<br />MECHANICAL GENERAL NOTES:
<br />1. COORDINATE LOCATIONS WHERE NEW DUCTWORK CROSSES EXISTING CONDUITS, ETC. PROVIDE OFFSETS AS
<br />REQUIRED.
<br />2, INSTALL FIRE DAMPERS AS REQUIRED WHENEVER NEW OR EXISTING DUCTWORK PASSES THROUGH FIRE REATED
<br />WALLS OR FLOORS. RETURN AIR OPENING IN FIRE RATED WALLS SHALL BE EQUIPPED WITH FIRE DAMPERS. SEE ARCH.
<br />DRAWINGS FOR RATED WALLS.
<br />3. CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY ENGINEER WITH ANY
<br />DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS
<br />4. COORDINATE EXACT LOCATIONS OF EQUIPMENT ON ROOF. PROVIDE DUCTED OUTSIDE AIR INTAKE DUCTS TO MAINTAIN
<br />10'-0 CLEARANCE FROM EXHAUST OR FLUE DISCHARGE OPENINGS
<br />5. NEW KITCHEN HOODS, EXHAUST FANS AND MAKE UP AIR UNIT BY KITCHEN EQUIPMENT SUPPLIER, VERIFY
<br />REQUIREMENTS AND PROVIDE GAS, ELECTRICAL CONNECTIONS AS REQUIRED. EXHAUST DUCT TO BE STAINLESS OR
<br />BLACK STEEL, ZERO CLEARANCE TO COMBUSTABLE, INSULATED WRAP. HOOD SHALL BE EQUIPPED WITH AN ANSUL
<br />FIRE SUPRESSION SYSTEM. MINIMUM AIR VELOCITY IN EXHAUST DUCTWORK SHALL BE A MINIMUM OF 1500 FPM
<br />6. COORDINATE ALL WORK WITH ALL OTHER TRADES, RESOLVE CONFLICT PRIOR TO INSTALLATION OF EQUIPMENT.
<br />COORDINATE NEW DIFFUSER LOCATIONS WITH LIGHT FIXTURES, SPRINKLER HEADS AND PIPING, CEILING GRID
<br />LOCATION PRIOR TO INSTALLATION.
<br />7. ALL NEW HVAC EQUIPMENT INCLUDING FANS, RTU AND MUA SHALL BE PROPERLY SUPPORTED FROM THE STRUCTURE.
<br />MOUNT ALL ROOFTOP UNITS ON CURBS. PROVIDE VIBRATION ISOLATORS ON ALL EQUIPMENT. ALL EQUIPMENT SHALL
<br />BE APPROVED FOR ITS SPECIFIC INTENDED INSTALLATION AND OPERATION.
<br />8. DIFFUSER PER SCHEDULE. EACH SHALL BE PROVIDED WITH BALANCING DEVICE AT DIFFUSER RUNOUT WHERE
<br />POSSIBLE AND DEVICE FACE -MOUNTED DAMPER OTHERWISE.
<br />9, THERMOSTATS FOR NEW RTU'S SHALL BE PROGRAMMABLE STYLE BY HONEYWELL. SUBMIT SHOP DRAWINGS AND
<br />VERIFY MODEL NUMBER PRIOR TO PURCHASE. THERMOSTATS MOUNTED AT 42" AFF
<br />10. PROVIDE ROOF TOP AIR HANDLING UNIT AS INDICATED ON DRAWINGS. VERIFY EXACT LOCATION WITH ROOF PLAN AND
<br />STRUCTURAL DRAWINGS. PROVIDE GAS PIPING CONNECTION AND COORDINATE ELECTRICAL CONNECTION. MOUNT ALL
<br />UNITS ON 14" ROOF CURB. ROOF CURBS ABOVE OR A SINGLE FLOOR ABOVE MUSIC INSTRUCTION OR ASSEMBLY AREAS
<br />SHALL BE PROVIDED WITH VIBRATION ISOLATION ROOF CURBS.
