<br />WOOD AND PLASTICS
<br />SECTION 061053 - MISCELLANEOUS ROUGH CARPENTRY
<br />1.1 MATERIALS
<br />A. WOOD PRODUCTS, GENERAL:
<br />1. MAXIMUM MOISTURE CONTENT OF LUMBER: [15 PERCENT]
<br />[19 PERCENT].
<br />B. WOOD -PRESERVATIVE -TREATED MATERIALS:
<br />1. PRESERVATIVE TREATMENT: AWPA U1; USE CATEGORY UC2.
<br />a. PRESERVATIVE CHEMICALS: CONTAINING NO ARSENIC OR
<br />CHROMIUM. DO NOT USE INORGANIC BORON (SBX) FOR SILL
<br />PLATES.
<br />2. APPLICATION: ITEMS INDICATED AND THE FOLLOWING:
<br />a. ITEMS IN CONTACT WITH ROOFING OR WATERPROOFING.
<br />b. ITEMS IN CONTACT WITH CONCRETE OR MASONRY.
<br />c. FRAMING LESS THAN 18 INCHES (460 MM) ABOVE GROUND IN
<br />CRAWLSPACES.
<br />d. FLOOR PLATES INSTALLED OVER CONCRETE SLABS -ON -GRADE.
<br />C. FIRE -RETARDANT -TREATED MATERIALS:
<br />1. EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND WHERE INDICATED.
<br />2. INTERIOR TYPE A UNLESS OTHERWISE INDICATED.
<br />3. APPLICATION: ITEMS INDICATED AND THE FOLLOWING:
<br />a. FRAMING FOR RAISED PLATFORMS.
<br />b. CONCEALED BLOCKING.
<br />c. ROOF FRAMING AND BLOCKING.
<br />d. ITEMS IN CONTACT WITH ROOFING.
<br />e. PLYWOOD BACKING PANELS.
<br />D. FRAMING:
<br />1. NON -LOAD -BEARING INTERIOR PARTITIONS: CONSTRUCTION OR NO. 2
<br />GRADE.
<br />E. MISCELLANEOUS LUMBER:
<br />1. DIMENSION LUMBER: CONSTRUCTION OR NO. 2 GRADE.
<br />2. UTILITY SHELVING: 19 PERCENT MAXIMUM MOISTURE CONTENT.
<br />3. CONCEALED BOARDS: 19 PERCENT MAXIMUM MOISTURE CONTENT.
<br />F. PLYWOOD BACKING PANELS: EXPOSURE 1, C-D PLUGGED [, FIRE -RETARDANT
<br />TREATED].
<br />G. FASTENERS: HOT -DIP GALVANIZED STEEL WHERE EXPOSED TO WEATHER, IN
<br />GROUND CONTACT, IN CONTACT WITH TREATED WOOD, OR IN AREA OF HIGH
<br />RELATIVE HUMIDITY.
<br />H. METAL FRAMING ANCHORS:
<br />1. METAL: GALVANIZED STEEL; HOT -DIP HEAVY GALVANIZED STEEL FOR
<br />WOOD -PRESERVATIVE -TREATED LUMBER AND WHERE INDICATED.
<br />I. ADHESIVES: ADHESIVES SHALL HAVE A VOC CONTENT OF 70 G/L OR LESS
<br />WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24).
<br />1.2 INSTALLATION
<br />A. FURRING TO RECEIVE PLYWOOD OR HARDBOARD PANELING: 1-BY-3-INCH
<br />NOMINAL -SIZE (19-BY-63-MM ACTUAL -SIZE) FURRING AT [24 INCHES (610 MM)]
<br />[600 MM] O.C.
<br />B. FURRING TO RECEIVE GYPSUM BOARD: 1-BY-2-INCH NOMINAL -SIZE (19-BY-38-
<br />MM ACTUAL -SIZE) FURRING AT [16 INCHES (406 MM)] [400 MM] O.C.
<br />END OF SECTION 061053
<br />SECTION 064000 - INTERIOR ARCHITECTURAL WOODWORK
<br />1.1 SUMMARY
<br />A. INTERIOR STANDING AND RUNNING TRIM.
<br />B. FLUSH WOOD PANELING AND WAINSCOTS.
<br />C. MELAMINE CABINETS.
<br />D. SOLID -SURFACING -MATERIAL COUNTERTOPS.
<br />E. CLOSET AND UTILITY SHELVING.
<br />1.2 QUALITY ASSURANCE
<br />A. QUALITY STANDARD: AWI.
<br />1.3 MATERIALS
<br />A. WOOD PRODUCTS: COMPLY WITH THE FOLLOWING:
<br />1. HARDBOARD: AHA A135.4, MADE WITH BINDER CONTAINING NO
<br />UREA FORMALDEHYDE.
