MECHANICAL PLAIN 1/4" = 11011 <br />NOTES: <br />MECHANICAL CONTRACTOR TO PROVIDE A RETURN AIR <br />GRILL FOR ALL ROOMS THAT HAVE A UNBALANCED AIR <br />FLOW PER FLORIDA MECHANICAL CODE OR UNDER CUT <br />DOORS <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />MECHANICAL CONTRACTOR TO VERIFY ALL DUCT <br />AND UNIT SITE. THE MECHANICAL DRAWINGS ARE <br />NOT A STRUCTURAL PART OF DRAWINGS AND MAY <br />VARY IN FIELD WITHOUT APPROVAL FROM ENGINEER <br />OF RECORD <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />3 - 2/0 THHN CU FEEDERS <br />2" GALV RISER <br />METER <br />SINGLE PHASE <br />BREAKER PANEL <br />WITH MAIN <br />200 AMP <br />GROUND PER N.E.G. <br />3- 2/0 06 GROUND <br />2" GALV NIPPLE <br />CONCRETE ENCASED "LIFER" <br />ELECTRODE REQUIRED PER <br />CURRENT N.E.C. AND MUST <br />BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT <br />ELECTRICAL LEGEND <br />220 V <br />G.F.I. 110 V <br />} GROUND FAULT <br />(� RECEPTACLE <br />1 <br />CEILING FAN <br />SWITCH <br />® IIOV 50 CFM'S <br />110 V <br />BATH FAN <br />WP <br />110 V <br />O� <br />WATERPROOF <br />IIOV LIGHT CEILING <br />FAN W/ LIGHT <br />OUTL <br />CAN BE CEILING <br />`D <br />OR WALL (TYP) <br />as <br />ON <br />e- CHANDLER EXTERIOR DBL FLOOD <br />FLUORESCENT <br />FIXTURE <br />O O <br />O VANITY LIGHT <br />CAN LIGHT <br />O <br />�yRECESS <br />I�J ELECTRICAL PANEL <br />WALL SCONCE <br />SMOKE <br />DETECTOR <br />TELEVISION <br />C3.D.B.. <br />OCARBON <br />C <br />MONOXIDE <br />® PHONE <br />l'f <br />UNIT <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN h' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />ALL REMAINING OUTLETS IN HOME TO WIRED INTO A ARC -FAULT INTERRUPTER "AFI" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN 10'O" OF EACH ROOM USED FOR SLEEPING PURPOSES <br />WHEN BUILDING HAS A FOSSIL FUEL BURNING HEATER OR APPLIANCE, A FIREPLACE OR AN ATTACHED <br />GARAGE . <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />GENERAL LOADS <br />TYPE OF LOAD <br />LIGHTING LOAD 2014 SQ FT X 3VA 6042 <br />SMALL APPLIANCE LOAD 2 CIRCUITS X 1500VA 3000 <br />LAUNDRY LOAD I CIRCUITS X 1500VA 1500 <br />TOTAL VA 10542 <br />LOAD <br />LIGHTING, SMALL APPLIANCE, <br />LAUNDRY FIRST 3000VA X 100 % TOTAL 3000 vA <br />LIGHTING, SMALL APPLIANCE <br />LAUNDRY REMAINING '1542 VA X 35 9; TOTAL 2640 VA <br />TOTAL 5640VA <br />LARGE APPLIANCE LOADS <br />ELECTRIC RANGE NOT OVER 12 KVA <br />8000 VA <br />CLOTHES DRYER <br />5500 VA <br />WATER HEATER <br />4500 VA <br />HVAC HEAT <br />5000 VA <br />TOTAL 23000 VA <br />TOTAL VA 28640 VA <br />CONVERT VA TO AMPS <br />28640 DIVIDED BY 240 VOLTS - 120 AMPS <br />ELECTRICAL PLAN 1/4" = 110" <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS <br />RICHARD L. KIDDEY E p <br />FLORIDA LICENSE MBER 3mErly <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2014 5TH EDITION AND ASCE 1-10 <br />FOR 139 MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2014 BUILDING CODE RESIDENTIAL 5T14 EDITION <br />CM <br />C'4 <br />z <br />ZU� <br />M <br />WO <br />O <br />C7 o N <br />Z LL co <br />Q <br />Z <br />n cLo <br />J W <br />Q <br />z <br />� <br />LL <br />W � ti <br />W <br />A <br />cccl)o o <br />(L N <br />in <br />a 0) 1 <br />Z 1p 04 <br />cr) <br />Q w <br />W <br />Q <br />?� U <br />� = ti <br />w u? p <br />o � <br />� r <br />00 <br />M <br />rr <br />�MN <br />CISIll m <br />1 � <br />� <br />m 13 <br />cmn(z(� <br />FL <br />z <br />to <br />z Q) <br />713 <br />T �o <br />zoo <br />Lu <br />p�ui <br />^ Q) <br />to <br />V <br />VI 1 L <br />715 M <br />LU Q LL -� <br />w Q) <br />dJ ° 9 <br />W <br />0 <br />_p <br />111 <br />N <br />O <br />9 <br />z <br />Q <br />ED <br />z <br />LU W <br />iF O <br />O <br />w <br />VI <br />LIVING <br />1410 <br />GARAGE <br />402 <br />PORCW <br />202 <br />TOTAL 2014 <br />PC-S <br />4OF5 <br />ARKAY 0 <br />16754 <br />