<br />11. PROVIDE NEW GAS SERVICE FROM NEW METER UP TO RTU'S AND EQUIPMENT GAS PIPING TO BE SCHEDULE 40 BLACK
<br />STEEL. PROVIDE METER AND PIPING CONNECTION TO ALL AHU'S DUCT FURNACES, HOT WATER HEATER, MAKE UP AIR
<br />UNITS AND KITCHEN COOKING EQUIPMENT. GAS PIPING FOR KITCHEN COOKING EQUIPMENT TO BE EQUIPPED WITH A
<br />SOLENOID SHUT-OFF VALVES CONNECTED TO HOOD FIRE SUPPRESSION SYSTEM DUCTWORK FOR GRILL HOOD (TYPE 1)
<br />SHALL BE WELDED 16 GAGE BLACK IRON, OR STAINLESS STEEL.
<br />12. MAKE UP AIR UNITS AND ROOFTOP UNIT FANS AND OUTDOOR AIR DAMPERS SHALL BE INTERLOCKED WITH EXHAUST
<br />FANS.
<br />13. TYPE I EXHAUST FAN TO TERMINATE AT A MINIMUM 40 ABOVE ROOF, PROVIDE FAN WITH 24" METAL ROOF CURB OR
<br />WITH HEIGHT SUFFICIENT FOR 18" CLEARANCE FROM ROOF FLASHING TO FAN BASE.
<br />14. ALL MECHANICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCALLY ADOPTED MECHANICAL CODE WITH
<br />ALL CURRENTLY APPLICABLE ERRATA AND AMENDMENTS.
<br />15. CONTRACTOR SHALL COORDINATE MECHANICAL WORK WITH ALL OTHER TRADES PRIOR TO FABRICATION AND
<br />INSTALLATION. DO NOT SCALE FROM DRAWINGS FOR ANY EXACT DIMENSION. SEE ARCHITECTURAL DRAWINGS AND
<br />REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF DOORS, WINDOWS, AIR DISTRIBUTION DEVICES.
<br />16. COORDINATE THE SIZE OF ALL WALL OPENINGS, ROOF OPENINGS AND EQUIPMENT PADS WITH ACTUAL EQUIPMENT
<br />PURCHASED. ALL MECHANICAL ITEMS EXTENDING THRU WALL & ROOF SHALL BE FLASHED AND COUNTER FLASHED.
<br />ALL ROOF CURBS FOR MECHANICAL EQUIPMENT SHALL BE BY MECHANICAL CONTRACTOR.
<br />17. ROUTE FULL SIZE CONDENSATE DRAINS WITH P-TRAP AND VENT ON OUTLET SIDE. PIPE 12" AWAY FROM UNIT. SPILL ON
<br />CONCRETE SPLASH BLOCK WHERE ROUTED TO ROOF.
<br />18. DUCT SMOKE DETECTORS IN SUPPLIES AND RETURNS PER LOCALLY ADOPTED CODE SHALL BE FURNISHED & WIRED
<br />BY DIV 16, INSTALLED BY DIV. 15.
<br />19. ALL DUCTWORK SIZES ARE INSIDE CLEAR FREE AREA. INCREASE SIZE WHERE REQUIRED TO INCLUDE INTERNAL
<br />INSUALTION
<br />20. MOTOR STARTERS AND DISCONNECTS SHALL BE FURNISHED UNDER DIVISION 15 AND INSTALLED BY THE ELECTRICAL
<br />CONTRACTOR. COORDINATE ELECTRICAL CHARACTERISTICS OF HVAC EQUIPMENT AND CONTROL SYSTEM
<br />SPIN -IN FITTING WITH
<br />VOLUME DAMPER
<br />METAL DUCT
<br />FOR SIZE SEE
<br />PLANS- %
<br />AIR SCOOF
<br />SUPPLY
<br />NLY) j
<br />�1
<br />LOCKING QUADRANT
<br />DEVICE NECK SIZE TO MATCH RUN OUT
<br />STEEL WIRE TO STRUCTURE
<br />SUPPORT STRAP
<br />INSULATED
<br />FLEX DUCT
<br />HANGER (TYP.)
