DN-6720:E <br /> FMM-1 (A)5 FMM-101 (A), N OTI F I E N® <br /> FZM-1 (A) & FDM-1 (A) a <br /> Monitor Modules with FlashScan@ by Honeywell <br /> Intel ligent/Addressable Devices <br /> General <br /> Four different monitor modules are available for Notifier's F7,_�s__ <br /> intelligent control panels for a variety of applications. Monitor <br /> modules supervise a circuit of dry-contact input devices, <br /> such as conventional heat detectors and pull stations, or •:'� - ,�. �: <br /> monitor and power a circuit of two-wire smoke detectors .r °` •- .� '"' ' <br /> (FZM-1(A)). e. -.�.LL°• <br /> FMM-1(A) is a standard-sized module (typically mounts to a °"'-"' <br /> 4" [10.16 cm] square box) that supervises either a Style D <br /> (Class A) or Style B (Class B) circuit of dry-contact input D� .. <br /> M1•uDRI.1 D LDruI9[I DDMIn tD <br /> devices. •L�.v,, ..D.LL.L.. D <br /> Net°D L — v <br /> FMM-101(A) is a miniature monitor module a mere 1.3" <br /> 3.302 cm H x 2.75" 6.985 cm W x 0.65" 1.651 cm D that <br /> supervises a Style B (Class B) circuit of dry-contact input <br /> devices. Its compact design allows the FMM-101(A) to be a A emir <br /> mounted in a single-gang box behind the device it monitors. 01 <br /> FZM-1(A) is a standard-sized module that monitors and <br /> supervises compatible two-wire, 24 volt, smoke detectors on <br /> a Style D(Class A)or Style B (Class B)circuit. FMM-1(A)(Type H) <br /> FDM-1(A)is a standard-sized dual monitor module that mon- <br /> itors and supervises two independent two-wire Style B(Class open dry-contact alarm activation devices. May also be used <br /> B)dry-contact initiating device circuits(IDCs)at two separate, to monitor normally-open supervisory devices with special <br /> consecutive addresses in intelligent,two-wire systems. supervisory indication at the control panel. Monitored circuit <br /> FlashScanO (U.S. Patent 5,539,389) is a communication may be wired as an NFPA Style B(Class B)or Style D(Class <br /> protocol developed by NOTIFIER that greatly increases the A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor <br /> speed of communication between analog intelligent devices. (provided) terminates the Style B circuit. No resistor is <br /> Intelligent devices communicate in a grouped fashion. If one required for supervision of the Style D circuit. <br /> of the devices within the group has new information, the FMM-1(A) OPERATION <br /> panel CPU stops the group poll and concentrates on single <br /> points. The net effect is response speed greater than five Each FMM-1(A)uses one of the available module addresses <br /> times that of other communication protocols. on an SLC loop. It responds to regular polls from the control <br /> panel and reports its type and the status(open/normal/short) <br /> FMM-1(A) Monitor Module of its Initiating Device Circuit(IDC). A flashing LED indicates <br /> that the module is in communication with the control panel. <br /> • Built-in type identification automatically identifies this The LED latches steady on alarm (subject to current limita- <br /> device as a monitor module to the control panel. tions on the loop). <br /> • Powered directly by two-wire SLC loop. No additional FMM-1(A)SPECIFICATIONS <br /> power required. <br /> • High noise(EMF/RFI) immunity. Nominal operating voltage: 15 to 32 VDC. <br /> • SEMS screws with clamping plates for ease of wiring. Maximum current draw: 5.0 mA(LED on). <br /> • Direct-dial entry of address:01 —159 on FlashScan loops; Average operating current: 375 pA(LED flashing), 1 com- <br /> 01 —99 on CLIP loops. munication every 5 seconds,47k EOL. <br /> • LED flashes green during normal operation (programma- Maximum IDC wiring resistance: 1500 Ohms. <br /> ble option)and latches on steady red to indicate alarm. Maximum IDC Voltage: 11 Volts. <br /> The FMM-1(A) Monitor Module is intended for use in intelli- <br /> gent,two-wire systems,where the individual address of each EOL resistance:47K Ohms. <br /> module is selected using the built-in rotary switches. It pro- Temperature range:32°F to 120°F(0°C to 49°C). <br /> vides either a two-wire or four-wire fault-tolerant Initiating <br /> Device Circuit(IDC)for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. <br /> supervisory devices.The module has a panel-controlled LED Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> indicator. The FMM-1(A) can be used to replace MMX-1(A) 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> modules in existing systems. 2.125"(5.398 cm)deep box. <br /> FMM-1(A)APPucAnoNs <br /> Use to monitor a zone of four-wire smoke detectors, manual <br /> fire alarm pull stations, waterflow devices, or other normally- <br /> DN-6720:E•07/30/2015—Page 1 of 4 <br />