DOOR, FRAME AND HARDWARE GROUP SCHEDULE <br />SHEET NOTES <br />DOOR <br />FRAME <br />HARDWARE <br />A. <br />ALL DOORS AND FRAMES ARE TO MATCH EXISTING DOORS AND FRAMES FOR TYPE AND FINISHES, U.N.O. <br />FIRE <br />B. <br />ALL NON RATED DOORS SHALL BE WOOD, SOLID CORE, 5 PLY, HARDWOOD VENEER STILES AND RAILS, U.N.O. <br />ROOM NAME <br />SIZE <br />DETAIL <br />GROUP <br />KEYSIDE <br />NOTES <br />C. <br />FRAMES SHALL BE WOOD OR HOLLOW METAL FRAMES FINISHED TO MATCH EXISTING DOOR FRAMES, UNO. AT HOLLOW METAL FRAMES, CAULK THE <br />NO. <br />MATL <br />FINISH <br />TYPE <br />MATL <br />FINISH <br />LABEL <br />JOINT BETWEEN THE FRAME AND WALL, ALL SIDES, WITH PAINTABLE LATEX CAULK. <br />NO. <br />RM NO. <br />D. <br />PROVIDE A 1/2" MAXIMUM UNDERCUT. VERIFY SLAB CONDITIONS AND TRIM EACH DOOR TO AT CONDITION. <br />WIDTH <br />HEIGHT <br />THK. <br />HEAD <br />JAMB <br />SILL <br />E. <br />DOORS AND HARDWARE ARE TO COMPLY WITH ALL APPLICABLE ACCESSIBILITY STANDARDS. <br />ACCESSIBLE UNISEX RESTROOM <br />102 <br />T-0" <br />MATCH <br />WD <br />MATCH <br />A <br />HM <br />MATCH <br />02/A00.30 <br />01/A00.30 <br />--- <br />--- <br />8 <br />--- <br />HARDWARE FINISH TO MATCH EXISTING <br />F. <br />G. <br />CONTRACTOR SHALL REVIEW KEYING WITH OWNER PRIOR TO FITTING CYLINDERS. <br />AT EXISTING DOORS TO REMAIN OR TO BE RELOCATED, PATCH/FILL DIVOTS, HOLES, CRACKS, SCRATCHES, ETC. PRIOR TO <br />EXISTING <br />EXISTING <br />EXISTING <br />PRIMING/PAINTING/REFINISHING. CONTRACTOR TO IDENTIFY DOORS THAT CANNOT BE REPAIRED OR ARE NOT COMPATIBLE WITH NEW HARDWARE. <br />H. <br />CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL FIELD DIMENSIONS AFFECTING THE WORK. <br />I. <br />PAINTED DOORS SHALL BE PAINTED ON ALL 6 SURFACES. <br />J. <br />ALL INALL OF DOORS/WALLS/OPENINGS SHALL MATCH AND BE FLUSH WITH EXISTING ADJACENT PARTITION CONSTRUCTION. <br />K. <br />WHERE PARTITIONS ARE ATTACHED TO CURTAIN WALL, CENTER PARTITIONS ON WINDOW MULLIONS, PERPENDICULAR TO PERIMETER WALL, U.N.O. <br />L. <br />PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS SHALL ACCOMMODATE FULL CONCEALMENT OF RECESSED CABINETS OR PARTIAL <br />CONCEALMENT OF SEMI —RECESSED CABINETS AS SPECIFIED BY THE MANUFACTURER. <br />M. <br />WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION. <br />N. <br />ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH U.N.O. — REFER TO <br />ELEVATIONS AND THE FINISH SCHEDULE FOR MATERIALS THAT REQUIRE A LEVEL 5 FINISH. <br />0. <br />REFER TO THE PARTITION TYPES FOR PARTITION THICKNESS. <br />P. <br />CONSTRUCTION OF FIRE —RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, <br />SHALL BE IN ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED. <br />Q. <br />ACOUSTICAL (SOUND —ISOLATION) PARTITIONS SHALL BE SEALED FOR FULL HEIGHT TO PREVENT PASSAGE OF AIRBORNE SOUND. TAPE AND FINISH <br />ALL GYPSUM WALLBOARD JOINTS AND FASTENERS (INCLUDING ABOVE SUSPENDED CEILING). CAULK AT PERIMETER AND SEAL AT ALL PENETRATIONS. <br />R. <br />WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, SECURE THE TOP TRACK TO THE EXPOSED TEE GRID. PROVIDE A <br />COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE TEE GRID. PROVIDE TAPABLE METAL