PLUMBING SPECIFICATIONS: <br />PLUMBING FIXTURE AND CONNECTION SCHEDULE 1. GENERAL 12, VALVES & ACCESSORIES <br />A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM AS A. PROVIDE WATER HAMMER ARRESTORS OR AIR CHAMBERS AS REQUIRED TO ELIMINATE WATER <br />GENERAL CONNECTIONS NOTES OUTUNED IN THE CONTRACT DRAWINGS AND THESE SPECIFICATIONS. HAMMER AND COMPLY WITH LOCAL REGULATIONS, PARTICULARLY AT ALL APPLIANCES OR DEVICES <br />TAG DESCRIPTION MTG. HEIGHT WASTE VENT CW HW B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW THE GENERAL WITH QUICK -CLOSING VALVES. <br />ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL B. PROVIDE A MAIN SHUTOFF VALVE AT THE BUILDING'S DOMESTIC WATER SERVICE ENTRANCE. <br />P-1 SINGLE COMPARTMENT COUNTERTOP 1 1/2" 1 1/2" 1/2" 1/2" WHITE VITREOUS CHINA COUNTERTOP LAVATORY W/ 4" CENTER FAUCET C. DO NOT SCALE PLANS. C. PROVIDE VACUUM BREAKERS FOR ALL SILLCOCKS. HOSE BIBBS, AND WALL HYDRANTS. <br />SINK FLOOR TO RIM HOLES. 0.5 GPM VANDAL RESISTANT FAUCET W/ EXTRA LONG LEVEL, D. PROVIDE ALL NECESSARY FITTINGS, TRANSITITONS, CONNECTORS, ETC. WHETHER SHOWN OR D. PROVIDE CLEANOUTS AT ALL CHANGES OF DIRECTION OF MORE THAN 45 DEGREES OR EVERY <br />NOT ON PLANS. 50 FEET OF STRAIGHT PIPE FOR ALL SANITARY WASTE AND STORM DRAIN PIPING. PROVIDE <br />31 " MAX HOT LIMIT STOP, GRID DRAIN. 1 J" 17 GA. TRAP W/ CLEANOUT. E. ALL WORK IS NEW UNLESS OTHERWISE NOTED. CLEANOUTS AT THE BASE OF ALL STACKS. PROVIDE A YARD CLEANOUT FLUSH WITH FINISHED <br />F. THESE PLANS REPRESENT THE DESIGN INTENT BASED ON INFORMATION AVAILABLE AT THE GRADE WITHIN 5 FEET OF THE BUILDING SEWER EXITING THE BUILDING. COORDINATE ALL <br />TIME OF DESIGN. ANY O INSTALLATION. <br />P-2 PEDICURE CHAIR NA 1 1 /2" NA 1 /2" 1 /2p LEXOR PIONEERING "SMART" PEDI-SPA. SEE ATTACHED SPEC SHEET. CONSTRUCTION PHASE SHALL B REPODRTED TO THE ENGINEER PRIOR IFICATIONS OR ALTERATIONS �TO WORK. MODIFICATIONS EDURING THE L PROVIDE EANOUT L DIELECTRIC UNIONS TIONS WITH THE AT CALL POINTS OFHITECT PRIOR TCONNECTION BETWEEN PIPES OF DISSIMILAR <br />MADE WITHOUT THE ENGINEER'S WRITTEN APPROVAL SHALL REMAIN THE RESPONSIBILITY OF THE METALS. <br />CONTRACTOR. F. APPLY MIN. 20 MILS THICK SCOTCHWRAP (OR EQUIVALENT) VINYL TAPE COVERING OVER ALL <br />P-3 LAVATORY FLOOR TO RIM 1 1 /2" 1 1 /2" 3/8" 3/8" PROFLO 5514WH WALL HUNG LAVATORY WITH PROFLO WS4744CP SINGLE G. IN CASE OF ANY DISCREPANCIES BETWEEN THE DRAWINGS, SPECIFICATIONS, FIELD STEEL OR COPPER WATER PIPING IN CONTACT WITH MASONRY OR CONCRETE. <br />(ADA) WALL HUNG 34" MAX LEVER FAUCET. PVD SLIP -JOINT P-TRAP. CR1912CP ANGLE STOP AND CONDITIONS, CODES, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFER ALL SUCH G. PROVIDE CHROME PLATED ESCUTCHEONS WHERE PIPES PENETRATE ANY EXPOSED WALLS, <br />PEX SUPPLIES MATTERS TO THE ENGINEER IN WRITING IMMEDIATELY FOR RESOLUTION PRIOR TO EXECUTING ANY PARTITIONS, ETC. TO COVER THE PENETRATION. <br />WORK. ANY WORK PERFORMED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER SHALL <br />REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. 