DISABLED ACCESS NOTES I GENERAL NOTES
<br />1. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL
<br />THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER
<br />ELEVATORS OR SPECIAL ACCESS LIFTS.
<br />2. FLOOR SURFACES SHALL BE SLIP -RESISTANT.
<br />3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE
<br />NOT LESS THAN 44" IN WIDTH.
<br />4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN
<br />HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH
<br />A SLOPE NO GREATER THAN 1:2
<br />5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH
<br />OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE,
<br />PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO
<br />PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING
<br />HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR
<br />FINISH.
<br />6. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS
<br />FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT
<br />ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS.
<br />CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET
<br />THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE
<br />INCREASED NOT TO EXCEED 15 POUNDS.
<br />7. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A
<br />SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEEL
<br />CHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A
<br />10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS.
<br />8. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3' IN
<br />WIDTH AND NOT LESS THAN 6-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT
<br />LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE
<br />DOORWAY IS NOT LESS THAN 32".
<br />9. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A
<br />CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN
<br />ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
<br />10. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH
<br />ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING
<br />PEDESTRIAN WAYS.
<br />11. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE
<br />LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE
<br />DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE
<br />DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF
<br />THE DOOR IN ITS CLOSED POSITION. (REFER TO DWG. 2/A00.40 FOR CLEARANCES BASED
<br />ON DIFFERENT APPROACHES)
<br />12. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF
<br />THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A
<br />SLOPE NO GREATER THAN 1:2.
<br />13. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD
<br />OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2"
<br />WIDE, PLACED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR
<br />LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS
<br />THE OTHER TREADS OF THE STAIR.
<br />14. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" ABOVE THE FLOOR OR
<br />WORKING PLATFORM.
<br />15. ENTRY TO SANITARY FACILITIES:
<br />A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE.
<br />B. DOORWAYS TO HAVE A 32" CLEAR OPENING.
<br />C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS
<br />TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH.
<br />(REFER TO DWG 2/A00.40 FOR CLEARANCES BASED ON DIFFERENT APPROACHES)
<br />16. TOILET ROOM ACCESSORIES
<br />A. MOUNT BOTTOM EDGE OF MIRROR'S REFLECTING SURFACE NO HIGHER THAN 40" FROM
<br />THE FLOOR.
<br />B. MOUNT TOILET TISSUE DISPENSERS WITHIN 7"-9" FROM THE FRONT EDGE OF THE
<br />TOILET SEAT.
<br />C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE,
<br />COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR.
<br />17. SINGLE ACCOMMODATION TOILET FACILITY SEE 5/A00.41 FOR CLEARANCE REQUIREMENTS
<br />18. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17" AND 19".
<br />19. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF
<br />THE TOILET WITH THE GREATEST SEPARATION FROM ADJACENT WALL OR OTHER
<br />SURFACE.
<br />20. PROVIDE GRAB BARS ON EACH SIDE, OR ONE SIDE AND BACK OF WATER CLOSET.
<br />A. GRAB BARS TO BE 33" ABOVE AND PARALLEL TO THE FLOOR.
<br />B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL.
<br />GRAB BAR AT BACK TO BE 36" LONG.
<br />C. DIAMETER OF GRAB BARS TO BE 1-1/4" TO 1-1/21'
<br />.
<br />D. PROVIDE 1-1/2" CLEARANCE BETWEEN GRAB BARS AND WALL.
<br />E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL
<br />SUPPORT A 250 POUND LOAD.
<br />F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
<br />G. GRAB BARS AND ANY ADJACENT SURFACE SHALL BE FREE OF SHARP OR ABRASIVE
<br />ELEMENTS.
<br />H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8
<br />21. PROVIDE A CLEAR FLOOR SPACE 30" X 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD
<br />APPROACH.
<br />22. MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE
<br />BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT UP EXTENDING A
<br />MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH, AND SHALL BE A MINIMUM OF 9"
<br />HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY.