J—BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO <br />JOINTS VARYING MORE THAN 1/8" OVER W-0" AND NO JOINTS GREATER THAN 3/16", UNOCAULK PERIMETER AT TOP OF GWB. <br />S. <br />PROVIDE DOUBLE STUDS AT DOOR JAMBS. INSTALL ADDITIONAL STUDS IN EXISTING PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO PROVIDE <br />DOUBLE STUDS AT JAMBS. <br />T. <br />GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING ROUGHING (E.G.BATHROOMS, PANTRY, JANITORS CLOSET, WET COLUMNS) <br />SHALL BE WATER—RESISTANT. <br />DOOR TYPES <br />02 <br />2" HOLLOW METAL <br />FRAME <br />/ SOLID CORE WOOD <br />DOOR <br />\ c� <br />\ of <br />\ � _ V3O <br />fV <br />\ M <br />DOOR TYPE A <br />SINGLE PAINT GRADE <br />HARDWARE SCHEDULES <br />Hardware Group No. 8 <br />Provide door with the following: <br />Quantity <br />Description <br />Model Number <br />Finish <br />Mfr <br />3 EA <br />HINGE <br />BB1279 4.5X4.5 <br />EXST <br />HAG <br />1 EA <br />PRIVACY SET <br />ND40S SPA <br />EXST <br />SCH <br />1 EA <br />WALL STOP <br />WS407CCV <br />EXST <br />IVE <br />1 EA <br />KICKPLATE <br />8400 10" X 2" LDW <br />EXST <br />IVE <br />1 SET <br />SEALS <br />188S <br />CLR <br />ZER <br />PARTITION TYPES <br />* GC TO VERIFY EXISTING <br />CONSTRUCTION AND MATCH HEIGHT OF <br />ADJACENT EXISTING RESTROOM WALLS <br />UNDERSIDE OF SLAB OR STRUCTURE <br />ABOVE <br />`--SPECIFIED CEILING, REFER TO <br />REFLECTED CEILING PLAN <br />WALL CONSTRUCTION SHALL INCLUDE_: <br />-5/8" GYP. BD. EA. SIDE. PROVIDE <br />MOISTURE RESISTANT GWB AT WET WALLS <br />-GYP. BD. TO EXTEND TO CEILING <br />-3-5/8" W. METAL STUDS SPACED AT A <br />MAXIMUM 24" O.C. SEE STUD CHART (A) <br />FOR CORRESPONDING GAUGE. -CONTINUOUS <br />SEALANT ON BOTH SIDES OF FLOOR <br />RUNNERS <br />-APPROPRIATE METAL TRIM AND CASING <br />BEADS AS REQUIRED <br />SPECIFIED BASE <br />CONTINUOUS ACOUSTICAL SEALANT <br />IrZ,,—: FLOOR I SLABED OOR FINISH <br />II I <br />PARTITION TYPE A <br />POWER DRIVEN FASTENERS 02'-0" O.C. <br />ALTERNATING SIDES AND WITHIN 3" OF <br />EACH END OF TRACK <br />SCHEDULED PARTITION <br />METAL STUD <br />CAULK HOLLOW METAL FRAME <br />HOLLOW METAL FRAME <br />METAL CLIP <br />SCHEDULED DOOR <br />11%6" VARIES 1?/6' <br />SHEET NOTES <br />PaditionTypes indicated in the construction documents shall comply with the following criteria for non—structural <br />cold —formed steel framing wall systems: <br />A. All non—structural stud shall comply with the minimum gaugeand mils thickness listed below (Substitutions: <br />Contractor shall submit substitutions for architect's approval prior to ordering material or proceeding with <br />construction of partitions): <br />Gauge: mils: <br />25 go 18 mil (minimum stud gauge) <br />22 go 27 mil <br />20 go 33 mil <br />18 go 43 mil <br />16 go 54 mil <br />B. Limiting heights shall be referenced from 2014IBC approved SSMAcharts for nonstructural cold —formed steel <br />framing wall systems for each of the following assemblies as included in the project scope: <br />Interior Wall Heights — Composite: composite limiting heights are based on a single layer of 5/8" type—X <br />gypsum board installed to both sides of the wall over full height