13. FIXTURES <br />P-4 WATER CLOSET-H/C FLOOR TO RIM 3" 2" 3/8" --- PROFLO MODEL 1403JWH ADA ELONGATED BOWL W/ PROFLO PF5112WHM H. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) AS WELL AS ALL A. FIXTURES HAVE BEEN SELECTED TO ESTABLISH A STANDARD OF QUALITY AND SUBSTITUTIONS <br />(ADA) FLOOR MOUNTED 2 17" 1.6 GPF TANK IN WHITE. PROFLO TSCOF200WH ELONGATED BOWL WHITE LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS: ARE NOT PERMITTED UNLESS SUBMITTED AND APPROVED PRIOR TO USE. <br />PIECE FLUSH TANK OPEN FRONT LESS COVER SEAT. 2006 INTERNATIONAL PLUMBING CODE B. ALL VITREOUS CHINA FIXTURES SHALL BE WHITE UNLESS OTHERWISE NOTED. <br />2006 INTERNATIONAL BUILDING CODE C. SEE ARCHITECHTURAL PLANS FOR EXACT FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />2003 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ANSI IIICC A117.1) D. ALL FIXTURES IN THE SAME BUILDING OR AREA SHALL HAVE IDENTICAL FAUCETS, <br />WH-1 ELECTRIC WATER FLOOR MOUNTED - - - 3/4" SEE DWGS SEE DWGS (2) A.O. SMITH ELECTRIC 40 GALLON WATER HEATER W SIAMESE CONNECTION CITY OF CHATTANOOGA LOCAL. AMENDMENTS & ORDINANCES (AS APPLICABLE) ESCUTCHEONS, AND TRIM KITS, UNLESS SPECIFICALLY NOTED ON PLANS. <br />/ E. INSTALL HOT WATER SUPPLY ON THE LEFT SIDE OF ALL FIXTURES. <br />HEATER T & P 2. SCOPE OF WORK F. ALL LAVATORIES IN PUBLIC RESTROOMS SHALL HAVE 0.5 GPM FLOW RESTRICTING AERATORS. <br />PROVIDE NEW FIXTURES AND PIPING AS SHOWN AND CONNECT TO EXISTING PLUMBING MAINS. G. FLUSH CONTROLS SHALL BE INSTALLED ON THE WIDE SIDE OF ALL WATER CLOSET STALLS. <br />H. PROVIDE CONCEALED ARM CARRIERS OR 200 PT BLOCKING WITH ALL WALL MOUNTED <br />3. ITEMS FURNISHED BY CONTRACTOR LAVATORIES, URINALS, WATER CLOSETS, AND WATER COOLERS. CARRIERS OR BLOCKING SHALL <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, EQUIPMENT, WITHSTAND A MINIMUM VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE FIXTURE. <br />CWM CLOTHES WASHER 48" A.F.F. 2" 2" 1/2" 1/2" CLOTHES WASHER PROVIDED BY OTHERS. ENCASED WASHING MACHINE VALVES W/ AND ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL BE J. PROVIDE PROTECTIVE ANTI -MICROBIAL INSULATION ON THE SUPPLY SET AND WASTE DRAIN <br />SINGLE LEVER HANDLEMOUNTING STRAPS, AND 2" WASTE TAILPIECEPROVIDE STORED IN A SAFE, DRY PLACE IN THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY AND TRAP OF ALL HANDICAPPED LAVATORIES. <br />, . <br />BOX FOR USE. THE OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE K. ALL WATER CLOSETS SHALL BE THE ELONGATED TYPE WITH OPEN FRONT SEATS. <br />INTEGRAL WATER HAMMER ARRESTORS. PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR <br />PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND ARRANGING FOR ALL INSPECTIONS, 14• SUPPORTS & PENETRATIONS <br />FD FLOOR DRAIN FLUSH W/ PROFLO PVC W/ 6" BRASS TOP INCLUDING COORDINATION WITH AND SATISFYING ALL REQUIREMENTS OF THE PLUMBING UTILITY A. PROVIDE MANUFACTURED