Laserfiche WebLink
J <br />ELECTRICAL LEGEND <br />F21 O <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />q� <br />tT' <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />[A Lid <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />SPO <br />SURGE PROTECTION DUPLEX RECEPTACLE, 20A, 125V <br />PROVIDE WITH EMERGENCY BALLAST <br />HUBBELL CAT.NO HBL5360SA, NEMA 5-20R <br />® <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />DUPLEX RECEPTACLE <br />ABOVE COUNTER OR AS NOTED, NEMA 5-20R <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />QUAD RECEPTACLE <br />PROVIDE WITH EMERGENCY BALLAST <br />18" AFF OR AS NOTED, NEMA 5-20R <br />Q <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />IG <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />O <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />SPECIAL PURPOSE RECEPTACLE <br />PROVIDE WITH EMERGENCY BALLAST <br />18" AFF OR AS NOTED, SEE SCHEDULE <br />F--Q-� <br />FLUORESCENT STRIP FIXTURE <br />FQ/ JQ <br />WALL / CEILING MOUNTED JUNCTION BOX <br />^ , <br />�, jy <br />WALL MOUNTED FIXTURE, TYPE AS NOTED <br />60/3/1 <br />UNFUSED DISCONNECT SWITCH <br />RATING/POLES/NEMA RATING <br />60/3/3R/40 <br />FUSED DISCONNECT SWITCH <br />PENDANT FIXTURE, TYPE AS NOTED <br />RATING/POLES/NEMA RATING/FUSE SIZE <br />PENDANT FIXTURE, TYPE AS NOTED <br />^- <br />MOTOR <br />PROVIDE WITH EMERGENCY BALLAST <br />.��.j. <br />TRACK LIGHT FIXTURE, TYPE AS NOTED <br />�II <br />GROUND <br />EMERGENCY LIGHT <br />0 <br />TELEPHONE OUTLET, PROVIDE 4" BOX <br />SINGLE GANG PLASTER RING, 1" C STUBBED 6" ABOVE CEILING <br />TELEPHONE OUTLET, PROVIDE 4" BOX <br />EXIT/EMERGENCY LIGHT COMBINATION <br />-T <br />HALF SHADED- INDICATES SINGLE JACK, FULL SHADED INDICATES <br />TWO JACKS. NETWORK WIRING SYSTEM: <br />® <br />CEILING MOUNTED EXIT SIGN <br />CAT 5E 110, RJ45 JACK WIRED TO SPEC 568B MODULAR JACK <br />PROVIDE ONE JACK AND ONE POSITION IVORY FACEPLATE AT <br />WALL MOUNTED EXIT SIGN <br />SINGLE JACK LOCATIONS AND TWO AT DOUBLE LOCATIONS. <br />CONTACT PHIL BENTON, 678-966-3335 FOR INFO. <br />DOUBLE BOX, AS DESCRIBED ABOVE EXCEPT CONNECT 2 LINES <br />SINGLE POLE SWITCH, 44" AFF <br />V <br />DIRECTLY FROM PUNCH BLOCK (D-MARK) TO DOUBLE BOX IN <br />MANAGER' OFFICE <br />TWO SINGLE POLE SWITCHES GANGED TOGETHER <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF <br />THREE SINGLE POLE SWITCHES GANGED TOGETHER <br />SINGLE BOX- MANAGER'S/FAX, DEDICATED ANALOG TELEPHONE <br />44" AFF <br />® <br />LINE WITH RINGMASTER, CAT 5E, RJ11 - NOT TO BE ROUTED <br />THROUGH TELEPHONE SYSTEM. TERMINATE AT PUNCH BLOCK <br />THREE WAY SWITCH, 44" AFF <br />(D-MARK) <br />TWO THREE WAY SWITCHES GANGED TOGETHER <br />SINGLE BOX- DSULSR DEDICATED ANALOG TELEPHONE LINE <br />cl <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF <br />0 <br />WITH RINGMASTER, CAT 5E, RA 1 - NOT TO BE ROUTED THRU <br />TELEPHONE SYSTEM. TERMINATE AT PUNCH BLOCK (D-MARK) <br />FOUR WAY SWITCH, 44" AFF <br />q <br />WALL BOX DIMMER 1000W UNLESS NOTED DIFFERENTLY <br />SPEAKER STROBE <br />44" AFF <br />$yip <br />WEATHER PROOF SWITCH, 44" AFF <br />HORN <br />$M <br />MOTOR RATED SWITCH, 44" AFF OR AS NOTED <br />® <br />PULL STATION <br />$OS <br />COMBINATION SWITCH AND OCCUPANCY SENSOR, 44" AFF <br />Q <br />FIRE ALARM STROBE, MIN 75 CANDELA <br />CEILING / WALL MOUNT <br />$T <br />DIGITAL TIMER SWITCH, 44" AFF <br />DUCT MOUNTED SMOKE DETECTOR <br />®x <br />CEILING MOUNTED OCCUPANCY SENSOR <br />OS <br />SMOKE DETECTOR <br />�X <br />WALL MOUNTED OCCUPANCY SENSOR, 44" AFF <br />OH <br />HEAT DETECTOR <br />T� <br />TIME CLOCK <br />TS <br />TAMPER SWITCH <br />LJ� <br />SINGLE DOME, CEILING AND WALL MOUNTED SECURITY <br />FS <br />FLOW SWITCH <br />CAMERAS. FURNISHED AND INSTALLED BY OTHERS. <br />® <br />PHOTO CELL <br />RACEWAY CONCEALED IN WALL OR ABOVE CEILING <br />8" CONE SPEAKER IN CEILING <br />_� <br />RACEWAY EXPOSED <br />EC TO PROVIDE BLACK SPEAKER <br />(� <br />8" CONE SPEAKER IN WALL <br />RACEWAY CONCEALED IN FLOOR SLAB, BELOW SLAB OR GRADE <br />Y <br />EC TO PROVIDE BLACK SPEAKER <br />BELOW SLAB OR GRADE, OR UNDER RAISED ACCESS FLOOR <br />VOLUME CONTROL <br />DENOTES CONDUIT TURNING UP IN PLAN VIEW <br />PLYWOOD EQUIPMENT BACKBOARD <br />3 <br />DENOTES CONDUIT TURNING DOWN IN PLAN VIEW <br />4'X8' UNLESS NOTED OTHERWISE <br />CCTV <br />CLOSED CIRCUIT TELEVISION CAMERA <br />STUB UP <br />COAXIAL CABLE OUTLET <br />XXXX <br />SHORT CIRCUIT AVAILABLE CURRENT <br />(NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS AND ARE USED AS APPLICABLE TO THIS PROJECT) <br />ABBREVIATIONS <br />ELECTRICAL SPECIFICATIONS <br />A. DEFINITIONS: <br />1. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR OPERATION. <br />2. "INSTALL": RECEIVE, MOUNT, AND CONNECT, COMPLETE AND READY FOR OPERATION. <br />3. "FURNISH": SUPPLY, DELIVER TO JOB SITE, PROTECT AND STORE. <br />B. WORK INCLUDED: PROVIDE ALL LABOR, TOOLS, MATERIAL, EXCAVATION, BACKFILL, CUTTING, PATCHING, TESTING, <br />ADJUSTING, AND TRADE COORDINATION REQUIRED FOR A COMPLETE AND FULLY OPERATIONAL INSTALLATION, AS <br />DESCRIBED ON THE DRAWINGS OR IN THE SPECIFICATIONS. <br />C. CODES, RULES, AND REGULATIONS: COMPLY WITH ALL CODES ENFORCED BY THE LOCAL INSPECTION AUTHORITY, <br />THE EDITION OF THE NATIONAL ELECTRICAL CODE BEING ENFORCED FOR THIS PROJECT BY THE LOCAL INSPECTION <br />AUTHORITY, ALL APPLICABLE LAWS AND ORDINANCE, NFPA FIRE CODES, STANDARD BUILDING CODE. GIVE ALL <br />NECESSARY NOTICES, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL INSPECTION AND OTHER FEES REQUIRED BY <br />AUTHORITIES HAVING JURISDICTION OVER THE WORK. <br />D. MATERIALS: ALL MATERIAL SHALL BE NEW, AND SHALL COMPLY WITH THE INDICATED STANDARDS. ALL MATERIAL <br />SHALL BE UL LABELED OR UL LISTED. ALL MATERIAL SHALL BE OF A SUITABLE TYPE AND RATING FOR THE INTENDED <br />USE, AND SHALL BE INSTALLED IN CONFORMANCE WITH THE INSTRUCTIONS AND RECOMMENDATIONS OF THE <br />MANUFACTURER. <br />E. DRAWINGS <br />1. THE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL OF THE REQUIRED DETAILS OF THE <br />WORK. ALL MATERIALS CUSTOMARILY CONSIDERED TO BE A PART OF THE ELECTRICAL WORK AND REQUIRED <br />FOR A COMPLETE AND OPERATIONAL INSTALLATION SHALL BE PROVIDED WITHOUT ADDITIONAL COST TO THE <br />OWNER. <br />2. THE CONTRACTOR SHALL REFER ALSO TO THE ARCHITECTURAL DRAWINGS AND TO THE DRAWINGS OF ALL <br />OTHER TRADES TO COORDINATE THE ELECTRICAL INSTALLATION. WHERE ELECTRICAL EQUIPMENT IS SHOWN <br />ON ARCHITECTURAL DRAWINGS OR DETAILS, THE EQUIPMENT SHALL BE INSTALLED AS SHOWN ON THE <br />ARCHITECTURAL DRAWINGS. <br />3. EQUIPMENT OF OTHER TRADES IS SHOWN SCHEMATICALLY ON THE ELECTRICAL DRAWINGS. THE <br />CONTRACTOR SHALL EXAMINE THE DRAWINGS OF THE TRADE PROVIDING THE EQUIPMENT BEFORE <br />ROUGHING IN THE CONNECTIONS FOR IT. THE CONTRACTOR SHALL CONNECT THE EQUIPMENT WHERE <br />ACTUALLY INSTALLED, INCLUDING WIRING THROUGH ANY LINE VOLTAGE CONTROLLERS, WITHOUT ANY <br />ADDITIONAL COST TO THE OWNER. <br />4. PRIOR TO ROUGHING IN CIRCUITS FOR EQUIPMENT FURNISHED BY OTHER TRADES, AND PRIOR TO RELEASING <br />FOR MANUFACTURE PANELBOARDS, STARTERS OR MOTOR CONTROL CENTERS FEEDING SUCH EQUIPMENT, <br />THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL PROVISIONS BEING PLANNED WITH THE TRADE <br />PROVIDING THE EQUIPMENT AND SUBMIT ANY CONFLICTS IN WRITING TO THE ARCHITECT. <br />5. THE ARCHITECT MAY DIRECT THE RELOCATION OF ANY ELECTRICAL OUTLET, FIXTURE, OR OTHER EQUIPMENT <br />TO A LOCATION WITHIN 10 FEET OF THE LOCATION SHOWN ON THE DRAWINGS AT NO ADDITIONAL COST TO <br />THE OWNER PROVIDED SUCH RELOCATION IS DIRECTED PRIOR TO THE INSTALLATION OF THE OUTLET, <br />FIXTURE OR EQUIPMENT BEING RELOCATED. <br />D. SUBMITTAL DOCUMENTS: PRODUCT DATA AND SHOP DRAWINGS SHALL BE SUBMITTED IN SIX COPIES TO THE <br />ARCHITECT FOR REVIEW PRIOR TO THE RELEASE OF THE MATERIAL FOR MANUFACTURE. REVIEW OF SUBMITTALS <br />BY THE ARCHITECT WILL BE ONLY FOR GENERAL CONFORMANCE WITH THE DRAWINGS AND SPECIFICATIONS. <br />REVIEW WILL BE MADE ONLY OF INFORMATION CLEARLY AND SPECIFICALLY INDICATED IN THE SUBMITTAL, AND <br />DOES NOT IMPLY THE ACCEPTABILITY OF DETAILS WHICH ARE NOT SO DESCRIBED IN THE SUBMITTAL. REVIEW OF <br />THE SUBMITTAL DOCUMENTS BY THE ARCHITECT DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO <br />COMPLY WITH ALL REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. SUBMITTAL IS REQUIRED FOR <br />PANELBOARDS AND LOADCENTERS, LIGHT FIXTURES, WIRING DEVICES, FIRE ALARM DEVICES, AND SURFACE <br />ALUMINUM RACEWAY. <br />G. AS -BUILT DRAWINGS: AS -BUILT DRAWINGS SHALL BE MAINTAINED AT THE JOBSITE, AND SHALL BE AVAILABLE FOR <br />REVIEW DURING CONSTRUCTION. AS -BUILT DRAWINGS SHALL BE KEPT CURRENT DURING THE COURSE OF <br />CONSTRUCTION OF THE WORK. SUBMIT AS -BUILT DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF THE <br />PROJECT. <br />H. TESTING: TEST ALL PARTS OF THE WORK TO VERIFY COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. <br />VERIFY TIGHTNESS OF ALL MECHANICAL AND ELECTRICAL CONNECTIONS. VERIFY INTEGRITY OF ALL WIRING <br />SYSTEMS TO ASSURE CONTINUITY, ABSENCE OF UNINTENTIONAL GROUNDS, AND INTEGRITY OF REQUIRED <br />GROUNDS. <br />I. CHANGE REQUEST (CHANGE ORDER) APPROVAL: CHANGE REQUESTS WILL NOT BE CONSIDERED UNLESS THE <br />CONTRACTOR'S DETAILED LABOR AND MATERIAL ESTIMATE DESCRIBING THE CHANGE IS SUBMITTED TO THE <br />ARCHITECT ALONG WITH THE CHANGE