Laserfiche WebLink
c <br />c <br />m <br />O <br />EI <br />ti <br />O <br />NI <br />J <br />LL <br />t <br />O <br />ca <br />06 <br />O <br />co <br />YI <br />U <br />E. <br />M <br />U) <br />C: <br />N <br />U <br />O <br />0 <br />c <br />C <br />C <br />ca <br />O <br />E. <br />N <br />CD <br />Z) <br />�` <br />b <br />N <br />co <br />O <br />T_ <br />»0 <br />T_ <br />O <br />N <br />u7 <br />N <br />O <br />FINISHES <br />SECTION 09216 - NON -LOAD -BEARING STEEL FRAMING <br />1.1 SUMMARY <br />A. NON -LOAD -BEARING STEEL FRAMING MEMBERS FOR INTERIOR FRAMING <br />SYSTEMS. <br />1.2 MATERIALS <br />A. STEEL FRAMING FOR FRAMED ASSEMBLIES: <br />B. FRAMING MEMBERS, GENERAL: COMPLY WITH ASTM C 754 FOR CONDITIONS <br />INDICATED. <br />1. STEEL SHEET COMPONENTS: COMPLY WITH ASTM C 645 <br />REQUIREMENTS FOR METAL, UNLESS OTHERWISE INDICATED. <br />2. PROTECTIVE COATING: COATING WITH EQUIVALENT CORROSION <br />RESISTANCE OF ASTM A 653/A 653M, G40 (Z120), HOT -DIP <br />GALVANIZED, UNLESS OTHERWISE INDICATED. <br />1.3 STEEL FRAMING FOR FRAMED ASSEMBLIES <br />A. SALVAGED MATERIAL: USE SALVAGED FRAMING MATERIALS WHENEVER <br />AVAILABLE. <br />B. STEEL STUDS AND RUNNERS: ASTM C 645. <br />1. MINIMUM BASE -METAL THICKNESS: 0.033 INCH (0.84 MM) UNLESS <br />OTHERWISE INDICATED ON DRAWINGS. <br />2. DEPTH: AS INDICATED ON DRAWINGS. <br />C. DIMPLED STEEL STUDS AND RUNNERS: <br />1. MINIMUM BASE -METAL THICKNESS: 0.025 INCH (0.64 MM). <br />2. DEPTH: AS INDICATED ON DRAWINGS. <br />D. SLIP -TYPE HEAD JOINTS: WHERE INDICATED, PROVIDE ONE OF THE <br />FOLLOWING: <br />1. SINGLE LONG -LEG RUNNER SYSTEM: ASTM C 645 TOP RUNNER <br />WITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT LESS <br />THAN INDICATED FOR STUDS, INSTALLED WITH STUDS FRICTION FIT <br />INTO TOP RUNNER AND WITH CONTINUOUS BRIDGING LOCATED <br />WITHIN 12 INCHES (305 MM) OF THE TOP OF STUDS TO PROVIDE <br />LATERAL BRACING. <br />2. DOUBLE -RUNNER SYSTEM: ASTM C 645 TOP RUNNERS, INSIDE <br />RUNNER WITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT <br />LESS THAN INDICATED FOR STUDS AND FASTENED TO STUDS, AND <br />OUTER RUNNER SIZED TO FRICTION FIT INSIDE RUNNER. <br />3. DEFLECTION TRACK: STEEL SHEET TOP RUNNER MANUFACTURED <br />TO PREVENT CRACKING OF FINISHES APPLIED TO INTERIOR <br />PARTITION FRAMING RESULTING FROM DEFLECTION OF STRUCTURE <br />ABOVE; IN THICKNESS NOT LESS THAN INDICATED FOR STUDS AND <br />IN WIDTH TO ACCOMMODATE DEPTH OF STUDS. <br />E. COLD -ROLLED CHANNEL BRIDGING: 0.0538 INCH (1.37 MM) BARE -STEEL <br />THICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES. <br />1. DEPTH: 1-1/2 INCHES (38.1 MM). <br />2. CLIP ANGLE: NOT LESS THAN 1-1/2 BY 1-1/2 INCHES (38.1 BY <br />38.1 MM), 0.068 INCH (1.73 MM) THICK, GALVANIZED STEEL. <br />F. HAT -SHAPED, RIGID FURRING CHANNELS: ASTM C 645. <br />1. MINIMUM BASE METAL THICKNESS: AS INDICATED ON DRAWINGS. <br />2. DEPTH: AS INDICATED ON DRAWINGS. <br />G. COLD -ROLLED FURRING CHANNELS: 0.0538 INCH (1.37 MM) BARE -STEEL <br />THICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES. <br />1. DEPTH: AS INDICATED ON DRAWINGS. <br />2. FURRING BRACKETS: ADJUSTABLE, CORRUGATED -EDGE