c
<br />c
<br />m
<br />O
<br />EI
<br />ti
<br />O
<br />NI
<br />J
<br />LL
<br />t
<br />O
<br />ca
<br />06
<br />O
<br />co
<br />YI
<br />U
<br />E.
<br />M
<br />U)
<br />C:
<br />N
<br />U
<br />O
<br />0
<br />c
<br />C
<br />C
<br />ca
<br />O
<br />E.
<br />N
<br />CD
<br />Z)
<br />�`
<br />b
<br />N
<br />co
<br />O
<br />T_
<br />»0
<br />T_
<br />O
<br />N
<br />u7
<br />N
<br />O
<br />FINISHES
<br />SECTION 09216 - NON -LOAD -BEARING STEEL FRAMING
<br />1.1 SUMMARY
<br />A. NON -LOAD -BEARING STEEL FRAMING MEMBERS FOR INTERIOR FRAMING
<br />SYSTEMS.
<br />1.2 MATERIALS
<br />A. STEEL FRAMING FOR FRAMED ASSEMBLIES:
<br />B. FRAMING MEMBERS, GENERAL: COMPLY WITH ASTM C 754 FOR CONDITIONS
<br />INDICATED.
<br />1. STEEL SHEET COMPONENTS: COMPLY WITH ASTM C 645
<br />REQUIREMENTS FOR METAL, UNLESS OTHERWISE INDICATED.
<br />2. PROTECTIVE COATING: COATING WITH EQUIVALENT CORROSION
<br />RESISTANCE OF ASTM A 653/A 653M, G40 (Z120), HOT -DIP
<br />GALVANIZED, UNLESS OTHERWISE INDICATED.
<br />1.3 STEEL FRAMING FOR FRAMED ASSEMBLIES
<br />A. SALVAGED MATERIAL: USE SALVAGED FRAMING MATERIALS WHENEVER
<br />AVAILABLE.
<br />B. STEEL STUDS AND RUNNERS: ASTM C 645.
<br />1. MINIMUM BASE -METAL THICKNESS: 0.033 INCH (0.84 MM) UNLESS
<br />OTHERWISE INDICATED ON DRAWINGS.
<br />2. DEPTH: AS INDICATED ON DRAWINGS.
<br />C. DIMPLED STEEL STUDS AND RUNNERS:
<br />1. MINIMUM BASE -METAL THICKNESS: 0.025 INCH (0.64 MM).
<br />2. DEPTH: AS INDICATED ON DRAWINGS.
<br />D. SLIP -TYPE HEAD JOINTS: WHERE INDICATED, PROVIDE ONE OF THE
<br />FOLLOWING:
<br />1. SINGLE LONG -LEG RUNNER SYSTEM: ASTM C 645 TOP RUNNER
<br />WITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT LESS
<br />THAN INDICATED FOR STUDS, INSTALLED WITH STUDS FRICTION FIT
<br />INTO TOP RUNNER AND WITH CONTINUOUS BRIDGING LOCATED
<br />WITHIN 12 INCHES (305 MM) OF THE TOP OF STUDS TO PROVIDE
<br />LATERAL BRACING.
<br />2. DOUBLE -RUNNER SYSTEM: ASTM C 645 TOP RUNNERS, INSIDE
<br />RUNNER WITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT
<br />LESS THAN INDICATED FOR STUDS AND FASTENED TO STUDS, AND
<br />OUTER RUNNER SIZED TO FRICTION FIT INSIDE RUNNER.
<br />3. DEFLECTION TRACK: STEEL SHEET TOP RUNNER MANUFACTURED
<br />TO PREVENT CRACKING OF FINISHES APPLIED TO INTERIOR
<br />PARTITION FRAMING RESULTING FROM DEFLECTION OF STRUCTURE
<br />ABOVE; IN THICKNESS NOT LESS THAN INDICATED FOR STUDS AND
<br />IN WIDTH TO ACCOMMODATE DEPTH OF STUDS.
