Humidity range: 10%to 93% noncondensing. Agency Listings and Approvals <br /> Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain <br /> 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- <br /> 2.125'(5.398 cm)deep box. tory for latest listing status. <br /> FDM-1(A) Dual Monitor Module . UL: S635. <br /> • ULC: S635. <br /> The FDM-1(A)Dual Monitor Module is intended for use in intelli- <br /> gent, two-wire systems. It provides two independent two-wire - <br /> initiating device circuits (IDCs) at two separate, consecutive • CSFM:7300-0028:0219, 7165-0028:0224, <br /> addresses. It is capable of monitoring normally open contact fire 7165-0028:0243. <br /> alarm and supervisory devices; or either normally open or nor- . MEA:457-99-E. <br /> mally closed security devices. The module has a single panel- <br /> controlled LED. • U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, <br /> NOTE:The FDM-1(A)provides two Style B(Class B) IDC circuits NFS2-3030). <br /> ONLY. Style D (Class A) IDC circuits are NOT supported in any • Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, <br /> application. NFS2-3030). <br /> FDM-1(A)SPEcIFicATioNS • Fire Dept. of New York: COA #6121 (NFS2-640, NFS- <br /> Normal operating voltage range: 15 to 32 VDC. <br /> 320), COA#6114(NFS2-3030). <br /> Maximum current draw:6.4 mA(LED on). Product Line Information <br /> Average operating current:750 pA(LED flashing). NOTE:A"suffix indicates ULC-listed model. <br /> Maximum IDC wiring resistance: 1,500 Ohms. FMM-1(A): Monitor module. <br /> Maximum IDC Voltage: 11 Volts. FMM-101(A): Monitor module, miniature. <br /> Maximum IDC Current:240 pA FZM-1(A): Monitor module,two-wire detectors. <br /> EOL resistance:47K Ohms. FDM-1(A): Monitor module, dual, two independent Class B <br /> Temperature range:32°to 120°F(0°to 49°C). <br /> circuits. <br /> Optional surface-mount backbox. <br /> Humidity range: 10%to 93% (non-condensing). SMB500: O p <br /> NOTE. See installation instructions and refer to the SLC Wiring <br /> Dimensions: 4.5 (11.43 cm) high x 4' (10.16 cm) wide x Manual,PN 51253. <br /> 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> 2.125"(5.398 cm)deep box. <br /> FDM-1(A)AUTOMATIC ADDRESSING <br /> The FDM-1(A) automatically assigns itself to two address- <br /> able points, starting with the original address. For example, if <br /> the FDM-1(A) is set to address"26",then it will automatically <br /> assign itself to addresses"26"and"27° <br /> NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. <br /> Terminals 6 and 7 use the first address,and terminals 8 and 9 use <br /> the second address. <br /> QCAUTION: <br /> Avoid duplicating addresses on the system. <br /> Installation <br /> FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly <br /> to a standard 4"(10.16 cm)square, 2.125"(5.398 cm)deep, <br /> electrical box. They may also be mounted to the SMB500 <br /> surface-mount box. Mounting hardware and installation <br /> instructions are provided with each module. All wiring must <br /> conform to applicable local codes, ordinances, and regula- <br /> tions. These modules are intended for power-limited wiring <br /> only. <br /> The FMM-101(A) module is intended to be wired and <br /> mounted without rigid connections inside a standard electri- <br /> cal box. All wiring must conform to applicable local codes, <br /> ordinances,and regulations. <br /> DN-6720:E•07/30/2015—Page 3 of 4 <br />