<br />2. MEDIUM -DENSITY FIBERBOARD: ANSI A208.2, GRADE 130, MADE
<br />WITH BINDER CONTAINING NO UREA FORMALDEHYDE.
<br />3. MOISTURE RESISTANT MEDIUM -DENSITY FIBERBOARD:
<br />ANSI A208.2, GRADE MD, MR50, MADE WITH BINDER CONTAINING
<br />NO UREA FORMALDEHYDE.
<br />4. STRAW -BASED PARTICLEBOARD: ANSI A208.1, GRADE M-2,
<br />EXCEPT FOR DENSITY, MADE WITH ADHESIVE CONTAINING NO
<br />UREA FORMALDEHYDE.
<br />5. SOFTWOOD PLYWOOD: DOC PS 1
<br />6. VENEER -FACED PANEL PRODUCTS (HARDWOOD PLYWOOD):
<br />HPVA HP-1, MADE WITH ADHESIVE CONTAINING NO UREA
<br />FORMALDEHYDE.
<br />B. ADHESIVES, GENERAL: DO NOT USE ADHESIVES THAT CONTAIN
<br />UREA FORMALDEHYDE.
<br />C. VOC LIMITS FOR INSTALLATION ADHESIVES AND GLUES: USE
<br />INSTALLATION ADHESIVES THAT COMPLY WITH THE FOLLOWING LIMITS
<br />FOR VOC CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59,
<br />SUBPART D (EPA METHOD 24):
<br />1. WOOD GLUES: 30 G/L.
<br />2. PANEL ADHESIVE: 50 G/L
<br />3. MULTIPURPOSE CONSTRUCTION ADHESIVE: 70 G/L
<br />4. CONTACT ADHESIVE: 80 G/L.
<br />a. SPECIAL PURPOSE: 250 G/L
<br />D. CLOSET AND UTILITY SHELVING:
<br />1. GRADE: ECONOMY.
<br />2. SHELF MATERIAL: 3/4 INCH (19 MM) THERMOSET DECORATIVE
<br />PANEL WITH PVC OR POLYESTER EDGE BANDING.
<br />3. CLEATS: 3/4 INCH (19 MM) PANEL PRODUCT.
<br />E. SHOP FINISHING:
<br />1. GRADE: SAME GRADE AS WOODWORK.
<br />2. EXTENT: ALL WOODWORK SHOP FINISHED.
<br />1.4 INSTALLATION
<br />A. SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK, REFINISH CUT
<br />SURFACES, AND REPAIR DAMAGED FINISH AT CUTS.
<br />B. ANCHOR MILLWORK TO ANCHORS OR BLOCKING BUILT IN OR DIRECTLY
<br />ATTACHED TO SUBSTRATES. SECURE WITH COUNTERSUNK,
<br />CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR
<br />COMPLETE INSTALLATION. USE FINE FINISHING NAILS OR FINISHING
<br />SCREWS FOR EXPOSED FASTENING, COUNTERSUNK AND FILLED FLUSH
<br />WITH MILLWORK AND MATCHING FINAL FINISH IF TRANSPARENT FINISH
<br />IS INDICATED.
<br />C. CABINETS: INSTALL WITHOUT DISTORTION SO DOORS AND DRAWERS FIT
<br />OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST
<br />HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO
<br />PROVIDE UNENCUMBERED OPERATION. COMPLETE INSTALLATION OF
<br />HARDWARE AND ACCESSORY ITEMS AS INDICATED.
<br />1. INSTALL CABINETS WITH NO MORE THAN 1/8 INCH IN 96 INCH
<br />(3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A
<br />STRAIGHT LINE.
<br />D. COUNTERTOPS: ANCHOR SECURELY BY SCREWING THROUGH CORNER
<br />BLOCKS OF BASE CABINETS OR OTHER SUPPORTS INTO UNDERSIDE OF
<br />COUNTERTOP.
<br />1. ALIGN ADJACENT SOLID -SURFACING -MATERIAL COUNTERTOPS
<br />AND FORM SEAMS TO COMPLY WITH MANUFACTURER'S WRITTEN
<br />RECOMMENDATIONS USING ADHESIVE IN COLOR TO MATCH
<br />COUNTERTOP. CAREFULLY DRESS JOINTS SMOOTH, REMOVE
<br />SURFACE SCRATCHES, AND CLEAN ENTIRE SURFACE.
<br />2. INSTALL COUNTERTOPS WITH NO MORE THAN 1/8 INCH IN 96 INCH
<br />(3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A
<br />STRAIGHT LINE.
<br />3. SECURE COVED BACKSPLASHES TO TOPS PER MANUFACTURES
<br />FABRICATION MANUAL AND TO WALLS WITH ADHESIVE.
<br />4. CALK SPACE BETWEEN BACKSPLASH AND WALL WITH SEALANT
<br />SPECIFIED IN DIVISION 7 SECTION "JOINT SEALANTS."