<br />E. COLD -ROLLED CHANNEL BRIDGING: 0.0538 INCH (1.37 MM) BARE -STEEL
<br />THICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES.
<br />1. DEPTH: 1-1/2 INCHES (38.1 MM).
<br />2. CLIP ANGLE: NOT LESS THAN 1-1/2 BY 1-1/2 INCHES (38.1 BY
<br />38.1 MM), 0.068 INCH (1.73 MM) THICK, GALVANIZED STEEL.
<br />F. HAT -SHAPED, RIGID FURRING CHANNELS: ASTM C 645.
<br />1. MINIMUM BASE METAL THICKNESS: AS INDICATED ON DRAWINGS.
<br />2. DEPTH: AS INDICATED ON DRAWINGS.
<br />G. COLD -ROLLED FURRING CHANNELS: 0.0538 INCH (1.37 MM) BARE -STEEL
<br />THICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES.
<br />1. DEPTH: AS INDICATED ON DRAWINGS.
<br />2. FURRING BRACKETS: ADJUSTABLE, CORRUGATED -EDGE TYPE OF
<br />STEEL SHEET WITH MINIMUM BARE -STEEL THICKNESS OF
<br />0.0312 INCH (0.79 MM).
<br />3. TIE WIRE: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT
<br />TEMPER, 0.0625 INCH (1.59 MM) DIAMETER WIRE, OR DOUBLE
<br />STRAND OF 0.0475 INCH (1.21 MM) DIAMETER WIRE.
<br />H. Z-SHAPED FURRING: WITH SLOTTED OR NONSLOTTED WEB, FACE FLANGE
<br />OF 1-1/4 INCHES (31.8 MM), WALL ATTACHMENT FLANGE OF 7/8 INCH
<br />(22.2 MM), MINIMUM BARE -METAL THICKNESS OF 0.0179 INCH (0.45 MM), AND
<br />DEPTH REQUIRED TO FIT INSULATION THICKNESS INDICATED.
<br />END OF SECTION 09216
<br />SECTION 092900 - GYPSUM BOARD
<br />1.1 SUMMARY
<br />A. INTERIOR GYPSUM BOARD.
<br />B. TILE BACKING PANELS.
<br />1.2 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
<br />B. SAMPLES: FOR THE FOLLOWING PRODUCTS:
<br />1. TEXTURED FINISHES: MANUFACTURER'S STANDARD SIZE FOR EACH
<br />TEXTURED FINISH INDICATED AND ON SAME BACKING INDICATED
<br />FOR WORK.
<br />1.3 MATERIALS
<br />A. INTERIOR GYPSUM BOARD:
<br />1. GENERAL: COMPLYING WITH ASTM C 36/C 36M OR
<br />ASTM C 1396/C 1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD
<br />INDICATED AND WHICHEVER IS MORE STRINGENT.
<br />a. MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION
<br />MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF
<br />HEALTH SERVICES' "STANDARD PRACTICE FOR THE
<br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM
<br />VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL
<br />CHAMBERS", INCLUDING 2004 ADDENDA OR A
<br />JURISDICTIONALLY RECOGNIZED STANDARD USING
<br />VALENT TESTING METHODOLOGIES AND VOC THRESHOLDS.
<br />2. TYPE X:
<br />a. THICKNESS: 5/8 INCH (15.9 MM).
<br />b. LONG EDGES: TAPERED.
<br />3. MOISTURE- AND MOLD -RESISTANT TYPE: WITH MOISTURE- AND
<br />MOLD -RESISTANT CORE AND SURFACES.
<br />a. CORE: 5/8 INCH (15.9 MM), TYPE X.
<br />b. LONG EDGES: TAPERED.
<br />c. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED
<br />ACCORDING TO ASTM D 3274.
<br />B. TILE -BACKING PANELS:
<br />1. GLASS -MAT, WATER-RESISTANT BACKING BOARD:
<br />ASTM C 1178/C 1178M, WITH MANUFACTURER'S STANDARD EDGES.