PIPE HANGERS, RODS, AND INSERTS OR CLAMPS FOR THE PROPER <br />3" --- 1 /2" --- COMPANY(IES) AS MAY BE REQUIRED TO EXECUTE THIS SCOPE OF WORK. SUPPORT OF ALL PIPING. BAND IRON, TIE WIRE, OR WIRE STRAPPING ARE NOT ACCEPTABLE. <br />FINISHED FLOOR ALL PIPES SHALL BE SUPPORTED AT REGULAR INTERVALS. PIPE SWAY AND/OR VIBRATION SHALL <br />4. WORK IN EXISTING BUILDINGS NOT BE ACCEPTABLE. DO NOT HANG PIPING FROM ANYTHING OTHER THAN THE BUILDING <br />GRAVITY A. DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. STRUCTURE. <br />TP TRAP PRIMER UNDER -- B. ALL ITEMS REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE OWNER. B. SUPPORT ALL PIPING ACCORDING TO THE FOLLOWING SPACING CRITERIA: <br />LAVATORY 1 /2w - CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE PROJECT SITE. HORIZONWED VERTICAL (ED <br />C. SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR CLARITY OR REFERENCE CAST IRON 5 15 <br />ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK MAY ALSO BE PRESENT. COPPER 6 10 <br />WHA STAINLESS STEEL WATER HAMMER ARRESTOR WITH " I.P.S. THREADED PIPE CONNECTION D. DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS AND FIELD CPVC 3 10 <br />WATER HAMMER CONDITIONS SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO SUBMITTING A BID CONTRACTOR PVC 4 10 <br />ARRESTOR --- --- 3/4" --- AND TYPE 304 STAINLESS STEEL CASING AND BELLOWS. SHALL STUDY THE PLANS AND VISIT THE PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH STEEL 8 10 <br />EXISTING CONDITIONS. ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD C. PROVIDE PLASTIC OR RUBBER COATED ISOLATORS WHERE COPPER PIPING IS IN DIRECT <br />SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE REPORTED TO THE CONTACT WITH OR SUPPORTED BY STEEL PIPE HANGERS. <br />ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO WILL NOT BE SUFFICIENT CAUSE FOR <br />GENERAL NOTES DELAYS OR CHANGES LATER IN THE PROJECT. CHANGE ORDERS RESULTING FROM FAILURE TO 15, WARRANTIES AND MAINTENANCE <br />1. PROVIDE MCGUIRE PRO -WRAP INSULATION KIT FOR DRAIN, TRAP, & SUPPLY ON ALL ADA SINKS AND LAVATORIES. PROPERLY INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK IS NEW A. ALL FIXTURES SHALL BE TESTED, CLEANED, AND PLACED IN GOOD OPERATING CONDITION BY <br />UNLESS OTHERWISE NOTED. THE CONTRACTOR. CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND <br />2. ALL DRAIN AND VENT LINES TO BE PVC E. MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW WORK SHALL BE WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF <br />3. PROVIDE ALL BOLT CAPS, STRAINERS, STOPS, SUPPLIES, TRAPS, ETC. FOR A COMPLETE INSTALLATION. CONSIDERED TO BE PART OF THE BASIC WORK OF THIS CONTRACT. ACCEPTANCE BY THE OWNER AND THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO <br />4. PROVIDE DEEP SEAL TRAPS FOR ALL DRAINS AND FLOOR SINKS. F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE DISRUPTIONS TO EXISTING COST TO THE OWNER. ALL EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE <br />SYSTEMS OUTSIDE THIS SCOPE OF WORK. MANUFACTURER'S WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF ALL <br />MANUFACTURER'S WARRANTIES AND CONTRACTOR WARRANTIES SHALL BE PROVIDED TO THE <br />5. COORDINATION OWNER AT FINAL ACCEPTANCE. <br />PLUMBING SYSTEM DEMAND ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH THE OWNER AND ALL OTHER B. CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE AND REVIEW ALL OPERATIONS <br />TRADES PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. CONTRACTOR SHALL AND MAINTENANCE OF ALL SYSTEMS. CONTRACTOR SHALL PROVIDE THE OWNER WITH BOUND <br />FIXTURE QUANTITY DFU COLD HOT REVIEW PLANS OF ALL DISCIPLINES INVOLVED AND ADVISE THE ARCHITECT IN WRITING OF ANY COPIES OF ALL OPERATION AND MAINTENANCE MANUALS INCLUDING PARTS USTS, MAINTENANCE <br />CONFLICTS, CODE OR SAFETY ISSUES THAT MAY EXIST PRIOR TO ANY FABRICATION OR ORDERING SCHEDULES, ETC. <br />CLOTHES WASHER 1 2.0 1.0 1.00 OF EQUIPMENT. RESOLUTION OF SUCH CONFLICTS WHICH ARE NOT REPORTED PRIOR TO C. THE CONTRACTOR SHALL CONTINUALLY RECORD ANY AND ALL DEVIATIONS TO THE CONTRACT <br />CONSTRUCTION SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR AND CHANGE ORDER DOCUMENTS MADE DURING CONSTRUCTION AND PROVIDE A COMPLETE SET OF THESE RECORD <br />PEDICURE SINK 8 = 16.0 8.0 8.0 PROPOSALS FOR SUCH WORK WILL NOT BE ACCEPTED. PROVIDE ROUTING AND OFFSETS DRAWINGS TO THE OWNER WITHIN 30 DAYS OF COMPLETION OF CONSTRUCTION. IF REQUIRED BY <br />LAVATORY 3 = 3.0 4.5 4.5 NECESSARY TO AVOID CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. THE AUTHORITY HAVING JURISDICTION, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR <br />CONTRACTOR SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR FLOOR TO SECURE THE SERVICES OF A UCENSED PROFESSIONAL ENGINEER TO PROVIDE SIGNED AND <br />WATER CLOSET 1 = 4.0 5.0 PENETRATIONS. SEALED RECORD DRAWINGS. <br />S. PLUMBING GENERAL 16. TESTING <br />TOTAL FIXTURE UNITS 25.00 18.50 13.50 A. ALL PLUMBING SERVICES TERMINATE 5'-0" FROM THE BUILDING EXTERIOR WALLS. A. AT THE COMPLETION OF THE PROJECT, TEST ALL PLUMBING SYSTEMS AND FIXTURES FOR <br />B. NO LEAD OR ASBESTOS CONTAINING MATERIALS OF ANY KIND SHALL BE USED IN THE PROPER OPERATION. TEST ALL PIPING FOR LEAKS ACCORDING TO FPC. REPORT ALL RESULTS TO <br />FABRICATION OF POTABLE WATER SUPPLY SYSTEMS. GALVANIZED STEEL PIPING SHALL NOT BE THE ARCHITECT IN WRITING. REPLACE ANY DEFECTIVE DEVICES OR EQUIPMENT. <br />MINIMUM SANITARY DRAIN SIZE (INCHES) 4" USED FOR POTABLE WATER SUPPLY PIPING. <br />MINIMUM SERVICE FLOW (GPM) 12.00 10.00 C. INSTALL ALL WORK IN COMPLIANCE WITH ADA REQUIREMENTS. COLD WATER <br />MINIMUM WATER SERVICE SIZE (INCHES) 1" 1" D. PROVIDE "P" TRAPS WITH CLEANOUTS IN THE DRAINS OF ALL FIXTURES EXCEPT THOSE WITH <br />INTERNAL TRAPS OR AS SPECIFICALLY NOTED ON PLANS. <br />NOTES E. PROVIDE FLOOR DRAINS WITH TRAP PRIMERS IN ALL PUBUC BATHROOMS. <br />1. DRAINAGE FIXTURE UNITS DETERMINED FROM 2014 F. ALL