Laserfiche WebLink
C <br />c <br />0 <br />EI <br />ti <br />O <br />NI <br />J <br />LL. <br />N <br />cc <br />06 <br />0 <br />M <br />�I <br />Y <br />U <br />2 <br />M <br />U) <br />C: <br />N <br />0 <br />0 <br />0 <br />C <br />c <br />0 <br />5 <br />Cn <br />N <br />to <br />IIE! <br />CM <br />M <br />M <br />O <br />co <br />O <br />CV <br />L0 <br />N <br />CU <br />WOOD AND PLASTICS <br />SECTION 061053 - MISCELLANEOUS ROUGH CARPENTRY <br />1.1 MATERIALS <br />A. WOOD PRODUCTS, GENERAL: <br />1. MAXIMUM MOISTURE CONTENT OF LUMBER: [15 PERCENT] <br />[19 PERCENT]. <br />B. WOOD -PRESERVATIVE -TREATED MATERIALS: <br />1. PRESERVATIVE TREATMENT: AWPA U1; USE CATEGORY UC2. <br />a. PRESERVATIVE CHEMICALS: CONTAINING NO ARSENIC OR <br />CHROMIUM. DO NOT USE INORGANIC BORON (SBX) FOR SILL <br />PLATES. <br />2. APPLICATION: ITEMS INDICATED AND THE FOLLOWING: <br />a. ITEMS IN CONTACT WITH ROOFING OR WATERPROOFING. <br />b. ITEMS IN CONTACT WITH CONCRETE OR MASONRY. <br />c. FRAMING LESS THAN 18 INCHES (460 MM) ABOVE GROUND IN <br />CRAWLSPACES. <br />d. FLOOR PLATES INSTALLED OVER CONCRETE SLABS -ON -GRADE. <br />C. FIRE -RETARDANT -TREATED MATERIALS: <br />1. EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND WHERE INDICATED. <br />2. INTERIOR TYPE A UNLESS OTHERWISE INDICATED. <br />3. APPLICATION: ITEMS INDICATED AND THE FOLLOWING: <br />a. FRAMING FOR RAISED PLATFORMS. <br />b. CONCEALED BLOCKING. <br />c. ROOF FRAMING AND BLOCKING. <br />d. ITEMS IN CONTACT WITH ROOFING. <br />e. PLYWOOD BACKING PANELS. <br />D. FRAMING: <br />1. NON -LOAD -BEARING INTERIOR PARTITIONS: CONSTRUCTION OR NO. 2 <br />GRADE. <br />E. MISCELLANEOUS LUMBER: <br />1. DIMENSION LUMBER: CONSTRUCTION OR NO. 2 GRADE. <br />2. UTILITY SHELVING: 19 PERCENT MAXIMUM MOISTURE CONTENT. <br />3. CONCEALED BOARDS: 19 PERCENT MAXIMUM MOISTURE CONTENT. <br />F. PLYWOOD BACKING PANELS: EXPOSURE 1, C-D PLUGGED [, FIRE -RETARDANT <br />TREATED]. <br />G. FASTENERS: HOT -DIP GALVANIZED STEEL WHERE EXPOSED TO WEATHER, IN <br />GROUND CONTACT, IN CONTACT WITH TREATED WOOD, OR IN AREA OF HIGH <br />RELATIVE HUMIDITY. <br />H. METAL FRAMING ANCHORS: <br />1. METAL: GALVANIZED STEEL; HOT -DIP HEAVY GALVANIZED STEEL FOR <br />WOOD -PRESERVATIVE -TREATED LUMBER AND WHERE INDICATED. <br />I. ADHESIVES: ADHESIVES SHALL HAVE A VOC CONTENT OF 70 G/L OR LESS <br />WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24). <br />1.2 INSTALLATION <br />A. FURRING TO RECEIVE PLYWOOD OR HARDBOARD PANELING: 1-BY-3-INCH <br />NOMINAL -SIZE (19-BY-63-MM ACTUAL -SIZE) FURRING AT [24 INCHES (610 MM)] <br />[600 MM] O.C. <br />B. FURRING TO RECEIVE GYPSUM BOARD: 1-BY-2-INCH NOMINAL -SIZE (19-BY-38- <br />MM ACTUAL -SIZE) FURRING AT [16 INCHES (406 MM)] [400 MM] O.C. <br />END OF SECTION 061053 <br />SECTION 064000 - INTERIOR ARCHITECTURAL WOODWORK <br />1.1 SUMMARY <br />A. INTERIOR STANDING AND RUNNING TRIM. <br />B. FLUSH WOOD PANELING AND WAINSCOTS. <br />C. MELAMINE CABINETS. <br />D. SOLID -SURFACING -MATERIAL COUNTERTOPS. <br />E. CLOSET AND UTILITY SHELVING. <br />1.2 QUALITY ASSURANCE <br />A. QUALITY STANDARD: AWI. <br />1.3 MATERIALS <br />A. WOOD PRODUCTS: COMPLY WITH THE FOLLOWING: <br />1. HARDBOARD: AHA A135.4, MADE WITH BINDER CONTAINING NO <br />UREA FORMALDEHYDE. <br />2. MEDIUM -DENSITY FIBERBOARD: ANSI A208.2, GRADE 130, MADE <br />WITH BINDER CONTAINING NO UREA FORMALDEHYDE. <br />3. MOISTURE RESISTANT MEDIUM -DENSITY FIBERBOARD: <br />ANSI A208.2, GRADE MD, MR50, MADE WITH BINDER CONTAINING <br />NO UREA FORMALDEHYDE. <br />4. STRAW -BASED PARTICLEBOARD: ANSI A208.1, GRADE M-2, <br />EXCEPT FOR DENSITY, MADE WITH ADHESIVE CONTAINING NO <br />UREA FORMALDEHYDE. <br />5. SOFTWOOD PLYWOOD: DOC PS 1 <br />6. VENEER -FACED PANEL PRODUCTS (HARDWOOD PLYWOOD): <br />HPVA HP-1, MADE WITH ADHESIVE CONTAINING NO UREA <br />FORMALDEHYDE. <br />B. ADHESIVES, GENERAL: DO NOT USE ADHESIVES THAT CONTAIN <br />UREA FORMALDEHYDE. <br />C. VOC LIMITS FOR INSTALLATION ADHESIVES AND GLUES: USE <br />INSTALLATION ADHESIVES THAT COMPLY WITH THE FOLLOWING LIMITS <br />FOR VOC CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, <br />SUBPART D (EPA METHOD 24): <br />1. WOOD GLUES: 30 G/L. <br />2. PANEL ADHESIVE: 50 G/L <br />3. MULTIPURPOSE CONSTRUCTION ADHESIVE: 70 G/L <br />4. CONTACT ADHESIVE: 80 G/L. <br />a. SPECIAL PURPOSE: 250 G/L <br />D. CLOSET AND UTILITY SHELVING: <br />1. GRADE: ECONOMY. <br />2. SHELF MATERIAL: 3/4 INCH (19 MM) THERMOSET DECORATIVE <br />PANEL WITH PVC OR POLYESTER EDGE BANDING. <br />3. CLEATS: 3/4 INCH (19 MM) PANEL PRODUCT. <br />E. SHOP FINISHING: <br />1. GRADE: SAME GRADE AS WOODWORK. <br />2. EXTENT: ALL WOODWORK SHOP FINISHED. <br />1.4 INSTALLATION <br />A. SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK, REFINISH CUT <br />SURFACES, AND REPAIR DAMAGED FINISH AT CUTS. <br />B. ANCHOR MILLWORK TO ANCHORS OR BLOCKING BUILT IN OR DIRECTLY <br />ATTACHED TO SUBSTRATES. SECURE WITH COUNTERSUNK, <br />CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR <br />COMPLETE INSTALLATION. USE FINE FINISHING NAILS OR FINISHING <br />SCREWS FOR EXPOSED FASTENING, COUNTERSUNK AND FILLED FLUSH <br />WITH MILLWORK AND MATCHING FINAL FINISH IF TRANSPARENT FINISH <br />IS INDICATED. <br />C. CABINETS: INSTALL WITHOUT DISTORTION SO DOORS AND DRAWERS FIT <br />OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST <br />HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO <br />PROVIDE UNENCUMBERED OPERATION. COMPLETE INSTALLATION OF <br />HARDWARE AND ACCESSORY ITEMS AS INDICATED. <br />1. INSTALL CABINETS WITH NO MORE THAN 1/8 INCH IN 96 INCH <br />(3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A <br />STRAIGHT LINE. <br />D. COUNTERTOPS: ANCHOR SECURELY BY SCREWING THROUGH CORNER <br />BLOCKS OF BASE CABINETS OR OTHER SUPPORTS INTO UNDERSIDE OF <br />COUNTERTOP. <br />1. ALIGN ADJACENT SOLID -SURFACING -MATERIAL COUNTERTOPS <br />AND FORM SEAMS TO COMPLY WITH MANUFACTURER'S WRITTEN <br />RECOMMENDATIONS USING ADHESIVE IN COLOR TO MATCH <br />COUNTERTOP. CAREFULLY DRESS JOINTS SMOOTH, REMOVE <br />SURFACE SCRATCHES, AND CLEAN ENTIRE SURFACE. <br />2. INSTALL COUNTERTOPS WITH NO MORE THAN 1/8 INCH IN 96 INCH <br />(3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A <br />STRAIGHT LINE. <br />3. SECURE COVED BACKSPLASHES TO TOPS PER MANUFACTURES <br />FABRICATION MANUAL AND TO WALLS WITH ADHESIVE. <br />4. CALK SPACE BETWEEN BACKSPLASH