Laserfiche WebLink
2 <br />3 <br />4 <br />E <br />Col <br />C <br />B <br />A <br />L" ', t <br />M� <br />u�► <br />N T N,OTt <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION <br />STANDARDS. <br />CA - COMPRESSED AIR <br />- - <br />= - =AV= - - — <br />- ACID VENT <br />AFF <br />-ABOVE FINISH FLOOR <br />2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. <br />AW <br />-ACID WASTE <br />AVT_— <br />- ACID WASTE <br />AV <br />- ACID VENT <br />3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW <br />— <br />— _ —AW_- - - — <br />- BELOW GROUND ACID WASTE <br />CO2 <br />- CARBON DIOXIDE <br />SURVEYS, <br />AS -BUILT RECORDS AND FIELD INVESTIGATIONS, UNFORSEEN CONDITIONS <br />— — <br />— <br />CO2 <br />- CARBON DIOXIDE <br />CB <br />CD <br />- CATCH BASIN <br />- CONDENSATE DRAIN <br />PROBABLY <br />EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON <br />CFH <br />- CUBIC FEET PER HOUR <br />DRAWINGS. <br />COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS <br />CA—___—_—_ <br />- COMPRESSED AIR <br />CO <br />-CLEANOUT <br />DETERMINED <br />DURING CONSTRUCTION, WILL BE NECESSARY. <br />CD <br />- ABOVE GROUND CONDENSATE DRAIN <br />CONT <br />- CONTINUATION <br />4. FIELD <br />VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, WHICH <br />_ - <br />- - -CD— - = — <br />-BELOW GROUND CONDENSATE DRAIN <br />CW <br />DI <br />- DOMESTIC COLD WATER <br />- DEIONIZED WATER <br />ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF THE NEW <br />DA <br />- DENTAL AIR <br />DN <br />- DOWN <br />WORK. <br />DI <br />- DEIONIZED WATER <br />DS <br />DWG <br />- DOWNSPOUT <br />- DRAWING <br />5. NOTIFY <br />OWNER AT LEAST 72 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. <br />DV <br />-DENTAL VACUUM <br />EXIST <br />-EXISTING <br />SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. <br />OF <br />- DEGREE FAHRENHEIT <br />SERVICES <br />ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR <br />DOMESTIC COLD WATER <br />WORKING HOURS. <br />FCO <br />- FLOOR CLEANOUT <br />DOMESTIC HOT WATER <br />FD <br />- FLOOR DRAIN <br />FOF <br />-FUEL OIL FILL <br />6. PLANS <br />ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS <br />DOMESTIC HOT WATER RETURN <br />FOG <br />- FUEL OIL GAGE <br />NOT <br />INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY <br />FOF <br />- FUEL OIL FILL <br />FOR <br />- FUEL OIL RETURN <br />ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO <br />FO <br />FUEL OIL GAGE <br />FOS <br />- FUEL OIL SUPPLY <br />MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL <br />FOV <br />- FUEL OIL VENT <br />INSTALLATIONS <br />AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID <br />FOR <br />- FUEL OIL RETURN <br />FS <br />- FLOOR SINK <br />INTERFERENCES. <br />FOS <br />- FUEL OIL SUPPLY <br />G <br />-GAS <br />7. PROVIDE <br />ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. <br />GPH <br />- GALLONS PER HOUR <br />�FOV-" - - - <br />-FUEL OIL VENT <br />GPM <br />- GALLONS PER MINUTE <br />G <br />-GAS <br />GR <br />- KITCHEN WASTE (GREASE) <br />8. CONCEAL <br />PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL <br />HB <br />- HOSE BIBB <br />ROOMS <br />OR AS SPECIFICALLY NOTED. <br />GR <br />- KITCHEN WASTE (GREASE) <br />HD <br />- HUB DRAIN <br />MA <br />- MEDICAL COMPRESSED AIR <br />HW <br />- DOMESTIC HOT WATER <br />9- PROVIDE <br />ACCESS PANELS FOR ALL VALVES CONCEALED IN WAILS OR ABOVE NOW <br />HWR <br />- DOMESTIC HOT WATER RETICULATING <br />ACCESSIBLE CEILINGS. <br />MV <br />- MEDICAL VACUUM <br />IE <br />- INVERT ELEVATION <br />NI <br />-NITROGEN <br />IW <br />-INDIRECT WASTE <br />10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND <br />KW <br />KW <br />-KILOWATT <br />FLOORS WITH U/L LISTED ASSEMBLIES, FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR <br />N20 <br />- NITROUS OXIDE <br />LBSOX <br />- POUNDS <br />EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS <br />-OXYGEN <br />MA <br />- MEDICAL AIR <br />FOR FINAL FINISHES. <br />S <br />- ABOVE GROUND SANITARY <br />MV <br />MH <br />- MEDICAL VACUUM <br />-MANHOLE <br />11, FLASH AND COUNTER -FLASH ROOF PENETRATIONS. SEE ARCHITECTURAL DRAWINGS <br />-S- - - = w <br />-BELOW GROUND SANITARY <br />NI <br />- NITROGEN <br />FOR DETAILS. <br />_ <br />- - - - - - - - <br />- SANITARY VENT <br />N20 <br />- NITROUS OXIDE <br />12. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS <br />NC <br />- NORMALLY CLOSED <br />WITH ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. <br />ST <br />- ABOVE GROUND STORM <br />NIC <br />- NOT IN CONTRACT <br />- - <br />- - =ST= - - - <br />- BELOW GROUND STORM <br />NO <br />- NORMALLY OPEN <br />13. PROVIDE <br />FOUNDATION PAD PENETRATION SLEEVES, ALLOW 1" MINIMUM CLEARANCE <br />STO <br />- OVERFLOW STORM DRAIN <br />NP <br />NTS <br />- NON -POTABLE WATER <br />- NOT TO SCALE <br />BETWEEN <br />SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. <br />- - -STO- - - - <br />- BELOW GROUND OVERFLOW STORM <br />OD <br />OX <br />- OUTSIDE DIAMETER <br />-OXYGEN <br />14. SEE <br />ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />= SV=_ <br />- SOFT COLD WATER <br />PRV <br />- PRESSURE REDUCING VALVE <br />15. PROVIDE <br />AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS. <br />Mom- <br />-WATER METER <br />PSI <br />- POUNDS PER SQUARE INCH <br />PVC <br />- POLYVINYL CHLORIDE PIPE <br />16. PROVIDE <br />AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, <br />'�-- <br />— — <br />- HOSE BIBB OR WALL HYDRANT <br />RD <br />- ROOF DRAIN <br />DEVICES, <br />APPLIANCES AND APPARATUS. <br />RPBP <br />- REDUCED PRESSURE BACKFLOW PREVENTE <br />COI <br />— <br />- CLEAN OUT PLUG <br />S <br />- SANITARY <br />SF <br />- SQUARE FEET <br />17. ALL EXPOSED PIPE: AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. <br />CO (i— <br />- WALL CLEANOUT <br />SH <br />- SHEET <br />18. MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE, UNLESS OTHERWISE NOTED. <br />Coll <br />- WALL CLEANOUT <br />ST <br />- STORM <br />Co <br />� <br />- FLOOR CLEAN OUT <br />STO <br />SW <br />- OVERFLOW STORM DRAIN <br />- SOFT COLD WATER <br />19. PROVIDE <br />CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL <br />V <br />-VENT <br />CLEANOUT <br />WITH COVER FLUSH TO FINISH SURFACE. <br />FD <br />913FD OC <br />- FLOOR DRAIN <br />VC <br />-VACUUM CLEANING <br />(0")- <br />ROOF DRAIN <br />VTR <br />-VENT THRU ROOF <br />20. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET <br />WCO <br />-WALL CLEANOUT <br />FLOOR <br />DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. <br />FS M <br />- FLOOR SINK <br />WTR <br />- WATER <br />21. COORDINATE <br />PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, <br />-SHUT-OFF VALVE IN VALVE BOX <br />ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL <br />PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE RE- <br />DS ' CO DE <br />- SHUTOFF VALVE <br />ROUTED AT NO ADDITIONAL COST. <br />BALL VALVE' <br />22. ALL <br />WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER <br />-w-- <br />-CALIBRATED BALANCING VALVE <br />DESIGNED <br />TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE <br />• FLORIDA BUILDING CODE 6TH EDITION - 2017 EDITION <br />FIXTURE. <br />- CHECK VALVE (SWING) <br />NFPA #99, <br />HEALTHCARE FACILITIES CODE - 2015 <br />PRESSURE REDUCING VALVE <br />EDITION. <br />23. PROVIDE <br />SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL <br />• GUIDELINES FOR DESIGN AND CONSTRUCTION. <br />CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, <br />SOLENOID OPERATED VALVE <br />FLORIDA HEALTHCARE FACILITIES - 2014 EDITION. <br />TRAPS, <br />ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY <br />— <br />- REDUCED PRESSURE BACKFLOW PREVENTER <br />ALL LOCAL CODES - LATEST EDITION. <br />THIS CONTRACTOR OR FURNISHED BY OTHERS. <br />- RELIEF OR SAFETY VALVE <br />24. PROVIDE <br />CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A. <br />INSPECTION. <br />---- DFI — — <br />- GAS COCK <br />�,u "" <br />---- <br />- GAS PRESSURE REGULATOR.' <br />E C <br />- SHUTOFF VALVE ON RISER <br />SHEET <br />DESCRIPTION <br />ISSUED <br />r-C <br />- GAS COCK ON RISER <br />Pool <br />GENERAL PLUMBING INFORMATION <br />Yes <br />�r--- <br />- CONNECTION, TOP <br />P100 <br />DEMOLITION PLAN - PLUMBING <br />Yes <br />P101 <br />DEMOLITION PLAN - MEDICAL GAS <br />Yes <br />`r <br />- CONNECTION, BOTTOM <br />P102 <br />NEW CONSTRUCTION PLAN - GRAVITY <br />Yes <br />P103 <br />NEW CONSTRUCTION PLAN - GRAVITY ALT. <br />Yes <br />C - ELBOW, TURNED DOWN <br />- ELBOW, TURNED UP <br />P104 <br />NEW CONSTRUCTION PLAN - PRESSURE <br />Yes <br />P105 <br />NEW CONSTRUCTION PLAN - PRESSURE ALT. <br />Yes <br />- TEE, TURNED UP <br />P106 <br />NEW CONSTRUCTION PLAN - MEDICAL GAS <br />Yes <br />- TEE, TURNED DOWN <br />P107 <br />NEW CONSTRUCTION PLAN - MEDICAL GAS ALT. <br />Yes <br />P201 <br />PLUMBING DETAILS <br />Yes <br />C <br />-CAP <br />P202 <br />PLUMBING DETAILS <br />Yes <br />- DIRECTION OF FLOW <br />P301 <br />PLUMBING RISER DIAGRAMS <br />Yes <br />om AP XX - ALARM PANEL <br />MAP-XX <br />- MASTER ALARM PANEL <br />l MGO-XX <br />- MEDICAL GAS OUTLET <br />CIXIXI1tx <br />MGV-XX <br />- MEDICAL GAS VALVE BOX <br />-----.- <br />- CONNECT TO EXISTING <br />Q--a.- <br />- DEMOLISH TO POINT INDICATED <br />Q- <br />REVISION REFERENCE <br />1 <br />- DETAIL REFERENCE: TOP -DETAIL#, <br />P2.01 <br />BOTTOM -DRAWING# SHOWN ON <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT <br />PERTAIN TO THIS PROJECT <br />I Ste- -I SINK <br />SINGLE COMPARTMENT SELF RIMMING SINK CONSTRUCTED OF TYPE 30218-8 STAINLESS STEEL, 22" <br />X 19" X 7-1/2" DEEP. INTERIOR AND TOP SURFACES SHALL BE POLISHED TO A HIGH LUSTER FINISH, <br />PROVIDE SINK WITH STAINLESS STEEL CRUMB CUP STRAINER, PROVIDE FIXTURE PUNCHED FOR <br />3-HOLE FAUCET INSTALLATION ON 4-INCH CENTERS. <br />8-INCH WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK (5-3/8" <br />WIDE) SPOUT AND 2.0 GPM LAMINAR FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE <br />HANDLES WITH COLOR CODED INDEXES AND RENEWABLE SEATS IN MONEL, OUTLET OF SPOUT TO BE <br />MINIMUM OF 5- INCHES ABOVE RIM OF FIXTURE. <br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS <br />DEEP BELL FLANGE ESCUTCHEON AND 112" CHROME PLATED COPPER EXTENSION TUBE WITH SWEAT <br />CONNECTION. <br />CHROME PLATED 17 GAUGE 1-1/2 X 1-1/2 P-TRAP WITH CLEANOUT. <br />BASIS OF DESIGN <br />SINK - ELKAY 1_11-22191K-99 <br />FAUCET - CHICAGO-786-E29VP <br />SUPPLIES - MCGUIRE - H17OLK <br />TRAP - MCGUIRE - 8912 <br />F CO I CLEANOUTS <br />GENERAL(ALL FLOOR CLEANOUTS): DURO-COATED CAST IRON CLEANOUT WITH MEMBRANE FLANGE <br />WITH CADMIUM PLATED CAST IRON COUNTERSUNK PLUG. CLEANOUT CAN BE ADJUSTED TO FINISH <br />FLOOR LEVEL AFTER CONCRETE HAS SET, <br />FLOOR: HEAVY DUTY ROUND SCORIATED NICKEL BRONZE TOP <br />CARPETED FLOOR: HEAVY DUTY ROUND NICKEL BRONZE TOP RECESSED FOR CARPET. <br />TILE FLOOR: HEAVY DUTY ROUND NICKEL BRONZE TOP RECESSED FOR TILE. <br />EXTERIOR: HEAVY DUTY ROUND SCORIATED NICKEL BRONZE TOP, PROVIDE WITH 18" X 4" THICK <br />CONCRETE COLLAR, SEE DETAIL. <br />WALL: CAST IRON CLEANOUT TEE, CADMIUM PLATED CAST IRON COUNTERSUNK PLUG, SMOOTH <br />SQUARE NICKEL BRONZE WALL ACCESS COVER AND FRAME. <br />PLUG: DURA-COATED CAST IRON FERRULE AND CADMIUM PLATED CAST IRON COUNTERSUNK PLUG. <br />BASIS OF DESIGN <br />FLOOR - ZURN - ZN-1405 <br />CARPETED FLOOR - ZURN - ZN-1405-4 <br />TILE FLOOR - ZURN - ZN-1405-4 <br />EXTERIOR FLOOR - ZURN - ZN-1406 <br />WALL - ZURN-1445-4 <br />PLUG - ZURN - Z-1440 <br />SURGEONS SCRUB SINK <br />KNEE ACTIVATED DOUBLE COMPARTMENT WALL HUNG SRUB SINK. STAINLESS STEEL CONSTRUCTION <br />WITH WELDED COMPARTMENTS AND COVED CORNERS, HANDS -FREE WATER CONTROL, KNEE ACTIVATED <br />PANEL TURNS WATER ON AND OFF, STANDARD ROSE SPRAY FAUCET PRODUCING A SHOWERHEAD TYPE <br />PATTERN WITHOUT AERATING THE WATER <br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS <br />DEEP BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE WITH SWEAT <br />CONNECTION. <br />CHROME PLATED CAST BRASS GRID STRAINER & 1.1/4" O.D, TAILPIECE, CHROME PLATED 17 GAUGE <br />1-1/4" X 1-1/2" P-TRAP WITH CLEANOUT PLUG, <br />FULLY ADJUSTABLE FLOOR MOUNTED SCRUB SINK CARRIER ADJUSTED TO A HEIGHT AS <br />RECOMMENDED BY SCRUB SINK MANUFACTURER, <br />BASIS OF DESIGN <br />SURGEONS SINK - AMSCO FLEXMATIC SCRUB SINK (2-STATION) <br />STRAINER/TRAP - MCGUIRE-155A18902 <br />SUPPLY - MCGUIRE - H170LK <br />CARRIER - ZURN ZR-1224-75-1 <br />AP-11 ALARM PANEL & MASTER ALARM PANEL <br />I MP-1 I <br />THE AREA ALARM PANEL SHALL BE AN AUDIO VISUAL, MICROPROCESSOR CONTROLLED, CLOSED <br />CIRCUIT, SELF MONITORING TYPE. THE ALARM SHALL BE DESIGNED TO MONITOR THE PRESSURE IN <br />OXYGEN, NITROUS OXIDE, AIR, NITROGEN, AND VACUUM PIPING SYSTEMS. THE ALARM SHALL BE <br />DESIGNED FOR RECESSED WALL MOUNTING AND ACCOMMODATE A MAXIMUM OF SIX GAS SERVICES. <br />THE ENTIRE ASSEMBLY SHALLBE SELF CONTAINED, CONSISTING OF A ROUGH -IN BOX AND FINISHING <br />ASSEMBLY. ALL GAS AND ELECTRIC CONNECTIONS BETWEEN THE ROUGHING -IN AND FINISHING <br />ASSEMBLIES SHALL BE PLUGIN <br />THE ROUGHING -IN BOX SHALL BE FABRICATED OF ALUMINUM AND CONTAIN FACTORY ASSEMBLED <br />8-INCH LONG, 1/4-INCH NOMINAL I.D. TYPE K COPPER INLET TUBE EXTENSIONS FOR EACH GAS <br />SERVICE; A POWER SUPPLY BOARD; A 120114 V,60 HERTZ, 25 W TRANSFORMER FOR CONNECTION TO <br />THE EMERGENCY ELECTRICAL SYSTEM; AND A PROTECTIVE PLASTIC SHIELD, ALL LOW VOLTAGE <br />CIRCUITRY SHALL BE 14 V OR LESS, AND SHALL BE PREWIRED.