_- - --- --- -- - -- - -- - �- - - -- - - - - r n i -- - .`r+' -J ' � �' - - - - L' i I � �,.ail�r�rrL+•-.----��. �� - -- �..-+�t� �' .. ----- � �_ly�+ --: �_ �1 ( '��i1{1..11\ <br />SPLIT AIR CONDITIONING SYSTEM SCHEDULE <br />TOTAL CAPACITY BTUH <br />53,845 <br />SENSIBLE CAPACITY BTUH <br />41,878 <br />w <br />HEATING CAPACITY BTUH(47' ODT) <br />- <br />} <br />MANUFACTURER <br />CARRIER <br />N <br />SEER <br />14.50 <br />NOMINAL TONNAGE <br />5.0 <br />DESIGNATION <br />AHU-1 <br />MODEL NO. <br />FV4CNB006L <br />z <br />UNIT WEIGHT LB. <br />Na <br />z <br />z <br />SUPPLY AIR CFM <br />1,750 <br />x <br />OUTDOOR AIR CFM <br />169 <br />w <br />ENTERINGAIR TEMP. DB/WB <br />75/63 <br />a <br />EXTERNAL STATIC PRESS. IN. W. G. <br />0.7" <br />INDOOR FAN FLA <br />6.8 <br />ELECTRIC HEAT KW <br />8 <br />MCA/MOCP <br />48.5/50 <br />DESIGNATION <br />CU-1 <br />I- <br />MODEL NO. <br />24ACC46OA-30 <br />3 <br />O <br />UNIT WEIGHT LB. <br />Na <br />z <br />COMPRESSOR R.L.A. <br />20.8 <br />0 <br />OUTDOOR FAN FLA <br />1.52 <br />U <br />OUTDOOR DESIGN TEMP. DB <br />95 <br />M CA/MOCP <br />27.5/40 <br />IL <br />ELECTRIC SERVICE <br />2081230-1-60 <br />1. AIR FILTERS SHALL BE FIELD INSTALLED. PROVIDE WASHABLE FILTER FOR EACH AHU <br />LOCATED AT AHU FILTER ACCESS. FILTER BACK RETURN AIR GRILLS SHALL NOT BE USED. <br />2. PROVIDE (T) 5-2 PROGRAMMABLE THERMOSTAT. <br />3. EQUAL ALTERNATIVE MANUFACTURER IS ACCEPTABLE. <br />4. ALTERNATE EQUIPMENT SHALL MEET THE TOTAL AND SENSIBLE BTUh CAPACITIES OF THE <br />A/C EQUIPMENT SPECIFIED IN THESE PLANS. <br />5. ALTERNATE EQUIPMENT SHALL MEET THE SEER RATING OF THE EQUIPMENT SPECIFIED. <br />EXHAUST FAN SCHEDULE <br />DESIGNATION <br />EF #1 <br />FAN TYPE <br />CEILING <br />DRIVE TYPE <br />DIRECT <br />AIR FLOW CFM <br />68 <br />STATIC PRESS. IN, W.G. <br />0.25 <br />ELECTRIC SERVICE <br />120/l/60 <br />MAX AMPS <br />0.4 <br />MANUFACTURER <br />BROAN <br />MODEL NO. <br />684 <br />ACCESSORIES <br />1 <br />1. WIRE TO LIGHT SWITCH. <br />VENTILATION AIR CALCULATIONS <br />ASHRAE 62.2 - CHAPTER 4 <br />REFERENCE TABLE 4.1 <br />OCCUPANCY CATEGORY -BEAUTY/NAIL SALON <br />RP 25 <br />CFM OUTDOOR AIR FLOW RATE <br />Pz 12 <br />OCCUPANTS <br />Vbz 300 <br />CFM, BREATHING ZONE OA FLOW <br />Ez 1.0 <br />ZONE AIR DISTRIBUTION EFFECT <br />Voz 300 <br />MINIMUM REQUIRED ZONE OUTDOOR AIR FLOW <br />'OUTSIDE AIR REQUIREMENTS ARE IN ACCORDANCE WITH FLORIDA MECHANICAL <br />CODE 2014 AND ASHRAE 2010-62.1, VENTILATION FOR ACCEPTABLE <br />INDOOR AIR QUALITY <br />CO2 <br />CONTROL <br />SCHEDULE <br />SYSTEM <br />DESGINATION <br />CO2 BRAND <br />CO2 MODEL <br />DESCRIPTION <br />SYSTEM #1 <br />C <br />HONEYWELL <br />C7232A1006 <br />WALL MOUNT CO2 <br />FOR ON DEMAND VENTILATION. <br />DUCT MOUNT CO2 SENSOR AND CONTROLLER. <br />WIRE TO CORRESPONDING VENTILATION AIR DAMPER(VAD). <br />SET CO2 SENSOR TO OPEN UPON CO2 RISE AT 1000 PPM. <br />SET CO2 SENSOR TO CLOSE UPON A CO2 DROP OF 1D0 PPM. <br />VENTILATION AIR DAMPER SCHEDULE <br />VENT. DAMPER <br />BRAND <br />MODEL <br />CFM <br />LOCATION <br />DESGINATION <br />VAD #1 <br />HONEYWELL <br />EARD 6 <br />300 CFM <br />ODA #1 <br />NOTES: VAD #1 <br />VAD - NORMALLY CLOSED 24V DAMPER. <br />ON DEMAND VENTILATION FOR OCCUPANCY. <br />WIRE VAD TO OPEN WITH CORRESPONDING CO2 SENSOR. <br />SEE CO2 SENSOR SCHEDULE FOR SENSOR SETTINGS. <br />HVAC NOTES: <br />GENERAL NOTES <br />1. <br />ALL WORK TO BE DONE IN ACCORDANCE WITH THESE PLANS & THE 2014 FLORIDA BUILDING CODE. <br />2. <br />MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE & ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL. THE HVAC CONTRACTOR SHALL INCLUDE THE FURNISHINGS OF ALL LABOR AND <br />MATERIALS TO COMPLETE THE AIR CONDITIONING, HEATING, AND VENTILATION SHOWN ON THE DRAWINGS TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: <br />• <br />PERMIT FEES <br />• <br />ALL AIR CONDITIONING EQUIPMENT <br />• <br />EXHAUSTFANS <br />• <br />SUPPLY, RETURN, VENTILATION, & EXHAUST AIR DUCT WORK <br />• <br />SUPPLY AND RETURN DIFFUSERS AND REGISTERS, DAMPERS, WEATHERPROOF VENTILATION & EXHAUST LOWERS <br />• <br />AIR FILTRATION <br />• <br />THERMOSTATS, CO2 SENSORS, SHUT DOWN SWITCHES & RELATED CONTROL WIRING <br />• <br />EQUIPMENT SUPPORTS, HANGERS, & RACKS <br />• <br />CONDENSATE DRAIN PANS & PIPING <br />• <br />REFRIGERANT FIELD COPPER LINE SET & PIPING <br />3. <br />ALL WORK SHALL BE PERFORMED BY A LICENSED HVAC CONTRACTOR CERTIFIED IN THE STATE OF FLORIDA. <br />z <br />4, <br />THE HVAC CONTRACTOR SHALL VISIT THE JOB SITE, MEET WITH RELATED TRADES, & FAMILIARIZE THEMSELVES WITH ANY AND ALL CONDITIONS RELATED TO THEIR WORK. <br />O <br />5. <br />ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED. ANY CHANGES OR DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY ENGINEER OF RECORD. <br />Q <br />O <br />6. <br />AIR CONDITIONING AND HEATING EQUIPMENT SHALL BE NOT BE SIZED BASED ON A.R.I. CAPACITY RATINGS, BUT RATHER BASED ON SPECIFIC DESIGN CONDITIONS. <br />7. <br />REVISIONS OR CHANGES FROM THESE PLANS THAT MAY BE REQUIRED BECAUSE OF CONTRACTOR OPTED REVISIONS, SHALL BE COMPENSATED TO THE ENGINEER OF RECORD BY THE <br />J <br />b <br />fco <br />REQUESTING CONTRACTOR. <br />♦� <br />VJ <br />Z� <br />SPLIT SYSTEM AIR CONDITIONING EQUIPMENT <br />V J <br />O <br />LC) <br />1. <br />CONDENSING UNIT SHALL BE INSTALLED AS PER SECTION 304.1 AND 304.2 OF THE 2014 FLORIDA BUILDING CODE. <br />Q <br />v <br />M <br />2. <br />CONDENSING UNIT SHALL BE LOCATED SLAB ON GRADE. TIE DOWN WITH FBC APPROVED HURRICANE STRAPS. <br />m <br />ZLL <br />W <br />3. <br />4. <br />CLEARANCE AROUND NON SERVICE SIDES OF THE CONDENSING UNIT SHALL COMPLY WITH MANUFACTURERS RECOMMENDATIONS AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS, <br />CLEARANCE ABOVE THE CONDENSING UNIT SHALL COMPLY WITH RECOMMENDATION AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />U <br />MANUFACTURERS <br />c�Op <br />5. <br />AIR HANDLERS SHALL BE INSTALLED AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND THE 2014 FLORIDA BUILDING CODE. <br />z <br />-c <br />6. <br />THE AIR HANDLER SHALL INCORPORATE A FILTER HOUSING WITH EASY