Laserfiche WebLink
TENANT FINISH <br />ZEPHYRHILLS, FL <br />A. ALL WORK SHALL CONFORM TO THE 6th EDITION OF THE FLORIDA BUILDING CODE (2017), AND ALL OTHER <br />APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF ZEPHYRHILLS, FLORIDA. <br />B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. <br />C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. A201 LATEST EDITION) ARE A PART <br />OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECTS OFFICE. <br />D. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY <br />DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO <br />STARTING WORK. <br />E. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO INSTALLATION. <br />F. SUBMIT, PAY FEES AND OBTAIN ALL PERMITS ASSOCIATED WITH THE PROJECT EXCEPT GENERAL BUILDING <br />PERMIT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, OR <br />OTHER RELATED FIRE PERMITS. ZEPHYR, LLC WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY <br />PERMITS. PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. <br />G. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY -PERMITTED DRAWING SET AT TIME OF <br />CONSTRUCTION. <br />H. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS <br />ARE NOT CLEAR. <br />I. GC SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS <br />OTHERWISE NOTED. SEE SCOPE OF WORK FOR EXCEPTIONS. <br />J. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED <br />WITH ALL TRADES PRIOR TO INSTALLATION. <br />K. ALL MATERIALS STAGED TO BE USED FOR CONSTRUCTION SHALL BE PROTECTED FROM EXCESSIVE MOISTURE. <br />IF THEY ARE EXPOSED TO MOISTURE THEY SHOULD BE ADEQUATELY DRIED BEFORE ENCAPSULATED INTO THE <br />BUILDING. <br />L. <br />GENERAL CONTRACTOR SHALL PROVIDE PEST INSPECTION AND EXTERMINATION SERVICES PRIOR TO START <br />OF WORK. PROVIDE INVOICES AND A REPORT FROM THE EXTERMINATION PROFESSIONAL TO THE OWNER. <br />M. GENERAL CONTRACTOR SHALL PROVIDE WEEKLY CONSTRUCTION PROGRESS REPORTS TO THE OWNER, <br />TENANT, AND ARCHITECT. <br />PROJECT GENERAL NOTES <br />NAME ROOM NAME <br />1 <br />SHEET NUMBER <br />4OAX.X2 <br />_� ELEVATION NUMBER <br />3 <br />CEILING HEIGHT <br />BLDG. SECTION LETTER <br />X <br />AX.X <br />BLDG. SECTION SHEET <br />DETAIL NUMBER <br />X <br />DIRECTION OF DETAIL <br />DETAIL SHEET <br />A REVISION NUMBER <br />0'-0" <br />BLDG. HEIGHT <br />ELEV REFERENCE POINT <br />X ELEV. LETTER <br />• ELEV. SHEET <br />XO DOOR NUMBER <br />O WINDOW NUMBER / DECOR ITEM NUMBER <br />EXTERIOR WALL FINISH NUMBER <br />OX KEY NOTE NUMBER <br />X-000 EQUIPMENT NUMBER <br />INTERIOR FINISH <br />OINTERIOR WALL TYPE <br />INTERIOR ELEVATION DESIGNATION <br />IDSHEAR WALL TYPE (STRUCTURAL) <br />XXX 000 EQUIPMENT / FIXTURE NUMBER (M.E.P.) <br />INDICATES SUSTAINABLE DESIGN <br />GREEN <br />REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS <br />GENERAL DRAWING SYMBOLS <br />nonnnern %einnii <br />LEGAL JURISDICTION: CITY OF ZEPHYRHILLS, FLORIDA <br />BUILDING CODE: 2017 FLORIDA BUILDING CODE FAMILY (6TH EDITION) <br />BUILDING FOOTPRINT: 4873 S.F. <br />FIRE AREA: 4916 S.F. (INCL. WALK-IN) <br />OCCUPANCY: A2 <br />TYPE CONSTRUCTION: TYPE II B-UNSPRINKLERED <br />EXISTING BUILDING AREA AND OCCUPANT LOAD <br />TYPE AREA FACTOR OCCUPANTS <br />ASSEMBLY -STANDING AREA 200 S.F. 1:5 GROSS 40 <br />ASSEMBLY -SEATING 1960 S.F. 1:15 GROSS 131 <br />KITCHEN -COMMERCIAL 2325 S.F. 1:200 GROSS 12 <br />TOTAL 183 OCCUPANTS <br />PLUMBING FIXTURE CALCULATION <br />WATER CLOSETS LAVATORIES DRINKING FOUNTAIN SERVICE SINK <br />REQ./ ACTUAL REQ / ACTUAL REQ. / ACTUAL REQ. / ACTUAL <br />MEN 2/ 2 112 1/ 0 (WATER AVAIL.) 