<br />23. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND
<br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE
<br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER
<br />OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES
<br />OF ACCEPTABLE DESIGNS. IF SELF CLOSING VALVES ARE USED, FAUCET REMAINS OPEN A
<br />MINIMUM OF 10 SECONDS.
<br />24. INSULATE OR OTHERWISE COVER HOT WATER AND DRAIN PIPES UNDER LAVATORIES.
<br />25. THE AMERICANS WITH DISABILITIES ACT (A.D.A.) PROVIDES THAT ALTERATIONS TO A
<br />FACILITY MUST BE MADE IN SUCH A MANNER THAT, TO THE MAXIMUM EXTENT FEASIBLE,
<br />THE ALTERED PORTIONS OF THE FACILITY ARE READILY ACCESSIBLE TO INDIVIDUALS
<br />WITH DISABILITIES. BANK AND GENERAL CONTRACTOR ACKNOWLEDGES THAT THE
<br />REQUIREMENTS OF A.D.A. WILL BE SUBJECT TO VARIOUS AND POSSIBLY CONTRADICTORY
<br />INTERPRETATIONS. THE ARCHITECT THEREFORE, WILL USE ITS BEST PROFESSIONAL
<br />EFFORTS TO INTERPRET A.D.A. REQUIREMENTS AND OTHER FEDERAL, STATE AND LOCAL
<br />LAWS, RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THE PROJECT.
<br />THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT BANK
<br />OF AMERICA WILL COMPLY WITH ALL INTERPRETATIONS OF THE A.D.A. REQUIREMENTS
<br />AND/ OR THE OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND
<br />REGULATIONS AS THEY APPLY TO THE PROJECT.
<br />26. THE SCOPE OF WORK INDICATED ON THESE DRAWINGS IS FOR SPECIFIC ITEMS SELECTED
<br />BY BANK OF AMERICA FOR CUSTOMER ACCESS TO GOODS AND SERVICES; NOTE THAT SOME
<br />AREAS OF ACCESS HAVE NOT BEEN MODIFIED TO MEET A.D.A. REQUIREMENTS. ALL OTHER
<br />AREAS OF A.D.A. UPGRADE THAT MAY BE REQUIRED AT THIS TIME ARE NOT IN THIS
<br />CONTRACT AND ARE NOT INDICATED ON THESE DOCUMENTS. SEE BANK OF AMERICA FOR
<br />ADDITIONAL INFORMATION CONCERNING OTHER AREAS OF A.D.A. SCOPE OF WORK.
<br />1. ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (A.D.A.) ALONG
<br />WITH ALL STATE, COUNTY, AND LOCAL APPLICABLE CODES, ORDERS, ORDINANCES AND
<br />REGULATIONS. NOTIFY ARCHITECT PRIOR TO START OF WORK OF ANY DISCREPANCIES
<br />BETWEEN THE DRAWINGS AND CODE. ALL WORK SHALL CONFORM TO THE MOST
<br />RESTRICTIVE REQUIREMENT.
<br />2. BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME FAMILIAR WITH DRAWINGS
<br />SCOPE OF WORK AND VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE SITE AND
<br />NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
<br />3. PRIOR TO STARTING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT TO BANK OF
<br />AMERICA PROJECT MANAGER AND ARCHITECT AN ITEMIZED COST BREAKDOWN OF ALL
<br />SCOPE ITEMS AND A CONSTRUCTION SCHEDULE. WORK TO BE SCHEDULED TO MEET BANK
<br />OF AMERICA REQUIREMENTS.
<br />4. ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND ALL WORK DEPENDENT
<br />UPON OR NECESSARY TO COMPLETE THIS WORK SHALL BE EXECUTED IN A WORKMAN LIKE
<br />MANNER CONSISTENT WITH THE BEST STANDARDS OF THE TRADE INVOLVED AND BE OF
<br />ITEMS AND MATERIALS SUITED FOR THE PURPOSE INTENDED.