<br />a. MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION
<br />MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF
<br />HEALTH SERVICES"'STANDARD PRACTICE FOR THE
<br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM
<br />VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL
<br />CHAMBERS", INCLUDING 2004 ADDENDA OR A
<br />JURISDICTIONALLY RECOGNIZED STANDARD USING
<br />EQUIVALENT TESTING METHODOLOGIES AND VOC
<br />THRESHOLDS.
<br />b. CORE: 5/8 INCH (15.9 MM), TYPE X.
<br />c. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED
<br />ACCORDING TO ASTM D 3274.
<br />2. CEMENTITIOUS BACKER UNITS: ANSI A118.9 AND
<br />ASTM C 1288 OR 1325, WITH MANUFACTURER'S STANDARD EDGES.
<br />a. THICKNESS: [1/4 INCH (6.4 MM)] [AS INDICATED].
<br />b. MOLD RESISTANCE: ASTM D 3273, SCORE OF 10 AS RATED
<br />ACCORDING TO ASTM D 3274.
<br />C. TRIM ACCESSORIES:
<br />a. INTERIOR: CORNERBEAD.
<br />END OF SECTION 092900
<br />FINISHES (CONTINUED
<br />SECTION 093000 - CERAMIC TILE
<br />1.1 SUMMARY
<br />A. PAVER, GLAZED, AND WALL TILE.
<br />B. WATERPROOF MEMBRANE FOR THIN -SET TILE INSTALLATIONS.
<br />C. METAL EDGE STRIPS INSTALLED AS PART OF TILE INSTALLATIONS.
<br />1.2 QUALITY ASSURANCE
<br />A. MOCKUPS FOR EACH FORM OF CONSTRUCTION.
<br />1.3 MATERIALS
<br />A. GLAZED WALL TILE TRIM SHAPES: COVED BASE, BULLNOSE CAP.
<br />B. THRESHOLDS: SATIN ANODIZED ALUMINUM THRESHOLDS AND TRANSITION
<br />STRIPS.
<br />1. BEVEL EDGES AT 1:2 SLOPE, WITH LOWER EDGE OF BEVEL ALIGNED
<br />WITH OR UP TO 1/16 INCH (1.5 MM) ABOVE ADJACENT FLOOR
<br />SURFACE. FINISH BEVEL TO MATCH TOP SURFACE OF THRESHOLD.
<br />LIMIT HEIGHT OF THRESHOLD TO 1/2 INCH (12.7 MM) OR LESS ABOVE
<br />ADJACENT FLOOR SURFACE.
<br />C. MORTAR: LATEX-PORTLAND CEMENT
<br />D. ELASTOMERIC SEALANTS: ONE -PART, MILDEW -RESISTANT SILICONE.
<br />1. SEALANTS SHALL HAVE A VOC CONTENT OF [250] <INSERT VALUE>
<br />G/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59,
<br />SUBPART D (EPA METHOD 24).
<br />1.4 FLOOR TILE INSTALLATION SCHEDULE
<br />A. INTERIOR FLOORS ON CONCRETE: THIN -SET MORTAR.
<br />1. TILE TYPE: UNGLAZED PAVER TILE.
<br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT.
<br />3. GROUT: POLYMER -MODIFIED UNSANDED 100% SOLIDS EPDXY
<br />NON -SAGGING GROUT.
<br />B. INTERIOR FLOORS ON [WATERPROOF] [CRACK -SUPPRESSION] MEMBRANE
<br />OVER CONCRETE AND WOOD: THIN -SET MORTAR.
<br />1. TILE TYPE: UNGLAZED PAVER TILE.
<br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT.
<br />3. GROUT: POLYMER -MODIFIED UNSANDED 100% SOLIDS EPDXY
<br />NON -SAGGING GROUT.
<br />1.5 WALL TILE INSTALLATION SCHEDULE
<br />A. INTERIOR WALLS OVER GLASS -MAT WATER-RESISTANT BACKER BOARD OR
<br />CEMENTITIOUS BACKER UNITS: THIN -SET MORTAR.
