My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36427 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36427 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 1:41:19 PM
Creation date
1/21/2025 3:30:38 PM
Metadata
Fields
Template:
Building Plans
Street #
36427
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
4751
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q� r <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_ t <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G ' J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />JIL <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />LAV `1'--�, <br />.I I <br />1l TUB/ <br />W/C SHOWER <br />LAV <br />3" VTR <br />JIL <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I �J <br />I I <br />LI u WIC <br />SHOWER <br />STUDOR F� <br />VENTQ I I DBL SINK <br />L T1 W! DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT-C 1624 (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA 1 <br />200 AMP <br />I CTCI-f 11 A.A AI <br />1 �0-200 AMP I IT /—Serial Cable <br />3R <br />Power Co. Feed —\ I.I I_ , #4 Solid COPPER Ground <br />C.O. <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <`> <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT i `� �' GF <br />DINING <br />KITCHEN 1 <br />FI<Xj GFI <br />0<1 <br />0<3 <br />a <br />OCI SWITCH FOR <br />0<3 <br />0(1 DISPOSAL IN CAB <br />0(1 <br />UNDER SINK <br />IN <br />GREAT ROOM <br />/^ >ROUGH -IN\ <br />FOR OPT. <br /><FAN/LIGHT' <br />I <br />I <br />1 <br />UTRY 'v�\ <br />GHT AS <br />=R SPECS <br />I <br />�Oyj <br />ry <br />°,m <br />0 <br />I <br />I <br />I <br />I <br />I <br />I <br />rGF.L—i <br />C.M <br />t <br />1 UPSTAIRS F <br />GFI <br />A.F <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL — UNIT—C 1624 <br />SCALE: Y"=T-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F_ <br />2ND ELECTRICAL — UNIT—C 1624 <br />SCALE: Y"=V-0" <br />� O <br />> O <br />o (D_ M <br />� � r <br />v <br />A� <br />L <br />C) <br />0 <br />L) <br />N <br />N <br />0 <br />a) <br />LID <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal Is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />V) <br />W E <br />0 <br />4 8 <br />0 <br />V m <br />N <br />o ,_Lo M <br />In <br />� U) <br />Mo_a <br />Q J U_ W <br />co LL W a <br />a <br />Z @ 8,0 <br />=o <br />117E 7 Co N <br />U pjO' w <br />m <br />J <br />Ti M Z Q <br />ILW <br />In N J <br />Z O V U O <br />W 1771 [__1 <br />QD <br />Z N M <br />o S <br />z <br />z o <br />n- N <br />N <br />U J <br />- <br />th <br />a <br />VGA <br />U <br />0 LL, o <br />v) c <br />usd <br />U � <br />`9 <br />w <br />L- J E <br />s <br />L <br />U 8 <br />Q N 0 <br />co <br />Q <br />�W <br />Z <br />CM <br />M <br />h <br />a <br />Z <br />4 <br />E <br />w� <br />W o <br />zo <br />Z <br />Qn, <br />E� <br />wo <br />F- fd <br />_, <br />X U <br />U <br />Z <br />o <br />N <br />a�°¢ <br />a <br />.0 <br />0 <br />a��o <br />z <br />�w <br />� <br />�_ <br />�Yo� <br />"m <br />Z <br />N <br />J <br />¢w <br />�m <br />0 <br />z <br />a <br />�W <br />W <br />3 <br /><� <br />xk <br />oLL <br />Jz <br />w <br />,r <br />o <br />CD <br />a <br />�O <br />0 <br />m <br />E <br />N <br />O <br />� <br />� <br />O <br />MCN <br />III <br />M <br />N <br />N <br />r <br />C.0 <br />00 <br />U) m <br />O <br />CNJ <br />ILi7 <br />N <br />(D <br />O <br />O <br />r <br />O <br />r <br />Em <br />T I T <br />� � <br />O <br />z <br />z <br />E O <br />ra <br />U _j Q p <br />J <br />JOB NO: 22-05610-05605 <br />SCALE : AS NOTED <br />SHEET NO. <br />11.2 <br />