<br />END OF SECTION 064000
<br />WOOD AND PLASTICS (CONTINUED)
<br />SECTION 064400 - PLASTIC PANELING
<br />PART 1-GENERAL
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES THE FOLLOWING:
<br />1. GLASS -FIBER REINFORCED PLASTIC (FRP) WALL PANELING.
<br />2. MOLDING, ADHESIVES, AND JOINT SEALANTS.
<br />1.2 PLASTIC SHEET PANELING
<br />A. GLASS -FIBER -REINFORCED PLASTIC PANELING: GELCOAT-FINISHED,
<br />GLASS -FIBER REINFORCED PLASTIC PANELS COMPLYING WITH ASTM D 5319.
<br />1. LOW -EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE
<br />TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA
<br />DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE
<br />TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS
<br />SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
<br />2. NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES.
<br />3. COLOR: WHITE.
<br />4. MOLDING COLOR: WHITE.
<br />5. SURFACE FINISH: MOLDED PEBBLE TEXTURE.
<br />B. UNREINFORCED POLYPROPYLENE PANELING: SOLID POLYPROPYLENE
<br />PANELS MADE FROM NO LESS THAN 80 PERCENT RECYCLED MATERIAL.
<br />1. LOW -EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE
<br />TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA
<br />DEPARTMENT OF PUBLIC HEALTH'S (FORMERLY, THE CALIFORNIA
<br />DEPARTMENT OF HEALTH SERVICES') "STANDARD METHOD FOR THE
<br />TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL
<br />EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL
<br />CHAMBERS."
<br />2. NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES.
<br />3. COLOR: WHITE.
<br />4. MOLDING COLOR: WHITE.
<br />5. SURFACE FINISH: MOLDED PEBBLE TEXTURE.
<br />1.3 ADHESIVES
<br />A. AS RECOMMENDED BY PLASTIC PANELING MANUFACTURER.
<br />1. VOC LIMIT: 50 G/L
<br />1.4 ACCESSORIES
<br />A. TRIM ACCESSORIES: MANUFACTURER'S STANDARD ONE-PIECE VINYL
<br />EXTRUSIONS DESIGNED TO RETAIN AND COVER EDGES OF PANELS.
<br />PROVIDE DIVISION BARS, INSIDE CORNERS, OUTSIDE CORNERS, AND CAPS
<br />AS NEEDED TO CONCEAL EDGES.
<br />1. COLOR: WHITE.
<br />END OF SECTION 064400
<br />THERMAL AND MOISTURE PROTECTION
<br />SECTION 07841 - THROUGH -PENETRATION FIRESTOP SYSTEMS
<br />1.1 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
<br />1.2 QUALITY ASSURANCE
<br />A. INSTALLER QUALIFICATIONS: AN FM GLOBAL -APPROVED FIRESTOP
<br />CONTRACTOR OR A UL-QUALIFIED FIRESTOP CONTRACTOR.
<br />B. FIRE -TEST -RESPONSE CHARACTERISTICS: TESTED PER ASTM E 814 BY
<br />QUALIFIED TESTING AND INSPECTING AGENCY.
<br />1.3 PENETRATION FIRESTOPPING
<br />A. PENETRATIONS IN FIRE -RESISTANCE -RATED WALLS: F-RATINGS PER
<br />ASTM E 814 OR UL 1479.
<br />B. PENETRATIONS IN HORIZONTAL ASSEMBLIES: F- AND T-RATINGS PER
<br />ASTM E 814 OR UL 1479:
<br />C. PENETRATIONS IN SMOKE BARRIERS: L-RATINGS PER UL 1479.
<br />D. W-RATINGS: PER UL 1479.
<br />E. VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND
<br />SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC
<br />CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D
<br />(EPA METHOD 24):
<br />1. SEALANTS: 250 G/L.
<br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L.
<br />3. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L.
<br />1.4 INSTALLATION
<br />A. IDENTIFICATION: PREPRINTED METAL OR PLASTIC LABELS, PERMANENTLY
<br />ATTACHED.
<br />1.5 FIELD QUALITY CONTROL
<br />A. INSPECTION OF INSTALLED FIRESTOP SYSTEMS: BY OWNER -ENGAGED
<br />AGENCY ACCORDING TO ASTM E 2174 REQUIREMENTS.
<br />END OF SECTION 07841
<br />SECTION 078446 - FIRE -RESISTIVE JOINT SYSTEMS
<br />1.1 SUMMARY
<br />A. FIRE -RESISTIVE JOINT SYSTEMS FOR THE FOLLOWING:
<br />1. JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED CONSTRUCTIONS.
<br />2. JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS.
<br />3. JOINTS IN SMOKE BARRIERS.