<br />5. TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN, AND SUPERVISORS ARE TO BE SKILLED,
<br />EXPERIENCED AND LICENSED IF REQUIRED IN THE WORK THEY WILL BE PERFORMING.
<br />6. PROJECT CONSTRUCTION ITEMS TO BE NEW, UNLESS OTHERWISE NOTED. NO
<br />SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE DESCRIPTIONS OF ITEMS INCLUDING
<br />DRAWINGS, TEST DATA, SAMPLES, COST AND SCHEDULE CHANGES ARE SUBMITTED BY THE
<br />CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. ANY ITEM
<br />NOTED ON THE DRAWINGS THAT ARE NOT AVAILABLE OR WOULD CAUSE A TIME DELAY
<br />SHALL BE IDENTIFIED BY THE GENERAL CONTRACTOR AND THE ARCHITECT NOTIFIED.
<br />7, TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLICABLE U.N.O. ALL
<br />SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION
<br />STANDARDS, IF CONTRACTOR HAS ANY QUESTIONS REGARDING THE SAME OR EXACT
<br />MEANING, ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION.
<br />8. DIMENSION LINES ARE TO FACE OF FINISH ON EXISTING AND NEW WORK, UNLESS NOTED AS
<br />FACE OF STUD OR MASONRY OR CENTERLINE OR OTHERWISE. DIMENSIONS SHALL HAVE
<br />PRECEDENCE OVER SCALE AND LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER
<br />SMALLER SCALE DRAWINGS.
<br />9. PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL FABRICATION OR WHERE
<br />THEY ARE CALLED OUT FOR ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL
<br />SUBMIT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. REQUIRED
<br />CORRECTIONS WILL BE NOTED AND A COPY WILL BE RETURNED TO THE CONTRACTOR WHO
<br />SHALL REVISE DRAWINGS AND RESUBMIT FOR FINAL APPROVAL PRIOR TO FABRICATION.
<br />10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO ARCHITECT FOR APPROVAL
<br />PRIOR TO INSTALLATION.
<br />11. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS -BUILT DRAWINGS NOTING
<br />DEVIATIONS BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS AND NEW
<br />CONSTRUCTION OF ALL TRADES AND DELIVER TO BANK OF AMERICA AT END OF PROJECT.
<br />GENERAL CONTRACTOR SHALL PROVIDE ALL SUBCONTRACTORS WITH THE MOST CURRENT
<br />CONSTRUCTION DOCUMENTS THROUGHOUT THE PROJECT, INCLUDING ALL REVISIONS.
<br />12. CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA PROJECT MANAGER OF ALL
<br />REVISIONS TO THE DRAWINGS AND CHANGES WITH THE SCOPE OF WORK OR SCHEDULE
<br />REQUIRED BY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF AMERICA PERSONNEL
<br />REGARDLESS OF EXTENT, ALL REVISIONS TO BE IN WRITING AS CHANGE ORDERS AND
<br />APPROVED PRIOR TO STARTING WORK.
<br />13. CONTRACTOR TO PROVIDE EQUIPMENT TO ENSURE LIFE SAFETY OF PUBLIC, TENANTS AND
<br />WORKERS AS REQUIRED BY FEDERAL, STATE AND LOCAL CODES THROUGHOUT
<br />CONSTRUCTION. CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT
<br />PEDESTRIANS.
<br />14. CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND REQUIREMENTS OF NEW
<br />CONSTRUCTION PRIOR TO START OF WORK. CONTRACTOR SHALL FURNISH ADEQUATE
<br />SHORING, BRACING, ETC., AS REQUIRED TO SAFELY EXECUTE ALL WORK AND SHALL BE FULLY
<br />RESPONSIBLE FOR SAME, UNLESS SPECIFICALLY DETAILED IN THE DRAWINGS. CONTRACTOR
<br />SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORTS AS
<br />NECESSARY FOR ALL FIXTURES, EQUIPMENTS AND ALL OTHER ITEMS REQUIRING SAME.