<br />1. TILE TYPE: [UNGLAZED CERAMIC MOSAIC] [GLAZED CERAMIC
<br />MOSAIC] [GLAZED WALL] TILE.
<br />2. MORTAR: LATEX- PORTLAND CEMENT MORTAR.
<br />3. GROUT: POLYMER -MODIFIED UNSANDED GROUT.
<br />END OF SECTION 093000
<br />SECTION 095113 - ACOUSTICAL PANEL CEILINGS
<br />1.1 SUMMARY
<br />A. ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS.
<br />1.2 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
<br />B. COORDINATION DRAWINGS: REFLECTED CEILING PLANS, DRAWN TO SCALE,
<br />ON WHICH THE FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH
<br />EACH OTHER, BASED ON INPUT FROM INSTALLERS OF THE ITEMS
<br />INVOLVED:
<br />1. CEILING SUSPENSION SYSTEM MEMBERS.
<br />2. METHOD OF ATTACHING HANGERS TO BUILDING STRUCTURE.
<br />3. CEILING -MOUNTED ITEMS INCLUDING LIGHTING FIXTURES,
<br />DIFFUSERS, GRILLES, SPEAKERS, SPRINKLERS, ACCESS PANELS,
<br />AND SPECIAL MOLDINGS.
<br />C. SAMPLES FOR VERIFICATION: FOR EACH COMPONENT INDICATED AND FOR
<br />EACH EXPOSED FINISH REQUIRED, PREPARED ON SAMPLES OF SIZE
<br />INDICATED BELOW.
<br />1. ACOUSTICAL PANEL: SET OF FULL-SIZE SAMPLES OF EACH TYPE,
<br />COLOR, PATTERN, AND TEXTURE.
<br />2. EXPOSED SUSPENSION SYSTEM MEMBERS, MOLDINGS, AND TRIM:
<br />SET OF 12 INCH (300 MM) LONG SAMPLES OF EACH TYPE, FINISH,
<br />AND COLOR.
<br />D. QUALIFICATION DATA: FOR TESTING AGENCY.
<br />E. FIELD QUALITY -CONTROL TEST REPORTS.
<br />F. PRODUCT TEST REPORTS: BASED ON EVALUATION OF COMPREHENSIVE
<br />TESTS PERFORMED BY A QUALIFIED TESTING AGENCY, FOR EACH
<br />ACOUSTICAL PANEL CEILING.
<br />G. MAINTENANCE DATA: FOR FINISHES TO INCLUDE IN MAINTENANCE
<br />MANUALS.
<br />1.3 QUALITY ASSURANCE
<br />A. ACOUSTICAL PANEL QUALITY STANDARD: ASTM E 1264.
<br />B. METAL SUSPENSION SYSTEM QUALITY STANDARD: ASTM C 635.
<br />1.4 MATERIALS
<br />A. ACOUSTICAL CEILING PANELS GENERAL: MUST BE CERTIFIED AS LOW
<br />EMITTING. CERTIFICATION MUST BE BASED UPON THE CALIFORNIA
<br />DEPARTMENT OF HEALTH SERVICES -STANDARD PRACTICE FOR THE
<br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING
<br />SMALL-SCALE ENVIRONMENTAL CHAMBERS", INCLUDING 2004 ADDENDA OR A
<br />JURISDICTIONALLY RECOGNIZED STANDARD USING EQUIVALENT TESTING
<br />METHODOLOGIES AND VOC THRESHOLDS.
<br />B. ACOUSTICAL CEILING PANELS WASHABLE
<br />1. CLASSIFICATION: TYPE IV, MINERAL BASE WITH MEMBRANE -FACED
<br />OVERLAY; FORM 2, WATER FELTED; WITH VINYL OVERLAY ON FACE;
<br />PATTERN G (SMOOTH).
<br />2. COLOR: AS INDICATED ON DRAWINGS.