<br />INSULATED SUPPLY ADAPTER/PLENUM
<br />T-BAR FRAME TYP.)- PROVIDE METAL
<br />FRAME AT GYP INSTALLTIONS
<br />CEILING
<br />DIFFUSER / RETURN DETAIL
<br />REQUIREMENTS (VOLTAGE/PHASE, SIGNAL TYPE, AUXILIARY CONTACTS ETCO ) PRIOR TO PURCHASING.
<br />21. CONTRACTOR SHALL NOTE THAT THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT INDICATE ALL OFFSETS,
<br />TRANSITIONS, OR OTHER APPURTENANCES REQUIRED FOR A COMPLETE HVAC SYSTEM. PROVIDE ALL EQUIPMENT
<br />NECESSARY FOR A COMPLETE SYSTEM.
<br />22. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONTROL ITEMS NECESSARY FOR THE HEATING AND COOLING
<br />FUNCTIONS OF THE AHU AND MAU. THE AHU THERMOSTAT LAYOUT IS THE HONEYWELLT6590 FAN COIL CONTROLLED.
<br />THE MAU SHALL BE PROVIDED WITH ADJUSTABLE DISCHARGE AIR CONTROL WITH DISCHARGE AIR SENSOR AND
<br />MODULATING CONTROL VALVE.
<br />23. ALL PIPING AND DUCTWORK SHALL RUN CONTINUOUSLY THROUGH FLOORS, ROOFS AND PARTITIONS. ENGINEER WILL
<br />REVIEW DUCT/PIPING SHOP DRAWINGS AT THE REQUEST OF THE CONTRACTOR. NO EXHAUST HOOD SHALL BE LEFT
<br />OPEN INTO BUILDING SPACE.
<br />24. THIS CONTRACTOR SHALL PROVIDE & INSTALL ALL MISCELLANEOUS STEEL AS REQUIRED FOR INSTALLATION OF ALL
<br />MECHANICAL ITEMS.
<br />25. ALL DIFFUSERS LOCATED IN CEILINGS WITH A NON -RETURN AIR PLENUM SHALL BE INSULATED AIR TIGHT WITH FOIL
<br />FACES 1 INCH FIBERGLASS INSULATION.
<br />26. CONTRACTOR SHALL PURCHASE AIR FILTERS FROM THE OWNER -APPROVED AIR FILTER VENDOR WHERE OWNER HAS
<br />A SUPPLIER. ALL FILTERS SHALL BE REPLACED IMMEDIATELY PRIOR TO SUBSTANTIAL COMPLETION.
<br />27. CONTRACTOR SHALL SUBMIT THE TAB AGENCY, 2 WEEKS PRIOR TO SCHEDULE TESTING AND BALANCING OF THE
<br />SYSTEM, AN UP-TO-DATE SET OF HVAC DRAWINGS, AND RELATED PRODUCT DATASUBMITTALS SUCH AS HVAC UNITS,
<br />FANS, DIFFUSERS, and CONTROL DIAGRAMS.
<br />28. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS. IT IS
<br />INTENDED THAT A COMPLETE MECHANICAL SYSTEM IS PROVIDED WITH ALL NECESSARY EQUIPMENT AND CONTROLS.
<br />29. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL SYSTEM REQUIREMENTS.
<br />30. TESTING AND BALANCE: CONTRACTOR SHALL CONTRACT AN INDEPENDENT TESTING AND BALANCING COMPANY TO
<br />TEST THE EQUIPMENT AND ADJUST THE HVAC SYSTEM TO OBTAIN THE DESIGN AIR FLOWS AS SHOWN ON PLANS. THE
<br />TAB AGENCY SHALL BE NEBB CERTIFIED AND SHALL SUBMIT TAB REPORT AS REQUIRED BY THE NEBB.