<br />FIRE DEPARTMENT NOTES
<br />1. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON
<br />DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT
<br />INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO
<br />EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES.
<br />2. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS.
<br />3, EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY
<br />OR ANY SPECIAL KNOWLEDGE OR EFFORT, SPECIAL LOCKING DEVICES SHALL BE OF AN
<br />APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES.
<br />4. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE -RESISTIVE CORRIDORS SHALL BE
<br />PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING
<br />AND SHALL BE SELF -CLOSING.
<br />5. 20-MINUTE DOOR JAMBS TO BE TIGHT -FITTING, SMOKE AND DRAFT CONTROLLED.
<br />6. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE
<br />PERSONS AND IN ANY HAZARDOUS AREA.
<br />7. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END
<br />POINT FLAME SPREAD RATING:
<br />A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN
<br />VERTICAL EXITS.
<br />B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN
<br />HORIZONTAL EXITS.
<br />C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED
<br />IN ANY OTHER LOCATION.
<br />15. SITE AND BUILDING SHALL BE MAINTAINED IN A CLEAN, SAFE MANNER. DIRTY/ NOISY
<br />WORK SHALL BE PERFORMED AT SUCH TIME AS DIRECTED PER THE OWNER AND/OR CITY
<br />WHEN THE WORK OF VARIOUS SECTIONS ARE COMPLETED, AND AT OTHER TIMES AS
<br />DIRECTED BY BANK OF AMERICA, OR OWNER, ALL TRASH. DEBRIS, SURPLUS MATERIAL,
<br />TOOLS AND EQUIPMENT ARE TO BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL
<br />MANNER. LEAVE PREMISES IN A CONDITION ACCEPTABLE TO BANK OF AMERICA, OR OWNER.
<br />16. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. WHERE EXISTING
<br />CONSTRUCTION, FINISHES OR EQUIPMENT IS DAMAGED BY WORK IN THIS CONTRACT,
<br />THEY SHALL BE PATCHED, REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING, BY
<br />TRADE WHOSE WORK IS DAMAGED AT NO COST TO BANK OF AMERICA.
<br />17. LAYOUT OF WORK:
<br />A. LOCATION AND ELEVATION OF ALL WORK TO BE CONSTRUCTED ARE SHOWN ON
<br />DRAWINGS AND UNLESS DISCREPANCIES ARE BROUGHT TO THE ATTENTION OF THE
<br />ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR
<br />THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND INTENDED.
<br />B. THE CONTRACTOR SHALL LAYOUT THE WORK AND SHALL ESTABLISH AND MAINTAIN
<br />NECESSARY MARKERS, AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF SAME. THE
<br />CONTRACTOR SHALL LAYOUT, AS A GUIDE TO ALL TRADES AND TO HIS SUBCONTRACTORS,
<br />THE EXACT LOCATIONS OF NEW OR REMODEL WORK WITH RESPECT TO CHANGES TO
<br />EXISTING.
<br />18. INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC. INCLUDING THE
<br />PREPARATION OF SURFACES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED
<br />RECOMMENDATIONS AND INSTALLATION REQUIREMENTS.
<br />19. PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL
<br />AND RELOCATION OF ANY EXISTING EQUIPMENT OR CONSTRUCTION AS NECESSARY FOR A
<br />COMPLETE INSTALLATION.
<br />20. ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT SWITCHES, VALVES AND OTHER
<br />CONTROL DEVICES THAT ARE CONCEALED. EXACT LOCATIONS TO BE APPROVED BY
<br />ARCHITECT PRIOR TO INSTALLATION.
<br />21. BESIDES GUARANTEES REQUIRED ELSEWHERE, THE CONTRACTOR, HEREBY DOES,
<br />GUARANTEE ALL WORK FOR A MINIMUM PERIOD OF ONE YEAR AFTER DATE OF ACCEPTANCE
<br />OF WORK WITH ANY OTHER WORK, WHICH MAY BE DISPLACED IN SO DOING, THAT MAY
<br />PROVE DEFECTIVE IN WORKMANSHIP AND/OR MATERIALS WITHIN A MINIMUM OF ONE
<br />YEAR PERIOD FROM THE DATE OF ACCEPTANCE WITHOUT EXPENSE TO BANK OF AMERICA.