<br />3. THICKNESS: 5/8 INCH (15 MM).
<br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM).
<br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE
<br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH
<br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT
<br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND
<br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR
<br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273
<br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21.
<br />C. ACOUSTICAL CEILING PANELS TEXTURED:
<br />1. CLASSIFICATION: TYPE III, MINERAL BASE WITH PAINTED FINISH;
<br />FORM 2, WATER FELTED; PATTERN E (LIGHTLY TEXTURED).
<br />2. COLOR: AS INDICATED ON DRAWINGS.
<br />3. THICKNESS: 5/8 INCH (15 MM).
<br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM).
<br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE
<br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH
<br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT
<br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND
<br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR
<br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273
<br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21.
<br />D. ACOUSTICAL CEILING PANELS PERFORATED:
<br />1. CLASSIFICATION: TYPE III, MINERAL BASE WITH PAINTED FINISH;
<br />FORM 2, WATER FELTED; PATTERN CE (PERFORATED, SMALL
<br />HOLES AND LIGHTLY TEXTURED).
<br />2. COLOR: AS INDICATED ON DRAWINGS.
<br />3. THICKNESS: 3/4 INCH (15 MM).
<br />4. MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM).
<br />5. BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE
<br />TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH
<br />MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT
<br />INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM -POSITIVE AND
<br />GRAM -NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR
<br />BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTM D 3273
<br />AND EVALUATED ACCORDING TO ASTM D 3274 OR ASTM G 21.
<br />E. METAL SUSPENSION SYSTEMS:
<br />1. WIDE -FACE, CAPPED, DOUBLE -WEB STEEL: INTERMEDIATE DUTY.
<br />F. METAL EDGE MOLDINGS AND TRIM: ROLL -FORMED SHEET METAL.
<br />1.5 INSTALLATION
<br />A. INSTALLATION: [ASTM C 6361 [UBC STANDARD 25-2].
<br />1.6 FIELD QUALITY CONTROL
<br />A. TESTING: BY [OWNER] [CONTRACTOR] -ENGAGED AGENCY TO TEST
<br />ACOUSTICAL PANEL CEILING HANGER FASTENERS.
<br />END OF SECTION 095113
<br />FINISHES (CONTINUED)
<br />SECTION 096400 - WOOD FLOORING
<br />1.1 SUMMARY
<br />A. [FACTORY-] [FIELD -]FINISHED WOOD FLOORING.
<br />1.2 PERFORMANCE REQUIREMENTS
<br />A. FLOORSCORE COMPLIANCE: COMPOSITE WOOD FLOORS SHALL COMPLY
<br />WITH REQUIREMENTS OF FLOORSCORE STANDARD.
<br />1.3 MATERIALS
<br />A. ACCESSORIES:
<br />1. WOOD FLOORING ADHESIVE: VOC LIMITS: 100 G/L.
<br />END OF SECTION 096400
<br />SECTION 096516 - RESILIENT SHEET FLOORING
<br />1.1 PRODUCTS
<br />A. FLOORING SYSTEM: FLOORSCORE COMPLIANCE.
<br />B. VINYL SHEET FLOORING:
<br />1. BACKING: NONE, UNBACKED [NONFOAMED PLASTIC] [FOAMED
<br />PLASTIC].
<br />2. SEAMLESS -INSTALLATION METHOD: HEAT WELDED.
<br />C. RUBBER SHEET FLOORING:
<br />1. BACKING: NONE, UNBACKED.
<br />2. SEAMLESS -INSTALLATION METHOD: HEAT WELDED.
<br />D. INSTALLATION MATERIALS:
<br />E. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX -MODIFIED,
<br />PORTLAND CEMENT BASED OR BLENDED HYDRAULIC -CEMENT -BASED
<br />FORMULATION PROVIDED OR APPROVED BY RESILIENT SHEET FLOORING
<br />MANUFACTURER FOR APPLICATIONS INDICATED.
