My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5915 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5915 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:58:39 PM
Creation date
1/21/2025 3:38:22 PM
Metadata
Fields
Template:
Building Plans
Street #
5915
Location
Gall Blvd
Contractor
Osage Contractors LLC
Building Plans - Permit #
20581
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOFTOP PACKAGE UNIT W/GAS HEAT SCHEDULE <br />(OWNER SUPPLIED AND CONTRACTOR INSTALLED) <br />COOLING DATA <br />HEATING DATA <br />TOTAL <br />SENSIBLE <br />ENTERING <br />GAS <br />GAS <br />MODEL <br />COOLING <br />CFM <br />CFM <br />EXT. <br />COMP. <br />WEIGHT <br />MARK <br />MANUFACTURER <br />NUMBERS <br />CAPACITY <br />S.A. <br />O.S.A <br />SP. IN <br />COOLING <br />COOLING <br />AIR TEMP <br />EFFICIENCY <br />FAN MOTOR <br />INPUT <br />OUTPUT <br />STAGES <br />MOTOR <br />MCA <br />MOCP <br />V/PH/HZ <br />IN LBS. <br />NOTES <br />(TONS) <br />IN H2O <br />MBH <br />MBH <br />D.B./W.B. <br />EER <br />HP <br />MBH <br />MBH <br />RLA <br />RTU-1 <br />YORK <br />ZR049 <br />4 <br />1600 <br />350 <br />0.8 <br />43.2 <br />32.6 <br />80/67 <br />14.5 <br />1.5 <br />80 <br />65 <br />2 <br />11.9 <br />24.3 <br />35 <br />208/3/60 <br />1100 <br />A-J <br />RTU-2 <br />YORK <br />ZE048 <br />4 <br />1600 <br />350 <br />0.8 <br />50.8 <br />36.7 <br />80/67 <br />14 <br />1.5 <br />75 <br />60.8 <br />2 <br />13.7 <br />23.7 <br />30 <br />208/3/60 <br />725 <br />A-H <br />RTU-3 <br />YORK <br />ZE060 <br />5 <br />1950 <br />500 <br />0.8 <br />61.1 <br />45.4 <br />80/67 <br />14 <br />1.5 <br />75 <br />60.8 <br />2 <br />16 <br />28.7 <br />35 <br />208/3/60 <br />775 <br />A-H <br />NOTES <br />A. PROVIDE LOW VOLTAGE, PROGRAMMABLE, AUTO -CHANGEOVER THERMOSTAT WITH CLEAR PLASTIC COVER - REF: SHEET M5 ITEM #10 <br />B. REFER TO ELECTRICAL SHEETS FOR SMOKE DETECTOR REQUIREMENTS. <br />C. PROVIDE WITH MANUFACTURERS 14" ROOF CURB WITH BURGLAR BARS. <br />D. PROVIDE UNIT WITH DIFFERENTIAL ENTHALPY TYPE ECONOMIZER WITH BAROMETRIC <br />RELIEF AND <br />CONTROLS INTERFACE. <br />E. PROVIDE UNIT WITH UNPOWERED GFCI CONVENIENCE OUTLET. <br />F. PROVIDE UNIT WITH FACTORY INSTALLED HINGED ACCESS PANELS. <br />G. DIVISION 16 PROVIDED DISCONNECT SWITCH. <br />H. PROVIDE DRAIN PAN WITH FLOAT SWITCH, UNIT SHALL SHUT DOWN UPON ALARM FROM <br />FLOAT SWITCH. <br />J. PROVIDE UNIT WITH MAGNADRY DEHUMIDIFICATION RE -HEAT COIL. <br />EXHAUST AIR FAN SCHEDULE <br />(OWNER SUPPLIED AND CONTRACTOR INSTALLED) <br />S.P. IN <br />MAX <br />MAX <br />MARK <br />TYPE <br />CFM <br />INCHES <br />FAN <br />FAN TIP <br />SONES <br />FAN <br />WEIGHT <br />MOTOR <br />V/o/HZ <br />BASIS <br />NOTES <br />IN H2O <br />RPM <br />SPEED <br />DRIVE <br />IN LBS. <br />H.P. <br />DESIGN <br />EF - 1 <br />PIZZA OVEN HOOD EXH. FAN <br />1210 <br />1.50" <br />1352 <br />-- <br />15.5 <br />DIRECT <br />97 <br />3/4 <br />115/1/60 <br />CAPTIVE ARE DU85HFA <br />A,B <br />EF-2 <br />WINGSTREET FRYER HOOD EXH. FAN <br />600 <br />0.85" <br />1439 <br />-- <br />10.8 <br />DIRECT <br />74 <br />1/3 <br />115/1/60 <br />CAPTIVE ARE DU33HFA <br />A,B <br />EF-3 <br />RESTROOM EXH. FAN <br />90 <br />0.25" <br />861 <br />-- <br />1.6 <br />DIRECT <br />18 <br />69 WATTS <br />115/l/60 <br />COOK GC-144 <br />C <br />NOTES: <br />A. ACCESSORIES INCLUDED: EXTENDED ROOF CURB (HEIGHT AS REQUIRED TO MEET CODE - DISCHARGE <br />@ MIN. <br />40" ABOVE ROOFLINE); NEMA 3R NFDS; <br />CONSTRUCTED TO MEET NFPA 96 & UL 762; WITH U.L. LISTING REQUIRED. <br />B. REFER TO ELECTRICAL PROJECT DOCUMENTS FOR ALL REQUIRED INTERLOCK. <br />VERIFY PROPER OPERATION. <br />C. ACCESSORIES INCLUDED: VENTED ROOF CURB WITH