`** ALARM PANEL TO BE MODULAR IN <br />DESIGN WITH EACH GAS/VACUUM MONITORED TO HAVE A LCD (LIQUID CRYSTAL DISPLAY) TO <br />CONTINUOUSLY INDICATE PRESSURE FROM EACH PRESSUREIVACUUM SWITCH (SENSOR) MOUNTED <br />IN LOCATIONS INDICATED ON PLANS. WIRING FOR SIGNAL BETWEEN SWITCHES AND ALARM PANEL <br />BY ELECTRICAL TRADE, COORDINATE LOCATION AS REQUIRED. <br />ALARM PANEL TO HAVE A 90 DBA AUDIBLE WARNING DEVICE, AND AN INTEGRATED CIRCUIT BOARD <br />SHALL BE INCLUDED IN THE FINISH ASSEMBLY. THE INTEGRATED CIRCUIT BOARD SHALL INCLUDE <br />THE MICROPROCESSOR; A MOMENTARY CONTACT SWITCH TO SILENCE THE AUDIBLE ALARM; A <br />MOMENTARY CONTACT SWITCH TO TEST THE UNIT FOR PROPER OPERATION OF THE AUDIBLE AND <br />VISUAL FUNCTIONS, AND THE INTEGRITY OF LOW VOLTAGE SOLID STATE CIRCUITRY; A GREEN LED, <br />LABELED NORMAL, TO INDICATE THE UNIT IS ELECTRICALLY ENERGIZED AND ALL SYSTEM <br />PRESSURES ARE NORMAL; AND A NON -CANCELABLE RED LED WARNING SIGNAL FOR EACH SYSTEM <br />SHOULD THE LINE PRESSURE VARY 20% +A FROM NORMAL, IF AN ABNORMAL LINE PRESSURE <br />CONDITION IS SENSED IN ANY SYSTEM(S) THE GREEN NORMAL SIGNAL SHALL GO OUT AND THE RED <br />WARNING SIGNAL(S) SHALL GLOW UNTIL THE SYSTEM PRESSURE RETURNS TO NORMAL. WHEN ALL <br />SYSTEM PRESSURES RETURN TO NORMAL THE GREEN NORMAL SIGNAL LED WILL AGAIN GLOW. <br />THE MICROPROCESSOR SHALL BE PROGRAMMED TO PROVIDE CONTINUOUS SELF ANALYSIS OF THE <br />INTEGRATED CIRCUIT COMPONENTS. SHOULD A FAILURE OCCUR, AN INTERMITTENT "CHIRP" <br />WARNING SIGNAL SHALL ACTIVATE. <br />THE ALARM PANEL SHALL BE EQUIPPED WITH A RELAY HAVING SELECTABLE NONC DRY CONTACTS <br />FOR EACH ABNORMAL SIGNAL TO ENABLE WARNING SIGNALS TO BE MONITORED AT REMOTE <br />LOCATIONS. CONTACTS SHALL BE RATED AT 250 MA 0 24 VOLTS AC OR DC. CONNECTIONS SHALL BE <br />MADE BY A PLUG-IN TERMINAL BLOCK TO THE CIRCUIT BOARD. <br />BASIS OF DESIGN <br />BEACON MEDAES <br />3-MODULES AREA ALARM PANEL - A2AL - E - VOA <br />5-MODULES AREA ALARM PANEL - A2AL - E - VOAN2 <br />30 FUNCTION MASTER ALARM PANEL - A2MISO - E - 30 <br />I-119-TI FLOOR SINK <br />12" X 12" X 6" DEEP, CAST IRON BODY WITH WHITE ACID RESISTING PORCELAIN ENAMEL INTERIOR, <br />ALUMINUM ANTI -SPLASH INTERIOR BOTTOM DOME STRAINER AND NICKEL BRONZE TOP. <br />BASIS OF DESIGN <br />ZURN - Z-1900-T <br />13`A�-I SHOCK ARRESTER <br />PISTON OPERATED, TYPE "K" COPPER BARREL WITH BRASS THREADED ADAPTOR. ALL JOINTS SHALL <br />BE MADE WITH 95-5 LEAD FREE SOLDER. THE PISTON SHALL BE EQUIPPED WITH TWO (2) "0" RINGS TO <br />PROVIDE A PERMANENT MECHANICAL BARRIER BETWEEN FLUID AND PRE -LOAD AIR CHARGE. <br />ARRESTORS MAY BE INSTALLED IN VERTICAL AND HORIZONTAL POSITION. <br />THE ARRESTOR SHALL BE FULLY GUARANTEED FOR ENTIRE SYSTEM LIFE. <br />NOTE: <br />SHOCK ARRESTORS SHALL BE PROVIDED AT ALL FIXTURES AND