Laserfiche WebLink
BUILDING SIGNS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />3'x23' BOX <br />380 LBS. <br />(1) 15 A <br />2.5 <br />115 <br />3'-9"x26' BOX <br />441 LBS. <br />(1) 15 A <br />5 <br />1'15 <br />4'-6"x33'-3" BOX <br />750 LBS. <br />(1) 15 A <br />8.4 <br />115 <br />5'x40' BOX <br />1220 LBS. <br />(1) 15 A <br />10 <br />115 <br />BUILDING LETTERS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />18" <br />215 LBS. <br />(2) 15 A <br />19.6 <br />115 <br />24" <br />288 LBS. <br />(1) 15 A & (1) 20 A <br />23.45 <br />115 <br />30" <br />387 LBS. <br />(2) 20 A <br />28 <br />115 <br />36" <br />649 LBS. <br />(2) 15 A & (1) 20 A <br />32.9 <br />115 <br />REQUIRED NATIONAL ACCOUNT VENDORS <br />COMPANY <br />NATIONAL CONTACT <br />PHONE # / EMAIL <br />BUILDING SIGNS, BUILDING LETTERS, PYLON SIGNS <br />DUALITE SALES <br />ROSE SHINKLE <br />513-724-7100 <br />(AR, IA, IL, IN, KY, KS, LA, MI, MN, MO, MS, OH, <br />& SERVICE <br />(SR. PROJECT MANAGER) <br />rshinkle@dualite.com <br />OK, TN,TX,WI) <br />SIGN RESOURCE <br />IDENTITY GROUP <br />ANGII HEIDBRINK <br />323-485-4720 <br />(AZ, CA, CO, NE, NM,NV, SD, UT, WY) <br />EVERBRITE <br />CHRISTiNE OLSON <br />414-427-2329 <br />(AL, CT, DE, FL, GA, MA, MD, ME, NC, NH, NJ, <br />NY, PA, RI, SC, VA, VT, WV) <br />NATIONAL ACCOUNT & CONTACT INFORMATION SUBJECT TO CHANGE <br />LINE #1 WILL HAVE TWO RJ-11 JACKS. ONE <br />AT REGISTER, SECOND IN THE OFFICE. LABEL <br />AS PHONE. ALL PHONE JACKS REQUIRE A <br />BLUE <br />SEPARATE 24 ga. CAT 5,4 PAIR HOME RUN TO <br />& <br />DMARC. NOTE SEPARATE GROUND WIRES. REFER <br />BLUE/WHITE <br />TO SHEET E-3 FOR DETAILS,,, <br />LEGEND <br />(n <br />BUZZER - TORK MODEL #TA725 W/ TRANSFORMER MODEL <br />#TA592. <br />QQ <br />COMMERCIAL GRADE PUSH BUTTON <br />125V NEMA 5-20R DUPLEX <br />125/250V NEMA L14-20-R 4 PRONG TWIST LOCK <br />125V NEMA 5-20R QUAD <br />`EI <br />DISCONNECT <br />POWER POLE - BLACK MAGIC <br />PHONE JACK @ REGISTER <br />VOICE/DATA PORT = 'RJ-11, RJL45 DATA JACK, PHONE <br />COMBO @ OFFICE <br />$M <br />PROVIDE OCCUPANCY LIGHT SENSOR - LEVITON ODS 10-IDW <br />20 AMP TOGGLE SWITCH <br />NL <br />NIGHT LIGHT CIRCUIT <br />ELECTRICAL SPECIFICATIONS: <br />1. ALL EXPOSED WIRING SHALL BE CONTAINED IN CONDUIT OF PROPER <br />SIZE. <br />2. ALL WIRING SHALL CONFORM TO LOCAL, STATE, AND FEDERAL CODES. <br />3. ELECTRICAL SERVICE TO BE MINdMUM 400 AMP, 3-PHASE (PREFERRED) <br />OR 600 AMP, SINGLE PHASE OR LARGER IF REQUIRED BY CODE OR <br />ELECTRICAL LOAD. <br />4. REGISTER POWER POLES - VERIFY REGISTER CONFIGURATION ON FINAL <br />FIXTURE PLAN BEFORE ORDERING AND INSTALLATION OF ELECTRICAL <br />COMPONENTS. CUSTOM BUILT POWER