<br />31. ALL SUPPLY RETURN- AND OUTSIDE AIR DUCTWORK SHALL BE INSULATED. DUCT LINER SHALL BE 1 1/2" ELASTOMERIC
<br />RUBBER (ARMAFLEX OR EQ.); EXTERNAL INSULATION SHALL BE 2" THICK, 1 LB.CU.FT. DENSITY, FIBERGLASS TYPE,
<br />FOIL -FACED DUCT WRAP, COMMERCIAL GRADE. ALL EXPOSED DUCTWORK SHALL BE LINED. R-VALUE SHALL BE
<br />ADJUSTED PER LOCAL ENERGY CODE REQUIREMENTS. EXPOSED DUCT SHALL BE PROVIDED WITH APINT GRIP FINISH.
<br />32. PROVIDE PVC WATER HEATER "CONCENTRIC TYPE THRU THE ROOF ARRANGEMENT" VENTING ASSEMBLY FOR FRESH
<br />AIR INTAKE AND EXHAUST AS RECOMMENDED BY MANUFACTURER.
<br />33. DUCTWORK SHALL BE GALVANIZED STEEL FABRICATED PER SMACNA STANDARDS. VOLUME DAMPERS SHALL BE
<br />INSTALLED AT ALL DUCT BRANCHES AND DIFFUSER TAKE OFFS TO BE ABLE TO BALANCE THE AIR SYSTEM. DUCT SHALL
<br />BE HUNG WITH 1" WIDE DUCT STRAPS.
<br />34. EACH AC UNIT SHALL BE CONTROLLED WITH A WALL MOUNTED 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTO
<br />CHANGE OVER TO PROVIDE OCCUPIED/UNOCCUPIED MODES OF OPERATION. PROVIDE CLEAR PLASTIC COVER WITH
<br />LOCKING KEY ALL THERMOSTATS.
<br />35. ALL UNIT HEATER TO HAVE, INTERNAL DISCONNECT, MAGNETIC OVERLOAD PROTECTION; INTEGRAL TSTAT AND 24 V
<br />CONTROLTRANSFORMER.
<br />36. ALL PIPING SHALL BE INSULATED COMPLETELY AIR TIGHT WITH NO EXPOSED INSULATION MATERIAL. PROVIDE
<br />INSULATION OUTSIDE OF PIPING HANGERS OR SUPPORTS WITH RIGID INSULATION AND PIPING SADDLES AT SUPPORTS
<br />SUFFIECIENT TO PREVENT DEFORMATION OF INSULATION.
<br />37. PROVIDE SIESMIC FITTINGS AND SUPPORTS AS REQUIRED BY THE LOCAL BUILDING CODE AND SIESMIC
<br />CHARACTERISTICS FOR THE CONSTRUCTION LOCATION.
<br />38. ALL COOLING UNITS SHALL BE PROVIDED WITH DRAIN PANS AND FLOAT SIWTCHES TO PREVENT UNIT OPERATION
<br />WHERE CONDENSATE DRAINAGE CAN BE UNEXPECTEDLY INHIBITED, NO EQUIPMENT SHALL SIT DIRECTLY IN A DRAIN
<br />PAN.
<br />SUPPLY SUPPLY
<br />--4►
<br />RETURN/EXHAUST RETURN/EXHAUST
<br />45°
<br />VD
<br />SUPPLY- RETURN/EXHAUST
<br />DUCT BRANCH DETAIL
<br />AIR DEVICE SCHEDULE
<br />DESIGN
<br />MARK
<br />LAYOUT BASIS
<br />TYPE
<br />FACE SIZE
<br />MOUNTING
<br />FINISH
<br />MATERIAL
<br />NOTES
<br />S-1
<br />TITUS TMS
<br />CEILING DIFFUSER
<br />24X24/12X12
<br />2x2 T-BAR
<br />WHITE
<br />STEEL
<br />1,4
<br />S-2
<br />TITUS PAR
<br />PATTERNLESS PERF GRILLE
<br />24X24/
<br />2x2 T-BAR
<br />WHITE
<br />STEEL
<br />1,4
<br />R-1
<br />TITUS 50 F
<br />1/2" EGGCRATE RETURN
<br />24X24
<br />2X2 T-BAR
<br />WHITE
<br />ALUMINUM
<br />2
<br />NOTES
<br />1
<br />. NECK SIZE TO MATCH DUCT RUN OUT SIZE AS SHOWN ON MECHANICAL PLANS.