BATTERIES OF FIXTURES WHETHER <br />OR NOT THEY ARE SHOWN ON THE DRAWINGS. <br />BASIS OF DESIGN <br />PRECISION PLUMBING PRODUCTS - SC SERIES <br />11�I AUTOMATIC TRAP PRIMER VALVE <br />MACHINED OF CORROSION RESISTANT BRASS SHALL NOT CONTAIN SPRINGS OR DIAPHRAMS, "0" <br />RING SEALS TESTED FOR RELIABILITY BETWEEN 40 TO 4500 F. INLET OPENING SHALL BE 112-INCH <br />MALE NPT, OUTLET SHALL BE 1/2-INCH FEMALE NPT. <br />TRAP PRIMER OPERATES VIA LINE PRESSURE DROP AND DOES NOT NEED TO BE PLACED NEAR A <br />FIXTURE. <br />BASIS OF DESIGN <br />PRECISION PLUMBING PRODUCTS <br />I140V-11 MEDICAL_ GAS VALVE BOX <br />THE VALVE BOX SHALL BE CONSTRUCTED OF EXTRUDED ALUMINUM WITH A 112" PLASTER FLANGE ON <br />ALL FOUR SIDES. A TEMPORARY PLASTER GUARD SHALL PREVENT DEBRIS FROM ENTERING THE BOX <br />DURING INSTALLATION. A LABEL HOLDER AND LABEL FOR IDENTIFYING THE GAS AND AREA THE <br />VALVE CONTROLS SHALL BE PROVIDED FOR THE CONTRACTOR TO INSTALL. <br />THE FINISH FRAME SHALL BE CONSTRUCTED OF EXTRUDED, ETCHED, AND ANODIZED ALUMINUM. <br />CONCEALED MOUNTING SCREWS SHALL SECURE THE FINISH FRAME TO THE VALVE BOX. THE TINTED, <br />TRANSPARENT WINDOW SHALL BE EASILY REMOVED OR REPLACED WITHOUT THE AIDS OF TOOLS. <br />THE BALL TYPE VALVE SHALL HAVE A CAST BRONZE BODY WITH A BRASS OR BRONZE BALL. THE <br />BOLTED UNION SHALL ALLOW THE VALVE TO SWING OUT FOR EASY SERVICE OR INSTALLATION. THE <br />VALVE IS DESIGNED FOR A WORKING PRESSURE OF 400 P.S.L. THE VINYL -COATED HANDLE SHALL <br />ONLY REQUIRE ONE QUARTER OF A TURN TO COMPLETELY OPEN OR CLOSE THE VALVE. THE VALVE <br />WITH TUBING EXTENSIONS SHALL BE FACTORY BRAZED, PRESSURE TESTED, CLEANED FOR OXYGEN <br />SERVICE AND CAPPED. A LABEL SHALL BE AFFIXED TO EACH VALVE AND BOTH TUBE EXTENSIONS <br />IDENTIFYING THE GAS BY NAME AND COLOR. A 1-1/2-INCH DIAMETER LINE PRESSURE MONITORING <br />GAUGE SHALL BE SUPPLIED FOR INSTALLATION DOWNSTREAM OF THE SHUT-OFF VALVE. <br />PRESSURENACUUM GAUGE(S) TO BE PROVIDED FOR EACH GAS: 0, A, & N20 (0-100 PSIG FOR 0, A & <br />N20), N (0-300 PSIG FOR N) AND VAC (0-30 INCHES HG) <br />SEE PLAN FOR VALVE SIZES REQUIRED. <br />BASIS OF DESIGN <br />BEACON MEDAES SERIES <br />IMGO-11 MEDICAL_ GAS WALL OUTLET <br />THE QUICK CONNECT RECESSED OUTLETS SHALL BE SUITABLE FOR THE SERVICES LISTED BELOW. <br />OUTLETS SHALL CONSIST OF A ROUGHING IN ASSEMBLY AND A FINISHED ASSEMBLY. <br />THE ROUGHING IN ASSEMBLY SHALL CONSIST OF A DIE-CAST BACK PLATE WITH MOUNTING FLANGES <br />ON ALL FOUR SIDES, A RAISED PLASTER STRIKE, AND A NON - REMOVABLE POSITIVE PIN -KEYING <br />ARRANGEMENT FOR EACH SPECIFIC GAS SERVICE. IDENTIFICATION OF EACH GAS SERVICE SHALL BE <br />PERMANENTLY CAST INTO THE BACK PLATE AND CAN BE READ THROUGH A TRANSPARENT PLASTIC <br />PLASTER