Laserfiche WebLink
HVAC EQUIPMENT TAG LEGEND <br />ZD EQUIPMENT DESIGNATION -SEE HVAC LEGEND <br />EQUIPMENT TAG NUMBER 2-2 AIR CONDITIONING SYSTEM NUMBER <br />HVAC ABBREVIATION LEGEND <br />AHU <br />AIR HANDLING UNIT <br />CU <br />CONDENSING UNIT <br />RTU <br />ROOFTOP PACKAGED UNIT <br />PACU <br />PACKAGED AIR CONDITIONING UNIT <br />EF <br />EXHAUST FAN <br />DH <br />DEHUMIDIFIER <br />VAD <br />VENTILATION AIR DAMPER <br />ZD <br />ZONE DAMPER <br />BD <br />BALANCE DAMPER <br />T <br />THERMOSTAT <br />DHC <br />DEHUMIDIFICATION CONTROL <br />C <br />CO2SENSOR /CONTROLLER <br />S <br />SHUT DOWN SMJKE DETECTOR <br />AF <br />AIR FILTRATION <br />CP <br />CONDENSATE PUMP <br />SA <br />SUPPLY AIR <br />RA <br />RETURN AIR <br />ODA <br />OUTDOOR AIR <br />MUA <br />MAKE-UP AIR <br />HVAC DIFFUSER TAG LEGEND <br />DIFFUSER SIZE LISTED IN INCHES <br />DESCRIPTION j-LENGTH x WIDTH <br />DESCRIPTION--,,. <br />2464 <br />200—DESIGN AIRFLOW C <br />HVAC DIFFUSER DESCRIPTION <br />8SUPPLY Ali DIFFUSER <br />0— 1 WAY CEILING MOUNT <br />SUPPLY AR DIFFUSER <br />2W 2 WAY CEILING MOUNT <br />3W <br />SUPPLY AR DIFFUSER <br />3 WAY CEILING MOUNT <br />SUPPLY AR DIFFUSER <br />4W <br />4 WAY CEILING MOUNT <br />$W SUPPLY AR DIFFUSER <br />SIDEWALL MOUNT <br />LR LAY -IN <br />RETURN DIFFUSER <br />LAY -IN <br />LD SUPPLY DIFFUSER 4W <br />DIFFUSER SIZES LISTED IN INCHES <br />LENGTH x WIDTH <br />HVAC DIFFUSER SPECIFICATIONS <br />SUPPLY DIFFUSER -CEILING <br />MANUFACTURER AIRGUIDE <br />MODEL: CBHML-(1,2,3,4)ME <br />DESCRIPTION: WHITE ALUMINUM <br />ADJUSTABLE CURVED BLADE WITH <br />PARALLEL BLADE DAMPER <br />SUPPLY DIFFUSER - LAY IN T-BAR <br />MANUFACTURER AIRGUIDE <br />MODEL LCD-T <br />DESCRIPTION: WHITE ALUMINUM <br />4 CONE HIGH CAPACITY LAY IN <br />DIFFUSER FOR T-BAR CEIUNIG. <br />RETURN DIFFUSER - LAY IN T-BAR <br />MANUFACTURER AIRGUIDE <br />MODEL: RA-T <br />DESCRIPTION: WHITE ALUMINUM <br />38' BLADE NON -FILTER BACK <br />DIFFUSER FOR T-BAR CEILING. <br />FLEX DUCT TO METAL DUCT CONNECTION DETAIL <br />TAKE -OFF COLLAR FOR ROUND PIPE <br />WITH THERMA-SEAL GASKET FLANGE & <br />BALANCE DAMPER METAL DUCT REDUCER <br />SHEET METAL SCREW TO PIPE. <br />SEAL WITH 0190 SILVER TAPE & rV HANGER STRAP FOR <br />#9 MAS"IC AIR SEALAN I FLEXIBLE DUCT(EVERY <br />+ 4' OF FLEXIBLE DUCT) <br />V METAL HANGER STRAP <br />AT EACH END OF ROUND <br />METAL DUCT. <br />CLASS 1 FLEXIBLE AIR DUCT <br />— <br />R-6 INSULATION <br />CONNECT FLEX TO METAL DUCT <br />WITH 0810 SILVER TAPE, <br />PANDUIT STRAP, & #9 MASTIC <br />AIR SEALANT <br />ROUND MEAL DUCT -GALVANIZED <br />METAL SNAPLOCK PIPE. <br />SEAL SNAP LOCK <br />SEAM WITH 0180 SILVER TAPE. <br />EXTERIOR WRAPPED <br />INSULATION SHALL BE R-6. <br />RETURN AIR GRILL PLENUM <br />12'0 or Larger <br />Ductboard Ninlm— <br />R-4 Insulation <br />Return Air W <br />RETURN DUCTS 12'0 OR <br />LARGER SHALL TERMINATE AT <br />A PLENUM STYLE REGISTER <br />BOX <br />BALANCE DAMPER COLLAR <br />Ductwork <br />Balance Damper(BD) <br />Collar -Crown Product) <br />616-D or Equal <br />A/C DUCT WORK SPECIFICATIONS <br />SIZE/ROUND <br />FLEXIBLE DUCT <br />CLASS 1 FLEXIBLE DUCT WITH SILVER VAPOR <br />JACKET. <br />R-VALUE 6 <br />MANUFACTURER: ATCO MODEL <br />SIZE/ROUND <br />METAL DUCT ROUND <br />GALVANIZED METAL SNAPLOCK PIPE WITH <br />SILVER <br />DUCT WRAP. <br />R VALUE = 6 <br />MANUFACTURER:CERTAINTEED <br />SOFT TOUCH <br />SIZEANxH <br />DUCTBOARD RECTANGLE <br />CERTAINTEED BLACK 'TOUGHGARD" DUCT <br />BOARD. R-VALUE 6 <br />ALL DUCT SIZES LISTED ON PLANS ARE INSIDE <br />DIAMETER AND ARE LISTED IN INCHES. <br />ADD 3' TO EACH DIMENSIOV FOR OUTSIDE DIAMETER <br />.....Y ... ,... . _. ... _. ,. __-,.. _.._... ... _. ..i __�... _.. ... ... ._ ,. ....,_._. _.. _. ..._.,..J. _. ....._._ ____ ..-.-_.. .J .... ___,. .. ... ... .. -., .. ._._. __ _. 1 MASSAGE' ROOM X H <br />M GE{ R E CRi R 11 <br />r.-.,._.....__._i..._._._.._._�..+ <br />RECEPTION/MA <br />NkURE i i ; i PEDICURE i ` s _ .._ _ _ _. __ _. i _ ._ _ _ i _ _... _ ._ <br />EMP4OYEE AREAoo <br />i I i <br />I i <br />, <br />i P a" <br />—r - <br />OFFICE <br />DIFFUSER COORDINATION PLAN <br />SCALE: 1/4" = 1' <br />HVAC PLAN <br />SCALE: 1/4" = 1' <br />N <br />Vent Cap with Bads <br />Draft Damper. <br />No Screen. <br />ewali Exhaust <br />.ap with <br />Screen <br />_utdoor <br />Air Intake Cap with <br />Insect Screen <br />TYPICAL VERTICAL AIR HANDLER DETAIL <br />GALVANIZED METAL <br />SUPPLY AIR PLENUM WITH <br />R-6 LINED INSULATION — <br />FIELD INSTALLED <br />REFRIGERANT LINE SET <br />WITH INSULATED SUCTION <br />LINE(MINIMUM R-3) <br />CONDENSATE DRAIN <br />LINE CUT-OFF SWITCH <br />3/4" SCHEDULE 40 PVC — <br />WITH 1/2" TUBE <br />INSULATION <br />RETURN AIR <br />4" POURED <br />CONCRETE <br />VERTICAL AIR HANDLING UNIT <br />OUTSIDE AIR DUCT <br />1 (VAD) VENTILATION AIR DAMPER <br />Oro MANUAL BALANCE DAMPER <br />GALVANIZED METAL RETURN <br />AIR BASE PLATFORM WITH R-4 <br />LINED INSULATION <br />TER LOCATION <br />CONDENSING UNIT CONCRETE <br />SLAB MOUNTING DETAIL <br />1 'MINIMUM CLEARANCE: <br />TO WALL <br />O <br />VAN1.25' STE=L CONDENSER TIE DOWN CLIP. <br />114" TEK SCREWS ANCHORED TO UNIT PER <br />MANUFACTURER'S SPECIFICATIONS. <br />2' TAPCON ANCHOR TO CONCRETE SLAB. <br />TOTAL OF 4 CLIPS. 1 PER SIDE. <br />MANUFACTURER-BMP INDUSTRIES OR EQUAL. <br />PRODUCT MUST BE FBC APPROVED. <br />LEVEL <br />1 <br />J 00 <br />rn� � <br />v/ 0) <br />ZI-- <br />O l() <br />CM <br />D U N <br />4 <br />m LLJ <br />CL U <br />Z <br />Z � 4< <br />U W - <br />r <br />-� O <br />m <br />U W= <br />1..� E <br />V <br />Z o. <br />Q •c <br />H <br />Jr <br />N <br />r <br />m <br />Z Q � Q <br />H C) Q <br />Q w O <br />O Z j _j <br />Z Q 0 LL <br />W U) O J <br />J <br />0 Q <br />of <br />Z <br />W Q <br />}— Z (� <br />Z N M = <br />Z Z) r- �- <br />Q U) � N <br />DATE: 07.14.15 <br />DR. BY: RM <br />FILE: SUZINNAILSANDSPA—M <br />SHEET <br />