<br />F. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY FLOORING AND
<br />ADHESIVE MANUFACTURERS TO SUIT RESILIENT SHEET FLOORING AND
<br />SUBSTRATE CONDITIONS INDICATED.
<br />1. VINYL SHEET ADHESIVES SHALL HAVE A VOC CONTENT OF 50 G/L
<br />OR LESS.
<br />2. RUBBER SHEET ADHESIVES SHALL HAVE A VOC CONTENT OF 60 G/L
<br />OR LESS.
<br />G. INTEGRAL -FLASH -COVE -BASE ACCESSORIES:
<br />1. COVE STRIP: 1 INCH (25 MM) RADIUS PROVIDED OR APPROVED BY
<br />RESILIENT SHEET FLOORING MANUFACTURER.
<br />2. CAP STRIP: [SQUARE METAL, VINYL, OR RUBBER CAP] [TAPERED
<br />VINYL CAP] <INSERT REQUIREMENTS> PROVIDED OR APPROVED BY
<br />RESILIENT SHEET FLOORING MANUFACTURER.
<br />3. FLOOR POLISH: PROVIDE PROTECTIVE, LIQUID FLOOR -POLISH
<br />PRODUCTS RECOMMENDED BY RESILIENT SHEET FLOORING
<br />MANUFACTURER.
<br />END OF SECTION 096516
<br />SECTION 097200 - WALL COVERINGS
<br />1.1 SUMMARY
<br />A. VINYL AND WOVEN GLASS -FIBER WALL COVERING.
<br />1.2 MATERIALS
<br />A. ADHESIVE: MILDEW -RESISTANT, NONSTAINING, STRIPPABLE ADHESIVE, FOR
<br />USE WITH SPECIFIC WALL COVERING AND SUBSTRATE APPLICATION, AS
<br />RECOMMENDED IN WRITING BY WALL -COVERING MANUFACTURER, AND WITH
<br />A VOC CONTENT OF 50 G/L OR LESS WHEN CALCULATED ACCORDING TO
<br />40 CFR 59, SUBPART D (EPA METHOD 24).
<br />1.3 INSTALLATION
<br />A. INSTALL STRIPS IN SAME ORDER AS CUT FROM ROLL.
<br />END OF SECTION 097200
<br />SECTION 099123 - INTERIOR PAINTING
<br />1.1 SUMMARY
<br />A. SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON
<br />INTERIOR SUBSTRATES.
<br />1.2 SUBMITTALS
<br />A. SAMPLES FOR VERIFICATION:
<br />1. FOR EACH NON-STANDARD LATEX TOPCOAT COLOR AND GLOSS
<br />INDICATED.
<br />2. FOR EACH TYPE OF NON-STANDARD PAINT SYSTEM AND IN EACH
<br />COLOR AND GLOSS OF TOPCOAT INDICATED.
<br />1.3 QUALITY ASSURANCE
<br />A. QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI
<br />ARCHITECTURAL PAINTING SPECIFICATION MANUAL."
<br />B. MOCKUPS FOR EACH COLOR AND FINISH.
<br />1.4 GENERAL
<br />A. VOC CONTENT: PRODUCTS SHALL COMPLY WITH VOC LIMITS OF
<br />AUTHORITIES HAVING JURISDICTION [AND, FOR INTERIOR PAINTS AND
<br />COATINGS APPLIED AT PROJECT SITE, THE FOLLOWING VOC LIMITS,
<br />EXCLUSIVE OF COLORANTS ADDED TO A TINT BASE, WHEN CALCULATED
<br />ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24)].
<br />1. FLAT PAINTS AND COATINGS: 50 G/L.
<br />2. NONFLAT PAINTS AND COATINGS: 150 G/L.
<br />3. DRY -FOG COATINGS: 400 G/L.
<br />4. PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L.
<br />5. ANTICORROSIVE AND ANTIRUST PAINTS APPLIED TO FERROUS
<br />METALS: 250 G/L.
