Laserfiche WebLink
T _.; 0!1 bk ,!_. 1 !:::'_ 1, l.'_: I... <br />1 <br />PROJECT NV TE a <br />E el <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE 2014 EDITION OF THE NATIONAL <br />ELECTRICAL CODE (N.E.C) AND ALL LOCAL CODES AND ORDINANCES. <br />E 2. ALL MATERIALS SHALL BE NEW AND OF DOMESTIC ORI61N AND SHALL BEAR UNDERWRITERS' <br />LABEL WHERE APPLICABLE. <br />3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A <br />FIR5T-CLA55 WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND <br />ACCEPTANCE OF THIS 5Y5TEM BY THE EN&INEI R/ARCHITECT MUST BE A CONDITION OF THE SUB <br />CONTRACT. <br />4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AV011,7 INTERFERENCE WITH THE <br />PROGRE55 OF CONSTRUCTION, <br />5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMAN5HIP FREE FROM DEFECTS FOR A <br />A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE, <br />L 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL GHAR6E AND TO <br />INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY <br />HAVE BEEN DAMAGED THEREBY. <br />'I. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION A6AIN5T PUBLIC, LIABILITY OF <br />PROPERTY DAMAGE FOR THE DURATION OF THE WORK. <br />5. CONTRACTOR TO PAY FOR ALL PERMITS, UTILITY FEES, INSPECTIONS AND TE5TIN6. <br />q. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND <br />TELEPHONE COMPANIES. <br />10. MINIMUM WIRE 51ZE SHALL 13E #12 AHG, EXGLUDINC CONTROL HIRINCa. UNLESS OTHERHI5E NOTED, <br />CONDUGTOR5 SHALL BE COPPER WITH THHN/THHN INSULATION. CONDUCTOR5 #12 AND SMALLER <br />MAY BE 50UD; ALL THOSE #10 AND LARGER TO BE STRANDED. <br />II. ALL UNDER t ROUND RAGEWAY5 SHALL BE OALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 <br />PVC. ALL OTHER RACEHAY5 TO COMPLY WITH C60VERNIN6 CODES. MINIMUM CONDUIT <br />UNDER AROUND SHALL BE 3/4" CONDUIT UNLE55 OTHERH15E NOTED. <br />12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED <br />HUB5 IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED <br />AREAS. ALL BOXES SHALL BE RECESSED (FLUSH) IN HALLS OR GEILIN65 WHENEVER POSSIBLE. <br />B. DISCONNECT 5HITCHE5 SHALL BE H.P. RATED, GENERAL OR HEAVY DUTY WHERE INDICATED, <br />QUICK -MAKE, QUICK -BREAK TYPE. ENCL05URI5 SHALL BE AS REQUIRED BY N.E.C. AND <br />LOCATION (WEATHERPROOF, EXPLOSION- PROOF, ETC). <br />14. ALL GENERAL PURPOSE 5HITCHE5 AND RECEPTACLE5 SHALL BE THE PRODUCT OF A 51NOLE <br />MANUFACTURER. CATALOG NUMBERS LISTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES <br />BY HUBBELL, PASS 4 SEYMOUR, OR ARROW HART HILL BE ACCEPTED. COLOR OF DEVICES AND <br />PLATES SHALL BE AS DICTATED BY ARCHITECT/OWNER. <br />A. 5WITCHE5: #1221-2 5ERI1-5. <br />B. RECEPTACLES: #5362 SERIES. <br />C. COVER PLATES: SMOOTH PLASTIC <br />NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. <br />15. ALL RACEWAYS AND PIPES, SPACED IN OR THROUGH ANY CONCRETE 5LAB, SHALL BE SPACED <br />A MINIMUM OF THREE TIMES THE DIAMETER OF THE LAR65E5T RACEWAY. <br />16. IT 15 NOT THE INTENT OF THESE PLANS TO 5HOH EVERY MINOR DETAIL OF CONSTRUCTION. THE <br />CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL <br />SYSTEM, AND PROVIDE ALL NECE55ARY DEVICES AND GOMPONENT5 FOR EQUIPMENT TO BE <br />PLACED IN PROPER HORKIN6 ORDER. <br />I-1. ALL ELECTRICAL RACEWAYS (METALLIC AND NONMETALLIC) SHALL HAVE AN EQUIPMENT <br />GROUND CONDUCTOR 51ZED IN ACCORDANCE HITH THE 2014 EDITION OF THE N.E.C. <br />0. LOAD DATA IS BASED ON INFORMATION GIVEN ENGINEER AT THE TIME OF DESIGN. VERIFY ALL <br />EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. <br />19. CIRCUITS 5HOHN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE <br />CONTRACTOR IS TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. <br />20. FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING, AND CONNECTIONS ON AIR CONDITIONING <br />SYSTEM AS SHOWN ON PLANS. ELECTRICAL GONTRACTOR SHALL VERIFY AND COORDINATE WITH <br />MECHANICAL CONTRACTOR RE6ARDIN6 SUPPLY AND INSTALLATION OF ALL REQUIRED <br />CONTROLS. <br />21. ALL 5HITCH6EAR SHALL BE THE PRODUCT OF A SINGLE MANUFACTURI=R. 5Y5TEM DE516N 15 <br />BA5ED ON THE SQUARE "D" COMPANY, HOWEVER, COMPARABLE EQUIPMENT BY EATON, G.E., AND <br />SIEMENS HILL BE ACCEPTABLE. TANDEM AND HALF-5PAGE CIRCUIT BREAKERS SHALL NOT BE <br />USED. PROVIDE ARC FLASH WARNING 516NA6E PER N.E.G. 110.16 FOR ALL SWITCHBOARDS AND <br />PANELS. <br />22. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RI61D STEEL. ELBOWS AND RI61D STEEL <br />SECTIONS AT SLAB PENETRATIONS. HHERE RIGID STEEL 15 USED, IT SHALL BE COMPLETELY <br />COATED HITH AN ALKALI AND RUST-RE515TANT BITUMA5TIC PAINT, AND THREADS SHALL BE <br />COATED HITH ZING CHROMATE. <br />23. THE EL.ECTRIGAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL UTILITY <br />COMPANIES AT THE 51TE PRIOR TO CONSTRUCTION, AT THAT TIME, THE CONTRACTOR SHALL <br />COORDINATE ALL RELATED HORK HITH THE UTILITY COMPANIES' REPRESENTATIVES TO MEET <br />THE OWNER'S SCHEDULE. <br />24. ALL ELECTRICAL GONDUCTOR5 SHALL BE INSTALLED IN AN APPROVED RAGEHAY. <br />25. CONTRACTOR SMALL BE RESPONSIBLE FOR 5EALING ALL CONDUIT PENETRATIONS MADE <br />THROUGH FIRE RATED HALLS, CEILIN65, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L. <br />ASSEMBLY STANDARDS. <br />26. CONDU.IT.SY_5TEM_REQUIREMENTS=_ <br />UNDERGROUND - PVC HITH RIGID c4O THROUGH SLAB. <br />ABOVE FINISH FLOOR, CEILING-6, ETC. (INDOOR) - EMT WITH DIECA5T SET SCREW FITTIN66. <br />GALVANIZED RICAD CONDUITS - ABOVE GRADE AND WHERE SUSCEPTIBLE TO PHYSICAL <br />DAMA6,155. <br />FLEXIBLE CONDUITS - INDOOR, ONLY SHORT RUNS NOT TO EXCEED 6-0" <br />5EALTITE - OUTDOOR, ONLY SHORT RUNS NOT TO EXCEED 6'-0" <br />21. <br />THE FOLLOWING APPLICABLE COLOR CODES SHALL BE IMPLEMENTED AND P05TED IN ALL <br />PANELS, DISCONNECT SHITCHE5, ETC., PER NEC ARTICLES 200.6(D) AND 215.12, <br />120/205V., 3--PH. <br />PHASE 'A' BLACK <br />PHASE 'B' RED <br />PHASE 'G' BLUE <br />NEUTRAL WHITE <br />GROUND GREEN <br />150L. GROUND 6REEN/YELLOH <br />28. CFI RECEPTACLES <br />ALL RECEPTACLES WITHIN 51X FEET OF A HATER SOURCE SHALL BE A 6FI RECEPTACLE OR <br />PROTECTED BY A 6FI BREAKER PER NFPA 10 (NEC) ARTICLE 210b. THIS NOTE APPLIE5 TO <br />ALL SHEETS. <br />2Q. PROVIDE ALL REQUIRED O-IOV WIRING TO O-IOV DIMMABLE FIXTURES AND CONTROLS AS <br />REQUIRED. THI5 O--IOV LOW VOLTAGE HIRING IS NOT 5HOHN ON PLANS FOR DRAWING CLARITY. <br />30. ALL OUTDOOR RECEPTACLES SHALL BE HEATHER RE-515TANCE RATED, CGF{-TYPE WITH "HET <br />WHILE IN USE" COVERS. <br />31. WHERE HIRE SIZES ARE SHORN ON PLANS OR IN PANEL SCHEDULE, THE SAME HIRE SIZE, A5 A <br />MINIMUM, SHALL BE CARRIED THROUGHOUT THE CIRCUIT UNLE55 5PECIFICAL.LY NOTED <br />OTHERWISE ON PLANS. <br />NqD <br />MG GABLE NOTES <br />._ . <br />• BRANCH CIRCUITS MAY BE METAL CLAD GABLE TYPE (MG), PROVIDED: <br />• WHERE PANEL 15 FLUSH MOUNTED <br />THE CABLE SHALL RUN IN WALL CAVITY. <br />WHERE PANL I5W-9 AGF MOUE. <br />CONTRACTOR SHALL PROVIDE METAL STUDS WITH DRYWALL TO <br />CREATE A CAVITY TO RUN THE MC GABLE WITHIN. <br />• MG CABLE MAY BE USED FOR 20 AMP CIRCUITS IN WALLS OR ABOVE <br />ACGE551BLE CEILINGS. <br />• MC: CABLE WIRE GAUCP5 SHALL BE AS 5HOWN ON PANEL SCHEDULE. <br />• MC GABLE SHALL ONLY BE USED WHERE ALLOWED BY N.E.C. SECTION <br />330.10, WHERE APPROVED BY THE BUILDING OFFICIAL, AND ACCEPTED <br />BY THE OHNERR. <br />« MC CABLE SHALL BE INSTALLED PER N.E.G. 350. <br />• ALL GABLE RUNS SHALL BE CONCEALED FROM VIEW AND ROUTED <br />PARALLEL AND PERPENDICULAR TO BUILDING LINES. <br />• MG CABLE MAY NOT BE USED IN OPEN STRUCTURE AREA, EXPOSED, OR <br />OTHERWISE V151BLE TO CUSTOMERS. <br />• NO MC GABLE CAN BE USED IN DAMP OR WET LOCATIONS. <br />N43B <br />2017 FLORIDA BUILDING CODE, ENERGY CONSERVATION (6TH EDITION) <br />SECTION C405.6 ELECTRIC POWER <br />6405b.3 VOLTAGE DROP <br />THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE <br />SIZED FOR A MAXIMUM OF 5 % VOLTAGE DROP TOTAL. <br />G405.6.4.1 QRAHINGS <br />CONSTRUCTION DOCUMENTS HEREBY REQUIRE THAT WITHIN 30 DAYS AFTER. <br />THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL <br />INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER., INGLUDING: <br />I. A 51N6LE-LINE D{ACRAM OF THE BUILDING ELECTRICAL DISTRIBUTION <br />SYSTEM. <br />2. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL <br />DISTRIBUTION. <br />0405.6.4.2 MANUAL5 <br />CONSTRUCTION DOCUMENTS HEREBY REQUIRE THAT AN OPERATING MANUAL <br />AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OHNER. THE <br />MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: <br />1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS <br />FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. <br />2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF <br />EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE <br />ACTIONS SHALL BE CLEARLY IDENTIFIED. <br />3. NAMES AND ADDR.E55E5 OF AT LEAST ONE QUALIFIED SERVICE AGENCY. <br />SECTION C408 SYSTEM COMMISSIONING <br />G40& 3.1 FUNCTIONAL TE5TING: <br />I. PRIOR TO PA551N6 FINAL INSPECTION, THE RE615TERED DESIGN <br />FROFE55IONAL SHALL PROVIDE EVIDENCE THAT THE LIG1-1TIN6 CONTROL <br />SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND <br />5OFTHARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER <br />WORKING CONDITION IN ACCORDANCE H1TH THE CONSTRUCTION <br />DOCUMENTS AND MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TESTING <br />SHALL BE IN ACCORDANCE HITH 5ECTIONS G40&.3.1.1 AND 040&3.1.2 FOR <br />THE APPLICABLE CONTROL TYPE. <br />N40A <br />MUTES <br />1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND INTERIOR <br />E ELEVATIONS FOR COORDINATION OF LOCATIONS OF LIC14TIN6 <br />j+�I FIXTURES. <br />� `� 2. (EX) DENOTE-5 EXI5TINC LI&HT FIXTURE OR DEVICE TO REMAIN A5-15. <br />E FIELD VERIFY QUANTITIES AND LOCATIONS. <br />3. (R) DENOTES RELOCATED EXISTING L16HT FIXTURE OR DEVICE. <br />COORDINATE HITH OWNER'S REPRESENTATIVE. <br />A 4. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY <br />SYSTEM INCLUDING WALL 5HITC.HE5 AND FLEXIBLE CONDUIT TO LI&HT <br />L FIXTURES. <br />5. ALL TELEPHONE/DATA/VOICE JACKS AND CABLING TO BE PROVIDED <br />AND INSTALLED BY OTHERS, UNLESS OTHERWISE NOTED ON DRAWINGS. <br />6. REUSE EXI5TIN6 JUNCTION BOXES, CONDUIT AND HIRING HHERE <br />APPLICABLE. REMOVE AND DISPOSE OF ALL UNUSED CONDUIT AND <br />WIRING BACK TO ITS SOURCE. <br />1. CONTRACTOR SHALL REFER TO INTERIOR ARCHITECTURAL DRAHIN05 <br />FOR FOR COORDINATION OF MOUNTING HEIGHTS AND/OR LOCATIONS <br />OF ALL WIRINGS DEVIGE5. <br />8. THE CONTRACTOR 5HALL REMOVE ALL PXISTIN& WIRINC7 AND <br />EQUIPMENT MADE UNNECESSARY BY THE RENOVATION. ALL MATERIALS <br />REMOVED SHALL BE DISPOSED OF BY THE CONTRACTOR. <br />9. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL <br />DEVIGP TYPES, LOCATIONS AND QUANTITIES WITH OHNER'5 <br />REPRESENTATIVE AND PROVIDE AGGORDINOLY. <br />10. LIGHTING 5WITCHE5 SHALL BE GROUPED WITH ONE PLATE AND <br />LOCATED APPROXIMATELY 2 INCHES FROM DOOR FRAME (STRIKE <br />SIDE) UNLF-55 OTHERWI5E NOTED. <br />11. ALL EXPOSED CONDUIT SHALL BE RUN PARALLEL TO OR AT R16HT <br />ANCLE5 TO STRUCTURE. <br />N23B <br />L E V rND <br />E <br />MOUNTING HEI6HT5 SHOWN