POLE ASSEMBLY AVAILABLE <br />FROM D&P CUSTOM LIGHTS & PRODUCTS INC. PHONE # (800) 251-2200 <br />OR (615) 350-7800, 7111 COCKRILL BEND INDUSTRIAL ROAD. NASHVILLE, <br />TN 37209 <br />5. EXTERIOR EXPOSEDPHONE LINES TO BE INSTALLED IN RIGID CONDUIT. <br />PROVIDE EMERSON 3/4" x 5-FT. METALLIC CABLE U-GUARD #755 OR <br />EQUAL. <br />6. ELECTRIC PANELS TO BE LABELED CORRECTLY WITH LEGIBLE PRINT. <br />7. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA., 4 <br />TWISTED -PAIR, CATEGORY -FIVE (CAT5) DATA CABLE WITH MODULAR <br />COMBO RJ-11/RJ/45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN <br />FROM JACK TO DATA HUB LOCATION WITH 6'-0" LEFT COILED FOR <br />INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED <br />ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE <br />FINAL CONNECTION INTO THE DATA HUB. <br />8. SEE SHEET F1 FOR COOLER/FREEZER OPTIONS. VERIFY FINAL LOCATION <br />AND NUMBER OF COOLERS AND FREEZERS ON FINAL FIXTURE PLAN <br />BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS. <br />EACH COOLER REQUIRES A 20 AMP DEDICATED GROUND CIRCUIT TO BE <br />USED FOR A 110v OUTLET. EACH OF THESE UNITS DRAW 12 AMPS. EACH <br />FREEZER REQUIRES ONE - 125/250V OUTLET NEMA #1_14-20 w/ 4 PRONG <br />TWIST LOCK. EACH UNIT DRAWS 16 AMPS. TWO DOOR FREEZER IN <br />RECEIVING AREA REQUIRES ONE 125/250V NEMA 14-20R OUTLET ON A 20 <br />AMP DEDICATED CIRCUIT. UNIT DRAWS 8 AMPS. <br />PYLON SIGNS <br />SIGN SIZE <br />SIGN WT. <br /># OF CKTS. <br />AMPS <br />VOLTS <br />4W' <br />188 LBS. <br />(1) 15 A <br />1.7 <br />115 <br />5'x10' <br />375 LBS. <br />(1) 15 A <br />3.4 <br />115 <br />6'x16' <br />738 LBS. <br />(1) 15 A <br />5 <br />115 <br />NOTES: <br />1. PROVIDE AND INSTALL CONDUIT, JUNCTION BOXES, D&P CONNECTORS <br />AND/OR POWER POLE(S) FOR CASH REGISTER(S), VERIFY LOCATION OF <br />JUNCTION BOXES WITH <br />TENANT'S FIXTURE FLOOR PLAN PROVIDED BEFORE TURNOVER DATE. <br />2. PROVIDE AND INSTALL POWER POLE(S) FOR REGISTERS AND ICE CREAM <br />FREEZER. <br />3. PROVIDE AND INSTALL POWER POLES FOR REFRIGERATION UNITS. <br />4. VERIFY LOCATION OF POWER POLES WITH TENANT'S FIXTURE FLOOR <br />PLAN PROVIDED BEFORE TURNOVER DATE. <br />5. PROVIDE AND INSTALL ELECTRICAL RECEPTACLES. <br />6. PROVIDE AND INSTALL BREAKER LOCKS ON THE FOLLOWING: <br />REGISTER POWER POLES, SALES FLOOR COOLERS AND FREEZERS, <br />RECEIVING/SALES NIGHT LIGHTS, SECURITY OUTLETS, OUTDOOR ICE <br />MERCHANDISER, AUTOMATIC DOORS, TELEPHONE BOARD, DOOR <br />BUZZER, OFFICE RECEPTACLES, OFFICE LIGHTS, BREAK ROOM, <br />RESTROOMS AS SHOWN ON PANEL LAYOUT, <br />7. FULLY LABEL ALL PANEL SCHEDULES ACCURATELY AND LEGIBLY. <br />HAND WRITTEN LABELS NOT ACCEPTABLE <br />&PROVIDE AND INSTALL CONDUIT FROM PANEL TO NEW BUILDING SIGN <br />LOCATION, TERMINATING IN A JUNCTION BOX TO BE CENTERED <br />HORIZONTALLY ON TENANTS PROPOSED SPACE AND VERTICALLY ON <br />THE CANOPY. <br />PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT <br />90" AFF WITH 3 #10 CU. & #10 GROUND IN 4'C. R.C. <br />TO PROVIDE AND INSTALL 30A/2NF DISCONNECT <br />SWITCH AND WIRE FROM DISCONNECT SWITCH TO <br />� DAI <br />1 I EQUIPMENT CONNECTIONS. <br />°`« <br />A-29 - — <br />m <br />(E) RTU-1 <br />A-22. <br />`PROVIDE NON FUSED <br />R-21,23 DISCONNECT AT W.H. <br />FIELD LOCATE BUZZER. <br />PROVIDE 2 NO 12 AWG CU AND <br />I NO 12 AWG CU EQ GND IN 1/2" E <br />C. TO BUZZER PUSHBUTTON AT <br />Hummm0mgm RECEIVI <br />-- UNDERGROUND SERVICE <br />LATERAL. SEE POWER <br />DISTRIBUTION RISER <br />DIAGRAM FOR ADDITIONAL <br />INFORMATION. <br />A-8 <br />A-7,9,11 <br />TE _EPHO E CONDUIT <br />ST JB THROUGH WALL. <br />1 RTU-2 <br />EXISTING PULLBOX <br />EXISTING CT CABINET <br />PANEL "R" <br />PANEL "B" <br />0 <br />0 <br />0 <br />DUPLEX OUTLET <br />DEDICATED CKT R-39 <br />PANEL "A" <br />R-2,4 <br />PANEL EMS,HVAC & LTG <br />PANEL HVAC CONTROL mm <br />KNOX BOX FOR <br />FIRE DEPT ACCESS <br />BUZZER PUSH BUTTON <br />60 AMP., 240VAC, 3 WIRE <br />(3 BLADES) SAFETY <br />SWITCH IN A NEMA 3R <br />ENCLOSURE. 3 NO 8 <br />AWG THWN CU AND 1 RTU-3 <br />NO 10 AWG THWN CU <br />EQUIPMENT GROUND IN <br />3/4" CONDUIT. AVOID <br />ROUTING CONDUIT <br />ABOVE ROOF TO THE i <br />GREATEST EXTENT A-13,15,17 <br />PRACTICABLE. <br />E <br />125V NEMA 5-20R DUPLEX <br />R-14,16 <br />R-6,8 R-10,12 <br />WEATHERPROOF GFCI RECEPTACLE WITH IN -USE COVER <br />(TYPICAL OF 5) USE 2 NO 12 AWG THWN CU AND 1 NO 12 <br />AWG THWN CU EQUIPMENT GROUND IN 3/4" CONDUIT. <br />AVOID ROUTING CONDUIT ABOVE ROOF TO THE <br />GREATEST EXTENT PRACTICABLE. <br />9. PROVIDE AND INSTALL A TIMER AND PHOTOCELL COMBINATION. ROUTE THE <br />FOLLOWING CIRCUITS THROUGH <br />THE TIMER/PHOTECELL ASSEMBLY: <br />PYLON SIGN, BUILDING SIGN, PARKING LOT LIGHTS, WALL PACKS, AND <br />CANOPY LIGHTS <br />10. PROVIDE AND INSTALL 1" CONDUIT WITH PULL STRING ABOVE THE <br />MANAGER'S OFFICE WITH ROOF OR WALL PENETRATION FOR VSAT <br />(TENANT SATELLITE). COORDINATE EXACT LOCATION WITH TENANT <br />CONSTRUCTION DEPARTMENT PROJECT MANAGER. <br />11. PROVIDE AND INSTALL CONDUIT WITH PULL STRINGS AT MANAGER'S <br />OFFICE, CASH, REGISTER AREA AND DMARC PANEL. COORDINATE <br />EXACT LOCATION WITH TENANT CONSTRUCTION DEPARTMENT <br />PROJECT MANAGER, <br />12. PROVIDE 1" CONDUIT FROM OFFICE TO CENTER OF SALES AREA <br />TERMINATING WITH A JUNCTION BOX. HOLD CONDUIT TIGHT TO <br />STRUCTURE. WAP MOUNTED