GUARD. <br />MOUNTED TO THE BACK PLATE IS A FULLY ASSEMBLED BRASS SECONDARY CHECK THAT IS <br />COMPLETELY SERVICEABLE FROM THE FRONT. THE CHECK PREVENTS A GAS FLOW WHEN THE <br />FINISHING ASSEMBLY IS REMOVED FOR MAINTENANCE OR SERVICE. THE SECONDARY CHECK VALVE <br />INCLUDES TINCHES OF 3/8-INCH O.D. TYPE K COPPER INLET TUBE WITH A LABEL IDENTIFYING THE <br />SPECIFIC GAS BY NAME AND COLOR AND A PLASTIC DUST CAP. ROTATION OF THE INLET TUBE SHALL <br />ALLOW GAS CONNECTION FROM THE TOP OR BOTTOM. <br />THE FINISH ASSEMBLY SHALL CONSIST OF A STAINLESS STEEL FINISH PLATE, A DIE-CAST CHROME <br />PLATED COVER PLATE, A MACHINED BRASS HOUSING FOR THE PRIMARY CHECK VALVE, THE <br />SECONDARY CHECK VALVE, AND POSITIVE PIN -KEYING DEVICES TO PREVENT ACCIDENTAL <br />INSTALLATION INTO A ROUGHING -IN ASSEMBLY OF A DISSIMILAR GAS. THE FINISHING ASSEMBLY <br />SHALL INCORPORATE A DOUBLE SEAL WHICH AUTOMATICALLY ENGAGES WHEN A HOSE ADAPTER OR <br />PATIENT TREATMENT DEVICE IS REMOVED FROM THE OUTLET, <br />THE FINISHING ASSEMBLY SHALL BE DESIGNED IN ACCORDANCE WITH CGA V-5 STANDARD FOR <br />DIAMETER INDEX SAFETY SYSTEM. THE EXPOSED PORTION OF QUICK CONNECT OUTLET <br />CONNECTION SHALL BE POLISHED CHROME PLATE. <br />GAS SERVICE COMPLETE ASSEMBLY <br />BASIS OF DESIGN <br />BEACON MEDAES (CHEMETRON COMPATIBLE) <br />OXYGEN - O-CHWAL-U-OXY - 0-CHWAL-U-AIR <br />VACUUM - 0-CHWAL-U-VAC <br />VACUUM SLIDE - O-WALSLIDE <br />NITROUS OXIDE - 0-CHWAL-U-N20 <br />NITROGEN - O-DISWAL-E-NIT <br />301 E. Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893-5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26MO956 <br />5620 * LCC000210 * GB238 <br />ENGINEERING <br />TLC <br />S O L U T I O N <br />®Copyright 2019 <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />COA 15 <br />P 407.841.9050 <br />wwy.Oc-engineers.com <br />TLC No.:119469 <br />THINK. LISTEN. <br />CREATE. <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS BUILT OUT <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />``��►�r�rrrrrii <br />.0� LEE ,10& ! . <br />. th • '" G•E•N S �d <br />No 71576 <br />:1 STATE OF 4U <br />dLU <br />�iFs•COR�p. �; <br />o <br />,ON <br />W <br />J <br />t� <br />v <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 12/1112019 <br />REVIEWED BY: ALJ <br />DRAWN BY, BJL <br />DESIGNED BY: BJL <br />PROJECT NUMBER: <br />504-0253-000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />GENERAL PLUMBING <br />INFORMATION <br />SHEET ID: <br />BLDG. ID <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright @ 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />3" SCALE 0 3" 6" 1' <br />1 1/2" SCALE 0 6" 1' 2' <br />3/8" SCALE 3' 0 18" 3' 6' <br />1 /4" SCALE 4' 0 2' 4' 8' <br />1/8" SCALE 8' 0 4' 8' 16' <br />