<br />6. ZINC -RICH INDUSTRIAL MAINTENANCE PRIMERS: 340 G/L.
<br />7. PRETREATMENT WASH PRIMERS: 420 G/L.
<br />8. FLOOR COATINGS: 100 G/L.
<br />9. SHELLACS, CLEAR: 730 G/L.
<br />10. SHELLACS, PIGMENTED: 550 G/L.
<br />1.5 INTERIOR PAINTING SCHEDULE
<br />A. STEEL SUBSTRATES:
<br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM:
<br />a. PRIME COAT: PRIMER, RUST -INHIBITIVE, WATER BASED.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />B. GALVANIZED -METAL SUBSTRATES:
<br />1. INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM:
<br />a. PRIME COAT: PRIMER, GALVANIZED, WATER BASED.
<br />b. TOPCOAT: LATEX, INTERIOR, INSTITUTIONAL LOW
<br />ODOR/VOC, (GLOSS LEVEL AS INDICATED IN PAINT
<br />SCHEDULE).
<br />C. WOOD SUBSTRATES:
<br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM:
<br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />D. GYPSUM BOARD SUBSTRATES:
<br />1. INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM:
<br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />E. HIGH -IMPACT GYPSUM BOARD SUBSTRATES:
<br />1. HIGH-PERFORMANCE ARCH ITEC rURAL LATEX SYSTEM:
<br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />F. PLASTER SUBSTRATES:
<br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM:
<br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODORNOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />G. ACOUSTICAL CEILING TILE:
<br />1. INSTITUTIONAL LOW-ODORNOC LATEX SYSTEM:
<br />a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
<br />b. TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR
<br />LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE).
<br />END OF SECTION 099123
<br />FINISHES (CONTINUED
<br />SECTION 09930 - WOOD STAINS AND TRANSPARENT FINISHES
<br />1.1 SUMMARY
<br />A. SURFACE PREPARATION AND APPLICATION OF WOOD FINISHES ON
<br />[EXTERIOR] [AND] [INTERIOR] SUBSTRATES.
<br />1.2 SUBMITTALS
<br />A. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF FINISH SYSTEM AND IN
<br />EACH COLOR AND GLOSS OF FINISH INDICATED.
<br />1.3 QUALITY ASSURANCE
<br />A. QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI
<br />ARCHITECTURAL PAINTING SPECIFICATION MANUAL."
<br />1.4 GENERAL
<br />A. CHEMICAL COMPONENTS OF FIELD -APPLIED INTERIOR PAINTS AND COATINGS:
<br />1. VOC LIMITS:
<br />a. CLEAR WOOD FINISHES, VARNISHES: VOC NOT MORE THAN
<br />350 G/L.
<br />b. SHELLACS, CLEAR: VOC NOT MORE THAN 730 G/L.
<br />c. STAINS: VOC NOT MORE THAN 250 G/L.
<br />d. PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L.
<br />e. FIRE RETARDANT COATINGS, CLEAR: 650 G/L.
<br />f. FIRE RETARDANT COATINGS, PIGMENTED: 350 G/L.
<br />1.5 EXTERIOR WOOD -FINISH -SYSTEM SCHEDULE
<br />A. SOLID -COLOR LATEX STAIN SYSTEM: MPI EXT 6.3K.
<br />1. PRIME COAT: PRIMER, LATEX FOR EXTERIOR WOOD.
<br />2. INTERMEDIATE COAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE,
<br />MATCHING TOPCOAT.
<br />3. TOPCOAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE.
<br />B. SEMITRANSPARENT STAIN SYSTEM: MPI EXT 6.3D.
<br />1. TWO STAIN COATS: EXTERIOR SEMITRANSPARENT LATEX STAIN.
<br />1.6 INTERIOR WOOD -FINISH -SYSTEM SCHEDULE
<br />A. SEMITRANSPARENT STAIN SYSTEM:
<br />1. PRIME COAT: STAIN, SEMI -TRANSPARENT, MATCHING TOPCOAT.