AT 12'-0" AFF, <br />13. PROVIDE AND INSTALL CONDUIT FROM PANEL, THROUGH BUILDING, AND <br />UNDERGROUND TO PYLON SIGN LOCATION. STUB UP CONDUIT 12" ABOVE <br />GRADE AT PYLON LOCATION, CAP AND MARK WITH 36" HIGH STAKE. <br />14. LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, <br />CATEGORY -FIVE (CATS) DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 <br />JACK AT MANAGER'S OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB <br />LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA <br />HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END, DOLLAR <br />GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE <br />DATA HUB, <br />R-1,3 <br />R-5,7 <br />PROVIDE 208V, 1 PHASE CONNECTIO T A J-BO AT <br />90" AFF WITH 3 #12 CU. & #12 GROUN IN 4'C. R C. <br />TO PROVIDE AND INSTALL 30A/2NF D ONNE <br />SWITCH AND WIRE FROM DISCONNE SWITCH TO <br />EQUIPMENT CONNECTIONS._„ <br />`'1'.'�:'.`.\:.�\'.\". \ `�'�''C[��''\i'l �\.F�.`c`. '�'.ci`'cC :\ `='F''i-\'�:`u`,F<'[?`...'«'e'.�'r `ram. .._....., � �.-:-�•..,, �> -'• -h -_--._.�.___...__.__...--- --_.�.__-. _'-__ _ -�- <br />J <br />PROVIDE 208V, 1 PHASE CONNECTION T A J-BOX AT R-9,11 1 <br />90" AFF WITH 3 #8 CU. & #10 GROUND IN 1"C. R.C. RA3,15 R-17,19 <br />TO PROVIDE AND INSTALL 60A/2NF DISCONNECT <br />SWITCH AND WIRE FROM DISCONNECT SWITCH TO f <br />EQUIPMENT CONNECTIONS. <br />A-41 SO CORD (WHITE), WITH <br />COORDINATE EXACT <br />QUAD RECEPTACLE. <br />ANCHOR TO PURLINS POWER REQUIREMENTS <br />ABOVE (TYPICAL, 5). WITH SIGN VENDOR. <br />REFER TO CHARTS <br />SHOWN ON THIS SHEET. <br />DUPLEX RECEPTACLE FOR <br />A-37 GATORADE COOLERS. GFI RECPT. FOR ICE <br />A-18 MERCH @ 4 -0"" A.F.F. <br />A-26 A-24 <br />A-20 ! <br />B-23 i <br />GFI RECPT. FOR SODA <br />f� MERCH. @ 4'-0" A.F.F. <br />CIRCUITS ROUTED DOWN 14'-0" POWER A-2,4,6 <br />POLE TO EQUIPMENT. PROVIDE AND HEAVY DUTY, 12"X 20" <br />(E) RTU-4 INSTALL RECEPTACLES (NEMA 5-20R) FOR RTU-5 SHELF (BY G FOR <br />COOLERS, AND REGISTERS. SEE FIXTURE VSAT & DA HUB <br />PLAN SHEET (F1) EQUI II ENT. <br />REGISTE <br />TO DMAR <br />POWER A-10,12, TO REGISTE <br />B-30, 32, 34, 36, 38,40,42,44 . �_ <br />DED. QUAD. RECPT. @ 3'-0" <br />#P3AC24-16-8L, 16 CAMERA, 24 VAC, <br />8 AMP, POWER SUPPLY CABINET. ----� <br />L- FOR RTU-3 AND 5: - <br />DED. QUAD. RECPT. @ <br />B 8 <br />125/250V NEMA L 14-20-R 100�AMP., 240VAC, 3 WIRE (3 BLADES) SAFETY SWITCH IN A NEMA 3R ENCLOSURE. 