<br />2
<br />.PROVIDE MANUFACTURER'S ACCESSORY INSULATED PLENUM WITH RUN OUT SIZED CONNECTION.
<br />3
<br />.BALANCING DEVICE AT AIR DEVICE FACE
<br />4
<br />.BALANCING DEVICE AT RUN OUT TAKEOFF
<br />5
<br />.DIVERT BLADES TO 45 DEGREE LATERALLY AND 35 DEGREES BELOW HORIZONTAL
<br />6
<br />.3-WAY DIFFUSER
<br />I
<br />F
<br />I
<br />I END
<br />ABREVIATIONS
<br />AC
<br />ABOVE CEILING
<br />HR
<br />HOUR
<br />ACC
<br />ACCESS
<br />HW
<br />HOT WATER
<br />ACU
<br />AIR CONDITIONING UNIT
<br />HZ
<br />HERTZ
<br />AFF
<br />ABOVE FIN ISHED FLOOR
<br />IE
<br />INVERT ELEVATION
<br />AHU
<br />AIR HANDLING UNIT
<br />LAT
<br />LEAVING AIR TEMPERATURE
<br />AP
<br />ACCESS PANEL
<br />LBS
<br />POUNDS
<br />ARCH
<br />ARCHITECT
<br />LOB
<br />LEAVING DRY BULB
<br />BDD
<br />BACKDRAFT DAMPER
<br />LWB
<br />LEAVING WET BULB
<br />BTUH
<br />BTU PER HOUR
<br />LWT
<br />LEAVING WATER TEMP.
<br />CC
<br />COOLING COIL
<br />MAX
<br />MAXIMUM
<br />CCP
<br />CENTRAL CONTROL PANEL
<br />MBH
<br />THOUSAND BTU PER HOUR
<br />CD
<br />CEILIIYIG DIFFUSER
<br />EVAP
<br />EVAPORATOR
<br />CFM
<br />CUBIC FEET PER MINUTE
<br />MIN
<br />MINIMUM
<br />CG
<br />CEILING GRID
<br />MOD
<br />MOTORIZED DAMPER
<br />CONC.
<br />CONCRETE
<br />MTD
<br />MOUNTED
<br />CR
<br />CEILING REGISTER
<br />N.C.
<br />MORMALLY CLOSED
<br />CV
<br />CONTROL VALVE
<br />NIC
<br />NOT IN CONTRACT
<br />D
<br />DROP
<br />N.O,
<br />NORMALLY OPENED
<br />DB
<br />DRY BULB
<br />NO.
<br />NUMBER
<br />DIA.