<br />1.2 PERFORMANCE REQUIREMENTS
<br />A. FIRE -RESISTANCE RATINGS OF JOINT SYSTEMS IN AND BETWEEN FIRE -
<br />RESISTANCE -RATED CONSTRUCTIONS: EQUALING OR EXCEEDING THE
<br />FIRE -RESISTANCE RATINGS OF CONSTRUCTION THAT THEY JOIN, [AND WITH
<br />MOVEMENT CAPABILITIES INDICATED] AS DETERMINED BY UL 2079.
<br />1.3 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
<br />1.4 QUALITY ASSURANCE
<br />A. FIRE -TEST -RESPONSE CHARACTERISTICS: TESTED BY QUALIFIED TESTING
<br />AND INSPECTING AGENCY.
<br />1.5 FIRE -RESISTIVE JOINT SYSTEMS
<br />A. DESIGNATION SYSTEM FOR JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED
<br />CONSTRUCTIONS: ALPHANUMERIC SYSTEMS LISTED IN UL'S "FIRE
<br />RESISTANCE DIRECTORY" UNDER PRODUCT CATEGORY XHBN.
<br />B. JOINTS IN OR BETWEEN FIRE -RESISTANCE -RATED CONSTRUCTION: EQUAL TO
<br />OR EXCEEDING THE FIRE -RESISTANCE RATING OF CONSTRUCTION THEY WILL
<br />JOIN.
<br />C. JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS: EQUAL TO OR
<br />EXCEEDING THE FIRE -RESISTANCE RATING OF THE FLOOR ASSEMBLY.
<br />D. JOINTS IN SMOKE BARRIERS:
<br />1. L-RATING: NOT EXCEEDING 5.0 CFM/FT (0.00775 CU. M/S X M) OF JOINT
<br />AT 0.30 INCH WG (74.7 PA) AT BOTH AMBIENT AND ELEVATED
<br />TEMPERATURES.
<br />E. EXPOSED FIRE -RESISTIVE JOINT SYSTEMS: PROVIDE PRODUCTS WITH
<br />FLAME -SPREAD AND SMOKE -DEVELOPED INDEXES OF LESS THAN 25 AND 450,
<br />RESPECTIVELY, AS DETERMINED PER ASTM E 84.
<br />F. VOC CONTENT: FIRE -RESISTIVE JOINT SYSTEM SEALANTS SHALL COMPLY
<br />WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED
<br />ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24):
<br />1. ARCHITECTURAL SEALANTS: 250 G/L.
<br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L.
<br />G. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L.
<br />H. ACCESSORIES: FORMING MATERIALS AND OTHER COMPONENTS NEEDED
<br />TO INSTALL FILL MATERIALS AND MAINTAIN RATINGS REQUIRED.
<br />END OF SECTION 078446
<br />THERMAL AND MOISTURE PROTECTION (CONT)
<br />SECTION 079200 - JOINT SEALANTS
<br />1.1 MATERIALS
<br />A. VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND
<br />SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC
<br />CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D
<br />(EPA METHOD 24):
<br />1. SEALANTS: 250 G/L.
<br />2. SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L.
<br />3. SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L.
<br />B. SUITABILITY FOR CONTACT WITH FOOD: WHERE SEALANTS ARE INDICATED
<br />FOR JOINTS THAT WILL COME IN REPEATED CONTACT WITH FOOD, PROVIDE
<br />PRODUCTS THAT COMPLY WITH 21 CFR 177.2600.
<br />C. ELASTOMERIC JOINT SEALANTS: LIQUID APPLIED, CHEMICALLY CURING;
<br />ASTM C 920.
<br />1. MULTICOMPONENT NONSAG NEUTRAL -CURING SILICONE SEALANT
<br />ES-1.
<br />2. SINGLE -COMPONENT MILDEW -RESISTANT NEUTRAL -CURING
<br />SILICONE SEALANT ES-2.
<br />3. SINGLE -COMPONENT MILDEW -RESISTANT ACID -CURING SILICONE
<br />SEALANT ES-3.
<br />4. SINGLE -COMPONENT MILDEW -RESISTANT ACID -CURING RTV
<br />SILICONE SEALANT ES-4.
<br />5. MULTICOMPONENT NONSAG POLYUREA SEALANT ES-5.
<br />6. MULTICOMPONENT NONSAG POLYUREA FILLER ES-6.
<br />D. LATEX SEALANT LS-1: COMPLY WITH ASTM C 834, TYPE P, GRADE NF.
<br />E. JOINT -SEALANT BACKING:
<br />1.2 JOINT -SEALANT SCHEDULE
<br />A. JOINT -SEALANT APPLICATION JS-1: EXTERIOR HORIZONTAL NONTRAFFIC
<br />AND TRAFFIC ISOLATION AND CONTRACTION JOINTS IN CAST -IN -PLACE
<br />CONCRETE SLABS.