REQUEST, WITH MATERIAL PRICES AND LABOR UNITS ASSIGNED TO EACH <br />LINE ITEM OF THE ESTIMATE. MATERIAL PRICES SHALL BE THE ACTUAL PRICE PAID BY THE CONTRACTOR FOR <br />MATERIAL PURCHASED OR THE ACTUAL PRICE QUOTED TO THE CONTRACTOR BY THE MATERIAL VENDOR <br />PROPOSED BY THE CONTRACTOR. <br />J. COORDINATION WITH THE WORK OF OTHERS: COORDINATE WITH EACH TRADE FURNISHING EQUIPMENT REQUIRING <br />ELECTRICAL SERVICE TO INSURE THAT THE CHARACTERISTICS SHOWN ON THE DRAWINGS FOR THE CIRCUIT <br />SERVING THE EQUIPMENT ARE COMPATIBLE WITH THE REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED. <br />CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND ASSOCIATED BRANCH CIRCUITS SHOWN ON THE <br />DRAWINGS TO FEED HVAC EQUIPMENT, KITCHEN EQUIPMENT, ELEVATOR MOTORS, AND OTHER EQUIPMENT HAVE <br />BEEN SELECTED BASED UPON THE CHARACTERISTICS OF EQUIPMENT BY ONE MANUFACTURER AND MAY NOT BE <br />CORRECT FOR THE EQUIPMENT BEING PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE <br />OPERATING CHARACTERISTICS OF THE EQUIPMENT ACTUALLY BEING PROVIDED AND SHALL PROVIDE AT NO <br />ADDITIONAL COST TO THE OWNER CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND BRANCH CIRCUITS AS <br />REQUIRED BY THAT EQUIPMENT. <br />K. EXISTING WORK: THE EXISTING ELECTRICAL INSTALLATION SHALL REMAIN AS -IS AND IN OPERATION EXCEPT WHERE <br />OTHERWISE REQUIRED. GIVE WRITTEN NOTICE OF ANY UNFORESEEN EXISTING CONDITIONS WHICH MAY AFFECT <br />THE WORK. WORK INVOLVING EXISTING SYSTEMS OR EXISTING SPACES SHALL BE ACCOMPLISHED WITH MINIMUM <br />INCONVENIENCE TO THE OWNER, AND SHALL BE DONE IN A MANNER AND TIME APPROVED BY THE OWNER. ANY <br />INTERRUPTIONS SHALL BE DURING TIMES DESIGNATED BY THE OWNER. <br />L. DEMOLITION: IN THE AREA SHOWN ON THE ARCHITECTURAL DRAWINGS TO BE DEMOLISHED REMOVE ALL EXISTING <br />A, AMPS <br />AMPERES <br />FLA <br />FULL LOAD AMPERES <br />NO <br />NORMALLY OPEN, <br />CONDUITS, CONDUCTORS, BOXES, FIXTURES, SERVICE ENTRANCE CONDUCTORS, DISTRIBUTION EQUIPMENT, AND <br />A/C <br />AIR CONDITIONER <br />GND <br />GROUND <br />NUMBER <br />ALL OTHER ELECTRICAL EQUIPMENT NOT SHOWN TO REMAIN. UNLESS OTHERWISE INDICATED, MATERIAL BEING <br />AC <br />ALTERNATING CURRENT <br />GALV <br />GALVANIZED <br />NTS <br />NOT TO SCALE <br />REMOVED INCLUDING WIRE, CONDUIT, AND HANGING MATERIALS BEING REMOVED SHALL BECOME THE PROPERTY <br />AF <br />AMPERE FRAME <br />PNL <br />PANELBOARD <br />OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES. EQUIPMENT NOTED TO REMAIN THE <br />AFF <br />ABOVE FINISHED FLOOR <br />GRS <br />GALVANIZED RIGID STEEL <br />PVC <br />POLYVINYL CHLORIDE <br />PROPERTY OF THE OWNER SHALL BE STORED ON SITE AS DIRECTED BY THE ARCHITECT. COORDINATE WITH OTHER <br />AFG <br />ABOVE FINISHED GRADE <br />GFCI <br />GROUND FAULT <br />RGS <br />RIGID GALVANIZED <br />TRADES AND DISCONNECT MOTORS, HEATERS, OR OTHER EQUIPMENT AS REQUIRED FOR THE DEMOLITION OF <br />AIC <br />AMPERE <br />CIRCUIT INTERRUPTER <br />STEEL CONDUIT <br />OTHER TRADES WORK. CUT OFF ALL IN FLOOR CONDUITS, GRIND SMOOTH WITH FLOOR AND PREPARE FOR <br />GFI <br />GROUND FAULT INTERRUPTER <br />RMC <br />RIGID METALLIC <br />PATCHING BY OTHERS. REMOVE CONDUCTORS AND DEVICES FROM WALL AND CEILING OUTLETS AND PREPARE <br />INTERRUPTING CURRENT <br />HD <br />HEAT DETECTOR <br />CONDUIT (GALVANIZED) <br />OUTLET FOR PATCHING BY OTHERS. CONTRACTOR SHALL DENOTE ALL DEMOLISHED CIRCUITS ON EXISTING PANEL <br />AL <br />ALUMINUM <br />HP <br />HORSEPOWER <br />RMS <br />ROOT -MEAN -SQUARE <br />DIRECTORIES AND NOTE ALL SPARE BREAKERS. <br />ANSI <br />AMERICAN NATIONAL <br />STANDARDS INSTITUTE <br />IMC <br />INTERMEDIATE METAL CONDUIT <br />RNC <br />RIGID NON-METALLIC <br />ISC <br />INTERRUPTING SHORT CIRCUIT <br />CONDUIT <br />M. BASIC MATERIALS AND METHODS: <br />AWG <br />AMERICAN WIRE GAUGE <br />IG <br />ISOLATED GROUND <br />SCA <br />SHORT CIRCUIT <br />BC <br />BARE COPPER <br />INST <br />INSTANTANEOUS <br />AVAILABLE <br />1. ALL WORK SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS OF THE BUILDING, EXCEPT <br />BKBD <br />BACKBOARD <br />JB <br />JUNCTION BOX <br />SWBD <br />SWITCHBOARD <br />CEILING MOUNTED EQUIPMENT SUCH AS LIGHT FIXTURES, DETECTORS, REMOTE LAMPS, ETC. CEILING <br />C <br />CONDUIT <br />KAIC <br />KILO (THOUSAND) AMPERES <br />SWGR <br />SWIT <br />ITCHGEAR <br />MOUNTED EQUIPMENT SHALL BE SUPPORTED FROM CEILING STRUCTURAL MEMBERS, INDEPENDENT OF <br />CB <br />CIRCUIT BREAKER <br />INTERRUPTING CAPACITY <br />TBD <br />TO DETERMINED <br />CEILING TILES. SIZE AND SPACING OF SUPPORTS SHALL BE DETERMINED BY THE LOAD TO BE SUPPORTED SUCH <br />CKT <br />CIRCUIT <br />KCMIL <br />KILO (THOUSAND) <br />TCP <br />TEMPERATURE CONTROL <br />THAT THE WORKING LOAD OF SUPPORTS WILL NOT EXCEED A SAFETY FACTOR OF 4:1. PLASTIC ANCHORS <br />CU <br />COPPER <br />ARE NOT ACCEPTABLE. ELECTRICAL WORK SHALL NOT BE SUPPORTED FROM PIPING, DUCTS, OR WORK <br />DIST <br />DISTRIBUTION <br />CIRCULAR MILS <br />PANEL <br />OF OTHER TRADES. <br />KV <br />KILO (THOUSAND) VOLTS <br />TD <br />TIME DELAY <br />DN <br />DP <br />DOWN <br />DISTRIBUTION PANEL <br />KVA <br />KILO (THOUSAND) <br />TEL <br />TELEPHONE <br />2. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL <br />DWG <br />DRAWING <br />VOLT-AMPERES <br />TVSS <br />TRANSIENT VOLTAGE <br />CENTERS, STARTERS, DISCONNECTS, PRIMARY SELECTOR SWITCHES, AND TRANSFORMERS. INDICATE <br />EB <br />ENCASED BURIAL <br />KW <br />KILO (THOUSAND) WATTS <br />SURGE SUPPRESSION <br />EQUIPMENT NAME, CIRCUIT SOURCE AND NUMBER, CIRCUIT SIZE, AMPERE RATING, VOLTAGE AND PHASE. <br />EC <br />EMPTY CONDUIT <br />KWH <br />KILO (THOUSAND) WATT-HOURS <br />TYP <br />TYPICAL <br />NAMEPLATES SHALL BE BLACK BACKGROUND LAMACOID PLASTIC WITH 0.25" WHITE LETTERS. <br />LFMC <br />LIQUID -TIGHT FLEXIBLE <br />UG <br />UNDERGROUND <br />EEW <br />ENERGIZED ELECTRICAL WORK <br />METAL CONDUIT <br />EGC <br />EQUIPMENT GROUNDING <br />MCB <br />MAIN CIRCUIT BREAKER <br />UL <br />UNDERWRITER'S LABORATORIES <br />CONDUCTOR <br />MCM <br />THOUSAND CIRCULAR MILS <br />LION <br />UNLESS OTHERWISE <br />ELR <br />END -OF -LINE RESISTOR <br />MCCB <br />MOLDED CASE <br />UNDERGROUND PULLBOX <br />EWC <br />ELECTRIC WATER COOLER <br />MLO <br />MAIN LUGS