<br />DIAMETER
<br />NPSH
<br />NET POSITIVE SUCTION HEAD
<br />DN
<br />DOWN
<br />NTS
<br />NOT TO SCALE
<br />DWG
<br />DRAWING
<br />OA
<br />OUTSIDE AIR
<br />EA
<br />EXHAUST AIR
<br />OD
<br />OUTSIDE DIAMETER
<br />EAT
<br />ENTERING AIR TEMP
<br />OS&Y
<br />OUTSIDE SCREW AND YOKE
<br />EDB
<br />ENTERING DRY BULB
<br />PD
<br />PRESSURE DROP
<br />EF
<br />EXHAUST FAN
<br />PSI
<br />POUNDS PER SQUARE INCH
<br />ELEV
<br />ELEVATION
<br />RA
<br />RETURN AIR
<br />ELEC
<br />ELECTRIC
<br />RM
<br />ROOM
<br />EWB
<br />ENTERING WET BULB
<br />RPM
<br />REVOLUTION PER MINUTE
<br />EWT
<br />ENTERING WATER TEMP
<br />SD
<br />SMOKE DAMPER
<br />ESP
<br />EXTERNAL STATIC PRESSUR
<br />SF
<br />SUPPLY FAN
<br />SP
<br />STATIC PRESSURE
<br />SF
<br />SUPPLY FAN
<br />EXH
<br />EXHAUST
<br />SP
<br />STATIC PRESSURE
<br />EXT
<br />EXTERNAL
<br />SPEC
<br />SPECIFICATIONS
<br />F
<br />DEGREES FAHRENHET
<br />SR
<br />SUPPLY REGISTER
<br />FC
<br />FLEXIBLE CONNECTION
<br />SS
<br />STAINLESS STEEL
<br />FCU
<br />FAN COIL UNIT
<br />TDH
<br />TOTAL DYNAMIC HEAD
<br />FD
<br />FIRE DAMPER
<br />TEMP
<br />TEMPERATURE
<br />AFG
<br />ABOVE FINISHED GRADE
<br />TG
<br />TRANSFER GRILLE
<br />FLD
<br />FLOOR DRAIN
<br />TV
<br />TURNING VANES
<br />FPI
<br />FINS PER INCH
<br />TYP.
<br />TYPICAL
<br />FPM
<br />FEET PER MINUTE
<br />UH
<br />UNIT HEATER
<br />FT
<br />FEET
<br />UC
<br />3/4" UNDERCUT
<br />GV
<br />GATE VALVE
<br />V
<br />VOLTS
<br />G
<br />GAUGE
<br />VAV
<br />VARIABLE AIR VQLUME
<br />GAL
<br />GALLON
<br />VEL
<br />VELOCITY
<br />GPH
<br />GALLONS PER HOUR
<br />VERT.
<br />VERTICAL
<br />GPM
<br />GALLONS PER MINUTE
<br />W
<br />WIDTH
<br />HP
<br />HORSE POWER
<br />W/
<br />WITHOUT
<br />HT
<br />HEIGHT
<br />W/O
<br />WITHOUT
<br />H2O
<br />WATER
<br />IWB
<br />WET BULB
<br />HORIZ, HORIZONTAL IW.C.
<br />WATER COLUMN
<br />-----------
<br />LEGEND
<br />DUCT (SINGLE LINE)
<br />THERMOSTAT
<br />EXISTING DUCT/PIPE
<br />ss
<br />REMOTE SENSOR
<br />LINED DUCT (SINGLE LINE)
<br />O
<br />HUMIDISTAT
<br />HOOD ANSUL SYSTEM PULL STATION
<br />LINED DUCT
<br />jj....,,
<br />OVERFLOW NOZZLE
<br />EXPOSED SPIRAL W/ PAINT GRIP
<br />PIPE DROP
<br />ROOF DRAIN
<br />SUPPLYNENTILATION DROP _
<br />__ _ -
<br />BALL VALVE
<br />RETURN DROP
<br />STRAINER
<br />EXHAUST DROP
<br />PRV
<br />SUPPLY DIFFUSER
<br />CHECK VALVE
<br />M
<br />METER
<br />RETURN GRILLE
<br />NAT GAS REGULATOR
<br />EXHAUST GRILLE
<br />CAP
<br />3 WAY VALVE
<br />VOLUME DAMPER
<br />2 WAY VALVE
<br />FIRE DAMPER
<br />BUTTERFLY VALVE
<br />MOTORIZED DAMPER
<br />CIRCUIT SETTER
<br />SMOKE DETECTOR
<br />FLOW CONTROL VALVE