AND WALL WITH SEALANT <br />SPECIFIED IN DIVISION 7 SECTION "JOINT SEALANTS." <br />END OF SECTION 064000 <br />WOOD AND PLASTICS (CONTINUED) <br />SECTION 064400 - PLASTIC PANELING <br />PART 1-GENERAL <br />1.1 SUMMARY <br />A. SECTION INCLUDES THE FOLLOWING: <br />1. GLASS -FIBER REINFORCED PLASTIC (FRP) WALL PANELING. <br />2. MOLDING, ADHESIVES, AND JOINT SEALANTS. <br />1.2 PLASTIC SHEET PANELING <br />A. GLASS -FIBER -REINFORCED PLASTIC PANELING: GELCOAT-FINISHED, <br />GLASS -FIBER REINFORCED PLASTIC PANELS COMPLYING WITH ASTM D 5319. <br />1. LOW -EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE <br />TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA <br />DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE <br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS <br />SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS." <br />2. NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES. <br />3. COLOR: WHITE. <br />4. MOLDING COLOR: WHITE. <br />5. SURFACE FINISH: MOLDED PEBBLE TEXTURE. <br />B. UNREINFORCED POLYPROPYLENE PANELING: SOLID POLYPROPYLENE <br />PANELS MADE FROM NO LESS THAN 80 PERCENT RECYCLED MATERIAL. <br />1. LOW -EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE <br />TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA <br />DEPARTMENT OF PUBLIC HEALTH'S (FORMERLY, THE CALIFORNIA <br />DEPARTMENT OF HEALTH SERVICES') "STANDARD METHOD FOR THE <br />TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL <br />EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL <br />CHAMBERS." <br />2. NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES. <br />3. COLOR: WHITE. <br />4. MOLDING COLOR: WHITE. <br />5. SURFACE FINISH: MOLDED PEBBLE TEXTURE. <br />1.3 ADHESIVES <br />A. AS RECOMMENDED BY PLASTIC PANELING MANUFACTURER. <br />1. VOC LIMIT: 50 G/L <br />1.4 ACCESSORIES <br />A. TRIM ACCESSORIES: MANUFACTURER'S STANDARD ONE-PIECE VINYL <br />EXTRUSIONS DESIGNED TO RETAIN AND COVER EDGES OF PANELS. <br />PROVIDE DIVISION BARS, INSIDE CORNERS, OUTSIDE CORNERS, AND CAPS <br />AS NEEDED TO CONCEAL EDGES. <br />1. COLOR: WHITE. <br />END OF SECTION 064400 <br />THERMAL AND MOISTURE PROTECTION <br />SECTION 07841 - THROUGH -PENETRATION FIRESTOP SYSTEMS <br />1.1 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. <br />1.2 QUALITY ASSURANCE <br />A. INSTALLER QUALIFICATIONS: AN FM GLOBAL -APPROVED FIRESTOP <br />CONTRACTOR OR A UL-QUALIFIED FIRESTOP CONTRACTOR. <br />B. FIRE -TEST -RESPONSE CHARACTERISTICS: TESTED PER ASTM E 814 BY <br />QUALIFIED TESTING AND INSPECTING AGENCY. <br />1.3 PENETRATION FIRESTOPPING <br />A. PENETRATIONS IN FIRE -RESISTANCE -RATED WALLS: F-RATINGS PER <br />ASTM E 814 OR UL 1479. <br />B. PENETRATIONS IN HORIZONTAL ASSEMBLIES: F- AND T-RATINGS PER <br />ASTM E 814 OR UL 1479: <br />C. PENETRATIONS IN SMOKE BARRIERS: L-RATINGS PER UL 1479. <br />D. W-RATINGS: PER UL 1479. <br />E. VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND <br />SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC <br />CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D <br />(EPA METHOD 24): <br />1. SEALANTS: 250 G/L. <br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L. <br />3. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L. <br />1.4 INSTALLATION <br />A. IDENTIFICATION: PREPRINTED METAL OR PLASTIC LABELS, PERMANENTLY <br />ATTACHED. <br />1.5 FIELD QUALITY CONTROL <br />A. INSPECTION OF INSTALLED FIRESTOP SYSTEMS: BY OWNER -ENGAGED <br />AGENCY ACCORDING TO ASTM E 2174 REQUIREMENTS. <br />END OF SECTION 07841 <br />SECTION 078446 - FIRE -RESISTIVE JOINT SYSTEMS <br />1.1 SUMMARY <br />A. FIRE -RESISTIVE JOINT SYSTEMS FOR THE FOLLOWING: <br />1. JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED CONSTRUCTIONS. <br />2. JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS. <br />3. JOINTS IN SMOKE BARRIERS. <br />1.2 PERFORMANCE REQUIREMENTS <br />A. FIRE -RESISTANCE RATINGS OF JOINT SYSTEMS IN AND BETWEEN FIRE - <br />RESISTANCE -RATED CONSTRUCTIONS: EQUALING OR EXCEEDING THE <br />FIRE -RESISTANCE RATINGS OF CONSTRUCTION THAT THEY JOIN, [AND WITH <br />MOVEMENT CAPABILITIES INDICATED] AS DETERMINED BY UL 2079. <br />1.3 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. <br />1.4 QUALITY ASSURANCE <br />A. FIRE -TEST -RESPONSE CHARACTERISTICS: TESTED BY QUALIFIED TESTING <br />AND INSPECTING AGENCY. <br />1.5 FIRE -RESISTIVE JOINT SYSTEMS <br />A. DESIGNATION SYSTEM FOR JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED <br />CONSTRUCTIONS: ALPHANUMERIC SYSTEMS LISTED IN UL'S "FIRE <br />RESISTANCE DIRECTORY" UNDER PRODUCT CATEGORY XHBN. <br />B. JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED CONSTRUCTION: EQUAL TO <br />OR EXCEEDING THE FIRE -RESISTANCE RATING OF CONSTRUCTION THEY WILL <br />JOIN. <br />C. JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS: EQUAL TO OR <br />EXCEEDING THE FIRE -RESISTANCE RATING OF THE FLOOR ASSEMBLY. <br />D. JOINTS IN SMOKE BARRIERS: <br />1. L-RATING: NOT EXCEEDING 5.0 CFM/FT (0.00775 CU. M/S X M) OF JOINT <br />AT 0.30 INCH WG (74.7 PA) AT BOTH AMBIENT AND ELEVATED <br />TEMPERATURES. <br />E. EXPOSED FIRE -RESISTIVE JOINT SYSTEMS: PROVIDE PRODUCTS WITH <br />FLAME -SPREAD AND SMOKE -DEVELOPED INDEXES OF LESS THAN 25 AND 450, <br />RESPECTIVELY, AS DETERMINED PER ASTM E 84. <br />F. VOC CONTENT: FIRE -RESISTIVE JOINT SYSTEM SEALANTS SHALL COMPLY <br />WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED <br />ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24): <br />1. ARCHITECTURAL SEALANTS: 250 G/L. <br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L. <br />G. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L. <br />H. ACCESSORIES: FORMING MATERIALS AND OTHER COMPONENTS NEEDED <br />TO INSTALL FILL MATERIALS AND MAINTAIN RATINGS REQUIRED. <br />END OF SECTION 078446 <br />THERMAL AND MOISTURE PROTECTION (CONT) <br />SECTION 079200 - JOINT SEALANTS <br />1.1 MATERIALS <br />A. VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND <br />SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC <br />CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D <br />(EPA METHOD 24): <br />1. SEALANTS: 250 G/L. <br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L. <br />3. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L. <br />B. SUITABILITY FOR CONTACT WITH FOOD: WHERE SEALANTS ARE INDICATED <br />FOR JOINTS THAT WILL COME IN REPEATED CONTACT WITH FOOD, PROVIDE <br />PRODUCTS THAT COMPLY WITH 21 CFR 177.2600. <br />C. ELASTOMERIC JOINT SEALANTS: LIQUID APPLIED, CHEMICALLY CURING; <br />ASTM C 920. <br />1. MULTICOMPONENT NONSAG NEUTRAL -CURING SILICONE SEALANT <br />ES-1. <br />2. SINGLE -COMPONENT MILDEW -RESISTANT NEUTRAL -CURING <br />SILICONE SEALANT ES-2. <br />3. SINGLE -COMPONENT MILDEW -RESISTANT ACID -CURING SILICONE <br />SEALANT ES-3. <br />4. SINGLE -COMPONENT MILDEW -RESISTANT ACID -CURING RTV <br />SILICONE SEALANT ES-4. <br />5. MULTICOMPONENT NONSAG POLYUREA SEALANT ES-5. <br />6. MULTICOMPONENT NONSAG POLYUREA FILLER ES-6. <br />D. LATEX SEALANT LS-1: COMPLY WITH ASTM C 834, TYPE P, GRADE NF. <br />E. JOINT -SEALANT BACKING: <br />1.2 JOINT -SEALANT SCHEDULE <br />A. JOINT -SEALANT APPLICATION JS-1: EXTERIOR HORIZONTAL NONTRAFFIC <br />AND TRAFFIC ISOLATION AND CONTRACTION JOINTS IN CAST -IN -PLACE <br />CONCRETE SLABS. <br />1. JOINT SEALANT: ES-5. <br />B. JOINT -SEALANT APPLICATION JS-2: EXTERIOR PERIMETER JOINTS BETWEEN <br />WALL AND FRAMES OF DOORS AND WINDOWS. <br />1. JOINT SEALANT: ES-1. <br />C. JOINT -SEALANT APPLICATION JS-3: EXTERIOR CONTROL AND EXPANSION <br />JOINTS IN HORIZONTAL TRAFFIC SURFACES OF BRICK PAVERS, CERAMIC <br />TILE, STONE PAVING UNITS, CONCRETE TILE. <br />1. JOINT SEALANT: MULTICOMPONENT POURABLE POLYSULFIDE <br />SEALANT. <br />2. JOINT -SEALANT COLOR: AS SELECTED BY ARCHITECT FROM <br />MANUFACTURER'S FULL RANGE. <br />D. JOINT -SEALANT APPLICATION JS-4: INTERIOR PERIMETER JOINTS OF <br />EXTERIOR OPENINGS. <br />1. JOINT SEALANT: ES-3. <br />E. JOINT -SEALANT APPLICATION JS-5: INTERIOR CERAMIC TILE EXPANSION, <br />CONTROL, CONTRACTION, AND ISOLATION JOINTS IN HORIZONTAL TRAFFIC <br />SURFACES. <br />1. JOINT SEALANT: ES-3. <br />2. JOINT -SEALANT COLOR: AS NOTED. <br />F. JOINT -SEALANT APPLICATION JS-6: INTERIOR JOINTS BETWEEN PLUMBING <br />FIXTURES AND ADJOINING WALLS, FLOORS, AND COUNTERS. <br />1. JOINT SEALANT: ES-3. <br />2. JOINT -SEALANT COLOR: TRANSLUCENT. <br />G. JOINT -SEALANT APPLICATION JS-7: VERTICAL JOINTS ON EXPOSED <br />SURFACES OF INTERIOR PARTITIONS. <br />1. JOINT SEALANT: ES-3. <br />H. JOINT -SEALANT APPLICATION JS-8: PERIMETER JOINTS BETWEEN INTERIOR <br />WALL SURFACES AND FRAMES OF INTERIOR DOORS, WINDOWS. <br />1. JOINT SEALANT: ES-3. <br />I. JOINT -SEALANT APPLICATION JS-9: HVAC JOINTS. <br />1. JOINT SEALANT: ES-2. <br />2. JOINT -SEALANT COLOR: ALUMINUM. <br />J. JOINT -SEALANT APPLICATION JS-10: NON -POROUS MATERIAL TO <br />NON -POROUS MATERIAL. <br />1. JOINT SEALANT: ES-4. <br />2. JOINT -SEALANT COLOR: CLEAR. <br />END OF SECTION 079200 <br />DOORS AND WINDOWS <br />SECTION 081416 - FLUSH WOOD DOORS <br />1.1 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF DOOR INDICATED. INCLUDE DETAILS <br />OF CORE AND EDGE CONSTRUCTION AND TRIM FOR OPENINGS. <br />B. SHOP DRAWINGS: INDICATE LOCATION, SIZE, AND HAND OF EACH DOOR; <br />ELEVATION OF EACH KIND OF DOOR; CONSTRUCTION DETAILS NOT <br />COVERED IN PRODUCT DATA; LOCATION AND EXTENT OF HARDWARE <br />BLOCKING; AND OTHER PERTINENT DATA. <br />1. INDICATE DIMENSIONS AND LOCATIONS OF MORTISES AND HOLES <br />FOR HARDWARE. <br />2. INDICATE DIMENSIONS AND LOCATIONS OF