<br />1. JOINT SEALANT: ES-5.
<br />B. JOINT -SEALANT APPLICATION JS-2: EXTERIOR PERIMETER JOINTS BETWEEN
<br />WALL AND FRAMES OF DOORS AND WINDOWS.
<br />1. JOINT SEALANT: ES-1.
<br />C. JOINT -SEALANT APPLICATION JS-3: EXTERIOR CONTROL AND EXPANSION
<br />JOINTS IN HORIZONTAL TRAFFIC SURFACES OF BRICK PAVERS, CERAMIC
<br />TILE, STONE PAVING UNITS, CONCRETE TILE.
<br />1. JOINT SEALANT: MULTICOMPONENT POURABLE POLYSULFIDE
<br />SEALANT.
<br />2. JOINT -SEALANT COLOR: AS SELECTED BY ARCHITECT FROM
<br />MANUFACTURER'S FULL RANGE.
<br />D. JOINT -SEALANT APPLICATION JS-4: INTERIOR PERIMETER JOINTS OF
<br />EXTERIOR OPENINGS.
<br />1. JOINT SEALANT: ES-3.
<br />E. JOINT -SEALANT APPLICATION JS-5: INTERIOR CERAMIC TILE EXPANSION,
<br />CONTROL, CONTRACTION, AND ISOLATION JOINTS IN HORIZONTAL TRAFFIC
<br />SURFACES.
<br />1. JOINT SEALANT: ES-3.
<br />2. JOINT -SEALANT COLOR: AS NOTED.
<br />F. JOINT -SEALANT APPLICATION JS-6: INTERIOR JOINTS BETWEEN PLUMBING
<br />FIXTURES AND ADJOINING WALLS, FLOORS, AND COUNTERS.
<br />1. JOINT SEALANT: ES-3.
<br />2. JOINT -SEALANT COLOR: TRANSLUCENT.
<br />G. JOINT -SEALANT APPLICATION JS-7: VERTICAL JOINTS ON EXPOSED
<br />SURFACES OF INTERIOR PARTITIONS.
<br />1. JOINT SEALANT: ES-3.
<br />H. JOINT -SEALANT APPLICATION JS-8: PERIMETER JOINTS BETWEEN INTERIOR
<br />WALL SURFACES AND FRAMES OF INTERIOR DOORS, WINDOWS.
<br />1. JOINT SEALANT: ES-3.
<br />I. JOINT -SEALANT APPLICATION JS-9: HVAC JOINTS.
<br />1. JOINT SEALANT: ES-2.
<br />2. JOINT -SEALANT COLOR: ALUMINUM.
<br />J. JOINT -SEALANT APPLICATION JS-10: NON -POROUS MATERIAL TO
<br />NON -POROUS MATERIAL.
<br />1. JOINT SEALANT: ES-4.
<br />2. JOINT -SEALANT COLOR: CLEAR.
<br />END OF SECTION 079200
<br />DOORS AND WINDOWS
<br />SECTION 081416 - FLUSH WOOD DOORS
<br />1.1 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF DOOR INDICATED. INCLUDE DETAILS
<br />OF CORE AND EDGE CONSTRUCTION AND TRIM FOR OPENINGS.
<br />B. SHOP DRAWINGS: INDICATE LOCATION, SIZE, AND HAND OF EACH DOOR;
<br />ELEVATION OF EACH KIND OF DOOR; CONSTRUCTION DETAILS NOT
<br />COVERED IN PRODUCT DATA; LOCATION AND EXTENT OF HARDWARE
<br />BLOCKING; AND OTHER PERTINENT DATA.
<br />1. INDICATE DIMENSIONS AND LOCATIONS OF MORTISES AND HOLES
<br />FOR HARDWARE.
<br />2. INDICATE DIMENSIONS AND LOCATIONS OF CUTOUTS.
<br />3. INDICATE REQUIREMENTS FOR VENEER MATCHING.
<br />4. INDICATE DOORS TO BE FACTORY FINISHED AND FINISH
<br />REQUIREMENTS.
<br />5. INDICATE FIRE -PROTECTION RATINGS FOR FIRE -RATED DOORS.
<br />C. WARRANTY: SAMPLE OF SPECIAL WARRANTY.
<br />1.2 QUALITY ASSURANCE
<br />A. QUALITY STANDARD: AWI.
<br />1. AWI QUALITY CERTIFICATION LABELS OR AN AWI LETTER OF
<br />LICENSING FOR DOORS.
<br />2. WI -CERTIFIED COMPLIANCE CERTIFICATE FOR DOORS AND
<br />INSTALLATION.
<br />B. FIRE -RATED WOOD DOORS: POSITIVE PRESSURE TESTING.