<br />DUCT ELBOW WITH VANES
<br />-SINGLE LINE (EXCLUDE VANES IN
<br />GAGE
<br />GREASE EXHAUST)
<br />THERMOMETER
<br />DUCT ELBOW WITH VANES
<br />PT PLUG
<br />(EXCLUDE VANES IN GREASE EXHAUST)
<br />PUMP
<br />RADIUS ELBOW
<br />DOUBLE CHECK VALVE
<br />RPZ CHECK
<br />FLEX DUCT RUN OUT
<br />FLEXIBLE CONNECTION
<br />FLEX PIPE/CONNECTION
<br />AUTO AIR VENT
<br />INLINE CABINET FAN
<br />FROSTAT
<br />CEILING CABINET FAN
<br />UNION
<br />HORIZ. UNIT HEATER
<br />CEILING UNIT HEATER
<br />INTAKE/VENT HOOD
<br />EXHAUST/FLUE VENT HOOD
<br />ROOF FAN
<br />GAS PIPING
<br />CW PIPING
<br />HW PIPING
<br />HOT WATER RECIRCULATION PIPING
<br />VENT PIPING
<br />SANITARY PIPING (LONG DASH)
<br />GREASE WASTE (SHORT DASH)
<br />EXISTING PACKAGED GAS/ELECTRIC ROOFTOP UNIT SCHEDULE
<br />MIN
<br />FAN
<br />COOLING
<br />COOLING
<br />HEATING
<br />HEATING
<br />NOM
<br />UNIT
<br />QTY
<br />FAN
<br />OA
<br />FAN
<br />MOTOR
<br />TOTAL
<br />SENSIBLE
<br />MBH
<br />MBH
<br />HEATING
<br />VOLTS/
<br />MARK
<br />SERVES
<br />MODEL
<br />TONS
<br />CONFIGURATION
<br />COMPR.
<br />CFM
<br />CFM
<br />ESP
<br />HP
<br />MBH
<br />MBH
<br />OUTPUT
<br />INPUT
<br />STAGES
<br />PHASE
<br />RTU-1
<br />BOH
<br />TRANE YHC120
<br />10
<br />DOWNFLOW
<br />1
<br />4000
<br />0.5
<br />113.97
<br />94.06
<br />120
<br />150
<br />1
<br />208/3
<br />RTU-2
<br />BOH
<br />TRANE YHC120
<br />10
<br />DOWNFLOW
<br />1
<br />4000
<br />0,5
<br />113.97
<br />94.06
<br />120
<br />150
<br />1
<br />208/3
<br />RTU-3
<br />DINING
<br />TRANE YHC120
<br />10
<br />DOWNFLOW
<br />1
<br />4000
<br />0.5
<br />113.97
<br />94.06
<br />120
<br />150
<br />1
<br />208/3
<br />RTU-4
<br />DINING
<br />TRANE YHC060
<br />5
<br />DOWNFLOW
<br />1
<br />2000
<br />250
<br />0.5
<br />---
<br />63.49
<br />47.33
<br />48
<br />60
<br />1
<br />208/3
<br />NOTE 1: INDOOR COIL EAT = 80/67 FOR COOLING, 70 FOR HEATING.
<br />NOTE 2: OUTDOOR COIL EAT = 95 FOR COOLING, 17 FOR HEATING.
<br />NOTE 3: ESP DOES NOT INCLUDE FILTERS. FAN PERFORMANCE FOR DIRECT DRIVE UNITS IS AT HIGH SPEED.
<br />NOTE 4: PROVIDE HINGED ACCESS DOORS, UNIT MOUNTED DISCONNECT AND UNPOWERED RECEPTACLE, CONDENSER COIL GUARDS, STAINLESS STEEL HEAT EXCHANGER.
<br />NOTE 5: FACTORY MOUNTED SMOKE DETECTOR IN SUPPLY AND RETURN COMPARTMENTS AND INTERNAL FLOAT SWITCH WIRED FOR UNIT SHUTDOWN.
<br />NOTE 6: PROVIDE 2-POSITION MOTORIZED DAMPER AT OUTDOOR AIR HOOD.
<br />NOTE 7: ECONOMIZER WITH COMP ENTHALPY CONTROL MODULE. POWER EXHAUST FOR UNITS ABOVE 2000 CFM, BAROMETRIC RELIEF FOR 2000 CFM AND LOWER.
<br />NOTE 8: PROVIDE MANUFACTURER ACCESSORY ROOF CURB. CURB ADAPTORS SHALL REQUIRE SPECIFIC ENGINEER APPROVAL.
