GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2014 FLORIDA BUILDING CODE <br />5T14 EDITION AND THE 2014 FLORIDA BUILDING CODE - RESIDENTIAL 5 TH EDITION, <br />ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOORS: GARAGE SLAB: <br />LIVE LOAD - 40 P,S,F. LIVE LOAD - 50 P.S..F, <br />DEAD LOAD - 10 P.S.F. DEAD LOAD - 10 P,S,F, <br />ROOF: <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P,S,F, <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P,S,F, <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2014 FLORIDA <br />BUILDING CODE, RESIDENTIAL 5TH ADDITION - SECTION R301.2,1.1. AND 20!4 FLORIDA BUILDING <br />CODE 5TH ADDITION SECTION 1609.1.1, <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT t EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602,5 <br />COMPONENT t CLADDING WIND LOADS <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35,3 <br />2 <br />405.1 <br />+32,3/-56.2 <br />3 <br />-110,ro <br />+32.3/-89,0 <br />4 <br />N/A <br />+35.3/-38,2 <br />5 <br />_r <br />N/A <br />+35.3/-41,2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P,S,F, <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED t COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P,S,F, <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC,: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING, <br />ARKAY ENGINEERING, INC, SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS 4 SLAB —ON —GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA, <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P,S,I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR Oro REBAR t 35" FOR 01 REBAR, <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED, <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />MASONRY WALLS: <br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 <br />AND SHALL HAVE A MINIMUM F'M OF 1,500 P,S,I, <br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S, <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615, LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR M6 REBAR t 35" FOR 01 REBAR, <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/6", PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />OF 2,500 P.S.I, (WHEN TESTED PER ASTM C-1019), <br />PROVIDE CLEAN -OUT OPENINGS (12 50, IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />LVL BEAMS SHALL BE (LSE) MICROLLAM LVL MATERIALS MANUFACTURED BY TRUSJOIST <br />MACMILLAN (OR EQUAL), <br />LUMBER UTILIZED IN BOTTOM PLATES, TOP PLATES, POSTS, STUD PACKS AND BEAMS <br />SHALL BE #2 YELLOW PINE (OR BETTER). <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE 02 SPRUCE (OR BETTER). <br />ALL OTHER STUDS SHALL BE "STUD GRADE" SPRUCE. <br />PSL POSTS SHALL BE 11.8E) PARALLAM PSL MATERIALS MANUFACTURED BY TRUSSJOIST <br />MACMILLAN (OR EQUAL). SEE "POST SUPPORT TABLE" ON THIS SHEET FOR LOAD VALUES. <br />EXTERIOR WALLS SHALL BE CONSTRUCTED WITH 1/2" PLYWOOD OR 1/16 O.S.B. (2-M-W RATING) NAILED <br />WITH SD NAILS SPACED AT 3" O.C. ALONG ALL HORIZONTAL JOINTS t EDGES. 6" O.G. ALONG ALL <br />VERTICAL JOINTS t EDGES AND 12" O.G. ALONG ALL INTERMEDIATE STUDS. <br />AT OPENINGS 5'-O" WIDE OR LARGER, STRAP HEADER BEAM TO THE HEADER STUDS WITH (2) USP OR SIMPSON <br />"LSTA24" STRAP TIES AT EACH END OF HEADER BEAM, ANCHOR BOTTOM OF HEADER STUDS TO FOUNDATION <br />WITH A USP OR SIMPSON "HTTIfc" TENSION TIE. <br />ANCHOR WOOD SHEARWALL SEGMENTS TO FOUNDATION WITH A USP OR SIMPSON "HTTI6" TENSION TIE AT EACH <br />END OF WALL SEGMENTS AND AT ANY WALL SEGMENT INTERSECTIONS (BUILDING CORNERS), <br />ANCHOR TRUSSES AS FOLLOWS: <br />ROOF UPLIFTS OF 4550 AND LESS USE (1) USP "RT3" OR SIMPSON "143" HURRICANE TIE. <br />FOR UPLIFTS FROM 4560 UP TO 9100 USE (2) USP "RT3" OR SIMPSON "143" HURRICANE TIES. <br />UPLIFTS FROM 911" UP TO 1,4500 USE A USP "HTW20" OR SIMPSON "HTS20" TWIST STRAP. <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION, <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />'USP" OR "SIMPSON" CONNECTORS SHOWN, <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P,T, <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC, WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />d <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES, THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />IF A REGISTERED TERMITICCE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />ABOVE DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR, THE SYSTEM <br />MUST HE INSTALLED PRIOR TO FINAL BUILDING APPROVAL, <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING t COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE t DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT, <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION), ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING, THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS ARKAY ENGINEERING, INC, IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW t GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/I62 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY, <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE, <br />INSTALL ALL WINDOW t DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />ELECTRICAL, PLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411,003(2XU OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES, THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS, <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN (2 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT, <br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"AFI" CIRCUIT, <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET, <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN S SQ. FT, <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR, <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />DRAFTSTOPPING: <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES, DRAFTSTOPPING <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ. FT. <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ. FT, AND HAVING MINIMUM <br />30 INCHES OF VERTICAL HEIGHT, ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES, <br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305.1,3 <br />GARAGE: <br />NO OPENINGS SHALL BE PERMITTED FROM A GARAGE INTO A SLEEPING ROOM, OTHER OPENINGS <br />BETWEEN THE GARAGE AND RESIDENCE SHALL HAVE A DOOR (MIN. 1 3/5" THICK), OF SOLID WOOD, <br />SOLID OR HONEYCOMB CORE STEEL, OR 20-MINUTE FIRE -RATED WITH SELF CLOSING HINGES, <br />WALLS SEPARATING THE GARAGE AND RESIDENCE SHALL HAVE MIN. 1/2" GYPSUM BOARD <br />APPLIED TO THE GARAGE SIDE, THE CEILING SHALL HAVE MIN. 1/2" GYPSUM BOARD APPLIED <br />TO THE GARAGE SIDE, GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY ALL <br />HABITABLE ROOMS ABOVE WITH MIN. 5/8" 'TYPE-X' GYPSUM BOARD IN COMPLIANCE WITH THE <br />FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R309 <br />PRODCCT CATEGORY <br />APPROVED PRODUCT LIST <br />SUB CATEGORY MANUFACTURER <br />STATE FL, <br />APPROVV AL <br />STRUCTURAL COMPONET <br />HIO <br />SIMPSON <br />FL 10456 <br />STRUCTURAL COMPONET <br />AC6 <br />SIMPSON <br />FL 10860 <br />STRUCTURAL COMPONET <br />A5U6fo <br />SIMPSON <br />FL 10860 <br />STRUCTURAL COMPONET <br />WALL ANCHORS <br />THREADED ROD <br />N/A <br />ROOFING <br />ASPHALT <br />GAF SINGLES ALL <br />FL 10124.1 <br />ROOFING <br />UNDERLAYMENT <br />GAF <br />FL 10626.1 <br />SOFFIT t FASCIA TRIM <br />SOFFIT AMERICAN <br />CONSTRUCTION METALS <br />FL 12019.1 <br />SINGLE HUNG <br />WINDOWS <br />NON IMPACT <br />PLYGEM 1500 <br />FL 16103.1 <br />EXTERIOR DOORS <br />GARAGE 9'2" TO 16'2" <br />CLOPAY <br />FL 5684.3 <br />EXTERIOR DOORS <br />SWINGING 8'0" <br />PLAST PRO <br />FL 15213,30 <br />EXTERIOR DOORS <br />SWINGING &'0" <br />PLAST PRO <br />FL 15213.19 <br />WALL SIDING <br />EXTERIOR <br />WARDI BOARD <br />FL 13192,1 <br />LAP SIDING <br />0 OII Q/ I OII <br />V <br />TYPICAL ROOF TRUSSES <br />. - - - - - - ,- - - - - -.r - - - - -,r - - - - -.r - - - - -.r - - - - - n - - - - - n - - - - - n - - - - n - - - - - - <br />TYPICAL STUDS ,- - - - - •+.- - - - �,- - - - - �,- - - - - �,- - - . <br />11 II II 11 11 II II II II II II 11 II II 11 <br />11 II II 11 it II II II 11 II II 11 II II II <br />11 11 II II I' II II 11 II II II " II II 11 <br />II II II II II II II II II II II '' 11 II II <br />11 II II 11 11 11 II II " II II II <br />n " " TYPICAL DOUBLE TOP PLATE <br />II II II II II 11 II II <br />SPACED 16" OG I I I I 11 I I I I I I 11 I I I I <br />1/2" HEX NUT WITH 1/2" HEX NUT WITH 11 II II <br />SQUARE WASH 11 I I I I 11 11 11 I I I I I I 11 11 SQUARE WASHER 1II1 11 u <br />11 II II 11 -11 - II II II II II <br />11 II II I 11 II 11 II II I II �� II II II <br />Il II II I 11 II II II II I II II 11 II II <br />11 II II 11 11 II II II II II II II II II <br />1/2" A30- <br />THREAD <br />5/8" xl" REDHE <br />EXPANSION Bc <br />11 II II 11 <br />11 II II II <br />11 II II II <br />n n n n <br />II II II II <br />n 11 n n <br />n 11 n n <br />II 11 n n <br />n 11 n n <br />n 11 n n <br />n II n II <br />n n n 11 <br />n 11 n 11 <br />II 11 n 11 <br />All I <br />ALL <br />ROD <br />L <br />4D <br />>LTS <br />CONCRETE <br />SLAB <br />TYPICAL <br />BOTTOM <br />PLATE <br />SINGLE <br />I <br />1 STORY ALL THREAD ROD ANCHOR DETAIL <br />NOT TO SCALE <br />A301 ALL THREAD ROD ROD SYSTEM FROM <br />SLAB TO TOP PLATE PLACED (1) AT EACH <br />CORNER AND AT MAXIMUM &'0" OC ON <br />PERIMETER OF HOUSE <br />ARKAY ENGINEERING INC.. 1 <br />STRUCTURAL ENGINEERS <br />a <br />RICHARD L. KIDDEY E. <br />FLORIDA LICENSE MBER 3.1296 <br />I HERBY CERTIFY THAT THESE NS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION i609 OF THE <br />FLORIDA BUILDING CODE 2014 5TH EDITION AND ASCE 1-10 <br />FOR 13S MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2014 BUILDING CODE RESIDENTIAL 5T14 EDITION <br />U <br />Z 10 <br />Z <br />Z <br />0.0 <br />O <br />C7 M <br />W Q 0 <br />CD <br />0 N <br />cc <br />01 <br />Z ULL co <br />>m <br />zm <br />_ju4 <br />m U M <br />J W <br />0.0 <br />U_ <br />z <br />W <br />w co <br />A <br />Q N <br />>_ N <br />19 <br />o m <br />Z co 04 <br />Q M <br />J UJ <br />Q U <br />1" = U_ <br />LL <br />W O <br />a :5 <br />55 1, <br />CD <br />CM <br />rr <br />>n�01 <br />N <br />cow``' <br />cn c <br />1 � <br />m cc <br />mcAto <br />U <br />z <br />' W L <br />Z Q) <br />4 o <br />Q) LL <br />0 <br />ZQ)� <br />Q) <br />- <br />Z <br />Qf <br />L <br />i <br />I+ <br />Q O L n <br />Q) <br />V <br />it) <br />Q/ fa <br />Q1 CZ70-U <br />L <br />M 1 <br />W Q LL <br />Id3 0 <br />Q)LL) s <br />o� <br />N ff <br />W <br />'Q <br />0 <br />Z <br />!!l <br />rQ <br />N <br />� <br />� <br />Z <br />Q <br />Q <br />W. <br />w O <br />O <br />tu <br />0— <br />LIVING <br />1410 <br />GARAGE <br />402 <br />PORCH <br />202 <br />TOTAL 2014 <br />PG <br />✓Or-5 <br />ARKAY N <br />16754 <br />