<br />1.3 DOOR CONSTRUCTION, GENERAL
<br />A. LOW -EMITTING MATERIALS: MADE WITH ADHESIVES AND COMPOSITE WOOD
<br />PRODUCTS THAT DO HAVE NO ADDED UREA FORMALDEHYDE.
<br />B. WDMA I.S.1-A PERFORMANCE GRADE: HEAVY DUTY UNLESS OTHERWISE
<br />INDICATED.
<br />1.4 VENEERED -FACED DOORS FOR TRANSPARENT FINISH
<br />A. INTERIOR SOLID -CORE DOORS:
<br />1. CORE: PARTICLEBOARD.
<br />2. CONSTRUCTION: FIVE OR SEVEN PLIES, BONDED.
<br />1.5 PRIMING/FINISHING
<br />A. SHOP PRIMING:
<br />1. DOORS FOR OPAQUE FINISH: ONE COAT OF WOOD PRIMER.
<br />2. DOORS FOR TRANSPARENT FINISH: STAIN AND FIRST COAT OF
<br />FINISH.
<br />B. FACTORY FINISHING: ALL DOORS.
<br />END OF SECTION 081416
<br />DOORS AND WINDOWS (CONTINUED
<br />SECTION 08331 - OVERHEAD COILING DOORS
<br />1.1
<br />1.2 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE AND SIZE OF OVERHEAD COILING DOOR
<br />AND ACCESSORY. INCLUDE THE FOLLOWING:
<br />B. SHOP DRAWINGS: FOR EACH INSTALLATION AND FOR SPECIAL COMPONENTS
<br />NOT DIMENSIONED OR DETAILED IN MANUFACTURER'S PRODUCT DATA.
<br />INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO
<br />OTHER WORK.
<br />1. DETAIL EQUIPMENT ASSEMBLIES AND INDICATE DIMENSIONS,
<br />WEIGHTS, LOADS, REQUIRED CLEARANCES, METHOD OF FIELD
<br />ASSEMBLY, COMPONENTS, AND LOCATION AND SIZE OF EACH FIELD
<br />CONNECTION.
<br />C. SAMPLES FOR INITIAL SELECTION: MANUFACTURER'S FINISH CHARTS
<br />SHOWING FULL RANGE OF COLORS AND TEXTURES AVAILABLE FOR UNITS
<br />WITH FACTORY -APPLIED FINISHES.
<br />1. INCLUDE SIMILAR SAMPLES OF ACCESSORIES INVOLVING COLOR
<br />SELECTION.
<br />D. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF EXPOSED FINISH
<br />REQUIRED, PREPARED ON SAMPLES OF SIZE INDICATED BELOW.
<br />1. CURTAIN SLATS: 12 INCHES (305 MM) LONG.
<br />2. BOTTOM BAR: 6 INCHES (150 MM) LONG.
<br />3. GUIDES: 6 INCHES (150 MM) LONG.
<br />4. BRACKETS: 6 INCHES (150 MM) SQUARE.
<br />5. HOOD: 6 INCHES (150 MM) SQUARE.
<br />E. DELEGATED -DESIGN SUBMITTAL: FOR OVERHEAD COILING DOORS INDICATED
<br />TO COMPLY WITH PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA,
<br />INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED
<br />PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION.
<br />1. DETAIL FABRICATION AND ASSEMBLY OF SEISMIC RESTRAINTS.
<br />2. SUMMARY OF FORCES AND LOADS ON WALLS AND JAMBS.
<br />F. QUALIFICATION DATA: FOR QUALIFIED INSTALLER.
<br />G. SEISMIC QUALIFICATION CERTIFICATES: FOR OVERHEAD COILING DOORS,
<br />ACCESSORIES, AND COMPONENTS, FROM MANUFACTURER.
<br />H. MAINTENANCE DATA: FOR OVERHEAD COILING DOORS TO INCLUDE IN
<br />MAINTENANCE MANUALS.
<br />1.3 PERFORMANCE REQUIREMENTS
<br />A. OPERATION -CYCLE REQUIREMENTS: PROVIDE OVERHEAD COILING GRILLE
<br />COMPONENTS AND OPERATORS CAPABLE OF OPERATING FOR NOT LESS
<br />THAN 50,000 CYCLES AND FOR 25 CYCLES PER DAY.
<br />1.4 DOOR ASSEMBLY
<br />A. GENERAL: FABRICATE OVERHEAD COILING GRILLE CURTAIN CONSISTING OF
<br />A NETWORK OF 5/16 INCH (8 MM) MINIMUM DIAMETER HORIZONTAL RODS, OR
<br />RODS COVERED WITH TUBE SPACERS, SPACED AS INDICATED.
<br />INTERCONNECT RODS BY VERTICAL LINKS APPROXIMATELY 5/8 INCH (16 MM)
<br />WIDE, SPACED AS INDICATED AND ROTATING ON RODS.
