T <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the„2016 N.E:C <br /> 24. In accordance with the Land Development Code, lots.shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25:-R403.5.3Hot water-pipe insulation <br /> Insulation for hot.water pipe with a minimum thermal resistance (R.-value) of R-3 shall be applied to the <br /> followin <br /> Piping.31; inch (1.9.1 mm) and larger,in nominal diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the Water heater to a distribution manifold. <br /> Piping.located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the enerjy cacis shall be with permit at all times <br /> 27. Copy of final.insulation report shall be provided with permit before rInal . <br /> 28 No fence,pool onscreen enclosure .is issued with this.permit' <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-..Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric_Code(2016) <br />