<br />22.OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES
<br />GOVERNING THE WORK.
<br />23. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR
<br />REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
<br />24. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT.
<br />INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND
<br />COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION.
<br />25. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS.
<br />26. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
<br />27. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT,
<br />CONSULT THE ARCHITECT.
<br />28. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR
<br />MOUNTED TO WALLS OR CEILINGS.
<br />29. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE
<br />NOTED.
<br />30, CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME
<br />SPREAD INDEX OF NOT MORE THAN 75 AND A SMOKE -DEVELOPED INDEX OF NOT MORE
<br />THAN 450.
<br />31, INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL FIRE
<br />ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN UNCONCEALED SPACES SHALL
<br />HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF
<br />NOT MORE THAN 450.
<br />32. MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NONCOMBUSTIBLE OR SHALL
<br />HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF
<br />NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84.
<br />8. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS
<br />OR CEILINGS.
<br />9. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE
<br />REQUIREMENTS.
<br />10. HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT
<br />MORE THAN 60 FLASHES PER MINUTE AND SHALL BE SYNCHRONIZED.
<br />11. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE
<br />FINISHED FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.
<br />12. CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL PROTECTED OPENINGS, CORRIDOR
<br />PARTITIONS, SMOKE STOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT
<br />ENCLOSURES AND ALL FIRE RATED WALLS WITH CORRESPONDING HOURLY RATING BY
<br />EITHER INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE FOLLOWING:
<br />"1 HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS". NOTE: IDENTIFICATION
<br />SHALL BE SPACED NO MORE THAN TWELVE (12) FEET ON CENTER WITH A MINIMUM
<br />LETTER SIZE OF TWO (2) INCHES IN HEIGHT ON A CONTRASTING BACKGROUND.
<br />13. DEVICE COVERS TO BE TO MATCH LUTRON LIGHT ALMOND UNLESS DICTATED
<br />OTHERWISE BY LOCAL JURISDICTIONS.
<br />Bank of America
<br />ADA- ZEPHYRHILLS
<br />5632 GALL BOULEVARD
<br />ZEPHYRHILLS, FL 33542
<br />SERIAL NUM./MANH. ID: FL2-019
<br />� 'I
<br />Nelco Architecture, Inc.
<br />a licensed affiliate
<br />Florida Certificate of Authorization Number: AA26000525
<br />Architect: Client Representative:
<br />Firm Name: NELSON Firm Name: JLL
<br />Attn: Mark Schroeder Attn: Lisa Drees
<br />T: 404.881.1811 T: 813.624.4512
<br />e-mail: mschroeder@nelsononline.com e-mail: lisa.drees@am.jll.com
<br />Engineering:
<br />Infinity Engineering Group, LLC
<br />Attn: Nisit Sapparkhao
<br />T: 813.830.2330
<br />e-mail: nisit@iegroup.net
<br />General Contractor:
<br />Firm Name: Spartan Contracting Corporation
<br />Attn: Scott Kramer
<br />T: 813.481.5778
<br />e-mail: skramer@spartancc.com
<br />Issue Date & Issue Description By Check
<br />1 03/23/18 Issue For Review AJB AFO--
<br />2 04/23/18 Issue For CD Review KS AFO/MS
<br />3 04/27/18 Issue For Permit KS MS
<br />Seal/Signature
<br />Architect of Record, Mark Schroeder
<br />Lic. # : AR0016438
<br />Project Name
<br />Bank of America
<br />Zephyrhills
<br />IProject Type
<br />ADA Upgrade
<br />NELSON
<br />1� 8 003
<br />Number
<br />IDescription
<br />GENERAL NOTES
<br />IScale & Sheet Number
<br />A00olO