PIPING SHALL BE CONCEALED IN WALLS, CHASES, CEILINGS, ETC. UNLESS SPECIFICALLY <br />NOTED ON DRAWINGS. ANY PIPING OR ACCESSORIES THAT MUST BE EXPOSED SHALL HAVE A <br />FLORIDA PLUMBING CODE, TABLE 709.1. POLISHED CHROME FINISH. <br />2. SUPPLY FIXTURE UNITS DETERMINED FROM 2014 G. INSTALL ALL VALVES AND CONTROLS IN ACCESSIBLE LOCATIONS, EXCEPT AS SPECIFICALLY <br />FLORIDA PLUMBING CODE, TABLE E103.3(2). NOTED ON PLANS OR PROHIBITED BY CODE. HOT WATER SUPPLY <br />3. SERVICE DEMAND GPM DETERMINED FROM 2014 H. PROVIDE MIN. 6x6 INCH PAINTED ALUMINUM ACCESS DOORS WITH FULL HINGE AND KEY, FOR TO FIXTURES <br />(GPM) ACCESS TO ALL VALVES, CONTROLS, AND ACCESSORIES CONCEALED IN PLASTER, TILE, DRYWALL, <br />OR INACCESSIBLE CEIUNGS OR IN WALLS. GROUP DEVICES AT A SIN TAP M TA E103.3(3). GLE LOCATION AS <br />FLORIDA PLUMBING CODE TABLE, <br />AVAIL <br />ABLE. <br />J. COORDINATE THE ELECTRICAL CHARACTERISTICS OF ALL ELECTRICAL EQUIPMENT WITH THE <br />ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 3/ 4" <br />L PIPING SHALL NOT PASS THROUGH K F ANY KIN G DUCTWORK 0 D UNLESS APPROVED BY THE <br />ENGINEER. WATTS 36 OR EQ. <br />M. PIPING SHALL NOT BE RUN ABOVE ELECTRICAL PANELS , THROUGH ELECTRICAL ROOMS OR VACUUM RELIEF VALVE <br />ANY OTHER WATER SENSITIVE AREAS, EXCEPT AS SPECIFICALLY NOTED ON PLANS. <br />7. SANITARY WASTE & VENT PIPING <br />A. ALL SANITARY WASTE & VENT PIPING ABOVE AND BELOW GROUND SHALL BE SCHEDULE 40 <br />PVC. ALL SANITARY WASTE PIPING 3" TO 6" SHALL BE SLOPED AT NO LESS THAN 1/8" PER <br />FOOT. ALL SANITARY WASTE 2" AND SMALLER SHALL BE SLOPED AT NO LESS THAN 34" PER c� <br />FOOT. <br />C. THE MINIMUM SANITARY WASTE & VENT PIPE SIZE SHALL BE 1". <br />I D. VERIFY LOCATIONS AND INVERT ELEVATIONS OF ANY AND ALL EXISTING WASTE, VENT, AND I <br />STORM DRAIN PIPING PRIOR TO BEGINNING ANY WORK. <br />EXIST 1" TEMP. & PRESS. <br />MAIN ALL BE TYPE "L" COPPER WITH WROUGHT / <br />S. DOMESTIC WATER PIPING <br />........ ._.. _.. ........ ......... ......... ....._. ..... ............................ ._................................................. ........ .............................................................................. .. ....................... RELIEF VALVE <br />,....A. ALL DOMESTIC WATER PIPING ABOVE GROUND SHALL / <br />._...... ......... ..___.. COPPER FITTINGS AND LEAD FREES R <br />B. ALL DOMESTIC WATER PIPING BELOW GROUND OR SLAB SHALL BE TYPE mKo COPPER WITH / \ <br />WROUGHT COPPER FITTINGS AND NO JOINTS BELOW FLOORS <br />DRAIN TO PAN <br />P-3 C. CPVC PIPING WITH CPVC FITTINGS AND PRIMED/GLUED JOINTS IS AN ACCEPTABLE SUBSTITUTE <br />P 1 FP-2 P 2 � � , I I'-4 JTO COPPER <br />UR SD CTIONPIPING IF INSTALLED PER FBC AND APPROVED BY THE AUTHORITY HAVING \\\\ <br />"HW <br />D ALL NEW WATER SUPPLY PIPING SHALL BE RUN OVERHEAD (DO NOT RUN WATER SUPPLY <br />\ \ <br />�7I PIPING BELOW CONCRETE FLOOR SLABS) UNLESS SPECIFICALLY STATED ON PLANS OR AS PROVIDE APPROVED \ DRAIN VALVE <br />H ABSOLUTELY