Laserfiche WebLink
NOTE: <br />PLUMBING FIXTURES ON THIS PLUMBING SCHEDULE SHALL BE FURNISHED BY OWNER AND INSTALLED BY PLUMBING CONTRACTOR, EXCEPT WHERE NOTED SUPPLIED BY PLUMBING CONTRACTOR. NOTIFY OWNER IMMEDIATELY IF QUANTITIES SHOWN ARE INACCURATE OR IF CODES REQUIRE <br />ADDITIONAL PLUMBING FIXTURES. PLUMBING CONTRACTOR SHALL FURNISH EVERYTHING NECESSARY FOR A COMPLETE INSTALLATION OF THESE PLUMBING FIXTURES. <br />BY PLUMBING <br />PLUMBING <br />CORRESPONDING <br />QTY' <br />CONTRACTOR <br />FIXTURE <br />SOIL OR <br />VENT <br />COLD <br />HOT <br />TEMP'D <br />DESCRIPTION <br />FIXTURE <br />NPC EQUIP. # <br />WASTE <br />WATER <br />WATER <br />WATER <br />MANUFACTURER / MODEL NUMBER <br />SUPPLY <br />INSTALL <br />REDUCED <br />BFP 002 <br />1 <br />• <br />• <br />PRESSURE <br />1 1/2 <br />__ <br />__ <br />REDUCED PRESSURE ASSEMBLY WITH ATMOSPHERIC VENT, AND STRAINER. PIPE VENT <br />WATTS SERIES 919QT <br />BACKFLOW <br />DISCHARGE DRAIN LINE TO NEAREST DRAIN WITH PROPER AIR GAP. ASSE 1022 APPROVED. <br />PREVENTER <br />DW 002 <br />Z3-002 <br />1 <br />• <br />DISHWASHER <br />INDIRECT <br />__ <br />1/2 <br />__ <br />SINGLE RACK, CORNER, LOW EVERGY DISHWASHER. HOT WATER INLET - 1/2" NPT FEMALE. 45 GALLONS PER HOUR <br />a <br />AUTO CHLOR /MODEL: #A5 WATER SAVER <br />9140 F, 7 GPM (RECOMMENDED WATER TEMPERATURE). THIS UNIT DOES NOT PRODUCE STEAM OR HEAT, <br />ET 001 <br />1 <br />• <br />EXPANSION <br />TANK <br />-- <br />3/4" <br />-- <br />-_ <br />EXPANSION TANK, STEEL, EXPANSION MEMBRANE 150 PSI, MAX. TEMP. 200° F, 4.5 GALLON CAPACITY. <br />WATTS SERIES PLT-12-M1 <br />FCO 003 <br />• <br />• <br />FLOOR <br />__ <br />__ <br />__ <br />__ <br />__ <br />CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED <br />ZURN / MODEL: #Z1400 <br />3 <br />CLEANOUT <br />HEAVY CAST IRON COVER. <br />FD 003 <br />• <br />• <br />FLOOR DRAIN <br />3" <br />2" <br />__ <br />__ <br />COATED CAST IRON FLOOR DRAIN WITH FLANGE, INTEGRAL CLAMPING COLLAR, <br />ZURN / MODEL: #Z-415-6H <br />6 <br />(3) <br />BOTTOM OUTLET AND ADJUSTABLE NICKEL -BRONZE ROUND STRAINER. <br />FS 002 <br />• <br />• <br />FLOOR SINK <br />3" <br />2" <br />-- <br />-- <br />PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER <br />ZURN / MODEL: #FD-2370-PV4-DS-H <br />2 <br />AND LOOSE SET PVC SLOTTED TOP GRATE, <br />GI 001 <br />Z4-001 <br />1 <br />GREASE <br />2 - 4" <br />2 - 2" <br />-- <br />-- <br />-- <br />1000 GALLON PREFABRICATED EXTERIOR UNDERGROUND CONCRETE UNIT. <br />(EXISTING) <br />INTERCEPTOR <br />WHITE VITREOUS CHINA, WALL MOUNTED WITH HANGERS, OVERFLOW, ADA COMPLIANT, DRILLED FOR CONCEALED ARM <br />LV 001 <br />1 <br />• <br />LAVATORY <br />1-1/2" <br />1-1/2" <br />1/2" <br />-' <br />1/2" <br />CARRIER, 4" CENTERS, 21-1/4"x18-1/8" WITH SINGLE LEVER TYPE FAUCET, ADA COMPLIANT. MECHANICAL CONTRACTOR <br />KOHLER "KINGSTON" / MODEL: #K-2005 <br />TO PROVIDE AND INSTALL ADA COMPLIANT PREMANUFACTURED INSULATING JACKET ON DRAIN AND WATER LINES <br />WITH T&S #B-2460 LAVATORY FAUCET <br />BELOW