using minimum No. 6 type S—drywall screws <br />spaced a maximum of 12" O.C. for studs at 24" O.C. (maximum spacing), and 16" O.C. for studs at 16" and <br />12" spacing where required. Increase metal stud gouge and/or decrease metal stud O.C. spacing so as not <br />to exceed 1/240 design criteria with 5 PSF lateral load. Refer to SSMA "table notes" for complete property <br />criteria. <br />Interior Wall Limiting Heights Non —composite — Fully Braced; limiting heights are based on steel properties <br />only (non —composite) without the contribution of sheathing to strength and stiffness of the assembly. <br />Properly fastened sheathing is still required for members to be considered fully braced. Refer to SSMA "table <br />notes" for complete property criteria. <br />Interior Wall Limiting Heights — Braced at 48" O.C.: limiting heights are based on studs braced at maximum <br />spacing of 48" O.C. Bracing can be placed at a greater distance if deflection controls (d), maximum brace <br />spacing is listed under "Lbr" column of the chart. Refer to SSMA "Table Notes" for complete property <br />criteria. <br />C. Brace metal studs to structure as required by applicable building codes and the A.H.J. <br />D. Contractor shall provide deflection track for top runners of metal stud partitions that extend to underside of <br />structural deck where deflections of the structural roofing system exceed 1/2" where partitions are located. <br />1 <br />11/o Y 11- 1 <br />SCHEDULED PARTITION <br />CAULK JOINT, TYPICAL <br />HOLLOW METAL FRAME <br />METAL ANCHOR <br />SCHEDULED DOOR <br />HOLLOW METAL FRAME <br />CAULK JOINT, TYPICAL <br />SCHEDULED PARTITION <br />Bank of America �%j <br />ADA- ZEPHYRHILLS <br />5632 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />SERIAL NUM./MANH. ID: FL2-019 <br />NELSON <br />Nelco Architecture, Inc. <br />a licensed affiliate <br />Florida Certificate of Authorization Number: AA26000525 <br />Architect: Client Representative: <br />Firm Name: NELSON Firm Name: JLL <br />Attn: Mark Schroeder Attn: Lisa Drees <br />T: 404.881.1811 T: 813.624.4512 <br />e-mail: mschroeder@nelsononline.com e-mail: lisa.drees@am.jll.com <br />Engineering: <br />Infinity Engineering Group, LLC <br />Attn: Nisit Sapparkhao <br />T: 813.830.2330 <br />e-mail: nisit@iegroup.net <br />General Contractor: <br />Firm Name: Spartan Contracting Corporation <br />Attn: Scott Kramer <br />T: 813.481.5778 <br />e-mail: skramer@spartancc.com <br />QIssue <br />Issue <br />Date & Description <br />By <br />Check <br />1 <br />03/23/18 Issue For Review <br />AJB <br />AFO <br />2 <br />04/23/18 Issue For CD Review <br />KS <br />AFO/MS <br />3 <br />04/27/18 Issue For Permit <br />KS <br />MS <br />Seal/Signature <br />Architect of Record, Mark Schroeder <br />Lic. # : AR0016438 <br />p d <br />Project Namey <br />Bank of America <br />Zephyrhills <br />AWA upgraae <br />INELSON Project Number <br />18.00358.00 <br />IDescription <br />DOOR AND HARDWARE SCHEDULE, PARTITION <br />TYPES AND DETAILS <br />IScale & Sheet Number <br />A0030 <br />SECTION AT HOLLOW METAL FRAME HEAD 42 SECTION AT HOLLOW METAL FRAME JAMB 1 <br />SCALE: 1-1 /2"=1'-0" SCALE: 1-1 /2"=1'-0" <br />