ONLY <br />V <br />VOLTS <br /><E> <br />EXISTING <br />N <br />NEUTRAL <br />VA <br />VOLT-AMPERES <br /><ER> <br />EXISTING TO REMAIN <br />NEC <br />NATIONAL ELECTRICAL <br />VFD <br />VARIABLE <br /><EX> <br />EXISTING <br />CODE <br />FREQUENCY DRIVE <br />FA <br />FIRE ALARM <br />NESC <br />NATIONAL ELECTRICAL <br />WH <br />WATER HEATER <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />SAFETY CODE <br />WP <br />WEATHERPROOF <br />FACP <br />FIRE ALARM CONTROL PANEL <br />NIC <br />NOT IN CONTRACT <br />WT <br />WATERTIGHT <br />NL <br />NIGHT LIGHT <br />XFMR <br />TRANSFORMER <br />3. ALL PENETRATIONS OF FIRE RATED WALLS, SLABS, PARTITIONS, AND CEILINGS SHALL BE FIREPROOFED <br />WITH A U.L. LISTED SYSTEM THAT WILL MAINTAIN THE ORIGINAL FIRE RATING OF THE PENETRATED <br />STRUCTURE. ALL FIREPROOFING MATERIALS APPLIED AT ANY ONE PENETRATION SHALL BE THE PRODUCT OF <br />ONE MANUFACTURER AND SHALL BE APPLIED AS DESCRIBED BY THE UL FIREPROOFING SYSTEM BEING <br />CONSTRUCTED. FIREPROOFING OF SLEEVES, CABLE TRAYS, TROUGHS, AND NIPPLES TO BE USED FOR LOW <br />VOLTAGE CABLES SHALL BE INDEFINITELY NON -HARDENING AND REMOVABLE WITH COMMON HAND TOOLS. <br />4. BACKBOARDS SHALL BE 8 FT. HIGH BY LENGTH SHOWN ON THE DRAWINGS AND SHALL BE UL LABELED <br />FIRE TREATED PLYWOOD. <br />5. PROVIDE ALL POWER WIRING AND CONNECTIONS FOR ALL ELECTRICALLY OPERATED EQUIPMENT. POWER <br />WIRING INCLUDES WIRING THROUGH ANY LINE VOLTAGE CONTROL DEVICES, SUCH AS THERMOSTATS AND <br />MANUAL STARTERS. INSTALL ALL STARTERS AND CONTACTORS EXCEPT THOSE FURNISHED AS AN INTEGRAL <br />PART OF THE EQUIPMENT. <br />6. CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT NOT INSTALLED IN A <br />PLENUM SPACE SHALL BE MADE WITH A SHORT LENGTH OF LIQUIDTIGHT FLEXIBLE CONDUIT, MINIMUM 18", <br />INSTALLED IN A MANNER TO PERMIT MOVEMENT OF EQUIPMENT. <br />7. PERFORM ALL EXCAVATING, BACKFILLING, CUTTING AND REPAIRING REQUIRED FOR INSTALLATION OF <br />ELECTRICAL WORK. <br />8. CONTRACTOR SHALL X-RAY FLOOR SLABS, WALLS, OR CEILING CONCRETE PRIOR TO ALL CORE DRILLINGS. <br />N. CONDUIT: FEEDERS AND BRANCH CIRCUIT HOME RUNS SHALL BE CONSTRUCTED OF EMT WITH ALL STEEL <br />RAINTIGHT OR SET -SCREW FITTINGS. CONNECTORS SHALL BE INSULATED THROAT TYPE. PROVIDE METALLIC <br />BUSHINGS WITH PLASTIC INSERTS FOR 3" OR LARGER. CONDUITS FEEDING OR CONNECTING TO EQUIPMENT <br />PROVIDED BY OTHER TRADES SHALL NOT BE INSTALLED UNTIL SUCH EQUIPMENT IS INSTALLED OR UNTIL SPECIFIC <br />ROUGH -IN INSTRUCTIONS ARE PROVIDED BY THE TRADE PROVIDING THE EQUIPMENT. UNLESS OTHERWISE <br />INDICATED, CONDUITS SHALL BE CONCEALED. RACEWAYS INSTALLED IN OR UNDER SLABS, ON GRADE, OR AS <br />EXTERIOR DUCT BANKS SHALL BE PVC SCHEDULE 40 OR 80. RUN EXPOSED CONDUITS PARALLEL OR <br />PERPENDICULAR TO STRUCTURAL ELEMENTS. TWO OR MORE RACEWAYS RUN TOGETHER SHALL BE INSTALLED ON <br />GANG TRAPEZE TYPE HANGERS. SUCH RACEWAYS ASSEMBLIES SHALL BE RUN PARALLEL OR PERPENDICULAR TO <br />STRUCTURAL ELEMENTS. CONDUITS EMBEDDED IN SLABS SHALL HAVE A MINIMUM OF 1" COVER OF CONCRETE ON <br />ALL SIDES. OUTSIDE DIAMETER OF CONDUIT SHALL NOT EXCEED 1/3 OF THE SLAB THICKNESS. PROVIDE 