SINK. LAVATORY IS SUPPLIED WITH CONCEALED ARM CARRIER. SEE DETAIL 11/P4 FOR LAV CARRIER DETAIL, <br />MIXING <br />THERMOSTATIC MIXING VALVE, SOLID BRASS BODY, INTEGRAL CHECKS WITH SCREENS. ASSE 1070 <br />POWERS / MODEL: #e480-00 WITH <br />MV 002 <br />4 <br />• <br />• <br />VALVE <br />-- <br />-- <br />1/2" <br />1/2" <br />1/2" <br />LISTED. SET MIXING VALVE AT OUTPUT AT 110 °F <br />ELMDOR DW10X10 ACCESS DOOR. <br />VERIFY <br />SA 003 <br />WITH <br />• <br />• <br />SHOCK <br />4 <br />__ <br />STAINLESS STEEL CASING WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN. <br />ZURN / SHOKTROL #Z1700 <br />PLUMB. <br />ARRESTOR <br />SIZED PER PDI WH2O1, SIZE "B". <br />PLAN <br />S1 003 <br />Z5-003 <br />1 <br />• <br />3-COMP. SINK <br />INDIRECT <br />-- <br />1/2" <br />1/2" <br />-- <br />3 COMPARTMENT SINK, FAUCET W/ HANDLES AND DRAIN. <br />AERO MANUFACTURING CO. <br />S3 004 <br />Z7-004 <br />• <br />HAND SINK <br />W/ KNEE <br />1 1/2" <br />1 1/2" <br />'- <br />1/2" <br />STAINLESS STEEL HAND SINK, WALL HUNG. INCLUDES A 6" GOOSENECK STAINLESS STEEL <br />AERO MANUFACTURING CO. / MODEL: <br />3 <br />PEDAL <br />FAUCET W/ KNEE PEDAL VALVE. <br />#HSK-SKV <br />S5 003 <br />Z9 003 <br />1 <br />• <br />MOP SINK <br />3„ <br />2„ <br />1/2„ <br />1/2„ <br />__ <br />ONE PIECE MOP BASIN MOLDED FROM HIGH IMPACT RESISTANT DURASTONE STRUCTURAL FIBERGLASS, <br />AND FAUCET. FAUCET INCLUDES VACUUM BREAKER. <br />MUSTEE / MODEL: #63M <br />AND T&S FAUCET #B2465 <br />24"x2410" DEEP <br />WHITE VITREOUS CHINA, CHROME LEFT HAND TRIP LEVER, ELONGATED BOWL, HIGH EFFICIENCY <br />AMERICAN STANDARD "CADET PRO RIGHT HEIGHT" TANK MODEL <br />C2 001 <br />1 <br />• <br />WATER <br />4" <br />2" <br />1/2" <br />'� <br />- <br />TOILET (HET) ULTRA -LOW CONSUMPTION (4,8 LPF/1.28 GPF) WITH BEMIS COMMERCIAL � <br />#4188A.164 LEFT HAND TRIP LEVER, BOWL MODEL #3517A.101 <br />CLOSET <br />HEAVY-DUTY PLASTIC TOILET SEAT #1955CT. <br />WITH BEMIS COMMERCIAL TOILET SEAT MODEL #1955CT <br />CO 003 <br />• <br />WALL <br />_ <br />CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS <br />ZURN / MODEL: #Z-1446-BP <br />2 <br />CLEANOUT <br />PLUG, WITH STAINLESS STEEL ACCESS COVER. <br />ULTRA HIGH EFFICIENCY WATER HEATER, 60 GALLON STORAGE TANK WITH VITRAGLAS LINING, 125,000 BTU INPUT, <br />WH 003 <br />Z13-003 <br />1 <br />• <br />WATER <br />HEATER <br />-- <br />1" <br />1" <br />-- <br />NATURAL GAS, DIRECT VENT, TEMPERATURE AND PRESSURE RELIEF VALVE, INSULATED FOR ENERGY CONSERVATION <br />BRADFORD WHITE / MODEL: #EF-60T-125 <br />TO MEET FEDERAL STANDARDS. PROVIDE WITH CONCENTRIC VENT TERMINATION KIT P/N 239-44069-01. <br />SYSTEM SERVED <br />MATERIAL <br />FITTINGS & JOINTS <br />DOMESTIC WATER <br />BELOW FLOOR OR GRADE <br />TYPE'K' SOFT COPPER <br />NONE PERMITTED <br />DOMESTIC WATER <br />ABOVE FLOOR OR GRADE <br />TYPE'L' HARD DRAWN COPPER <br />WROUGHT COPPER, SOLDERED <br />WASTE & VENT <br />PVC-DWV, ASTM D-2665 <br />HUB WITH PVC CEMENT <br />GAS <br />SCHEDULE 40 BLACK STEEL <br />MALLEABLE