Laserfiche WebLink
7 <br />C <br />M. <br />F <br />1" 4 <br />1" I <br />1 <br />1" 90" ELL <br />1" NIP <br />1.90. <br />BRANCH LINE <br />1x1Q REDUCER <br />1" DR <br />CEILING <br />IF SYSTEM PRESSURE EXCEEDS 100 PSI PROVIDE HANGERS PER NFPA 13 <br />9.2.3.4. AND 9.2.3.5.2 THAT PREVENTS UPWARD MOVEMENT OF THE PIPE <br />FOR SPRINKLERS IN THE PENDENT POSITION. A MAXIMUM OF 12" FROM <br />THE END SPRINKLER ON A BRANCH LINE AND ALL ARM-OVERS OVER 12". <br />RETURN BEND / SWING JOINT <br />No Scale <br />TOP BEAM CLAMP <br />(UL LISTED OR FM APPROVED) <br />"ASTENER <br />OR F,M, APPROVED) <br />ALL THREAD ROD <br />PIPE HANGER RING <br />(U.L. LISTED OR F.M. APPROVED) <br />IF SYSTEM PRESSURE EXCEEDS 100 PSI PROVIDE HANGERS PER NFPA 13 <br />9.2.3.4. AND 9.2.3.5.2 THAT PREVENTS UPWARD MOVEMENT OF THE PIPE <br />FOR SPRINKLERS IN THE PENDENT POSITION. A MAXIMUM OF 12" FROM <br />THE END SPRINKLER ON A BRANCH LINE AND ALL ARM-OVERS OVER 12". <br />HANGER - CONCRETE / STEEL <br />No Scale <br />2 <br />BRANCH LINE <br />1" 90" ELL <br />REDUCER <br />CEILING <br />N <br />3 <br />NEW CONSTUCTION PLAN - FIRE PROTECTION <br />SCALE: 1/4" =1'-0" <br />4 <br />Q FIRE PROTECTION KEYNOTES <br />1 EXISTING STANDPIPE WITH 2-1/2" FDV. <br />2 EXISTING SPRINKLER CONTROL VALVE WITH TAMPER AND FLOW SWITCH. <br />3 EXISTING CONTROL VALVE WITH TAMPER SWITCH. <br />4 REMOVE EXISTING SPRINKLER AND ARM -OVER TO NEW SPRINKLER(S) LOCATION. <br />5 REMOVE EXISTING SPRINKLER AND PLUG OUTLET. <br />6 EXISTING SPRINKLER TO REMAIN IN THIS AREA. <br />5 <br />FIRE PROTECTION NOTE: <br />THE EXISTING FIRE PROTECTION SYSTEM SHALL BE MODIFIED TO <br />ACCOMMODATE THE NEW CEILING AND WALL CONFIGURATIONS. <br />COORDINATE THE EXISTING SPRINKLER SYSTEM WITH THE NEW CEILING <br />HEIGHTS AND THE NEW MECHANICAL EQUIPMENT. <br />KEY PLAN - LEVEL 2 & T <br />SCALE: N.T.S. TRUE PROJECT <br />NORTH NORTH <br />301 E. Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893.5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cent. Nos. AAC001886 * IB26000958 <br />5620 * LCC000210 * GB238 <br />L <br />ENGINEERING <br />A 1 <br />SOLUTION <br />04ydght 2019 <br />255 S. Orange Avenue <br />Suite 1600 <br />COA 15 <br />Orlando, FL 32801 <br />,tic-anginears.com <br />P 407.841.9050 <br />TLC No.:119469 <br />THINK. LISTEN. <br />CREATE. <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS BUILT OUT <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />% LEE +Jpy <br />No 71576 <br />� r <br />r + <br />' STATE OF ' UJ ` <br />I!r'p''C Ft ;J P'LU <br />z <br />UJI <br />c� <br />d <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 12/11/2019 <br />REVIEWED BY: AU <br />DRAWN BY: JLL <br />DESIGNED BY: JLL <br />PROJECT NUMBER: <br />50"253-000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />NEW CONSTRUCTION <br />PLAN - FIRE <br />PROTECTION <br />SHEET ID: <br />BLDG. ID <br />FP1 03 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright 0 2019. This drawing is an instrument of service and properly of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />3" SCALE 0 3" 6" 1" <br />1 1/2" SCALE D 6" 1' 2' <br />3/8" SCALE 3' 0 18" 3' 6' <br />1/4" SCALE 4' 0 2' 4' 8' <br />1/8" SCALE 8' 0 4' 8' 16, <br />