BACKDRAFT DAMPER. <br />MAKE-UP <br />AIR UNIT SCHEDULE <br />(OWNER SUPPLIED AND CONTRACTOR INSTALLED) <br />MARK <br />TYPE <br />CFM <br />TOTAL <br />FAN <br />DRIVE <br />EXT. <br />S.P. IN <br />IN H2O <br />INPUT <br />MBH <br />OUTPUT <br />MBH <br />MAXIMUM <br />RPM <br />WEIGHT <br />IN LBS. <br />MOTOR <br />H.P. <br />V/o/HZ <br />BASIS OF DESIGN <br />NOTES <br />SF-1 <br />FILTERED MAKE-UP AIR SUPPLY FAN <br />930 <br />BELT <br />0.50" <br />- <br />832 <br />196 <br />1 <br />115/1/60 <br />CAPTIVE AIRE Al-G10 <br />A,B <br />NOTES: <br />A. ACCESSORIES INCLUDED: 20" ROOF CURB - ALUMINUM; NEMA 3R NFDS; 2" WASHABLE FILTERS REQUIRED; WITH U.L. LISTING. <br />B. REFER TO ELECTRICAL PROJECT DOCUMENTS FOR ALL REQUIRED INTERLOCKS. <br />GRILLE, REGISTER, AND DIFFUSER SCHEDULE <br />(CONTRACTOR TO FURNISH AND INSTALL) <br />FACE <br />MOUNTING <br />FACE SIZE <br />MARK <br />MANUFACTURER <br />MODEL <br />TYPE <br />LOCATION <br />(IN) <br />NOTE <br />CSD1 <br />TITUS <br />TMS-AA <br />LOUVERED <br />CEILING <br />24"x24" <br />A,B,D,E,F,G,H,L <br />CSD2 <br />TITUS <br />TMS-AA <br />LOUVERED <br />CEILING <br />12"xl2" <br />A,B,D,E,F,G,H <br />CSD3 <br />TITUS <br />TMS-AA <br />LOUVERED <br />CEILING <br />24"x24" <br />A,B,C,E,F,G,H <br />CRG <br />TITUS <br />350FLF <br />LOUVERED <br />CEILING <br />22"x22" <br />D,E,F,G,H,J,K <br />CEG <br />TITUS <br />350FL <br />LOUVERED <br />CEILING <br />12"xl2" <br />A,D,E,F,G,J <br />NOTES: <br />A. NECK SIZE SHOWN ON DRAWINGS. <br />B. 4-WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. <br />C. BAKED ENAMEL FINISH, BLACK. <br />D. BAKED ENAMEL FINISH, WHITE. <br />E. PROVIDE NECK FOR DUCT CONNECTION. <br />F. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. <br />G. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATED WITH ARCHITECTURAL REFLECTED CEILING PLAN. <br />H. ALUMINUM CONSTRUCTION, <br />J. FRONT BLADES PARALLELTO LONG DIMENSION. <br />K. CONTRACTOR TO SUPPLY INITIAL FILTERS - (1) 24N24" 1"THICK FIBERGLASS FILTER REQUIRED, <br />L. PROVIDE SECTORIZING BAFFLESAS NEEDED TO MATCH AIRFLOW ON PLANS. <br />AIR BALANCE SCHEDULE <br />EQUIPMENT LABELS <br />& DESCRIPTIONS <br />TOTAL <br />AIRFLOW <br />PER UNIT <br />(CFM) <br />RECIRCULATED <br />RETURN <br />AIRFLOW <br />(CFM) <br />FRESH <br />"OUTSIDE" <br />AIRFLOW <br />(CFM) <br />EXHAUST <br />AIRFLOW <br />(CFM) <br />BUILDING <br />PRESSURE <br />(CFM) <br />REMARKS <br />RTU-1 <br />1600 <br />1250 <br />350 <br />- <br />350 <br />RTU - 2 <br />1600 <br />1250 <br />350 <br />- <br />350 <br />RTU - 3 <br />1950 <br />1450 <br />500 <br />500 <br />EF - 1 (PIZZA OVEN HOOD) <br />1210 <br />-- <br />- <br />-1210 <br />-1210 <br />EF - 2 (FRYER HOOD) <br />600 <br />-- <br />- <br />-600 <br />-600 <br />EF - 3 (TOILET EXHAUST) <br />90 <br />-- <br />- <br />-90 <br />-90 <br />SF-1 <br />930 <br />-- <br />930 <br />930 <br />RESULTING BUILDING PRESSURIZATION (CFM) * <br />* RESULTING BUILING PRESSURIZATION = (+FRESH/OUTSIDEAIR FLOW) + (-EXHAUSTAIR FLOW); <br />IF NET AIRFLOW IS "+" CFM = BLDG. POSITIVE PRESSURE <br />IF NETAIRFLOW "-" CFM = BLDG. NEGATIVE PRESSURE. <br />230 <br />ROOF HOOD <br />(CONTRACTOR TO FURNISH AND INSTALL) <br />MODEL <br />CFM <br />THROAT <br />PRESSURE <br />WEIGHT <br />MARK <br />MANUFACTURER <br />NUMBERS <br />SERVICE <br />SIZE <br />DROP <br />IN LBS. <br />NOTES <br />(IN) <br />(IN H20) <br />RH - 1 <br />GREENHECK <br />GRSR8 <br />EXHAUST <br />90 <br />8 <br />0.08 <br />7 <br />A,B,C <br />NOTES <br />A. PROVIDE WITH MANUFACTURERS 14" ROOF CURB WITH BURGLAR <br />BARS. <br />B. PROVIDE WITH BIRDSCREEN. <br />C. PROVIDE WITH BACKDRAFT DAMPER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.