ACCESS. THE FILTER COMPARTMENT SHALL NOT BE OBSTRUCTED IN ANY WAY BY THE REFRIGERANT PIPING, <br />a <br />Z <br />/ ) <br />�/5 <br />j <br />CONDENSATE PIPING, ORANY OTHER ITEM WHICH MAY PREVENT REMOVAL AND INSTALLATION OF THE FILTER. <br />� <br />co <br />7. <br />FILTERS SHALL BE LOCATED AT THE AIR HANDLER DIRECTLY BEFORE THE EVAPORATOR COIL. NO FILTER BACK GRILLS SHALL BE USED. <br />V_ <br />11 <br />` <br />(p <br />8. <br />CLEARANCE AROUND THE AIR HANDLER SHALL BE 4" FOR NON -SERVICE SIDES AND 36' FOR SERVICE SIDE. <br />tY <br />0 <br />M <br />r` <br />-D <br />> <br />O <br />�/� <br />m <br />L.L <br />CONDENSATE DISPOSAL <br />U <br />W <br />C <br />1. <br />CONDENSATE DISPOSAL SHALL BE PROVIDED FOR EQUIPMENT AND APPLIANCES CONTAINING EVAPORATOR COILS. <br />E <br />2. <br />CONDENSATE DRAIN SYSTEM SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SECTIONS 307.2.1 THROUGH 307.2.4 OF THE 2014 FLORIDA BUILDING CODE. <br />(D <br />Q <br />3. <br />ALL PRIMARY CONDENSATE PIPING LOCATED WITHIN THE INSIDE OF THE BUILDING SHALL BE INSULATED TO PREVENT CONDENSATION FROM FORMING ON THE EXTERIOR OF THE DRAIN <br />z <br />cl) <br />LINE. <br />4. <br />MAIN AND EMERGENCY CONDENSATE DRAIN LINES SHALL BE SCHEDULE 40 PVC. <br />.� <br />~ <br />5. <br />AUXILIARY DRAIN LINE CONNECTION AT THE EVAPORATOR DRAIN PAN SHALL INCORPORATE AN SAFETY CUT-OFF SWITCH. <br />6. <br />AIR HANDLERS SHALL INCORPORATE AN EMERGENCY DRAIN PAN THAT IS PIPED TO A CONSPICUOUS LOCATION AT THE EXTERIOR OF THE BUILDING OR INCORPORATES A SAFETY CUT-OFF <br />iV <br />SWITCH. <br />7. <br />SLOPE HORIZONTAL CONDENSATE DRAINS A MINIMUM OF 1/4" PER FOOT. <br />co <br />8. <br />CONDENSATE SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, SIDEWALK, OR ANY OTHER <br />LOCATION AS TO CAUSE A NUISANCE. IF NO APPROVED LOCATION IS AVAILABLE, THEN A DRY WELL SHALL BE INSTALLED. <br />9. <br />ALL DRAIN LINES SHALL BE PROVED AND TESTED UPON EQUIPMENT START-UP. <br />10. <br />ALL DRAIN LINE AND DRAIN PAN SAFETY CUT OFF CONTROLS SHALL BE TESTED UPON EQUIPMENT START-UP. <br />DUCTWORK <br />1. <br />DUCT CONSTRUCTION AND INSTALLATION SHALL COMPLY WITH SECTION M603 OF THE 2014 FLORIDA BUILDING CODE. <br />2. <br />AIR CONDITIONING DUCT SYSTEM MATERIALS SHALL BE BASED ON THE FOLLOWING: <br />• <br />FLEXIBLE DUCT WORK - BRAND - ATCO #036 / UL 181, CLASS 1 AIR DUCT WITH REINFORCED METALLIZED POLYESTER JACKET WITH WIRE HELIX ENFORCED AIR TIGHT INNER LINER. <br />INSULATION SHALL BE R-6. <br />• <br />ROUND METAL DUCT WORK - CROWN #101 SNAPLOCK ROUND PIPE. DUCT SIZE 14"0 OR LESS SHALL BE 30 GAUGE MINIMUM. DUCT SIZE OVER 14"0 SHALL BE 28 GAUGE MINIMUM. DUCT <br />SHALL BE INSULATED WITH CERTAINTEED EXTERIOR WRAP WITH R-6 INSULATION & VAPOR RETARD FACING, <br />• <br />INSULATION VALUE SHALL BE R-6. <br />• <br />RECTANGLE DUCT - CERTAINTEED BLACK TOUGHGARD. UL 181 / CLASS 1 DUCT BOARD WITH BLACK MAT FACING AND VAPOR RETARD FACING. THE AIR STREAM SURFACE CONTAINS AN EPA <br />REGISTERED ANTI -MICROBIAL AGENT IN ORDER TO REDUCE THE POTENTIAL OF MICRO GROWTH ON THIS PRODUCT. <br />• <br />INSULATION VALUE SHALL BE R-6. <br />3. <br />ALL DUCT SIZES LISTED ARE NET INSIDE DIMENSIONS. <br />Q <br />Q <br />4. <br />ALL DUCTS AND PLENUMS SHALL BE MADE AIR TIGHT. DUCT WORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION OF CHAPTER 13 OF THE 2014 <br />Z <br />< <br />a. <br />Q <br />FLORIDA BUILDING CODE. <br />O_ <br />5. <br />DUCT LEAKAGE SHALL NOT EXCEED 5% OF THE RATED AIR HANDLER FLOW.