1/ 1 <br />WOMEN 2/2 1/2 <br />UNISEX (EMPLOYEE) 1 PROVIDED 1 PROVIDED <br />PROJECT SUMMARY <br />REFER TO STRUCTURAL <br />DESIGN CRITERIA <br />REFER TO CIVIL DRAWINGS. <br />LEGAL DESCRIPTION <br />OWNER <br />ARCHITECT <br />ZEPHYR, LLC <br />L.B. MANSKE ARCHITECTURE & DESIGN, INC. <br />7162 READING ROAD, STE 730 <br />LEE B. MANSKE, AIA, NCARB <br />CINCINATTI, OH 45237 <br />2422 N. RUTGERS COURT <br />WICHITA, KS 67205 <br />316.749.5873 <br />STRUCTURAL ENGINEER <br />JOHN GUTHERMAN JR., P.E. <br />264 BUTTERCUP CIRCLE <br />ALTAMONTE SPRINGS, FL 30714 <br />407.701.0875 <br />CIVIL ENGINEER <br />MECHANICAL ENGINEER <br />CORNELISON ENGINEERING & DESIGN, INC. <br />JUSTIN HARDY, PE <br />38039 OLD 5TH AVENUE 33542 <br />5014 KINGSBRIDGE PASS <br />813.788.7835 <br />POWDER SPRINGS, GA <br />678.234.8156 <br />ELECTRICAL ENGINEER <br />GUIDO ALVAREZ, PE <br />5014 KINGSBRIDGE PASS <br />POWDER SPRINGS, GA <br />678-234-8156 <br />PROJECT DIRECTORY <br />SEWER <br />TELEPHONE <br />(Company) <br />(Company) <br />(Address) <br />(Address) <br />(City, State, Zip) <br />(City, State, Zip) <br />Contact: <br />Contact: <br />Phone: <br />Phone: <br />WATER <br />ROADS <br />(Company) <br />(Company) <br />(Address) <br />(Address) <br />(City, State, Zip) <br />(City, State, Zip) <br />Contact: <br />Contact: <br />Phone: <br />Phone: <br />GAS <br />OTHER <br />(Company) <br />(Company) <br />(Address) <br />(Address) <br />(City, State, Zip) <br />(City, State, Zip) <br />Contact: <br />Contact: <br />Phone: <br />Phone: <br />ELECTRIC <br />OTHER <br />(Company) <br />(Company) <br />(Address) <br />(Address) <br />(City, State, Zip) <br />(City, State, Zip) <br />Contact: <br />Contact: <br />Phone: <br />Phone: <br />UTILITY CONTACTS <br />TITLE SITE <br />T1.0 TITLE SHEET <br />CIVIL <br />SITE EXISTING (CURRENTLY UNDER CONSTRUCTION) <br />STRUCTURAL <br />SHELL EXISTING (CURRENTLY UNDER CONSTRUCTION) <br />ARCHITECTURAL <br />A1.0 FLOOR PLAN <br />A1.1 DOOR & WINDOW ELEVATION & SCHEDULE <br />A3.0 ROOF PLAN <br />A4.0 EXTERIOR ELEVATIONS <br />A4.1 EXTERIOR ELEVATIONS <br />A5.0 BUILDING SECTIONS <br />A5.1 WALL SECTIONS <br />A5.2 WALL SECTIONS <br />A6.1 CONSTRUCTION DETAILS <br />A7.1 REFLECTED CEILING PLAN <br />ACCESSIBILITY <br />ADA1.0 ACCESSIBILITY REQUIREMENTS <br />MECHANICAL <br />M0.1 MECHANICAL SCHEDULES AND DETAILS <br />M0.2 MECHANICAL SPECIFICATIONS <br />M1.0 MECHANICAL PLANS <br />M1.1 MECHANICAL HOOD PLANS <br />PLUMBING <br />P0.1 PLUMBING SCHEDULES AND DETAILS <br />P1.0 PLUMBING SANITARY PLAN <br />P2.0 PLUMBING DOMESTIC WATER PLANS <br />ELECTRICAL <br />E0.0 ELECTRICAL GENERAL NOTES AND LEGEND <br />E1.0 ELECTRICAL LIGHTING PLAN <br />E2.0 ELECTRICAL POWER PLAN <br />E3.0 MECHANICAL POWER PLAN <br />E4.0 ELECTRICAL DETAILS <br />SHEET INDEX <br />• <br />V <br />M <br />C) <br />Z <br />� <br />ALb ~ <br />� U7 <br />00 <br />W <br />U <br />Z <br />a <br />18014 <br />0 <br />0 <br />ti <br />rn <br />w <br />W <br />z <br />w <br />U <br />J <br />ED <br />60' <br />z <br />Q <br />Q <br />w <br />Y <br />z <br />m <br />w <br />w <br />J <br />CONTRACT DATE: 08.13.2017 <br />BUILDING TYPE: ONE-OFF <br />PLAN VERSION: <br />SITE NUMBER: <br />STORE NUMBER: <br />SUNRISE EATERY <br />5915 GALL BLVD. <br />ZEPHYRHILLS, FL <br />TITLE SHEET <br />T1.0 <br />PLOT DATE: May 10, 2018 - 10:30pm <br />