TYPE OF <br />STEEL SHEET WITH MINIMUM BARE -STEEL THICKNESS OF <br />0.0312 INCH (0.79 MM). <br />3. TIE WIRE: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT <br />TEMPER, 0.0625 INCH (1.59 MM) DIAMETER WIRE, OR DOUBLE <br />STRAND OF 0.0475 INCH (1.21 MM) DIAMETER WIRE. <br />H. Z-SHAPED FURRING: WITH SLOTTED OR NONSLOTTED WEB, FACE FLANGE <br />OF 1-1/4 INCHES (31.8 MM), WALL ATTACHMENT FLANGE OF 7/8 INCH <br />(22.2 MM), MINIMUM BARE -METAL THICKNESS OF 0.0179 INCH (0.45 MM), AND <br />DEPTH REQUIRED TO FIT INSULATION THICKNESS INDICATED. <br />END OF SECTION 09216 <br />SECTION 092900 - GYPSUM BOARD <br />1.1 SUMMARY <br />A. INTERIOR GYPSUM BOARD. <br />B. TILE BACKING PANELS. <br />1.2 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. <br />B. SAMPLES: FOR THE FOLLOWING PRODUCTS: <br />1. TEXTURED FINISHES: MANUFACTURER'S STANDARD SIZE FOR EACH <br />TEXTURED FINISH INDICATED AND ON SAME BACKING INDICATED <br />FOR WORK. <br />1.3 MATERIALS <br />A. INTERIOR GYPSUM BOARD: <br />1. GENERAL: COMPLYING WITH ASTM C 36/C 36M OR <br />ASTM C 1396/C 1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD <br />INDICATED AND WHICHEVER IS MORE STRINGENT. <br />a. MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION <br />MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF <br />HEALTH SERVICES' "STANDARD PRACTICE FOR THE <br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM <br />VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL <br />CHAMBERS", INCLUDING 2004 ADDENDA OR A <br />JURISDICTIONALLY RECOGNIZED STANDARD USING <br />VALENT TESTING METHODOLOGIES AND VOC THRESHOLDS. <br />2. TYPE X: <br />a. THICKNESS: 5/8 INCH (15.9 MM). <br />b. LONG EDGES: TAPERED. <br />3. MOISTURE- AND MOLD -RESISTANT TYPE: WITH MOISTURE- AND <br />MOLD -RESISTANT CORE AND SURFACES. <br />a. CORE: 5/8 INCH (15.9 MM), TYPE X. <br />b. LONG EDGES: TAPERED. <br />c. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED <br />ACCORDING TO ASTM D 3274. <br />B. TILE -BACKING PANELS: <br />1. GLASS -MAT, WATER-RESISTANT BACKING BOARD: <br />ASTM C 1178/C 1178M, WITH MANUFACTURER'S STANDARD EDGES. <br />a. MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION <br />MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF <br />HEALTH SERVICES"'STANDARD PRACTICE FOR THE <br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM <br />VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL <br />CHAMBERS", INCLUDING 2004 ADDENDA OR A <br />JURISDICTIONALLY RECOGNIZED STANDARD USING <br />EQUIVALENT TESTING METHODOLOGIES AND VOC <br />THRESHOLDS. <br />b. CORE: 5/8 INCH (15.9 MM), TYPE X. <br />c. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED <br />ACCORDING TO ASTM D 3274. <br />2. CEMENTITIOUS BACKER UNITS: ANSI A118.9 AND <br />ASTM C 1288 OR 1325, WITH MANUFACTURER'S STANDARD EDGES. <br />a. THICKNESS: [1/4 INCH (6.4 MM)] [AS INDICATED]. <br />b. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED <br />ACCORDING TO ASTM D 3274. <br />C. TRIM ACCESSORIES: <br />a. INTERIOR: CORNERBEAD. <br />END OF SECTION 092900 <br />FINISHES (CONTINUED <br />SECTION 093000 - CERAMIC TILE <br />1.1 SUMMARY <br />A. PAVER, GLAZED, AND WALL TILE. <br />B. WATERPROOF MEMBRANE FOR THIN -SET TILE INSTALLATIONS. <br />C. METAL EDGE STRIPS INSTALLED AS PART OF TILE INSTALLATIONS. <br />1.2 QUALITY ASSURANCE <br />A. MOCKUPS FOR EACH FORM OF CONSTRUCTION. <br />1.3 MATERIALS <br />A. GLAZED WALL TILE TRIM SHAPES: COVED BASE, BULLNOSE CAP. <br />B. THRESHOLDS: SATIN ANODIZED ALUMINUM THRESHOLDS AND TRANSITION <br />STRIPS. <br />1. BEVEL EDGES AT 1:2 SLOPE, WITH LOWER EDGE OF BEVEL ALIGNED <br />WITH OR UP TO 1/16 INCH (1.5 MM) ABOVE ADJACENT FLOOR <br />SURFACE. FINISH BEVEL TO MATCH TOP SURFACE OF THRESHOLD. <br />LIMIT HEIGHT OF THRESHOLD TO 1/2 INCH (12.7 MM) OR LESS ABOVE <br />ADJACENT FLOOR SURFACE. <br />C. MORTAR: LATEX-PORTLAND CEMENT <br />D. ELASTOMERIC SEALANTS: ONE -PART, MILDEW -RESISTANT SILICONE. <br />1. SEALANTS SHALL HAVE A VOC CONTENT OF [250] <INSERT VALUE> <br />G/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, <br />SUBPART D (EPA METHOD 24). <br />1.4 FLOOR TILE INSTALLATION SCHEDULE <br />A. INTERIOR FLOORS ON CONCRETE: THIN -SET MORTAR. <br />1. TILE TYPE: UNGLAZED PAVER TILE. <br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT. <br />3. GROUT: POLYMER -MODIFIED UNSANDED 100% SOLIDS EPDXY <br />NON -SAGGING GROUT. <br />B. INTERIOR FLOORS ON [WATERPROOF] [CRACK -SUPPRESSION] MEMBRANE <br />OVER CONCRETE AND WOOD: THIN -SET MORTAR. <br />1. TILE TYPE: UNGLAZED PAVER TILE. <br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT. <br />3. GROUT: POLYMER -MODIFIED UNSANDED 100% SOLIDS EPDXY <br />NON -SAGGING GROUT. <br />1.5 WALL TILE INSTALLATION SCHEDULE <br />A. INTERIOR WALLS OVER GLASS -MAT WATER-RESISTANT BACKER BOARD OR <br />CEMENTITIOUS BACKER UNITS: THIN -SET MORTAR. <br />1. TILE TYPE: [UNGLAZED CERAMIC MOSAIC] [GLAZED CERAMIC <br />MOSAIC] [GLAZED WALL] TILE. <br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR. <br />3. GROUT: POLYMER -MODIFIED UNSANDED GROUT. <br />END OF SECTION 093000 <br />SECTION 095113 - ACOUSTICAL PANEL CEILINGS <br />1.1 SUMMARY <br />A. ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS. <br />1.2 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. <br />B. COORDINATION DRAWINGS: REFLECTED CEILING PLANS, DRAWN TO SCALE, <br />ON WHICH THE FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH <br />EACH OTHER, BASED ON INPUT FROM INSTALLERS OF THE ITEMS <br />INVOLVED: <br />1. CEILING SUSPENSION SYSTEM MEMBERS. <br />2. METHOD OF ATTACHING HANGERS TO BUILDING STRUCTURE. <br />3. CEILING -MOUNTED ITEMS INCLUDING LIGHTING FIXTURES, <br />DIFFUSERS, GRILLES, SPEAKERS, SPRINKLERS, ACCESS PANELS, <br />AND SPECIAL MOLDINGS. <br />C. SAMPLES FOR VERIFICATION: FOR EACH COMPONENT INDICATED AND FOR <br />EACH EXPOSED FINISH REQUIRED, PREPARED ON SAMPLES OF SIZE <br />INDICATED BELOW. <br />1. ACOUSTICAL PANEL: SET OF FULL-SIZE SAMPLES OF EACH TYPE, <br />COLOR, PATTERN, AND TEXTURE. <br />2. EXPOSED SUSPENSION SYSTEM MEMBERS, MOLDINGS, AND TRIM: <br />SET OF 12 INCH (300 MM) LONG SAMPLES OF EACH TYPE, FINISH, <br />AND COLOR. <br />D. QUALIFICATION DATA: FOR TESTING AGENCY. <br />E. FIELD QUALITY -CONTROL TEST REPORTS. <br />F. PRODUCT TEST REPORTS: BASED ON EVALUATION OF COMPREHENSIVE <br />TESTS PERFORMED BY A QUALIFIED TESTING AGENCY, FOR EACH <br />ACOUSTICAL PANEL CEILING. <br />G. MAINTENANCE DATA: FOR FINISHES TO INCLUDE IN MAINTENANCE <br />MANUALS. <br />1.3 QUALITY ASSURANCE <br />A. ACOUSTICAL PANEL QUALITY STANDARD: ASTM E 1264. <br />B. METAL SUSPENSION SYSTEM QUALITY STANDARD: ASTM C 635. <br />1.4 MATERIALS <br />A. ACOUSTICAL CEILING PANELS GENERAL: MUST BE CERTIFIED AS LOW <br />EMITTING. CERTIFICATION MUST BE BASED UPON THE CALIFORNIA <br />DEPARTMENT OF HEALTH SERVICES -STANDARD PRACTICE FOR THE <br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING <br />SMALL-SCALE ENVIRONMENTAL CHAMBERS", INCLUDING 2004 ADDENDA OR A <br />JURISDICTIONALLY RECOGNIZED STANDARD USING EQUIVALENT TESTING <br />METHODOLOGIES AND VOC THRESHOLDS. <br />B. ACOUSTICAL CEILING PANELS WASHABLE <br />1. CLASSIFICATION: TYPE IV, MINERAL BASE WITH MEMBRANE -FACED <br />OVERLAY; FORM 2, WATER FELTED; WITH VINYL OVERLAY ON FACE; <br />PATTERN G (SMOOTH). <br />2. COLOR: AS INDICATED ON DRAWINGS. <br />3. THICKNESS: 5/8 INCH (15 MM). <br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). <br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE <br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH <br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT <br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND <br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR <br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273 <br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21. <br />C. ACOUSTICAL CEILING PANELS TEXTURED: <br />1. CLASSIFICATION: TYPE III, MINERAL BASE WITH PAINTED FINISH; <br />FORM 2, WATER FELTED; PATTERN E (LIGHTLY TEXTURED). <br />2. COLOR: AS INDICATED ON DRAWINGS. <br />3. THICKNESS: 5/8 INCH (15 MM). <br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). <br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE <br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH <br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT <br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND <br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR <br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273 <br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21. <br />D. ACOUSTICAL CEILING PANELS PERFORATED: <br />1. CLASSIFICATION: TYPE III, MINERAL BASE WITH PAINTED FINISH; <br />FORM 2, WATER FELTED; PATTERN CE (PERFORATED, SMALL <br />HOLES AND LIGHTLY TEXTURED). <br />2. COLOR: AS INDICATED ON DRAWINGS. <br />3. THICKNESS: 3/4 INCH (15 MM). <br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). <br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE <br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH <br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT <br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND <br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR <br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273 <br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21. <br />E. METAL SUSPENSION SYSTEMS: <br />1. WIDE -FACE, CAPPED, DOUBLE -WEB STEEL: INTERMEDIATE DUTY. <br />F. METAL EDGE MOLDINGS AND TRIM: ROLL -FORMED SHEET METAL. <br />1.5 INSTALLATION <br />A. INSTALLATION: [ASTM C 6361 [UBC STANDARD 25-2]. <br />1.6 FIELD QUALITY CONTROL <br />A. TESTING: BY [OWNER] [CONTRACTOR] -ENGAGED AGENCY TO TEST <br />ACOUSTICAL PANEL CEILING HANGER FASTENERS. <br />END OF SECTION 095113 <br />FINISHES (CONTINUED) <br />SECTION 096400 - WOOD FLOORING <br />1.1 SUMMARY <br />A. [FACTORY-] [FIELD -]FINISHED WOOD FLOORING. <br />1.2 PERFORMANCE REQUIREMENTS <br />A. FLOORSCORE COMPLIANCE: COMPOSITE WOOD FLOORS SHALL COMPLY <br />WITH REQUIREMENTS OF FLOORSCORE STANDARD. <br />1.3 MATERIALS <br />A. ACCESSORIES: <br />1. WOOD FLOORING ADHESIVE: VOC LIMITS: 100 G/L. <br />END OF SECTION 096400 <br />SECTION 096516 - RESILIENT SHEET FLOORING <br />1.1 PRODUCTS <br />A. FLOORING SYSTEM: FLOORSCORE COMPLIANCE. <br />B. VINYL SHEET FLOORING: <br />1. BACKING: NONE, UNBACKED [NONFOAMED PLASTIC] [FOAMED <br />PLASTIC]. <br />2. SEAMLESS -INSTALLATION METHOD: HEAT WELDED. <br />C. RUBBER SHEET FLOORING: <br />1. BACKING: NONE, UNBACKED. <br />2. SEAMLESS -INSTALLATION METHOD: HEAT WELDED. <br />D. INSTALLATION MATERIALS: <br />E. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX -MODIFIED, <br />PORTLAND CEMENT BASED OR BLENDED HYDRAULIC -CEMENT -BASED <br />FORMULATION PROVIDED OR APPROVED BY RESILIENT SHEET FLOORING <br />MANUFACTURER FOR APPLICATIONS INDICATED. <br />F. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY FLOORING AND <br />ADHESIVE MANUFACTURERS TO SUIT RESILIENT SHEET FLOORING AND <br />SUBSTRATE CONDITIONS INDICATED. <br />1. VINYL SHEET ADHESIVES SHALL HAVE A VOC CONTENT OF 50 G/L <br />OR LESS. <br />2. RUBBER SHEET ADHESIVES SHALL HAVE A VOC CONTENT OF 60 G/L <br />OR LESS. <br />G. INTEGRAL -FLASH -COVE -BASE ACCESSORIES: <br />1. COVE STRIP: 1 INCH (25 MM) RADIUS PROVIDED OR APPROVED BY <br />RESILIENT SHEET FLOORING MANUFACTURER. <br />2. CAP STRIP: [SQUARE METAL, VINYL, OR RUBBER CAP] [TAPERED <br />VINYL CAP] <INSERT REQUIREMENTS> PROVIDED OR APPROVED BY <br />RESILIENT SHEET FLOORING MANUFACTURER. <br />3. FLOOR POLISH: PROVIDE PROTECTIVE, LIQUID FLOOR -POLISH <br />PRODUCTS RECOMMENDED BY RESILIENT SHEET FLOORING <br />MANUFACTURER. <br />END OF SECTION 096516 <br />SECTION 097200 - WALL COVERINGS <br />1.1 SUMMARY <br />A. VINYL AND WOVEN GLASS -FIBER WALL COVERING. <br />1.2 MATERIALS <br />A. ADHESIVE: MILDEW -RESISTANT, NONSTAINING, STRIPPABLE ADHESIVE, FOR <br />USE WITH SPECIFIC WALL COVERING AND SUBSTRATE APPLICATION, AS <br />RECOMMENDED IN WRITING BY WALL -COVERING MANUFACTURER, AND WITH <br />A VOC CONTENT OF 50 G/L OR LESS WHEN CALCULATED ACCORDING TO <br />40 CFR 59, SUBPART D (EPA METHOD 24). <br />1.3 INSTALLATION <br />A. INSTALL STRIPS IN SAME ORDER AS CUT FROM ROLL. <br />END OF SECTION 097200 <br />SECTION 099123 - INTERIOR PAINTING <br />1.1 SUMMARY <br />A. SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON <br />INTERIOR SUBSTRATES. <br />1.2 SUBMITTALS <br />A. SAMPLES FOR VERIFICATION: <br />1. FOR EACH NON-STANDARD LATEX TOPCOAT COLOR AND GLOSS <br />INDICATED. <br />2. FOR EACH TYPE OF NON-STANDARD PAINT SYSTEM AND IN EACH <br />COLOR AND GLOSS OF TOPCOAT INDICATED. <br />1.3 QUALITY ASSURANCE <br />A. QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI <br />ARCHITECTURAL PAINTING SPECIFICATION MANUAL." <br />B. MOCKUPS FOR EACH COLOR AND FINISH. <br />1.4 GENERAL <br />A. VOC CONTENT: PRODUCTS SHALL COMPLY WITH VOC LIMITS OF <br />AUTHORITIES HAVING JURISDICTION [AND, FOR INTERIOR PAINTS AND <br />COATINGS APPLIED AT PROJECT SITE, THE FOLLOWING VOC LIMITS, <br />EXCLUSIVE OF COLORANTS ADDED TO A TINT BASE, WHEN CALCULATED <br />ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24)]. <br />1. FLAT PAINTS AND COATINGS: 50 G/L. <br />2. NONFLAT PAINTS AND COATINGS: 150 G/L. <br />3. DRY -FOG COATINGS: 400 G/L. <br />4. PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L. <br />5. ANTICORROSIVE AND ANTIRUST PAINTS APPLIED TO FERROUS <br />METALS: 250 G/L. <br />6. ZINC -RICH INDUSTRIAL MAINTENANCE PRIMERS: 340 G/L. <br />7. PRETREATMENT WASH PRIMERS: 420 G/L. <br />8. FLOOR COATINGS: 100 G/L. <br />9. SHELLACS, CLEAR: 730 G/L. <br />10. SHELLACS, PIGMENTED: 550 G/L. <br />1.5 INTERIOR PAINTING SCHEDULE <br />A. STEEL SUBSTRATES: <br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM: <br />a. PRIME COAT: PRIMER, RUST -INHIBITIVE, WATER BASED. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />B. GALVANIZED -METAL SUBSTRATES: <br />1. INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: <br />a. PRIME COAT: PRIMER, GALVANIZED, WATER BASED. <br />b. TOPCOAT: LATEX, INTERIOR, INSTITUTIONAL LOW <br />ODOR/VOC, (GLOSS LEVEL AS INDICATED IN PAINT <br />SCHEDULE). <br />C. WOOD SUBSTRATES: <br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM: <br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />D. GYPSUM BOARD SUBSTRATES: <br />1. INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: <br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />E. HIGH -IMPACT GYPSUM BOARD SUBSTRATES: <br />1. HIGH-PERFORMANCE ARCH ITEC rURAL LATEX SYSTEM: <br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />F. PLASTER SUBSTRATES: <br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM: <br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />G. ACOUSTICAL CEILING TILE: <br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM: <br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER. <br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR <br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). <br />END OF SECTION 099123 <br />FINISHES (CONTINUED <br />SECTION 09930 - WOOD STAINS AND TRANSPARENT FINISHES <br />1.1 SUMMARY <br />A. SURFACE PREPARATION AND APPLICATION OF WOOD FINISHES ON <br />[EXTERIOR] [AND] [INTERIOR] SUBSTRATES. <br />1.2 SUBMITTALS <br />A. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF FINISH SYSTEM AND IN <br />EACH COLOR AND GLOSS OF FINISH INDICATED. <br />1.3 QUALITY ASSURANCE <br />A. QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI <br />ARCHITECTURAL PAINTING SPECIFICATION MANUAL." <br />1.4 GENERAL <br />A. CHEMICAL COMPONENTS OF FIELD -APPLIED INTERIOR PAINTS AND COATINGS: <br />1. VOC LIMITS: <br />a. CLEAR WOOD FINISHES, VARNISHES: VOC NOT MORE THAN <br />350 G/L. <br />b. SHELLACS, CLEAR: VOC NOT MORE THAN 730 G/L. <br />c. STAINS: VOC NOT MORE THAN 250 G/L. <br />d. PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L. <br />e. FIRE RETARDANT COATINGS, CLEAR: 650 G/L. <br />f. FIRE RETARDANT COATINGS, PIGMENTED: 350 G/L. <br />1.5 EXTERIOR WOOD -FINISH -SYSTEM SCHEDULE <br />A. SOLID -COLOR LATEX STAIN SYSTEM: MPI EXT 6.3K. <br />1. PRIME COAT: PRIMER, LATEX FOR EXTERIOR WOOD. <br />2. INTERMEDIATE COAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE, <br />MATCHING TOPCOAT. <br />3. TOPCOAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE. <br />B. SEMITRANSPARENT STAIN SYSTEM: MPI EXT 6.3D. <br />1. TWO STAIN COATS: EXTERIOR SEMITRANSPARENT LATEX STAIN. <br />1.6 INTERIOR WOOD -FINISH -SYSTEM SCHEDULE <br />A. SEMITRANSPARENT STAIN SYSTEM: <br />1. PRIME COAT: STAIN, SEMI -TRANSPARENT, MATCHING TOPCOAT. <br />2. TOPCOAT: STAIN, SEMI -TRANSPARENT, FOR INTERIOR WOOD. <br />B. WATER -BASED VARNISH SYSTEM: <br />a. PRIME COAT: WATER -BASED VARNISH MATCHING TOPCOAT. <br />b. INTERMEDIATE COAT: WATER -BASED VARNISH MATCHING TOPCOAT. <br />c. TOPCOAT: VARNISH, WATER BASED, CLEAR. <br />C. WATER -BASED FIRE RETARDANT SYSTEM: <br />a. TOPCOAT: FIRE RETARDANT COATING, CLEAR. <br />1. CLASS A FLAME SPREAD AND SMOKE -DEVELOPED INDEX PER <br />ASTM E 84. <br />END OF SECTION 09930 <br />STARBUCKS <br />2401 UTAH AVENUE SOUTH <br />SEATTLE, WASHINGTON 98134 <br />(206) 318-1575 <br />THESE DRAWINGS AND SPECIFICATIONS ARE <br />CONFIDENTIAL AND SHALL REMAIN THE SOLE <br />PROPERTY OF STARBUCKS CORPORATION, <br />WHICH IS THE OWNER OF THE COPYRIGHT IN <br />THIS WORK. THEY SHALL NOT BE <br />REPRODUCED (IN WHOLE OR IN PART), SHARED <br />WITH THIRD PARTIES OR USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS TO THIS <br />PROJECT WITHOUT THE PRIOR WRITTEN <br />CONSENT OF STARBUCKS CORPORATION. <br />THESE DRAWINGS AND SPECIFICATIONS ARE <br />INTENDED TO EXPRESS DESIGN INTENT FOR A <br />PROTOTYPICAL STARBUCKS STORE (WHICH IS <br />SUBJECT TO CHANGE AT ANYTIME) AND DO <br />NOT REFLECT ACTUAL SITE CONDITIONS. <br />NEITHER PARTY SHALL HAVE ANY OBLIGATION <br />NOR LIABILITY TO THE OTHER (EXCEPT STATED <br />ABOVE) UNTIL A WRITTEN AGREEMENT IS <br />FULLY EXECUTED BY BOTH PARTIES. <br />STARBUCKS TEMPLATE VERSION Q018.01.26 <br />700 W. Pete Rose Way, Suite 460 Donald J. Rethman <br />Cincinnati, OH 45203 Architect In Charge <br />Tel: (513) 421-2210 License: AR0017303 <br />I700 W. Pete Rose Way, Suite 460 Timothy L Raberding, PE I <br />Cincinnati, OH 45203 Professional Engineer <br />Tel: (5131 421-2210 License: 62076 <br />W <br />Q <br />Z <br />U <br />W <br />w <br />0- <br />zNi <br />r <br />0 <br />M <br />W <br />Z) <br />OF P40 UN 2 5 2018 <br />rittUU; 7303 ' <br />07 <br />LU <br />Q <br />U <br />W <br />w <br />a <br />J <br />m <br />J <br />fQ <br />V <br />0 <br />V_ <br />0 <br />r <br />M <br />M <br />LL <br />J_ <br />N <br />(STORE #: 56350 I <br />PROJECT #: 81186-001 <br />ISSUE DATE: 06/22/18 <br />DESIGN PROGRAM ROMINA VIGNOLO <br />MANAGER: <br />LEEDO AP: <br />PRODUCTION DESIGNER: MICHAEL.B.SARKA <br />-CHECKED BY7 M.MCCAUGHEY <br />Revision Schedule <br />Rev Date By Description <br />SHEET TITLE: <br />CONSTRUCTION <br />SPECIFICATIONS <br />SCALE: NO SCALE <br />SHEET NUMBER: <br />G-011 <br />