ARE MAXIMUM/MINIMUM <br />NOT <br />ALL DEVIGE5 5HOHN IN LE6PND ARE REQUIRED. <br />HANDICAPPED ACGE551BILITY 5TANDARD5 - THEY SHALL <br />REVIEW POY�F-R AND LIGHTING PLANS AND DETAILS FOR <br />NOT BE ALTERED WITHOUT WRITTEN AUTHORIZATION. <br />ITEMS WHICH APPLY TO THIS PROJECT. <br />E <br />[Z] <br />LINEAR LIGHT FIXTURE, LETTER INDICATES TYPE <br />E I <br />MAIN 5WITCA-1 OARD <br />G <br />00 <br />DOWN LIGHT FIXTURE, LETTER INDICATE5 TYPE <br />MAIN DISTRIBUTION PANEL <br />T <br />I-0 c <br />WALL BRACKET Li6HT FIXTURE, LETTER INDICATES TYPE <br />O <br />SPECIAL NOTES, SEE PLANS <br />Q <br />1-16HT FIXTURE ON LEMER6l NGY CIRGUIT/NI&HT LIGHT (NL.J <br />r'" �I CONCEALED IN HALL <br />ORS A5 SHOWN ON PANEL SCHEDULE.CEILIN U.O.N. <br />' <br />® <br />EXIT LIGHT (ARROW INDICATES DIRECTION) <br />BATTERY POWERED ENS"ReENGY LIGHT <br />CONDUIT CONCEALED _ BELOW FLOOR <br />SLAB HEUN U.O.N. GRADE <br />f ~ WI CCONDUCTORS AS SHOWN ON PANEL SCHEDULE <br />�j <br />mm <br />�' <br />fU HEAD REMOTE EXTERIOR MOUNTED ENER&ENCY L16HT. <br />'" .,- ._ _. J <br />CONDUIT EXPOSED ON WALL OR CEILING WITH CONDUCTORS AS <br />SHOWN ON PANEL. SCHEDULE. U.O.N. <br />(2) HEAD REMOTE EXTERIOR MOUNTED EMERGENCY 1-1614T. <br />� ``�,� TM-EV15ION 5Y5TEM EMPTY CONDUIT WITH PULL WIRE <br />L <br />FLEXIBLE. CONDUIT NOT TO EXCEED 6 FEET IN L.EN(9TH <br />TRACK L16HTIN6 <br />DG <br />� � D.C. VOLTAGE WIRING 010 WIRE IN 1/2" CONDUIT) <br />5° <br />SINGLE POLE 'SWITCH, LOWLY. CASE LETTER INDICATES LIGHT <br />CONTROLLED, MOULT 46" A.F.F. U.O.N. <br />WIREMOLD (SIZE AND L.EN6TH AS NOTED) <br />S2 <br />DOUBLE POLE SWITCH, MOUNT 46" A.F.F. U.O.N. <br />53 <br />THREE-WAY SWITCH, MOUNT 46" A.F.F. U.O.N. <br />/ <br />CONDUIT SEAL -OFF FITfIN6 <br />S4 <br />POUR -WAY SWITCH, MOUNT 46" A.F.F. U.O.N. <br />PADDLE FAN WITH BACKBOX CAPABLE OF 5UPPORTIN6 100 LB. <br />Sp <br />SIN6L E POLE SWITCH WITH PILOT LIGHT, MOUNT 4&" A.F.F. <br />LOAD <br />U.O.N. <br />5K <br />KEY OPERATED 5IN6L.E POLE SWITCH, MOUNT 46" A.F.F. U.O.N. <br />c:m <br />T.V. CAMERA <br />Sr <br />FAN CONTROLLER, MOUNT 46" A.F.F. U.O.N. <br />0 <br />T.V. MONITOR <br />S° <br />DIMMER SWITCH, WATTS A5 NOTED, MOUNT 46" A.F.F. U.O.N. <br />TELEVISION OUTLET, PROVIDE SINGLE 5AN& BOX WITH 3/4" <br />CONDUIT WITH PULL WIRE AND INSULATING BU"SHIN6 STUBBED INTO <br />SINGLE RECEPTACLE, AMPS AS NOTED, MOUNT lb" A.F.F. <br />CEILING SPACE. MOUNT BOX 0" A.F.F. U.Q.N. <br />U.O.N. <br />G.