- <br />�+ <br />6. <br />BRANCH DUCT RUN -OUTS SHALL HAVE A MANUAL BALANCE DAMPER AT THE CONNECTION TO THE MAIN TRUNK LINE. DAMPER SHALL BE HAVE AN INDICATOR FLAG ATTACHED TO THE <br />\ <br />Q <br />w <br />O <br />DAMPER FOR EASY IDENTIFICATION. <br />/ <br />Z <br />7. <br />FLEXIBLE DUCT SHALL BE EXTENDED TO ITS FULL LENGTH. EXCESS DUCT MATERIAL IN A RUN SHALL BE LESS THAN 5%. <br />Z <br />8. <br />FLEXIBLE DUCT SHALL BE SUPPORTED AT MANUFACTURERS RECOMMENDED INTERVALS, BUT AT NO GREATER DISTANCE THAN 4 FEET. MAXIMUM PERMISSIBLE SAG IS 1/2" PER FOOT OF <br />W <br />♦ <br />O <br />I _ <br />SPACING BETWEEN SUPPORTS. <br />� <br />V / <br />U) <br />9. <br />FIRE DAMPERS SHALL BE INSTALLED INSTALLED IN ACCORDANCE WITH SECTION 716 OF THE 2014 FLORIDA BUILDING CODE. <br />N <br />W <br />J <br />10. <br />DUCTS AND TRANSFER OPENINGS THAT PENETRATE FIRE RESITANT-RATED ASSEMBLIES AND ARE NOT REQUIRED BY THIS SECTION TO HAVE DAMPERS, SHALL COMPLY WITH THE <br />0 <br />REQUIREMENTS OF SECTION 712 OF THE 2014 FLORIDA BUILDING CODE. <br />�-/ <br />J <br />11. <br />SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION M606 OF 2014 FLORIDA BUILDING CODE. <br />Lu L.L <br />Q <br />�- <br />Z_ <br />(� <br />�■ <br />Z <br />N <br />or <br />Z <br />- <br />r <br />a - <br />AIR REGISTERS BOXES AND DIFFUSERS <br />Q <br />C7 <br />W <br />N <br />1. <br />REFER TO DIFFUSER LEGEND FOR MANUFACTURER TYPE AND MODEL. ALTERNATE DIFFUSERS MUST BE APPROVED BY ENGINEER OF RECORD. <br />2. <br />DIFFUSER LOCATIONS ARE FOR GENERAL REFERENCE. FIELD VERIFY DIFFUSER LOCATIONS AND COORDINATE WITH CEILING LIGHTING AND INTERIOR CEILING <br />ELEVATIONS. <br />OUTDOOR AIR & EXHAUST AIR SYSTEMS <br />1. <br />ALL EXHAUST DUCTS SHALL TERMINATE TO EXTERIOR ROOF CAP, SIDEWALL CAP, OR SOFFIT HOOD AS INDICATED ON THE HVAC PLANS. <br />2. <br />EXHAUST FANS SHALL HAVE BACK DRAFT DAMPER INSTALLED, <br />3. <br />OUTDOOR AIR DUCT SHALL BE CONNECTED TO THE RETURN SIDE OF THE AIR STREAM AT THE RETURN AIR PLENUM. <br />4. <br />OUTDOOR AIR DUCT SHALL INCORPORATE A MANUAL VOLUME BALANCE DAMPER AT THE RETURN AIR PLENUM FOR INTAKE BALANCE. <br />5. <br />OUTDOOR AIR SHALL INCORPORATE A NORMALLY CLOSED (24V) DAMPER(VAD). <br />6. <br />WIRE VAD TO CO2 SENSOR. <br />7. <br />VAD SHALL OPEN ON CO2 RISE. VAD SHALL CLOSE ON CO2 FALL. <br />8. <br />SEE CO2 SENSOR SCHEDULE FOR SETTINGS. <br />9. <br />OUTDOOR AIR INTAKES SHALL HAVE INSECT SCREEN AT INTAKE CAP. <br />DATE: 07.14.15 <br />10. <br />KEEP ALL VENTILATION AIR INTAKES A MINIMUM 10' FROM EXHAUST FAN TERMINATION POINTS AND SANITARY SEWER VENT OUTLETS. <br />DR. BY: RM <br />FILE: SUZINNAILSANDSPA-M <br />SHEET <br />.;, <br />M-2' <br />