<br />NOTE 9: PROVIDE SPRING ISOLATION TYPE ROOF CURB.
<br />NOTE 10: COORDINATE VOLTAGES WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING. SUBMITTALS SHALL BE REQUIRED TO HAVE ELECTRICAL ENG. APPROVAL
<br />NOTE 13: PROVIDE REFRIGERANT HOT GAS REHEAT DEHUMIDIFICATION.
<br />NOTE 15: PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT WITH REMOTE SENSOR.
<br />END
<br />EXHAUST/VENTILATION FAN SCHEDULE
<br />MOTOR
<br />VOLTS/
<br />FAN
<br />TAG
<br />MODEL
<br />TYPE
<br />SERVES
<br />CFM
<br />ESP
<br />HP
<br />RPM
<br />SONES
<br />DRIVE
<br />PHASE
<br />INTERLOCK
<br />NOTES
<br />F-1
<br />HOOD
<br />HOOD
<br />1,350
<br />0.925
<br />0.75
<br />1,164
<br />11.8
<br />DIRECT
<br />120/1
<br />TIMECLOCK SET FOR OCCUPIED SCHEDULE
<br />F-2
<br />HOOD
<br />HOOD
<br />2000
<br />0.931
<br />0.75
<br />1377
<br />16.1
<br />DIRECT
<br />120/1
<br />TIMECLOCK SET FOR OCCUPIED SCHEDULE
<br />F-3
<br />HOOD
<br />HOOD
<br />2000
<br />0.93
<br />0.75
<br />1377
<br />16.1
<br />DIRECT
<br />120/1
<br />TIMECLOCK SET FOR OCCUPIED SCHEDULE
<br />F-4
<br />HOOD
<br />HOOD
<br />3000
<br />1.122
<br />1.5
<br />1120
<br />13.6
<br />DIRECT
<br />120/1
<br />TIMECLOCK SET FOR OCCUPIED SCHEDULE
<br />F-5
<br />ACED
<br />DOWNBLAST
<br />RESTROOMS
<br />300
<br />0.250
<br />1/3
<br />1,325
<br />8.9
<br />DIRECT
<br />1 120/1
<br />TIMECLOCK SET FOR OCCUPIED SCHEDULE
<br />1,2,3,4
<br />1. COORDINATE VOLTAGES WITH ELECTRICAL DRAWINGS.
<br />2. PROVIDE INDOOR FANS WITH BACKDRAFT DAMPER, SPRING/NEOPRENE ISOLATION HANGERS AND ACCESSORY ROOF CAP AT SIZE INDICATED ON DRAWINGS.
<br />END
<br />Z
<br />I"I
<br />O
<br />W
<br />co
<br />N
<br />a
<br />�00
<br />Lo
<br />U
<br />W
<br />�
<br />z
<br />w Q
<br />I-
<br />LIJ
<br />UzU�=
<br />N�
<br />N
<br />U
<br />N
<br />Q
<br />V�
<br />LU
<br />z
<br />m
<br />.
<br />M�
<br />• E
<br />0. 7 • . o
<br />Q
<br />4 STAT OF • ��Lu
<br />i�0 •. Al .• �� z
<br />�O �pP w
<br />SS�OIVA •E � �,
<br />#oil Its
<br />m
<br />q
<br />c5
<br />z
<br />q
<br />Q
<br />w
<br />Y
<br />U)
<br />Z
<br />Q
<br />00
<br />w
<br />w
<br />J
<br />18014
<br />0
<br />CONTRACT DATE: 08-13.2017
<br />BUILDING TYPE: ONE-OFF
<br />PLAN VERSION:
<br />SITE NUMBER:
<br />STORE NUMBER:
<br />SUNRISE EATERY
<br />5915 GALL BLVD.
<br />ZEPHYRHILLS, FL
<br />MECHANICAL
<br />SCHEDULES
<br />AND DETAILS
<br />Mo. 1
<br />PLOT DATE:
<br />
|