Laserfiche WebLink
I <br />I <br />vi <br />TYPICAL 213R MEMORY UNIT PLAN <br />SCALE: 1 /4" = 1'-0" <br />TYPICAL 1BR UNIT <br />SCALE: 1 /4" = 1'-0" <br />STUDIO UNIT PLAN <br />TYPICAL MEMORY UNIT PLAN <br />SCALE: 1 /4" = 1'-0" <br />MECHANICAL GENERAL NOTES <br />1. ITEMS INDICATED WITH "(E)" ARE EXISTING TO REMAIN. <br />2. ITEMS INDICATED WITH "(R)" ARE EXISTING ITEMS WHICH SHALL BE RELOCATED TO THE <br />LOCATION SHOWN ON THIS DRAWING. <br />3. RELOCATE THE INDICATED EXISTING EXHAUST FANS TO THE LOCATIONS SHOWN ON THIS <br />DRAWING, AND CONNECT TO THE EXISTING 6"0 EXHAUST DUCTS. <br />4. PROVIDE A CONDENSATE PUMP FOR EACH NEW AHU; COORDINATE WORK WITH THE <br />ELECTRICAL DRAWINGS. ROUTE THE CONDENSATE DISCHARGE TUBING TO THE SAME <br />LOCATIONS AS THE EXISTING UNITS. <br />5. MAINTAIN REQUIRED CLEARANCES AROUND ALL EQUIPMENT TO ALLOW FOR PROPER <br />MAINTENANCE AND OPERATION. <br />6. CEILING FURR-DOWNS & BULKHEADS, APPROXIMATELY ONE FOOT DEEP (BELOW THE <br />RATED CEILING ASSEMBLY), SHALL BE PROVIDED TO ACCOMMODATE INSTALLATION OF <br />THE AIR HANDLING UNITS AND DUCTWORK. THE EXTENT OF EXISTING AND NEW <br />FURR-DOWNS/BULKHEADS ARE INDICATED ON THIS DRAWING WITH DOT HATCH <br />PATTERNS; COORDINATE WITH THE ARCHITECTURAL DRAWINGS. <br />7. PROVIDE A HINGED ACCESS PANEL (WITH INTEGRAL RETURN AIR GRILLE) BELOW EACH <br />AIR HANDLING UNIT; MATCH EXISTING. <br />8. SUPPLY AIR REGISTERS (SR) SHALL BE US*AIRE MODEL 102M, OR EQUAL. <br />9. TRANSFER AIR GRILLES (TAG) SHALL BE US*AIRE MODEL 1400 (14%8"), OR EQUAL. <br />10. NEW EXHAUST AIR WALL CAPS SHALL MATCH EXISTING. <br />MECHANICAL KEY NOTES <br />O1 RELOCATED EXISTING A U (DAIKIN MODEL FXDQI2MVJU). <br />O2 THE RELOCATED EXISTING AEU (DAIKIN MODEL FXDQI 2MVJU) IN THIS REBUILT 1BR UNIT <br />TYPE IS CURRENTLY LOCATED IN APPROXIMATELY THE SAME LOCATION, AND SHALL BE <br />RELOCATED (IF REQUIRED) TO AVOID CONFLICT WITH THE NEW WALL. <br />OEXISTING AEU (DAIKIN MODEL FXDQI2MVJU). <br />OREMOVE THE INDICATED EXISTING DUCT(S) AND PATCH THE SUPPLY PLENUM AIR TIGHT. <br />OAPPROXIMATE LOCATION OF EXISTING AbU <br />ORELOCATED FROM EXISTING JANITOR CLOSET. <br />(E)WALL CAP <br />WALL CAP <br />REBUILT <br />STUDIO UNIT <br />ix <br />0 <br />c <br />1.4 <br />Im <br />oe <br />0 <br />U <br />VIL■ is <br />a <br />co <br />EF-1 <br />6"0 <br />— — _rl I Q E <br />R-8x4 71111111111" 5 (E)6"0 <br />�'� CFi� E L-XE) <br />r -i JANITOR / <br />- a I— I AHU C132(E) o O co/\ <br />4HU 114(R)O1 _ r — -� 6"0 <br />EXISTING ELEVATOR / <br />F-1 R) MACHINE ROOM <br />6 / <br />rT PARTIAL PLAN- <br />M400/ SCALE: 1/4" = 1'-0" <br />TYPICAL 113R UNIT / STUDIO UNIT PLAN <br />SCALE: 1 /4" = 1'-0" <br />cVEIGH & MANGUM <br />ENGINEERING•INC <br />340 Interstate North Parkway, Suite 360 <br />Atlanta - Georgia 30339 <br />Ph: (678)213-1616 Fax: (678)213-1617 <br />email: mail@McVeighMangum.com <br />of Record: Farshid Yarizadeh License No.: 40287 <br />FOUSE <br />.ARCHITECTURE <br />& INTERIORS, P.C. <br />3201 S. Cherokee Lane Suite 340 <br />Woodstock, Georgia 30188 <br />Voice 678-391-5365 <br />Fax 678-391-5362 <br />email: rlf@fousearchitecture.com <br />O Copyright 2011 Fouse Architecture & Interiors, P.C. <br />Seal: <br />Consultants: CIVIL ENGINEER: <br />STRUCTURAL ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Chad McDonald, P.E. <br />678.213.1616 <br />MEP ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Tony G. Fernandez, P.E. <br />678.213.1616 <br />r� Job Title: <br />V1 <br />0 <br />rw <br />rrTT,, <br />W d~ <br />a <br />C x <br />O AN <br />Sheet Information: <br />Job Number 11002 <br />Original Issue Date 08-31-2012 <br />Issue Dates: <br />No. ISSUE DATE <br />PERMIT/CONSTRUCTION 108-31-2012 <br />Sheet Title: <br />MECHANICAL <br />PARTIAL PLANS <br />Sheet: <br />M�400 <br />FOR CONSTRUCTION <br />