- <br />DUPLEX RECEPTACLE, MOUNT Ib" A.F.F. U.U.N. <br />`© <br />DISCONNECT 5WITCH <br />DUPLEX RECEPTACLE, MOUNT A50VE COUNTER HEIGHT U.O.N. <br />DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NP' INDICATES <br />NON -FUSED; "PE" INDICATES DUAL ELEMENT FUSES. <br />G�JADRAPLEX RECEPTACLE, MOUNT IB" A.F.F. U.O.N. <br />MAGNETIC MOTOR STARTER <br />! <br />DUPLEX RECEPTACLE, HORIZONTALLY MOUNTED. <br />`o <br />COMBINATION MACPNETIC MOTOR 5TARTER/0I5CONNECT SWITCH <br />OoA <br />I PH, 25OV. RECEPTACLE, AMPS AS NOTED, MOUNT lid" A.F.F. <br />FT1 <br />DRY TYPE TRANSFORMER <br />U.O.N. <br />0-1 <br />SPECIAL RECEPTACLE AS NOTED <br />® <br />CONTACTOR (A5 NOTED) <br />Q <br />FLOOR MOUNTED DUPLEX RECEPTACLE <br />T;G <br />TIME CLOCK <br />em <br />e4ZOLAVL7 FAULT INTERRUPTER RECEPTACLE, LEVITON ik78g4--R, <br />r�ic <br />PHOTOCELL. <br />MOUNT ABOVE COUNTER HEIGHT U.O.N. <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />I a. <br />DUPLEX RECEPTACLE, 150L.ATW 6ROUNP TYPE, LEVITON <br />05362-161 MOUNT AT 15" A.F.F. U.O.N. <br />ELECTRIC DUCT HEATER. <br />I: <br />DUPLEX RECEPTACLE, SPLIT WIRED, MOUNT IB" A.F.F. U.O.N. <br />THERMOSTAT. PROVIDE EaAN6 BOX WITH C. BBIED <br />WwPt <br />DUPLEX RECEPTACLE, WEATHER-RE'515TANT AND 6FI RATED, <br />Q <br />MOSINUNT <br />INTO Ci=1LIN6 SPACE, MOUNT 60" A.F.F. UA.N. !COORDINATE WITH <br />RD E WITH <br />LEVITON vW`iMq-TRpK WITH WEATHERPROOF BOX AND <br />MECHANICAL DRAWIN65 PRIOR TO RG H-•IN) <br />COVER. MOUNT AT IV' A.F.F. U.O.N. <br />PUSHBUTTON, MOUNT 45" A.F.F. U.O.N. <br />DUPLEX OUTLET WITH USB CONNECTION. LEVITON *T832 <br />(WITH COLOR TO MATCH OTHER DEVICE5 IN THE AREA). <br />DOOR CHIME WITH TRANSFORMER <br />TELE/DATA OUTLET, PROVIDE 4" SGd. BOX WITH 1--6AN6 MUD <br />O <br />SAKE, <br />RINCY, AND 3/4" CONDUIT WITH PULL WIRE AND IN51JL.ATIN6 <br />BUISHIN& STUBBED INTO CEILING SPACE, MOUNT ABOVE <br />0 <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N) <br />COUNTER HEIGHT U.O.N. <br />TELE/DATA OUTLET, PROVIDE 4" 50, BOX WITH I -GANG MUD <br />■ <br />DEVICE A5 NOTED <br />RING, AND 5/4" CONDUIT WITH PULL WIRE AND INSULATING <br />BU5HIN6 STUBBED INTO CEILING SPACE. MOUNT BOX lap <br />� <br />TELEPHONE BACKBOARD WITH #'6 CU. GROUND (SIZE AS NOTED) <br />A.F.F. UA.N <br />® <br />2TT/46OV, 5-PH PANEL.BOARD <br />V <br />TELEPHONE/ VOICE WALL OUTLET, PROVIDE 4" 50. BOX WITH <br />I-6AN6 MUD RING, AND 3/4' CONDUIT WITH PULL WIRE AND <br />w <br />LIGHTING OR POWER PANELBOARD <br />IN5UL.ATIN6 BUSHII& 5TUBL�EO INTO CEILIN& SPACE. MOUNT <br />BOX I5" A.F.F. U.O.N. <br />$! <br />FLOOR MOUNTED TELEPHONE RECEPTACLE <br />DATA WALL OUTLET, PROVIDE 4' 50. BOX WITH I-6A1e MUD <br />SPLIT CONTROLLED DUPLEX RECEPTACLE WITH (1) OUTLET <br />RING, AND 3/4" CONDUIT WITH PULL WIRE AND IN5UL ATIN& <br />CPS <br />CONTROLLED AND (1) OUTLET CONSTANT HOT. LEVITON #5362-IP <br />BUSIi1149 STUBBED INTO CEILII46 5PACE. MOUNT BOX AT 16" <br />(W/COLOR TO MATCH OTHER DEVICES IN THE AREA), <br />A.F.F. U.O.N. <br />*c4;v <br />QUAD CONTROLLED RECEPTACLE KITH (1) DUPLEX RECEPTACLE <br />CONTROLLED AND (1) DUPLEX RECEPTACLE CONSTANT HOT. <br />LEVITON 0.5362-2P (W/COL.OR TO MATCH OTHER DEVICES- IN <br />AREA). <br />.