CUTOUTS. <br />3. INDICATE REQUIREMENTS FOR VENEER MATCHING. <br />4. INDICATE DOORS TO BE FACTORY FINISHED AND FINISH <br />REQUIREMENTS. <br />5. INDICATE FIRE -PROTECTION RATINGS FOR FIRE -RATED DOORS. <br />C. WARRANTY: SAMPLE OF SPECIAL WARRANTY. <br />1.2 QUALITY ASSURANCE <br />A. QUALITY STANDARD: AWI. <br />1. AWI QUALITY CERTIFICATION LABELS OR AN AWI LETTER OF <br />LICENSING FOR DOORS. <br />2. WI -CERTIFIED COMPLIANCE CERTIFICATE FOR DOORS AND <br />INSTALLATION. <br />B. FIRE -RATED WOOD DOORS: POSITIVE PRESSURE TESTING. <br />1.3 DOOR CONSTRUCTION, GENERAL <br />A. LOW -EMITTING MATERIALS: MADE WITH ADHESIVES AND COMPOSITE WOOD <br />PRODUCTS THAT DO HAVE NO ADDED UREA FORMALDEHYDE. <br />B. WDMA I.S.1-A PERFORMANCE GRADE: HEAVY DUTY UNLESS OTHERWISE <br />INDICATED. <br />1.4 VENEERED -FACED DOORS FOR TRANSPARENT FINISH <br />A. INTERIOR SOLID -CORE DOORS: <br />1. CORE: PARTICLEBOARD. <br />2. CONSTRUCTION: FIVE OR SEVEN PLIES, BONDED. <br />1.5 PRIMING/FINISHING <br />A. SHOP PRIMING: <br />1. DOORS FOR OPAQUE FINISH: ONE COAT OF WOOD PRIMER. <br />2. DOORS FOR TRANSPARENT FINISH: STAIN AND FIRST COAT OF <br />FINISH. <br />B. FACTORY FINISHING: ALL DOORS. <br />END OF SECTION 081416 <br />DOORS AND WINDOWS (CONTINUED <br />SECTION 08331 - OVERHEAD COILING DOORS <br />1.1 <br />1.2 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE AND SIZE OF OVERHEAD COILING DOOR <br />AND ACCESSORY. INCLUDE THE FOLLOWING: <br />B. SHOP DRAWINGS: FOR EACH INSTALLATION AND FOR SPECIAL COMPONENTS <br />NOT DIMENSIONED OR DETAILED IN MANUFACTURER'S PRODUCT DATA. <br />INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO <br />OTHER WORK. <br />1. DETAIL EQUIPMENT ASSEMBLIES AND INDICATE DIMENSIONS, <br />WEIGHTS, LOADS, REQUIRED CLEARANCES, METHOD OF FIELD <br />ASSEMBLY, COMPONENTS, AND LOCATION AND SIZE OF EACH FIELD <br />CONNECTION. <br />C. SAMPLES FOR INITIAL SELECTION: MANUFACTURER'S FINISH CHARTS <br />SHOWING FULL RANGE OF COLORS AND TEXTURES AVAILABLE FOR UNITS <br />WITH FACTORY -APPLIED FINISHES. <br />1. INCLUDE SIMILAR SAMPLES OF ACCESSORIES INVOLVING COLOR <br />SELECTION. <br />D. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF EXPOSED FINISH <br />REQUIRED, PREPARED ON SAMPLES OF SIZE INDICATED BELOW. <br />1. CURTAIN SLATS: 12 INCHES (305 MM) LONG. <br />2. BOTTOM BAR: 6 INCHES (150 MM) LONG. <br />3. GUIDES: 6 INCHES (150 MM) LONG. <br />4. BRACKETS: 6 INCHES (150 MM) SQUARE. <br />5. HOOD: 6 INCHES (150 MM) SQUARE. <br />E. DELEGATED -DESIGN SUBMITTAL: FOR OVERHEAD COILING DOORS INDICATED <br />TO COMPLY WITH PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA, <br />INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED <br />PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION. <br />1. DETAIL FABRICATION AND ASSEMBLY OF SEISMIC RESTRAINTS. <br />2. SUMMARY OF FORCES AND LOADS ON WALLS AND JAMBS. <br />F. QUALIFICATION DATA: FOR QUALIFIED INSTALLER. <br />G. SEISMIC QUALIFICATION CERTIFICATES: FOR OVERHEAD COILING DOORS, <br />ACCESSORIES, AND COMPONENTS, FROM MANUFACTURER. <br />H. MAINTENANCE DATA: FOR OVERHEAD COILING DOORS TO INCLUDE IN <br />MAINTENANCE MANUALS. <br />1.3 PERFORMANCE REQUIREMENTS <br />A. OPERATION -CYCLE REQUIREMENTS: PROVIDE OVERHEAD COILING GRILLE <br />COMPONENTS AND OPERATORS CAPABLE OF OPERATING FOR NOT LESS <br />THAN 50,000 CYCLES AND FOR 25 CYCLES PER DAY. <br />1.4 DOOR ASSEMBLY <br />A. GENERAL: FABRICATE OVERHEAD COILING GRILLE CURTAIN CONSISTING OF <br />A NETWORK OF 5/16 INCH (8 MM) MINIMUM DIAMETER HORIZONTAL RODS, OR <br />RODS COVERED WITH TUBE SPACERS, SPACED AS INDICATED. <br />INTERCONNECT RODS BY VERTICAL LINKS APPROXIMATELY 5/8 INCH (16 MM) <br />WIDE, SPACED AS INDICATED AND ROTATING ON RODS. <br />1. SPACE RODS AT APPROXIMATELY 1-1/2 INCHES (38 MM) O.C. <br />2. SPACE LINKS APPROXIMATELY 9 INCHES (228 MM) APART IN A <br />STRAIGHT IN -LINE PATTERN. <br />3. ALUMINUM GRILLE CURTAIN: ASTM B 221(ASTM B 221M), ALLOY <br />AND TEMPER RECOMMENDED BY ALUMINUM PRODUCER AND <br />FINISHER FOR TYPE OF USE AND FINISH INDICATED. <br />B. HOOD: ALUMINUM. <br />C. MANUAL DOOR OPERATOR. <br />1.5 INSTALLATION <br />A. FACTORY -AUTHORIZED REPRESENTATIVE TO [PERFORM STARTUP SERVICE <br />AND TESTING] [AND] [TRAIN OWNER'S PERSONNEL]. <br />END OF SECTION 08331 <br />SECTION 08345 - DOUBLE ACTING SWING DOORS <br />PART 1- GENERAL <br />1.1 SUMMARY <br />A. SECTION INCLUDES: <br />1. SOLID -CORE DOUBLE ACTING SWING DOORS WITH PLASTIC <br />LAMINATE FACES. <br />1.2 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE <br />CONSTRUCTION DETAILS, MATERIAL DESCRIPTIONS, CORE <br />DESCRIPTIONS, FIRE -RESISTANCE RATING, TEMPERATURE -RISE <br />RATINGS, AND FINISHES. <br />B. SHOP DRAWINGS: INCLUDE THE FOLLOWING: <br />1. ELEVATIONS OF EACH DOOR DESIGN. <br />2. DETAILS OF DOORS, INCLUDING VERTICAL AND HORIZONTAL <br />EDGE DETAILS AND METAL THICKNESSES. <br />3. FRAME DETAILS FOR EACH FRAME TYPE, INCLUDING <br />DIMENSIONED PROFILES AND METAL THICKNESSES. <br />4. LOCATIONS OF REINFORCEMENT AND PREPARATIONS FOR <br />HARDWARE. <br />5. DETAILS OF ACCESSORIES. <br />6. DETAILS OF MOLDINGS, REMOVABLE STOPS, AND GLAZING. <br />1.3 STANDARD DOUBLE ACTING SWING DOORS <br />A. GENERAL: PROVIDE DOORS OF DESIGN INDICATED, NOT LESS THAN <br />THICKNESS INDICATED; FABRICATED WITH SMOOTH SURFACES, <br />WITHOUT VISIBLE JOINTS OR SEAMS ON EXPOSED FACES UNLESS <br />OTHERWISE INDICATED. COMPLY WITH ANSI/SDI A250.8. <br />1. DESIGN: AS INDICATED. <br />B. CORE CONSTRUCTION: 3/4 INCH (19 MM) EXTERIOR GRADE SOLID WOOD <br />CORE MADE WITH ADHESIVES AND COMPOSITE WOOD PRODUCTS THAT <br />DO NOT CONTAIN UREA FORMALDEHYDE. <br />1. VERTICAL EDGES FOR DOUBLE-ACTING DOORS: ROUND <br />VERTICAL EDGES WITH 2-1/8 INCH (54 MM) RADIUS. <br />2. TOP AND BOTTOM EDGES: CLOSED WITH FLUSH OR INVERTED <br />0.042 INCH (1.0 MM) THICK, END CLOSURES OR CHANNELS OF <br />SAME MATERIAL AS FACE SHEETS. <br />3. TOLERANCES: COMPLY WITH SDI 117, "MANUFACTURING <br />TOLERANCES FOR STANDARD STEEL DOORS AND FRAMES." <br />C. INTERIOR DOORS: FACE SHEETS FABRICATED FROM DECORATIVE HIGH <br />PRESSURE LAMINATE. PROVIDE DOORS COMPLYING WITH <br />REQUIREMENTS INDICATED BELOW BY REFERENCING ANSI/SDI A250.8 <br />FOR LEVEL AND MODEL AND ANSI/SDI A250.4 FOR PHYSICAL <br />PERFORMANCE LEVEL: <br />1. LEVEL 1 AND PHYSICAL PERFORMANCE LEVEL C <br />(STANDARD DUTY). <br />a. WIDTH: AS INDICATED ON DRAWINGS. <br />D. HARDWARE REINFORCEMENT: FABRICATE ACCORDING TO <br />ANSI/SDI A250.6 WITH REINFORCING PLATES OF 18 GAUGE STAINLESS <br />STEEL <br />E. FABRICATE CONCEALED STIFFENERS AND HARDWARE REINFORCEMENT <br />FROM EITHER COLD- OR HOT -ROLLED STEEL SHEET. <br />1.4 STOPS AND MOLDINGS <br />A. MOLDINGS FOR GLAZED LITES IN DOORS: <br />MINIMUM 0.032 INCH (0.8 MM) THICK. <br />B. LOOSE STOPS FOR GLAZED LITES IN FRAMES: <br />MINIMUM 0.032 INCH (0.8 MM) THICK, FABRICATED FROM SAME MATERIAL <br />AS FRAMES IN WHICH THEY ARE INSTALLED. <br />1.5 STEEL FINISHES <br />A. PRIME FINISH: APPLY MANUFACTURER'S STANDARD PRIMER <br />IMMEDIATELY AFTER CLEANING AND PRETREATING. <br />1. SHOP PRIMER: MANUFACTURER'S STANDARD, FAST -CURING, <br />LEAD- AND CHROMATE -FREE PRIMER COMPLYING WITH <br />ANSI/SDI A250.10 ACCEPTANCE CRITERIA; RECOMMENDED BY <br />PRIMER MANUFACTURER FOR SUBSTRATE; COMPATIBLE WITH <br />SUBSTRATE AND FIELD -APPLIED COATINGS DESPITE <br />PROLONGED EXPOSURE. <br />B. FACTORY -APPLIED PAINT FINISH: MANUFACTURER'S STANDARD, <br />COMPLYING WITH ANSI/SDI A250.3 FOR PERFORMANCE AND <br />ACCEPTANCE CRITERIA. <br />1.6 COLOR AND GLOSS: AS INDICATED BY MANUFACTURER'S DESIGNATIONS. <br />END OF SECTION 08345 <br />STARBUCKS <br />2401 UTAH AVENUE SOUTH <br />SEATTLE, WASHINGTON 98134 <br />(206) 318-1575 <br />THESE DRAWINGS AND SPECIFICATIONS ARE <br />CONFIDENTIAL AND SHALL REMAIN THE SOLE <br />PROPERTY OF STARBUCKS CORPORATION, <br />WHICH IS THE OWNER OF THE COPYRIGHT IN <br />THIS WORK. THEY SHALL NOT BE <br />REPRODUCED (IN WHOLE OR IN PART), SHARED <br />WITH THIRD PARTIES OR USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS TO THIS <br />PROJECT WITHOUT THE PRIOR WRITTEN <br />CONSENT OF STARBUCKS CORPORATION. <br />THESE DRAWINGS AND SPECIFICATIONS ARE <br />INTENDED TO EXPRESS DESIGN INTENT FOR A <br />PROTOTYPICAL STARBUCKS STORE (WHICH IS <br />SUBJECT TO CHANGE AT ANYTIME) AND DO <br />NOT REFLECT ACTUAL SITE CONDITIONS. <br />NEITHER PARTY SHALL HAVE ANY OBLIGATION <br />NOR LIABILITY TO THE OTHER (EXCEPT STATED <br />ABOVE) UNTIL A WRITTEN AGREEMENT IS <br />FULLY EXECUTED BY BOTH PARTIES. <br />STARBUCKS TEMPLATE VERSION 2018.01.26 <br />I - 0 1• <br />700 W. Pete Rose Way, Suite 460 Donald J. Rothman I <br />Cincinnati, OH 45203 Architect In Charge <br />Tel: (513) 421-2210 License: AR0017303 <br />Design Forum <br />Engineering <br />700 W. Pete Rose Way, Suite 460 Timothy L Raberding, PE <br />Cincinnati, OH 45203 Professional Engineer <br />Tel: (513) 421-2210 License: 62078 <br />APoFF`O�o N 2 5 2018 <br />Ak C. <br />D J: RETtio ', 9 <br />N0 <br />L.J. <br />L.J.. <br />W <br />r� <br />V <br />M <br />W 06 <br />Ir- <br />Z O <br />w rrCO^ <br />0 vJ <br />d D <br />M <br />(`M <br />C) LL <br />W J J <br />LU J <br />J = <br />Q Q <br />U <br />W O <br />a �N <br />(STORE #: 56350 I <br />PROJECT #: 81186-001 <br />ISSUE DATE: 06/22/18 <br />DESIGN PROGRAM ROMINA VIGNOLO <br />MANAGER: <br />LEEDO AP: <br />PRODUCTION DESIGNER: MICHAEL.B.SARKA <br />ICHECKED BY- M. MCCAUGHEY <br />Revision Schedule <br />Rev Date By Description <br />SHEET TITLE: <br />CONSTRUCTION <br />SPECIFICATIONS <br />SCALE: NO SCALE <br />SHEET NUMBER: <br />G-012 <br />