Laserfiche WebLink
In <br />12 <br />b <br />GENERAL PLUMBING NOTES <br />1. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS USED CERTAIN <br />ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING OF WHICH <br />ARE ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND. <br />2. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE <br />CAPACITY, SIZE, LOCATION, DIRECTION AND GENERAL ARRANGEMENT, BUT <br />NOT EXACT DETAILS OF CONSTRUCTION. THE FACT THAT ONLY CERTAIN <br />FEATURES OF THE INSTALLATION ARE INDICATED MUST NOT BE TAKEN TO <br />MEAN THAT OTHER FEATURES WILL NOT BE REQ'D. <br />3. COORDINATE WITH THE OTHER TRADES TO INSURE THAT EACH TRADE <br />SHALL HAVE SUFFICIENT SPACE TO INSTALL THEIR EQUIPMENT (DUCTWORK, <br />PIPING, ELECTRICAL WORK, ETC.). <br />4. EXISTING PIPING SHOWN WAS DERIVED FROM AS -BUILT DRAWINGS <br />PROVIDED TO ENGINEER. CONTRACTOR SHALL ANTICIPATE DEVIATIONS IN <br />ACTUAL CONDITIONS. <br />5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD <br />DIMENSIONS. <br />6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN. <br />7. PROVIDE STOP OR ANGLE VALVES ON EACH WATER CONNECTION TO EACH <br />PLUMBING FIXTURE. <br />8. PROVIDE ALL STRUCTURAL MEMBERS, SUPPORT BRACKETS, FLASHING, <br />HARDWARE, ETC. REQUIRED TO INSTALL A COMPLETE SYSTEM. <br />9. PROVIDE CHROME PLATED ESCUTCHEON PLATES AT ALL EXPOSED WALL <br />PENETRATIONS AND CEILING PENETRATIONS. <br />10. PROVIDE CLEANOUTS ON SANITARY LINES AND CONDENSATE DRAIN LINES <br />AS REQUIRED BY CODE. <br />11. PROVIDE ACCESS PANELS FOR ALL SHUT-OFF VALVES LOCATED ABOVE <br />GYP. BOARD CEILINGS. COORDINATE WITH G.C.. <br />PLUMBING LEGEND <br />— — <br />COLD WATER PIPE <br />— — — — — — <br />HOT WATER PIPE <br />— — — <br />HOT WATER RETURN PIPE <br />SOIL OR WASTE PIPE <br />— — <br />GREA5E WA5TE PIPE <br />— — — — — — — — <br />VENT PIPE <br />— <br />SODA/BEER LINES BELOW SLAB <br />- Q <br />TURNED UP <br />— - - -I--� <br />TURNED DOWN <br />— - �— <br />TEE, OUTLET DOWN <br />— - —Q-- - — <br />TEE, OUTLET UP <br />T&P <br />TEMPERATURE AND PRESSURE <br />RELIEF DRAIN PIPING <br />ED <br />EMERGENCY DRAIN PAN PIPING <br />GATE VALVE <br />PRESSURE RELIEF VALVE <br />BALL VALVE <br />FIXTURE <br />PLUMBING FIXTURE <br />DESIGNATION (UNDERLINED) <br />CONNECT NEW TO EXISTING <br />NOT ALL MAY BE USED. <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />BTU <br />BRITISH THERMAL UNIT <br />CONN <br />CONNECTION <br />CW <br />COLD WATER <br />ED <br />EQUIPMENT DRAIN <br />EXT'G <br />EXISTING <br />FCW <br />FILTERED COLD WATER <br />FL <br />FLOOR <br />FU <br />FIXTURE UNIT <br />GC <br />GENERAL CONTRACTOR <br />GPM <br />GALLONS PER MINUTE <br />HW <br />HOT WATER <br />IN <br />INCHES <br />MIN <br />MINIMUM <br />PC <br />PLUMBING CONTRACTOR <br />SAN OR S <br />SANITARY <br />V <br />VENT <br />VTR <br />VENT TO ROOF <br />WTR <br />WATER <br />W/ <br />WITH <br />W/o <br />WITHOUT <br />W <br />WASTE <br />DN <br />DOWN <br />HW <br />HOT WATER <br />HWR <br />HOT WATER RETURN <br />CO <br />CLEANOUT <br />WCO <br />WALL CLEANOUT <br />THW <br />TEMPERED HOT WATER <br />TP <br />TRAP PRIMER <br />PRV/BFP <br />PRESSURE REDUCING VALVE/ <br />BACKFLOW PREVENTER <br />NOT ALL MAY BE USED. <br />GENERALSYMBOLS <br />PLAN OR DETAIL NO. <br />SHEET NUMBER <br />O <br />KEYED NOTE NUMBER <br />QREVISION <br />NUMBER <br />BUILDING NORTH ARROW <br />PLUMBING FIXTURE SCHEDULE <br />CONNECTION SCHEDULE <br />DESIGNATION <br />MANUFACTURER <br />MODEL NO, <br />FIXTURE DESCRIPTION <br />WASTE <br />VENT <br />Ill <br />HW <br />P-1 <br />PEERLESS <br />766 <br />COMFORT HEIGHT (17" HIGH) VITREOUS CHINA WATER CLOSET <br />W/ ELONGATED BOWL, FLUSH TANK, 1.6 GPF, ADA COMPLIANT. <br />3" <br />2" <br />1/2" <br />-- <br />SEAT - SOLID PLASTIC, CLOSED FRONT, WITH COVER. <br />SUPPLY - 3/8" ANGLE -TYPE WITH STOP. <br />P-2 <br />PEERLESS <br />39 <br />VITREOUS CHINA OVAL COUNTERTOP LAVATORY (ADA COMPLIANT) <br />FAUCET - DELTA 22C131 (ADA COMPLIANT) <br />TRAP - 1 1 /4" CAST BRASS WITH C.O. PLUG <br />2" <br />2" <br />1 /2" <br />1 /2" <br />SUPPLY - 3/8" ANGLE -TYPE WITH STOPS <br />P-3 <br />SPURLIN INDUSTRIES <br />NF 60 3W L/R <br />SHOWER STALL, 60"x35"x8O" MOLDED FIBERGLASS SHOWER. <br />PROVIDE FULLY EQUIPED, COMPLETE WITH FAUCET (WITH PRESSURE <br />2" <br />2" <br />1 /2" <br />1 /2" <br />BALANCING MIXING VALVE), HAND-HELD SHOWER HEAD (W/24" SLIDE <br />BAR, VACUUM BREAKER & 60" HOSE), HORIZONTAL (L-SHAPED) & <br />VERTICAL STAINLESS STEEL GRAB BARS, FRAMELESS HDPE FOLD -UP <br />CUSHIONED SEAT, STAINLESS STEEL CURTAIN ROD, SOAP DISH, <br />BRASS DRAIN, AND SLIP RESISTANT TEXTURED BOTTOM. <br />P-4 <br />FIAT <br />MSB-2424 <br />24"x24"x10" MOLDED STONE MOP RECEPTOR. <br />3" <br />2" <br />1/2" <br />1/2" <br />FAUCET - T&S B-0665-BSTR <br />PIPE MATERIAL LIST <br />1. SANITARY, WASTE, AND VENT PIPING: FITTINGS SHALL BE LONG RADIUS FITTINGS, <br />EXCEPT FITTINGS IN VENT PIPING MAY BE SHORT RADIUS FITTINGS. CONTRACTOR <br />OPTIONS., <br />A. BELOW GRADE: SCHEDULE 40 PVC - DWV WITH DRAINAGE PATTERN FITTINGS. <br />B. ABOVE GRADE: SCHEDULE 40 PVC - DWV WITH DRAINAGE PATTERN FITTINGS, <br />2. DOMESTIC WATER PIPING CONTRACTORS OPTIONS: <br />A. ABOVE GRADE: SCHEDULE 80 CPVC. <br />PLUMBING TESTING AND DISINFECTING: <br />1. TESTING: <br />A. SOIL, WASTE, VENT SYSTEM: <br />1. TEMPORARILY PLUG ALL OUTLETS. <br />2. FILL LINES WITH WATER TO THE ROOF LEVEL. <br />3. ALLOW TO REMAIN FULL FOR 24 HOURS. <br />B. WATER SYSTEM: <br />1. TEST AT 150 PERCENT OF DESIGN PRESSURE BUT NOT LESS THAN 100 PSIG. <br />2. ALLOW PRESSURE TO REMAIN ON LINE FOR 24 HOURS. <br />C. REPAIR ALL DETECTABLE LEAKS IN PIPING SYSTEMS. <br />2. DISINFECTION OF DOMESTIC WATER SYSTEM: <br />A. DISINFECT DOMESTIC WATER SYSTEM AFTER APPROVAL OF TEST RESULTS AND PIPING <br />INSTALLATION BY BUILDING OFFICIAL. <br />B. PRIOR TO SUBSTANTIAL COMPLETION STERILIZE PIPING SYSTEM IN ACCORDANCE WITH LOCAL <br />PLUMBING CODE REQUIREMENTS. <br />C. DELIVER CERTIFICATION TO BUILDING OFFICIAL. <br />_ cVEIGH & MANGUM <br />ENGINEERING•INC <br />340 interstate North Parkway, Suite 360 <br />Atlanta - Georgia 30339 <br />Ph: (678)213-1616 Fax: (679)213-1617 <br />email: mail@McVeighMangum_com <br />of Record: Farshid Yarizadeh License No.: 40287 <br />FOUSE <br />ARCHITECTURE <br />& INTERIORS, P.C. <br />3201 S. Cherokee Lane Suite 340 <br />Woodstock, Georgia 30188 <br />Voice 678-391-5365 <br />Fax 678-391-5362 <br />email: rlf@fousearchitecture.com <br />© Copyright 2011 Fouse Architecture & Interiors, P.C. <br />Seal: <br />�N1D YA�j <br />` ay <br />0 <br />AT f 3! 2,, <br />RIO <br />21OINVAL ENGti <br />Consultants: CIVIL ENGINEER: <br />�1I�111 71. _1��►Le�J� <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Chad McDonald, P.E. <br />678.213.1616 <br />MEP ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Tony G. Fernandez, P.E. <br />678.213.1616 <br />Sheet Information. <br />Job Number 11002 <br />Original Issue Date 08-31-2012 <br />Issue Dates: <br />No.I ISSUE I DATE <br />I PERMIT/CONSTRUCTION 1 08-31-2012 <br />Sheet Title: <br />PLUMBING <br />LEGEND, <br />NOTES AND <br />SCHEDULE <br />Sheet: <br />Piiiiiiiiiiiiiiiioo_l <br />FOR CONSTRUCTION <br />