3 NO 3 3'-0" FOR CCTV EQUIP. <br />AWG THWN CU AND 1 NO 8 AWG THWN CU EQUIPMENT GROUND IN 1-1/4" CONDUIT. AVOID A-27 #BW-106 VIDEO <br />4 PRONG TWIST LOCK ROUTING CONDUIT ABOVE ROOF TO THE GREATEST EXTENT PRACTICABLE. IT IS \1 CONVERTER ENCLOSURE. <br />PREFERRED TO BE ROUTED BELOW ROOF. <br />LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL 24 GA., 4 TWISTED -PAIR, CATEGORY -FIVE (CAT5) <br />DATA CABLE WITH MODULAR COMBO RJ-11/ RJ-45 JACK AT MANAGER'S OFFICE. CABLE TO BE RUN <br />FROM JACK TO DATA HUB LOCATION WITH 6' LEFT COILED ABOVE CEILING FOR INSTALLATION TO <br />DATA HUB. AN RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE <br />OPENING TEAM WILL MAKE FINAL CONNECTION INTO THE DATA HUB. PROVIDE DATA CABLE TO <br />*NOTE: BEFORE ORDERING AND INSTALLATION <br />OF ELECTRICAL COMPONENTS FOR COOLERS, <br />FREEZERS, AND REGISTERS, CONSULT FINAL <br />FIXTURE PLAN FOR NUMBER AND LOCATION. IF <br />CEILING HEIGHT IS ABOVE 10', COMMUNICATE <br />WITH D&P WHEN ORDERING FOR PROPER <br />POWER POLE HEIGHT. <br />MAXIMUM NUMBER OF CIRCUITS FOR <br />COOLERS/FREEZERS IN SALES AREA - (5) 110v <br />AND (3) 220v MAXIMUM CIRCUITS FOR <br />REGISTE§RS - CIRCUITS AT MAIN REGISTER - (8) <br />110v CIRCUITS AT ISLAND REGISTER - (3) 110v <br />FLOOR PLAN - <br />POWER & DATA <br />NOT roSCALE <br />EACH REGISTER AND ALL DEVICES REQUIRING DATA. ROUTE CABLES TO DATA HUB. <br />*NOTE: <br />VERIFY FINAL LOCATION OF ALL ELECTRICAL WITH THE FINAL <br />FIXTURE LAYOUT PLAN PROVIDED BY STORE PLANNING. <br />A-35 <br />B-4- <br />QUAD RECEPTACLE FOR <br />COSMETICS VALANCE. <br />z j <br />x <br />�O <br />0° I <br />w Z I <br />A 39 Q <br />z z B-23 <br />v5 i <br />O <br />H <br />VOICE/DATA/VSAT <br />CONDUITS. <br />z <br />0 <br />DED. QUAD. RECPT. <br />@ 6'-0" FOR VSAT, <br />DATA HUB EQUIP. <br />INTERFACE EQUIPMENT REQUIRES <br />\48" WIDE CLEAR WALL SPACE. <br />INTERFACE ALARM PANEL <br />SECURITY RECPT. @ T-0" A.F.F. <br />FIRE ALARM EQUIP. PANEL <br />RECEPT. @ l'-6" A.F.F. <br />lid <br />H <br />r� <br />V <br />Z W d- <br />A p <br />oLn <br />a C110�co <br />w � � cn00 <br />Fz�-Q� <br />LI <br />�xUcC=cn <br />—'zgco <br />��� <br />ON <br />LL <br />a <br />o <br />U O <br />U <br />� <br />co co <br />CUr <br />J N <br />cn <br />Co t- <br />J CO ,It <br />t <br />o w <br />L CO d <br />LN <br />O <br />O <br />_O <br />� <br />co O <br />Qcco <br />0 o <br />0- co <br />ro�.a) <br />w <br />o U) <br />c000 <br />E <br />6z <br />WU)NN"Q <br />UM <br />�_ <br />U) <br />aIU) <br />o <br />of ° <br />U- <br />1� o <br />C � <br />r44 <br />4 <br />0) m <br />N a_ <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />CONTRACT DATE: 08.01.2018 <br />BUILDING TYPE: N/A <br />PLAN VERSION: N/A <br />SITE NUMBER: N/A <br />STORE NUMBER: N/A <br />TENANT FINISH <br />GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />FINISH PLAN <br />PHASE 2 <br />FLOOR PLAN - <br />POWER & DATA <br />E1 <br />PLOT DATE: <br />