<br />1. SPACE RODS AT APPROXIMATELY 1-1/2 INCHES (38 MM) O.C.
<br />2. SPACE LINKS APPROXIMATELY 9 INCHES (228 MM) APART IN A
<br />STRAIGHT IN -LINE PATTERN.
<br />3. ALUMINUM GRILLE CURTAIN: ASTM B 221(ASTM B 221M), ALLOY
<br />AND TEMPER RECOMMENDED BY ALUMINUM PRODUCER AND
<br />FINISHER FOR TYPE OF USE AND FINISH INDICATED.
<br />B. HOOD: ALUMINUM.
<br />C. MANUAL DOOR OPERATOR.
<br />1.5 INSTALLATION
<br />A. FACTORY -AUTHORIZED REPRESENTATIVE TO [PERFORM STARTUP SERVICE
<br />AND TESTING] [AND] [TRAIN OWNER'S PERSONNEL].
<br />END OF SECTION 08331
<br />SECTION 08345 - DOUBLE ACTING SWING DOORS
<br />PART 1- GENERAL
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1. SOLID -CORE DOUBLE ACTING SWING DOORS WITH PLASTIC
<br />LAMINATE FACES.
<br />1.2 SUBMITTALS
<br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE
<br />CONSTRUCTION DETAILS, MATERIAL DESCRIPTIONS, CORE
<br />DESCRIPTIONS, FIRE -RESISTANCE RATING, TEMPERATURE -RISE
<br />RATINGS, AND FINISHES.
<br />B. SHOP DRAWINGS: INCLUDE THE FOLLOWING:
<br />1. ELEVATIONS OF EACH DOOR DESIGN.
<br />2. DETAILS OF DOORS, INCLUDING VERTICAL AND HORIZONTAL
<br />EDGE DETAILS AND METAL THICKNESSES.
<br />3. FRAME DETAILS FOR EACH FRAME TYPE, INCLUDING
<br />DIMENSIONED PROFILES AND METAL THICKNESSES.
<br />4. LOCATIONS OF REINFORCEMENT AND PREPARATIONS FOR
<br />HARDWARE.
<br />5. DETAILS OF ACCESSORIES.
<br />6. DETAILS OF MOLDINGS, REMOVABLE STOPS, AND GLAZING.
<br />1.3 STANDARD DOUBLE ACTING SWING DOORS
<br />A. GENERAL: PROVIDE DOORS OF DESIGN INDICATED, NOT LESS THAN
<br />THICKNESS INDICATED; FABRICATED WITH SMOOTH SURFACES,
<br />WITHOUT VISIBLE JOINTS OR SEAMS ON EXPOSED FACES UNLESS
<br />OTHERWISE INDICATED. COMPLY WITH ANSI/SDI A250.8.
<br />1. DESIGN: AS INDICATED.
<br />B. CORE CONSTRUCTION: 3/4 INCH (19 MM) EXTERIOR GRADE SOLID WOOD
<br />CORE MADE WITH ADHESIVES AND COMPOSITE WOOD PRODUCTS THAT
<br />DO NOT CONTAIN UREA FORMALDEHYDE.
<br />1. VERTICAL EDGES FOR DOUBLE-ACTING DOORS: ROUND
<br />VERTICAL EDGES WITH 2-1/8 INCH (54 MM) RADIUS.
<br />2. TOP AND BOTTOM EDGES: CLOSED WITH FLUSH OR INVERTED
<br />0.042 INCH (1.0 MM) THICK, END CLOSURES OR CHANNELS OF
<br />SAME MATERIAL AS FACE SHEETS.
<br />3. TOLERANCES: COMPLY WITH SDI 117, "MANUFACTURING
<br />TOLERANCES FOR STANDARD STEEL DOORS AND FRAMES."
<br />C. INTERIOR DOORS: FACE SHEETS FABRICATED FROM DECORATIVE HIGH
<br />PRESSURE LAMINATE. PROVIDE DOORS COMPLYING WITH
<br />REQUIREMENTS INDICATED BELOW BY REFERENCING ANSI/SDI A250.8
<br />FOR LEVEL AND MODEL AND ANSI/SDI A250.4 FOR PHYSICAL
<br />PERFORMANCE LEVEL:
<br />1. LEVEL 1 AND PHYSICAL PERFORMANCE LEVEL C
<br />(STANDARD DUTY).
<br />a. WIDTH: AS INDICATED ON DRAWINGS.
<br />D. HARDWARE REINFORCEMENT: FABRICATE ACCORDING TO
<br />ANSI/SDI A250.6 WITH REINFORCING PLATES OF 18 GAUGE STAINLESS
<br />STEEL
<br />E. FABRICATE CONCEALED STIFFENERS AND HARDWARE REINFORCEMENT
<br />FROM EITHER COLD- OR HOT -ROLLED STEEL SHEET.