0.25" NYLON <br />PULL TAPE IN ALL EMPTY CONDUITS. BRANCH CIRCUITS MAY UTILIZE TYPE MC ARMORED CABLE ASSEMBLY WITH <br />COPPER CONDUCTORS AND FULL SIZE EQUIPMENT GROUNDING CONDUCTORS FOR INDIVIDUAL DROPS TO DEVICES. <br />TYPE MC CABLE SHALL BE SUPPORTED AT 48" INTERVALS AND SHALL NOT LAY ON THE CEILING GRID OR INTERFERE <br />WITH THE REMOVAL OF CEILING. <br />0. CONDUCTORS: ALL BUILDING WIRE SHALL BE 600 VOLT RATED THHN OR THWN COPPER, STRANDED FOR SIZES <br />#8AWG AND LARGER, SOLID FOR SIZES 10 AND SMALLER UNLESS APPLIED FOR CONTROL. ALL BUILDING WIRE AND <br />SPECIAL CABLES FOR SYSTEMS SHALL BE INSTALLED IN A RACEWAY. ALL WIRE AND CABLE SHALL BE DELIVERED TO <br />THE JOBSITE IN ORIGINAL UNBROKEN PACKAGES, CARTONS OR REELS, WITH THE MANUFACTURERS NAME, UL <br />LABEL, AND CHARACTERISTICS OF THE PRODUCT PLAINLY VISIBLE. ALL WIRE AND CABLE SHALL BE MANUFACTURED <br />IN THE UNITED STATES OF AMERICA. WIRES SHALL BE COLOR CODED AS FOLLOWS (A,B,C,N,G): 120/208-BLACK, RED, <br />BLUE, WHITE, GREEN; 480/277 - BROWN, ORANGE, YELLOW, GRAY, GREEN. SPLICES SHALL BE COMPRESSION TYPE. <br />CONTROL CONDUCTORS SHALL BE TERMINATED WITH INSULATED CONNECTORS, T&B STAKON. 120 VOLT CIRCUITS <br />WITH HOMERUN LENGTH OVER 125 FEET AND 277 VOLT CIRCUITS WITH A HOMERUN LENGTH OVER 250 FEET SHALL <br />HAVE #10 MINIMUM HOMERUN CONDUCTORS. ALL THREE PHASE BRANCH CIRCUITS WITH A COMMON NEUTRAL <br />SHALL HAVE #10 MINIMUM NEUTRAL. <br />P. BOXES: OUTLET BOXES SHALL BE SHEET STEEL, MINIMUM 4" SQUARE, MINIMUM 1.5" DEEP, WITH PLASTER RING IN <br />PLASTER OR BRICK CONSTRUCTION. OUTLETS BOXES IN POURED CONCRETE SHALL BE CONCRETE RINGS. <br />MASONRY BOXES SHALL BE USED IN MASONRY OR TILE CONSTRUCTION. OUTLET BOXES FOR SURFACE ALUMINUM <br />RACEWAY SHALL BE 4-11/16 WITH PLASTER RINGS ORIENTED HORIZONTALLY. BOXES SHALL BE SECURELY <br />ANCHORED IN PLACE, AND SHALL BE SUPPORTED INDEPENDENT OF THE RACEWAY SYSTEM. PULL BOXES SHALL BE <br />GALVANIZED SHEET STEEL, MINIMUM 12 GAUGE, WITH SCREW COVERS, AND WELDED CONSTRUCTION. WELDS <br />SHALL BE COLD GALVANIZED. USING PERMANENT WATER PROOF WIDE BLACK MARKER, CLEARLY LABEL COVER OF <br />ALL BRANCH CIRCUIT JUNCTION AND PULL BOXES WITH PANEL AND CIRCUIT NUMBER OF CIRCUITS CONTAINED IN <br />OR PASSING THROUGH THE BOX. BRANCH CIRCUIT AND FEEDER JUNCTION AND PULL BOXES USED WITH <br />EMERGENCY FEEDERS AND CIRCUITS SHALL BE PAINTED RED. PROVIDE P-TOUCH OR DYMO LABELS ON COVER OF <br />EACH FEEDER PULL OR JUNCTION BOX INDICATING FEEDER DESIGNATION, SOURCE, LOAD, AND VOLTAGE. <br />Q. WIRING DEVICES: SWITCHES FOR LIGHTING CIRCUITS SHALL BE 120/277 VOLT, 20 AMP, A.C. ONLY, QUIET TYPE, WITH <br />GROUND BONDING SCREW, SPECIFICATION GRADE. MOMENTARY CONTACT SWITCHES SHALL BE SINGLE POLE <br />DOUBLE THROW, CENTER OFF GE #5935 OR EQUAL. DUPLEX RECEPTACLES SHALL BE 15 AMP HUBBELL 5262 OR <br />EQUAL. DEDICATED DUPLEX RECEPTACLES SHALL BE ORANGE 20AMP HUBBELL IG5362 OR EQUAL. SPECIAL <br />RECEPTACLES SHALL BE OF SIMILAR CONSTRUCTION. FACE PLATES SHALL BE SMOOTH NYLON OR THERMOSET <br />PLASTIC. ADJACENT OUTLETS SHALL BE INSTALLED IN MULTI -GANG BOXES WITH A SINGLE MULTI -GANG FACE