NECESSARY TO MATCH AN EXISTING INSTALLATION. DRAIN PAN BELOW \ DRAIN TO PAN <br />1 "CW E yew HEATER, DRAIN TO <br />,.. D W ,... WATER S WITH 1 THICK, MIN. R-6, CLOSED FLOOR <br />p CELL ALL <br />INSULATION OR EQUIVALENT). OR EXTERIOR <br />w <br />( NT) <br />j"CW"CW"CW CV�I <br />» 1wHW 1: I HW �,. I : j»HW L... I HW I 9. NOT USED <br />CW" W <br />10. VENTS <br />"HW A. ALL TRAPS OR TRAPPED FIXTURES SHALL BE PROVIDED WITH AN INDIVIDUAL VENT UNLESS <br />OTHERWISE NOTED. <br />B. CONNECT ALL VENT PIPING SHOWN T EXISTING IN 0 0 D( STI G BUILDING MAIN VENT IN LO CAITON INDICATED D GATED <br />ELEC <br />TRIC WATER HEA <br />TER <br />p p " w <br />ON PLAN. <br />W CW <br />1 CW 1 CW <br />C C. SLOPE ALL HORIZONTAL VENTS SUCH THAT WATER MAY DRAIN BACK INTO THE SANITARY SCALE: N.T.S. <br />l. I"HW 1:...... h J"HW I I j"HW I I i"HW 1 "CW SYSTEM."CW <br />so "HW"CW»CWkD-+l� I A. THE�MAXIMUM HOT WATER DISCHARGE TEMPERATURE SHALL NOT EXCEED 110'F, UNLESS <br />HW I-IW 1 <br />HW:.. \ OTHERWISE NOTED ON PLANS. <br />B. PROVIDE ISOLATION VALVES AT THE INLET AND OUTLET OF ALL WATER HEATERS. <br />C. PROVIDE A SEPARATE DISCONNECT SWITCH FOR ALL ELECTRIC WATER HEATERS. <br />PLUMBING LEGEND I <br />-v---v- <br />HOT & COLD WATER PLUMBING PLAN <br />: 1/4" = 11-0" <br />NEW SANITARY WASTE PIPING <br />NEW COLD WATER PIPING <br />NEW HOT WATER PIPING <br />NEW VENT PIPING <br />POINT OF COINNECTION <br />GLOBE SHUTOFF VALVE <br />* TO THE BEST OF TIE ARCHITECT OR ENGINEER'S KNOWLEDGE AND <br />BELIEF, TI4ESE PLANS AND SPECIFICATIONS COMPLY WITH THE <br />FLORIDA BUILDING: CODE, 51I4 EDITION 2014. <br />$ THE DRAWINGS t DESIGN ARE VALID FOR 12 MONTHS FROM DATE <br />OF 5EMG SEALED. <br />TO T14E BEST OF THE IWOWLEDGE OF THE ARCHITECTS OR <br />ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH TIE <br />APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE <br />MINIMUM FIRE SAFETY STANDARDS. <br />ALL DIi'1E 48IONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE <br />CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED <br />TO THE ARCI.41TECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />ISSUE DATE BY: <br />REVIEW 01/15/15 <br />PERMIT 01ASAS <br />REV. <br />REV. <br />REV. <br />REV <br />TNEEE DOW°B M DEEIGNE, Wft =AD *0 <br />WECFICATM AND CONCE "AID M eoLE <br />PR MI I OF FRAM DEW NC. AND SWI NOT BE <br />F89i0MM, FE-UND OR COPED FOR OnVt <br />PROEM N THOLE OR PART Qi W M UWM <br />CO *W CP FROM NUM M CHMM, AW <br />ALL RIAn AM FEE RAW Or TEE ARCI-0W N <br />ACCOPOA42 tM UE: COP W*ff AND PAIW LM& <br />INABfNORI M FEI'RMCnON WU EE PROEECUMD <br />To TEE FULL Ex w CF M Lm <br />0 <br />00 <br />00 <br />M <br />g <br />o0 <br />rq <br />z <br />a <br />00 <br />w <br />I:k <br />o <br />� <br />M <br />00 <br />r% <br />iw. <br />a <br />' <br />00 <br />M <br />4 <br />b <br />w <br />r- <br />U <br />a <br />0 <br />w�a <br />SWEET TITLE <br />Hot 4 COLD WATNR <br />PI.Ui" ID ING <br />PLAN <br />SWEET NUMBS <br />