<br />2. TOPCOAT: STAIN, SEMI -TRANSPARENT, FOR INTERIOR WOOD.
<br />B. WATER -BASED VARNISH SYSTEM:
<br />a. PRIME COAT: WATER -BASED VARNISH MATCHING TOPCOAT.
<br />b. INTERMEDIATE COAT: WATER -BASED VARNISH MATCHING TOPCOAT.
<br />c. TOPCOAT: VARNISH, WATER BASED, CLEAR.
<br />C. WATER -BASED FIRE RETARDANT SYSTEM:
<br />a. TOPCOAT: FIRE RETARDANT COATING, CLEAR.
<br />1. CLASS A FLAME SPREAD AND SMOKE -DEVELOPED INDEX PER
<br />ASTM E 84.
<br />END OF SECTION 09930
<br />STARBUCKS
<br />2401 UTAH AVENUE SOUTH
<br />SEATTLE, WASHINGTON 98134
<br />(206) 318-1575
<br />THESE DRAWINGS AND SPECIFICATIONS ARE
<br />CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br />PROPERTY OF STARBUCKS CORPORATION,
<br />WHICH IS THE OWNER OF THE COPYRIGHT IN
<br />THIS WORK. THEY SHALL NOT BE
<br />REPRODUCED (IN WHOLE OR IN PART), SHARED
<br />WITH THIRD PARTIES OR USED IN ANY MANNER
<br />ON OTHER PROJECTS OR EXTENSIONS TO THIS
<br />PROJECT WITHOUT THE PRIOR WRITTEN
<br />CONSENT OF STARBUCKS CORPORATION.
<br />THESE DRAWINGS AND SPECIFICATIONS ARE
<br />INTENDED TO EXPRESS DESIGN INTENT FOR A
<br />PROTOTYPICAL STARBUCKS STORE (WHICH IS
<br />SUBJECT TO CHANGE AT ANYTIME) AND DO
<br />NOT REFLECT ACTUAL SITE CONDITIONS.
<br />NEITHER PARTY SHALL HAVE ANY OBLIGATION
<br />NOR LIABILITY TO THE OTHER (EXCEPT STATED
<br />ABOVE) UNTIL A WRITTEN AGREEMENT IS
<br />FULLY EXECUTED BY BOTH PARTIES.
<br />STARBUCKS TEMPLATE VERSION Q018.01.26
<br />700 W. Pete Rose Way, Suite 460 Donald J. Rethman
<br />Cincinnati, OH 45203 Architect In Charge
<br />Tel: (513) 421-2210 License: AR0017303
<br />I700 W. Pete Rose Way, Suite 460 Timothy L Raberding, PE I
<br />Cincinnati, OH 45203 Professional Engineer
<br />Tel: (5131 421-2210 License: 62076
<br />W
<br />Q
<br />Z
<br />U
<br />W
<br />w
<br />0-
<br />zNi
<br />r
<br />0
<br />M
<br />W
<br />Z)
<br />OF P40 UN 2 5 2018
<br />rittUU; 7303 '
<br />07
<br />LU
<br />Q
<br />U
<br />W
<br />w
<br />a
<br />J
<br />m
<br />J
<br />fQ
<br />V
<br />0
<br />V_
<br />0
<br />r
<br />M
<br />M
<br />LL
<br />J_
<br />N
<br />(STORE #: 56350 I
<br />PROJECT #: 81186-001
<br />ISSUE DATE: 06/22/18
<br />DESIGN PROGRAM ROMINA VIGNOLO
<br />MANAGER:
<br />LEEDO AP:
<br />PRODUCTION DESIGNER: MICHAEL.B.SARKA
<br />-CHECKED BY7 M.MCCAUGHEY
<br />Revision Schedule
<br />Rev Date By Description
<br />SHEET TITLE:
<br />CONSTRUCTION
<br />SPECIFICATIONS
<br />SCALE: NO SCALE
<br />SHEET NUMBER:
<br />G-011
<br />
|