My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1261
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1261
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2022 8:17:27 AM
Creation date
6/1/2022 9:44:17 AM
Metadata
Fields
Template:
Building Department
Company Name
COPELAND FAITH PARTNERS LLC
Building Department - Doc Type
Permit
Permit #
20-1261
Building Department - Name
COPELAND FAITH PARTNERS LLC
Address
3752 COOPELAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FMM-101(A) Mini Monitor Module Temperature range: 327 to 120°F(0°C to 49°C). <br /> • Built-in type identification automatically identifies this Humidity range: 10%to 93%noncondensing. <br /> device as a monitor module to the panel. Dimensions: 1.3"(3.302 cm) high x 2.75"(6.985 cm)wide x <br /> • Powered directly by two-wire SLC loop. No additional 0.65"(1.651 cm)deep. <br /> power required. Wire length: 6"(15.24 cm) minimum. <br /> • High noise(EMF/RFI) immunity. <br /> • Tinned,stripped leads for ease of wiring. FZM-1(A) Interface Module <br /> • Direct-dial entry of address:01 —159 on FlashScan loops; . Supports compatible two-wire smoke detectors. <br /> 01 —99 on CLIP loops. <br /> • Supervises IDC wiring and connection of external power <br /> source. <br /> 3 1415 0 1 ADDRESS 0 High noise(EMF/RFI)immunity. <br /> 3 126� . <br /> 3 3 SEMS screws with clamping plates for ease of wiring. <br /> 114 LOOP0� . <br /> 4 Direct-dial entry entry of address: 01 —159 on FlashScan <br /> 15 5 loops, 01—99 on CLIP loops. <br /> 87 87 LED flashes during normal operation; this is a program- <br /> TENS ONES mable option. <br /> • LED latches steady to indicate alarm on command from <br /> control panel. <br /> Y The FZM-1(A) Interface Module is intended for use in intelli- <br /> O O U gent, addressable systems, where the individual address of <br /> O each module is selected using built-in rotary switches. This <br /> °Q module allows intelligent panels to interface and monitor two- <br /> wire conventional smoke detectors. It transmits the status <br /> (normal, open, or alarm) of one full zone of conventional <br /> detectors back to the control panel. All two-wire detectors <br /> being monitored must be UL compatible with the module. <br /> The FMM-101(A) Mini Monitor Module can be installed in a The FZM-1(A) can be used to replace MMX-2(A) modules in <br /> single-gang junction directly behind the monitored unit. Its existing systems. <br /> small size and light weight allow it to be installed without rigid FZM-1(A) APPLICATIONS <br /> mounting. The FMM-101(A) is intended for use in intelligent, <br /> two-wire systems where the individual address of each mod- Use the FZM-1(A) to monitor a zone of two-wire smoke <br /> ule is selected using rotary switches. It provides a two-wire detectors. The monitored circuit may be wired as an NFPA <br /> initiating device circuit for normally-open-contact fire alarm Style B (Class B) or Style D (Class A) Initiating Device Cir- <br /> and security devices. The FMM-101(A) can be used to cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates <br /> replace MMX-101(A)modules in existing systems. the end of the Style B or D (class B or A) circuit (maximum <br /> IDC loop resistance is 25 Ohms). Install ELR across termi- <br /> FMM-101(A)APPLIcAnoNs nals 8 and 9 for Style D application. <br /> Use to monitor a single device or a zone of four-wire smoke FZM-1(A) OPERATION <br /> detectors, manual fire alarm pull stations, waterflow devices, <br /> or other normally-open dry-contact devices. May also be Each FZM-1(A) uses one of the available module addresses <br /> used to monitor normally-open supervisory devices with spe- on an SLC loop. It responds to regular polls from the control <br /> cial supervisory indication at the control panel. Monitored cir- panel and reports its type and the status (open/normal/short) <br /> cuit/device is wired as an NFPA Style B (Class B) Initiating of its Initiating Device Circuit(IDC). A flashing LED indicates <br /> Device Circuit. A 47K Ohm End-of-Line Resistor (provided) that the module is in communication with the control panel. <br /> terminates the circuit. The LED latches steady on alarm (subject to current limita- <br /> tions on the loop). <br /> FMM-101(A)OPERATION <br /> Each FMM-101(A) uses one of the available module FZM-1(A)SPECIFICATIONS <br /> addresses on an SLC loop. It responds to regular polls from Nominal operating voltage: 15 to 32 VDC. <br /> the control panel and reports its type and the status (open/ Maximum current draw:5.1 mA(LED on). <br /> normal/short)of its Initiating Device Circuit(IDC). <br /> Maximum IDC wiring resistance:25 Ohms. <br /> FMM-101(A)SPECIFICATIONS <br /> Average operating current: 270 NA, 1 communication and <br /> Nominal operating voltage: 15 to 32 VDC. 1 LED flash every 5 seconds,3.9k eol. <br /> Average operating current: 350 NA, 1 communication EOL resistance:3.9K Ohms. <br /> every 5 seconds, 47k EOL; 600 pA Max. (Communicating, <br /> IDC Shorted). External supply voltage (between Terminals T10 and <br /> Maximum IDC wiring resistance: 1500 Ohms. T11): <br /> Maximum IDC Voltage: 11 Volts. DC voltage:24 volts power limited. <br /> • Ripple voltage:0.1 Vrms maximum. <br /> Maximum IDC Current:450 NA. Current:90 mA per module maximum. <br /> EOL resistance:47K Ohms. Temperature range: 32°F to 120°F(0°C to 49°C). <br /> Page 2 of 4—DN-6720:E•07/30/2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.