<br />1.4 STOPS AND MOLDINGS
<br />A. MOLDINGS FOR GLAZED LITES IN DOORS:
<br />MINIMUM 0.032 INCH (0.8 MM) THICK.
<br />B. LOOSE STOPS FOR GLAZED LITES IN FRAMES:
<br />MINIMUM 0.032 INCH (0.8 MM) THICK, FABRICATED FROM SAME MATERIAL
<br />AS FRAMES IN WHICH THEY ARE INSTALLED.
<br />1.5 STEEL FINISHES
<br />A. PRIME FINISH: APPLY MANUFACTURER'S STANDARD PRIMER
<br />IMMEDIATELY AFTER CLEANING AND PRETREATING.
<br />1. SHOP PRIMER: MANUFACTURER'S STANDARD, FAST -CURING,
<br />LEAD- AND CHROMATE -FREE PRIMER COMPLYING WITH
<br />ANSI/SDI A250.10 ACCEPTANCE CRITERIA; RECOMMENDED BY
<br />PRIMER MANUFACTURER FOR SUBSTRATE; COMPATIBLE WITH
<br />SUBSTRATE AND FIELD -APPLIED COATINGS DESPITE
<br />PROLONGED EXPOSURE.
<br />B. FACTORY -APPLIED PAINT FINISH: MANUFACTURER'S STANDARD,
<br />COMPLYING WITH ANSI/SDI A250.3 FOR PERFORMANCE AND
<br />ACCEPTANCE CRITERIA.
<br />1.6 COLOR AND GLOSS: AS INDICATED BY MANUFACTURER'S DESIGNATIONS.
<br />END OF SECTION 08345
<br />STARBUCKS
<br />2401 UTAH AVENUE SOUTH
<br />SEATTLE, WASHINGTON 98134
<br />(206) 318-1575
<br />THESE DRAWINGS AND SPECIFICATIONS ARE
<br />CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br />PROPERTY OF STARBUCKS CORPORATION,
<br />WHICH IS THE OWNER OF THE COPYRIGHT IN
<br />THIS WORK. THEY SHALL NOT BE
<br />REPRODUCED (IN WHOLE OR IN PART), SHARED
<br />WITH THIRD PARTIES OR USED IN ANY MANNER
<br />ON OTHER PROJECTS OR EXTENSIONS TO THIS
<br />PROJECT WITHOUT THE PRIOR WRITTEN
<br />CONSENT OF STARBUCKS CORPORATION.
<br />THESE DRAWINGS AND SPECIFICATIONS ARE
<br />INTENDED TO EXPRESS DESIGN INTENT FOR A
<br />PROTOTYPICAL STARBUCKS STORE (WHICH IS
<br />SUBJECT TO CHANGE AT ANYTIME) AND DO
<br />NOT REFLECT ACTUAL SITE CONDITIONS.
<br />NEITHER PARTY SHALL HAVE ANY OBLIGATION
<br />NOR LIABILITY TO THE OTHER (EXCEPT STATED
<br />ABOVE) UNTIL A WRITTEN AGREEMENT IS
<br />FULLY EXECUTED BY BOTH PARTIES.
<br />STARBUCKS TEMPLATE VERSION 2018.01.26
<br />I - 0 1•
<br />700 W. Pete Rose Way, Suite 460 Donald J. Rothman I
<br />Cincinnati, OH 45203 Architect In Charge
<br />Tel: (513) 421-2210 License: AR0017303
<br />Design Forum
<br />Engineering
<br />700 W. Pete Rose Way, Suite 460 Timothy L Raberding, PE
<br />Cincinnati, OH 45203 Professional Engineer
<br />Tel: (513) 421-2210 License: 62078
<br />APoFF`O�o N 2 5 2018
<br />Ak C.
<br />D J: RETtio ', 9
<br />N0
<br />L.J.
<br />L.J..
<br />W
<br />r�
<br />V
<br />M
<br />W 06
<br />Ir-
<br />Z O
<br />w rrCO^
<br />0 vJ
<br />d D
<br />M
<br />(`M
<br />C) LL
<br />W J J
<br />LU J
<br />J =
<br />Q Q
<br />U
<br />W O
<br />a �N
<br />(STORE #: 56350 I
<br />PROJECT #: 81186-001
<br />ISSUE DATE: 06/22/18
<br />DESIGN PROGRAM ROMINA VIGNOLO
<br />MANAGER:
<br />LEEDO AP:
<br />PRODUCTION DESIGNER: MICHAEL.B.SARKA
<br />ICHECKED BY- M. MCCAUGHEY
<br />Revision Schedule
<br />Rev Date By Description
<br />SHEET TITLE:
<br />CONSTRUCTION
<br />SPECIFICATIONS
<br />SCALE: NO SCALE
<br />SHEET NUMBER:
<br />G-012
<br />
|