.where subject to mechanical damage unless <br /> protected,by approved barriers. M303.4 of the F.B.0 <br /> 12.Water heaters shall:comply with section P607.3 of the F:B.C. <br /> 13. Foundation supports for A/C units shall be raisedat least 3" above finished grade. M1308:1 -. <br /> 14. Return air in-all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke.detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage.' They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underp— ndpluinbing and electric. <br /> 21 All 2016 N E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.