&M69.1LId't'IQW <br />E.O. i GIUIPMERT GROUND EPC ELECTRIC, HATTER COOLER <br />N.L. <br />N16W L16MT AF.0. A50VE FINISH FADE <br />I.6. ISOLATED 64ROUND E/F-EF EXHAUST FAN <br />PC <br />PULL CHAIN U.O.N. UNLE56 OTHERWISE NOTED <br />WP WEATHI37PROOP A/H-AHU AIR HANDLING UNIT <br />C.T. <br />CURRENT TRANSFORMER N T5. NOT TO 5CALI--- <br />EC EMPTY CONDUIT ACC-CU CONDEN51146 UNIT <br />EX <br />EXISTIN& DEVICE N.I.C. NOT IN CONTRACT <br />EHH ELECTRIC WATER HEATER R U ROOF TOP UNIT <br />ER <br />EXISTING TO BE RELOCATED A.FF. ABOVE FINISH FLOOR <br />6FI/6F0I GROUND FAMT CIRCUIT <br />INTERRUPTER <br />NOTE: MOUNTING HEI60T5 NOTED ARE <br />TO CENTERLINE OF DEVICE SHOWN. U.O.N. <br />01 <br />NOTES <br />I. IT IS THE CONTRACTOR'S RE5PON5151LITY TO REVIEW ALL DRAHIN65 <br />O <br />AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, PLUM311,16, AND ELECTRICAL PRIOR TO <br />N <br />5UBMITTIN6 A BID. <br />T <br />2. REPORT ANY 015CREPANGIE5 TO ARCHITECT OR ENGINEER. PRIOR TO <br />BID. <br />3. BIDDERS ARE TO V151T THE SITE AND FAMILIARIZE THEM5PLVE5 HITH <br />//�� <br />EXI5TINC7 CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE <br />1/"""-� <br />AND SCOPE OF THE HOW. <br />4. IT 15 THE CONTRACTOR-5 RESPONSIBILITY TO VERIFY ALL EXI5TINe 51TE <br />T <br />CONDITIONS INCLUDING BUT NOT LIMITED TO, SERVICE LOCATION, <br />SERVICE LAYOUTS, AND TELEPHONE LOCATION., ETC. <br />0 <br />5. THE 5U5MI5510N OF A BID WILL 13E EVIDENCE THAT 5UCH AN <br />EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, <br />OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES ENCOUNTERED <br />HHIGH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, <br />WILL NOT BE ALLOWED. <br />6. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE <br />ARCHITECT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN <br />EXISTING 51TE CONDITIONS PRIOR TO 505MI55ION OF BID. <br />-f. COORDINATE WITH OTHER TRADES FOR ITEMS IN THEIR SCOPE OF WORK <br />HHICH HOULD REQUIRE ELECTRICAL WORK (DISCONNECTION, <br />RECONNECTION, ETC) AND ARE NOT INDICATED ON ELECTRICAL <br />DRAWIN66. <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS. <br />N35 <br />M2A <br />INDEX <br />EO.0 : <br />ELECTRICAL PROJECT NOTES AND LEGEND <br />H <br />ELO <br />ELECTRICAL SITE PLAN <br />E <br />EH <br />PHOTOMETRIC 51TE PLAN <br />E <br />E1.2 <br />FIXTURE INFORMATION <br />T <br />E2.0 : <br />LIGHTING AND POWER PLANS <br />E3.0 : <br />POHER R151 R DIACRAM <br />E4.0 : <br />ELECTRICAL SPECIFICATIONS <br />CHEHAYE.B & ASSOCIATES, INC. <br />CONSULTING PROFESSIONAL ENGINEERS <br />ct <br />3702 AZEELE ST. (813) 876-1415 <br />TAMPA, FL 33609 (fax) 876-0913 <br />LIC. #49521 SOUHEI M AYEB,, CERT. #7340 <br />