PLATE. <br />RECEPTACLES CONNECTED TO AN EMERGENCY CIRCUIT SHALL BE RED. COORDINATE COLOR OF DEVICES AND <br />FACEPLATE WITH ARCHITECT. <br />R. GROUNDING: ALL FEEDERS AND BRANCH CIRCUITS SHALL BE PROVIDED WITH INSULATED GREEN EQUIPMENT <br />GROUNDING CONDUCTOR. CONDUIT GROUNDS ONLY ARE NOT PERMITTED. <br />S. LIGHTING: SPARE FLUORESCENT LAMPS SHALL MATCH BUILDING STANDARD UNLESS OTHERWISE NOTED. <br />INCANDESCENT LAMPS SHALL BE 130VOLT. NEW BALLASTS SHALL BE SOILD STATE ELECTRONIC. EXIT FIXTURES <br />SHALL MATCH BUILDING STANDARD. FIXTURE LOCATIONS SHALL BE AS SHOWN ON THE REFLECTED CEILING PLAN. <br />PROVIDE LAY -IN FIXTURES WITH TWO REMOVABLE CLIPS ATTACHING FIXTURE TO CEILING GRID. FLANGED FIXTURES <br />SHOWN TO BE INSTALLED IN CONTINUOUS ROWS SHALL NOT HAVE INTERMEDIATE FLANGES. ALL PENDANT <br />FIXTURES SHALL BE MOUNTED TO STRUCTURE. SEISMIC SUPPORT WIRES AND/OR COMPRESSION STRUTS FOR <br />LAY -IN FIXTURES SHALL BE SUBJECT TO LOCAL AHJ LATEST REQUIREMENTS. <br />T. FIRE ALARM DEVICES: NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH EXISTING BUILDING ADDRESSABLE <br />FIRE ALARM SYSTEM. INSTALL NEW DEVICES AND CONNECT TO NEAREST SIGNALING OR NOTIFICATION DEVICE <br />CIRCUIT WITHIN THE AREA. CONTRACTOR SHALL VERIFY CIRCUIT HAS CAPACITY FOR ADDED LOAD. SYSTEM SHALL <br />BE CERTIFIED BY FIRE ALARM VENDOR AFTER COMPLETION OF WORK. <br />U. PANELBOARDS: DEAD FRONT PANEL CONSTRUCTION WITH SEPARATELY MOUNTED INTERIOR TRIM. MAIN AND <br />BRANCH DEVICES SHALL BE BOLT -ON. MULTI -POLE BREAKERS SHALL BE COMMON TRIP. WIDTH SHALL NOT EXCEED <br />22" FOR PANELBOARD AND ENCLOSURE SHALL MATCH BUILDING STANDARD. PROVIDE GROUND BUS IN PANELBOARD <br />AND PROVIDE DEVICE MOUNTING HARDWARE WHERE A SPACE IS SCHEDULED. PANEL AND OCPD SHORT CIRCUIT <br />RATINGS SHALL BE AT LEAST 10% GREATER THAN AVAILABLE SHORT CIRCUIT CURRENT AT PANELBOARD. <br />V. DRY -TYPE TRANSFORMERS: TRANSFORMERS SHALL BE DRY -TYPE, ENCLOSED, SELF -COOLED, VENTILATED TYPE, <br />DEAD -FRONT DRIP PROOF. PRIMARY AND SECONDARY TAPS SHALL BE ACCESSIBLE FROM THE FRONT. <br />TRANSFORMERS SHALL MEET OR EXCEED BUILDING STANDARD TRANSFORMERS SPECIFICATIONS. PROVIDE AN <br />EQUIPMENT GROUNDING CONDUCTOR IN THE PRIMARY FEED TO THE TRANSFORMER, SUPPLEMENTAL GROUND TO <br />NEAREST ACCESSIBLE PRIMARY STRUCTURAL MEMBER OR EQUIPMENT ROOM GROUND BUS BAR. SIZE PER NEC <br />AND RUN IN CONDUIT WITH BOND BUSHING AT EACH END. NEUTRAL AND GROUNDING CONDUCTOR SHALL BE <br />BONDED TO ENCLOSURE. <br />SF�9F1 <br />E Noo <br />W74056 <br />S OF <br />SF�0RIDP•��`;;`� <br />o <br />Q <br />G ICi0 Digitally signed <br />4 <br />z <br />by Guido Inoa <br />J <br />nOa Alvarez <br />Date:2018.05.10 <br />A I Va reZ <br />m <br />17:29:38-04'00' <br />Q <br />U <br />z <br />Q <br />Q <br />Ui <br />U) <br />Z <br />Q <br />cm <br />w <br />w <br />J <br />0 ' <br />• <br />CONTRACT DATE: 08.13.2017 <br />BUILDING TYPE: ONE-OFF <br />PLAN VERSION: <br />SITE NUMBER: <br />STORE NUMBER: <br />SUNRISE EATERY <br />5915 GALL BLVD, <br />ZEPHYRHILLS, FL <br />ELECTRICAL <br />GENERAL <br />NOTES <br />& LEGNED <br />EO.0 <br />PLOT DATE: May 10, 2018 - 5:25pm <br />