Laserfiche WebLink
D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one.place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway_ thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks-shall be in et. <br /> 7: All.property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirernents shall be met:_ <br /> 9: No electric,.plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10.All Garages shall comply with section�R302.6 of the F.B:C. (Fire Separation): <br /> 1.1. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved:barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B:C.- <br /> 13. Foundation suliports for A/C units-shall.be raised at least 3" above finished grade. M1308.1 . <br /> 14. Return air in all bedrooms: F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance-with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall he separate from unit to unit: This includes all <br /> underground.plumbing and.electric. <br /> 22: All 2016 N.E.C. Codes will be enforced: <br />