IRON, SCREWED <br />OR WELDED <br />PLUMBING SCHEDULE NTS <br />SYMBOLS <br />ABBREV. <br />DESCRIPTION <br />X-X 0001 <br />PLUMBING ITEM DESIGNATION <br />O <br />KITCHEN EQUIPMENT NUMBER: REFER TO KITCHEN <br />EQUIPMENT DRAWINGS FOR DESCRIPTION. <br />C <br />CONDENSATE DRAIN <br />- CW <br />COLD WATER <br />- HW <br />HOT WATER <br />G <br />GAS / GAS STUB <br />GW <br />SOIL OR WASTE (GREASE WASTE) <br />- SW <br />SOIL OR WASTE (SANITARY) <br />TW <br />PREMIXED TEMPERATURE WATER <br />VENT LINE <br />Q <br />FLOOR DRAIN <br />UFLOOR <br />SINK <br />Q <br />FLOOR CLEANOUT <br />A <br />WALL CLEANOUT <br />VTR <br />VENT THRU ROOF <br />SHUT-OFF GAS COCK <br />v, <br />FIRE SUPPRESSION SYSTEM <br />SOLENOID GAS SHUT-OFF <br />2 <br />1. THE WORK UNDER PLUMBING SECTION SHALL INCLUDE ALL LABOR, SERVICES, 27. CONTRACTOR TO PROVIDE TRAP PRIMER FOR FLOOR DRAIN IN RESTROOM AND <br />MATERIALS, EQUIPMENT, AND PERFORMANCE OF ALL WORK REQUIRED FOR THE WHERE REQUIRED BY CODES. CONTRACTOR TO PROVIDE DEEP SEAL TRAPS FOR <br />INSTALLATION OF ALL PLUMBING WORK, AS SHOWN ON THE DRAWINGS AND FLOOR DRAINS WITHOUT TRAP PRIMERS. <br />HEREIN SPECIFIED. <br />2. ALL MATERIALS SHALL BE NEW AND SHALL MEET REQUIREMENTS OF ASTM <br />SPECIFICATIONS AND SHALL BE APPROVED BY LOCAL CODES. <br />3. PROVIDE ENGINEER WITH SUBMITTALS ON ALL MATERIALS TO BE FURNISHED AS <br />SPECIFIED, OR AS AN EQUAL, EQUIPMENT SUBMITTALS SHALL BE APPROVED BY <br />ENGINEER BEFORE CONSTRUCTION CAN BEGIN. <br />4. SHOULD THERE BE ANY DISCREPANCIES OR A QUESTION OF INTENT, REFER THE <br />MATTER TO THE ENGINEER FOR A DECISION BEFORE ORDERING ANY EQUIPMENT <br />OR MATERIALS, OR BEFORE STARTING ANY RELATED WORK. <br />28. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE <br />PLUMBING CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH <br />EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY <br />INSTALLATION. <br />29. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT <br />SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILING SHALL BE INSTALLED <br />BEHIND AN ACCESS PANEL. <br />30. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM I <br />ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR INTAKE. <br />5. WHERE WORK, CONNECTS TO THAT OF ANOTHER TRADE OR TO PIPING OR 31. PLUMBING CONTRACTOR SHALL PROVIDE GAS PIPING TO UNITS AND ALL FINAL <br />EQUIPMENT IN PLACE, FIELD MEASUREMENTS SHALL BE MADE TO MAKE CONNECTIONS REQUIRED FOR OPERATION. <br />CONNECTING WORK COME TRUE AND LINE UP WITH THE ITEM BEING CONNECTED. <br />6. WHERE WORK OF OTHER TRADES CONNECTS TO EQUIPMENT WHICH IS APART OF <br />THIS TRADE, PROVIDE PROPER CONNECTION(S) TO SUCH EQUIPMENT. <br />7. MINOR ITEMS AND ACCESSORIES OR DEVICES REASONABLY INFERRED AS <br />NECESSARY TO THE COMPLETE AND PROPER INSTALLATION AND OPERATION OF <br />ANY SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR FOR SUCH SYSTEM, <br />WHETHER OR NOT THEY ARE SPECIFICALLY CALLED FOR BY THE SPECIFICATIONS <br />OR DRAWINGS. <br />8. CAREFULLY CHECK AND COORDINATE THE LOCATION AND LEVEL OF ALL PIPES, <br />DUCTS, ETC. RUN PRELIMINARY LEVELS AND CHECK WITH ALL OTHER <br />CONTRACTORS SO THAT CONFLICTS IN ALL LOCATIONS MAY BE AVOIDED. <br />9. ALL WORK SHALL BE EXECUTED AND INSPECTED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF ALL FEDERAL, STATE, AND LOCAL CODES, LAWS, <br />ORDINANCES, RULES, AND REGULATIONS, AND OSHA REQUIREMENTS <br />APPLICABLE TO THE PARTICULAR CLASS OF WORK. <br />10. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF OTHER <br />CONTRACTORS ON THE JOB IN ORDER THAT THERE BE NO DELAY 1N THE PROPER <br />INSTALLATION AND COMPLETION OF SEVERAL PARTS OF THE WORK. THIS <br />CONTRACTOR SHALL BE RESONSIBLE FOR THE COORDINATION OF HIS WORK <br />WITH THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND ALL OTHER TRADES <br />ON THE JOB, AND SHALL FIT HIS WORK TO AVOID INTERFERENCE. ANY <br />RELOCATIONS OF DUCTWORK, EQUIPMENT, PIPING, VALVES, ETC. REQUIRED <br />BECAUSE OF AN INTERFERENCE SHALL BE MADE AT THIS CONTRACTOR'S <br />EXPENSE WITHOUT ADDITIONAL COST TO THE OWNER. <br />11. ALL PIPE, TUBE, AND FITTINGS SHALL COMPLY WITH LATEST ISSUED CODE AND <br />STANDARDS, UNLESS INDICATED OTHERWISE BY LOCAL CODES. <br />12. WELDING PROCEDURES, WELDERS, AND OPERATORS SHOULD BE CERTIFIED IN <br />ACCORDANCE WITH ASME B31.1 OR ASME B31.9, AS APPLICABLE, FOR SHOP AND <br />PROJECT SITE WELDING OF PIPE WORK. <br />13. CERTIFY WELDING OF PIPING WORK USING STANDARD PROCEDURE <br />SPECIFICATIONS BY, AND WELDERS TESTED UNDER SUPERVISION OF, NATIONAL <br />CERTIFIED PIPE WELDING BUREAU (NCPWB) SUPERVISION. <br />14. COPPER TUBE AND FITTINGS <br />A. COPPER TUBE: ASTM B88 TYPE "L", AS INDICATED, FOR EACH SERVICE; <br />HARD -DRAWN OR SOFT -DRAWN TEMPER, AS INDICATED, EXCEPT AS <br />OTHERWISE INDICATED. <br />B. CAST COPPER SOLDER JOINT FITTINGS: ANSI B16.18 (ACID FREE). <br />C. WROUGHT COPPER SOLDER JOINT FITTINGS: ANSI B16.22 (ACID FREE) <br />16. BRASS PIPE FITTINGS <br />A. RED BRASS PIPE: ASTM B43 IN REGULAR WEIGHT. <br />B. CAST BRONZE THREADED FITTINGS: ANSI B16.15, CLASS 150, OR 250, AS <br />REQUIRED. <br />C. CAST BRONZE THREADLESS FITTINGS: ASTM B61, <br />17. CAST IRON SOIL PIPE <br />A. HUBLESS CAST IRON SOIL PIPE: ASTM A-888 (ABOVE GRADE). <br />B. CAST IRON HUB AND SPIGOT SOIL PIPE: ASTM A74, SERVICE WEIGHT. <br />C. HUBLESS CAST IRON SOIL PIPE FITTINGS: NEOPRENE GASKET COMPLYING <br />WITH ASTM C564 AND STAINLESS STEEL CLAMP HOLDING BAND (ABOVE <br />GRADE). <br />D. CAST IRON HUB AND SPIGOT SOIL PIPE FITTINGS: MATCH SOIL PIPE UNITS, <br />COMPLY WITH SAME STANDARDS (ASTM A74). <br />E. COMPRESSION GASKETS: ASTM C564. <br />18. PLASTIC PIPES AND PIPE FITTINGS <br />A. POLYVINYL CHLORIDE PIPE (PVC): ASTM D1785, IN SCHEDULE WEIGHT, AS <br />INDICATED ON DRAWINGS. <br />B. POLYVINYL CHLORIDE WATER PIPE (PVC): AWWA C900 IN <br />C. POLYVINYL CHLORIDE SEWER PIPE (PVC): ASTM D2729. <br />D. POLYVINYL CHLORIDE DRAIN, WASTE, AND VENT PIPE (PVC-DWV): ASTM <br />D2665. <br />E. POLYVINYL CHLORIDE TYPE PSM SEWER PIPE: ASTM D3034. <br />F. PVC FITTINGS <br />1. SCHEDULE 40 SOCKET: ASTM D2466 <br />2. SCHEDULE 80 SOCKET: ASTM D2467 <br />3. SCHEDULE 80 THREADED: ASTM D2464 <br />4. DWV SOCKET: ASTM D2665 <br />5. SEWER SOCKET: ASTM D2729 <br />6. SOLVENT CEMENT: ASTM D2564 <br />7. SOLVENT CEMENT (TO JOIN PVC TO ABS): ASTM D3138 <br />19. GENERAL CONTRACTOR WILL PROVIDE OPENINGS IN ROOF, FLOORS, AND <br />EXTERIOR WALLS FOR PLUMBING EQUIPMENT AND PIPE PENETRATIONS. <br />20. INSULATE ALL COLD WATER AND HOT WATER PIPING ABOVE FLOOR SLAB WITH <br />THREE QUARTER INCH (3/4") THICK FIBERGLASS INSULATION WITH VAPOR BARRIER <br />AND ALL SERVICE JACKET. SEAL ALL JOINTS WITH SEALING LAP. <br />21. PLUMBING FIXTURES AND SUPPORTS <br />A. FURNISH PLUMBING FIXTURES AS INDICATED BY PLANS AND SCHEDULES ON <br />THE DRAWINGS, AND AS SPECIFIED HEREIN, WITH ALL HOT AND COLD WATER <br />SUPPLIES, WASTE AND VENT CONNECTIONS, ALL FITTINGS, SUPPORTS, <br />FAUCETS, VALVES, AND TRAPS AS REQUIRED. <br />B. FURNISH ALL EXPOSED METAL WORK ON OR AROUND FIXTURES WITH BEST <br />QUALITY CHROME PLATED BRASS, UNLESS SPECIFIED OTHERWISE. <br />C. FURNISH ALL SUPPLIES TO FIXTURES WITH ANGLE STOPS. FURNISH SPS <br />BRASS NIPPLES FROM WALL TO STOPS. <br />D. FURNISH TRAPS FOR ALL FIXTURES EXCEPT THOSE WITH INTEGRAL TRAPS. <br />E. PLUMBING FIXTURES AS MANUFACTURED BY THE KOHLER COMPANY ARE <br />SPECIFIED, BUT ELJER, CRANE, OR AMERICAN-STANDARD MAY BE USED IF <br />THEY ARE CONSIDERED BY THE DESIGN PROFESSIONAL TO BE EQUIVALENT <br />TO THOSE SPECIFIED. <br />22. MEET LANDLORD'S TENANT CRITERIA WITH REGARD TO CONSTRUCTION FEATURES <br />AND SPECIAL REQUIREMENTS, ETC. VERIFY WHEN AND HOW WORK MAY BE <br />PERFORMED IN OTHER SPACES, WHERE REQUIRED. <br />23. EXISTING PIPING SHOWN ON THE DRAWINGS HAS BEEN LOCATED FROM <br />INFORMATION PROVIDED BY OTHERS. FIELD VERIFY EXACT LOCATIONS AND <br />COORDINATE WITH LANDLORD'S FIELD REPRESENTATIVE. <br />24. COMPLY WITH LOCAL HEALTH DEPARTMENT REGULATIONS. SEAL ALL PIPES <br />NEATLY WITH GROUT AT WALL, FLOOR, OR CEILING PENETRATIONS. OMIT <br />INSULATION ON EXPOSED PIPING BEHIND AND UNDER EQUIPMENT. PROVIDE <br />CLEARANCE FOR CLEANING BEHIND AND UNDER EXPOSED PIPING AS REQUIRED <br />BY HEALTH DEPARTMENT. WHERE POSSIBLE, INSTALL ALL PIPING CONCEALED. <br />CONFORM TO HEALTH DEPARTMENT REQUIREMENTS FOR FLOOR SINKS. <br />25. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR <br />REQUIRED BY CODE. <br />26. ALL DRAIN, WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF <br />EQUIPMENT & SECURED IN PLACE. <br />32. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR <br />APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED. <br />33. PLUMBING CONTRACTOR TO PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN <br />THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF EQUIPMENT, FOR EACH <br />APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY <br />CODE AND RESTRAINING DEVICE FURNISHED BY OWNER. PLUMBING <br />CONTRACTOR TO PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF <br />EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 12"/wc IS USED <br />DOWNSTREAM FROM THE GAS METER / REGULATOR. <br />34. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE <br />INDICATED ON DRAWINGS. <br />35. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ADDITIONAL WORK TO BE <br />FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. ALL ROUGH -IN <br />PLUMBING AND FINAL CONNECTIONS TO KITCHEN EQUIPMENT SHALL BE MADE BY <br />THE PLUMBING CONTRACTOR. <br />36. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING <br />REQUIREMENTS. <br />37. ALL GAS LINES SHALL BE SUPPORTED IN ACCORDANCE WITH ZONE 3 SEISMIC <br />BRACING REQUIREMENTS. <br />38. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED <br />FLUSH TO FLOOR SURFACE. <br />39. WATER HAMMER ARRESTOR SHALL BE INSTALLED AT ALL WATER LINES, PER <br />LOCAL CODE REQUIREMENTS. <br />40. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. THE AIR GAP <br />SHALL BE A MINIMUM 2 TIMES THE DIAMETER OF THE INDIRECT DRAIN. <br />41. PRIOR TO COMMENCING WORK ON THIS PROJECT, PLUMBING CONTRACTOR <br />SHALL VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES <br />IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH <br />WOULD CAUSE THE DESIGN TO BE ALTERED, PLUMBING CONTRACTOR SHALL <br />NOTIFY OWNER IMMEDIATELY. <br />42. PLUMBING CONTRACTOR SHALL INSTALL ALL BACKFLOW PROTECTION DEVICES <br />REQUIRED BY AGENCIES HAVING JURISDICTION. BACKFLOW DEVICES REQUIRING <br />TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0" A.F.F. <br />43. PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAIN FROM HEATING & <br />COOLING UNITS TO APPROVED DRAIN, GAS PIPING TO UNITS AND ALL FINAL <br />CONNECTIONS REQUIRED FOR OPERATION. <br />44. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR <br />THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE PLUMBING <br />CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR <br />TO CONSTRUCTION. FAILURE TO VERIFY THESE DIMENSIONS SHALL PLACE THE <br />RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE <br />PLUMBING CONTRACTOR. <br />45. PLUMBING CONTRACTOR TO PROVIDE LAVATORY CARRIER WITH CONCEALED ARM <br />SUPPORTS, HEAVY DUTY ROUND STEEL PIPE UPRIGHTS AND WELDED FEET. <br />6 <br />z <br />O <br />w <br />w <br />FU.I <br />co <br />0 <br />Lu <br />O <br />z <br />Lu <br />Lacc=i <br />a <br />0013 <br />to J <br />m U. <br />J <br />J " <br />F Q co <br />C� J <br />= LM 3: <br />ham <br />Lo >- <br />1 <br />Lri a <br />� W <br />a ta'o N <br />VN <br />�J <br />10 <br />a <br />Lo <br />a��`2 <br />N <br />0 <br />'� <br />N <br />E <br />Q <br />N <br />M <br />O <br />(45 <br />rn <br />LL <br />o_ <br />O <br />Z <br />wC)Q <br />J <br />N <br />N <br />� <br />M <br />o. <br />Z <br />14 O^ <br />V00 <br />```�pW1Wupig1i <br />A . N i <br />o \CENS o S0 i <br />o°o No. 65765 % <br />°o * o° <br />��O STATE OF ° �- <br />i <br />�J o°o o° 1,j <br />Z <br />� O o = .tom o c <br />°q�_� Q R 1 .�. <br />SHEET NUMBER <br />Pi <br />MATERIAL SCHEDULEJ Nrs 1 3 1 SYMBOLSLEGENDI Nrs 121 GENERAL NOTES1 NTs 1 1 <br />