Laserfiche WebLink
`1 <br />0 <br />0 <br />.r. <br />a� <br />00 <br />4 -- <br />CD <br />4 <br />. q1 <br />sa <br />L <br />a� <br />a <br />E <br />Q) <br />9� <br />2 <br />a- <br />C7 <br />n <br />x0 <br />z <br />J <br />x <br />z <br />J <br />z <br />z... <br />2 <br />N <br />m <br />I <br />0 <br /><C <br />i <br />m <br />0 <br />CL <br />m <br />U) <br />a� <br />N <br />LL <br />I <br />N <br />0 <br />-4r <br />0 <br />-r <br />0 <br />J <br />PLUMBING FIXTURE SCHEDULE <br />WC-1 FLOOR MOUNTED ACCESSIBLE WATER CLOSET W/BEDPAN WASHER <br />VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED, SIPHON JET, ELONGATED CLOSET BOWL WITH INTEGRAL <br />BEDPAN LUGS, 1-1/2 INCH TOP SPUD. <br />1.6 GALLON, CHROME PLATED FLUSH VALVE(EXPOSED), METAL OSCILLATING NON -HOLD OPEN HANDLE, <br />1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM <br />BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1/2" TOP SPUD, WALL AND SPUD FLANGES, <br />SOLID RING PIPE SUPPORT, BEDPAN WASHER DIVERTER ASSEMBLY WITH WALL SUPPORT, PROVIDE <br />OFFSET TO AVOID GRAB BAR, MOUNT FLUSH VALVE HANDLE MAX 44" A.F.F.. <br />CONTOURED SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH OPEN FRONT LESS COVER. SEAT SHALL <br />INCLUDE STAINLESS STEEL SELF SUSTAINING CHECK HINGE FEATURE. <br />BASIS OF DESIGN <br />CHINA - AMERICAN STANDARD - 3043.156 <br />FLUSH VALVE - SLOAN ROYAL SLIMLINE BPW-1150-1.6 <br />SEAT - BEMIS - 1655--SS/C <br />INTEGRAL COUNTER LAVATORY <br />LAVATORY BOWL PROVIDED AS INTEGRAL PART OF COUNTERTOP BY ARCHITECTURAL, COORDINATE DRAIN <br />CONNECTION AND FAUCET HOLE FOR THREE HOLE INSTALLATION. <br />8 WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK SPOUT AND MAX. <br />2 GPM FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE HANDLES WITH COLOR CODED INDEXES <br />AND RENEWABLE SEATS IN MONEL. OUTLET OF SPOUT TO BE MINIMUM OF 5 INCHES ABOVE RIM OF <br />FIXTURE. <br />CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1 /4" O.D. TAILPIECE, CHROME PLATED 17 GAUGE <br />1-1 /4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND TAILPIECE <br />WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE COLLARS TO ALLOW <br />PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE STOP AND <br />WATER SUPPLY COVERS OF SAME MATERIAL. <br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP <br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE. <br />BOWL - INTEGRAL WITH COUNTERTOP <br />FAUCET - CHICAGO - 785-E29VP <br />FAUCET - CHICAGO - 582-4-E29VP <br />STRAINER/TRAP - MCGUIRE - 155A/PW 2150 <br />SUPPLIES - MCGUIRE - H170LK <br />1 INTEGRAL COUNTER SINK <br />SINK BOWL PROVIDED AS INTEGRAL PART OF COUNTERTOP BY ARCHITECTURAL, COORDINATE DRAIN <br />CONNECTION AND FAUCET HOLE FOR THREE HOLE INSTALLATION. <br />8" WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK SPOUT AND MAX. <br />2 GPM FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE HANDLES WITH COLOR CODED <br />INDEXES AND RENEWABLE SEATS IN MONEL. OUTLET OF SPOUT TO BE MINIMUM OF 5 INCHES ABOVE RIM <br />OF FIXTURE. <br />CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1/4" O.D. TAILPIECE, CHROME PLATED 17 GAUGE <br />1-1/4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND TAILPIECE <br />WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE COLLARS TO <br />ALLOW PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE <br />STOP AND WATER SUPPLY COVERS OF SAME MATERIAL. <br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP <br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE. <br />BASIS OF DESIGN <br />BOWL - INTEGRAL WITH COUNTERTOP <br />FAUCET - CHICAGO - 785-E29VP <br />FAUCET - CHICAGO - 582-4-E29VP <br />STRAINER/TRAP - MCGUIRE - 155A/PW 2150 <br />SUPPLIES - MCGUIRE - H170LK <br />1.00 - GENERAL PROVISIONS <br />S 1 ACCESSIBLE SHOWER VALVE W/DIVERTER AND DRAIN <br />ANTI -SCALD BALANCED PRESSURE CONCEALED SHOWER VALVE WITH STAINLESS STEEL BALANCING PISTON, <br />VOLUME CONTROL, INTEGRAL SERVICE STOPS, INTEGRAL BI-METAL THERMOMETER WITH STAINLESS STEEL <br />COMPONENTS MOUNTED IN SHATTERPROOF CASE AND ALL METAL CHROME PLATED TRIM. <br />HAND SPRAY UNIT ON 30" WALL MOUNTED ADJUSTING BAR, FLEXIBLE METAL HOSE WITH WALL <br />CONNECTION AND INTEGRAL IN -LINE VACUUM BREAKER. SHOWER HEAD WITH MAX. 2.5 GPM FLOW <br />REGULATOR CHROME PLATED BRASS DIVERTER AND FIXED ADJUSTABLE SHOWER HEAD WITH FLANGE AND <br />ARM, ALL TRIM SHALL BE COPPER NICKEL CHROME PLATED. <br />COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLE MEMBRANE CLAMP AND <br />ADJUSTABLE COLLAR WITH 6" ROUND TOP, NICKEL BRONZE STRAINER. <br />BASIS OF DESIGN <br />VALVE AND SHOWER HEAD SYSTEM - SYMMONS - 1-117VT-FS-B30 <br />SHOWER STALL DRAIN - ZURN Z-415 <br />5H-2 ACCESSIBLE SHOWER VALVE W/DIVERTER <br />ANTI -SCALD BALANCED PRESSURE CONCEALED SHOWER VALVE WITH STAINLESS STEEL BALANCING PISTON, <br />VOLUME CONTROL, INTEGRAL SERVICE STOPS, INTEGRAL BI-METAL THERMOMETER WITH STAINLESS STEEL <br />COMPONENTS MOUNTED IN SHATTERPROOF CASE AND ALL METAL CHROME PLATED TRIM. <br />HAND SPRAY UNIT ON 30" WALL MOUNTED ADJUSTING BAR, FLEXIBLE METAL HOSE WITH WALL <br />CONNECTION AND INTEGRAL IN -LINE VACUUM BREAKER. SHOWER HEAD WITH MAX. 2.5 GPM FLOW <br />REGULATOR CHROME PLATED BRASS DIVERTER AND FIXED ADJUSTABLE SHOWER HEAD WITH FLANGE AND <br />ARM, ALL TRIM SHALL BE COPPER NICKEL CHROME PLATED. <br />BASIS OF DESIGN <br />VALVE AND SHOWER HEAD SYSTEM - SYMMONS - 1-117VT-FS-830 <br />GO MEDICAL GAS WALL OUTLET <br />THE QUICK CONNECT RECESSED OUTLETS SHALL BE SUITABLE FOR THE SERVICES LISTED BELOW. OUTLETS <br />SHALL CONSIST OF A ROUGHING IN ASSEMBLY AND A FINISHED ASSEMBLY. <br />THE ROUGHING IN ASSEMBLY SHALL CONSIST OF A DIE-CAST BACK PLATE WITH MOUNTING FLANGES ON <br />ALL FOUR SIDES, A RAISED PLASTER STRIKE, AND A NON - REMOVABLE POSITIVE PIN -KEYING <br />ARRANGEMENT FOR EACH SPECIFIC GAS SERVICE. IDENTIFICATION OF EACH GAS SERVICE SHALL BE <br />PERMANENTLY CAST INTO THE BACK PLATE AND CAN BE READ THROUGH A TRANSPARENT PLASTIC <br />PLASTER GUARD. <br />MOUNTED TO THE BACK PLATE IS A FULLY ASSEMBLED BRASS SECONDARY CHECK THAT IS COMPLETELY <br />SERVICEABLE FROM THE FRONT. THE CHECK PREVENTS A GAS FLOW WHEN THE FINISHING ASSEMBLY IS <br />REMOVED FOR MAINTENANCE OR SERVICE. THE SECONDARY CHECK VALVE INCLUDES 7-INCHES OF <br />3/8-INCH O.D. TYPE K COPPER INLET TUBE WITH A LABEL IDENTIFYING THE SPECIFIC GAS BY NAME AND <br />COLOR AND A PLASTIC DUST CAP. ROTATION OF THE INLET TUBE SHALL ALLOW GAS CONNECTION FROM <br />THE TOP. <br />THE FINISH ASSEMBLY SHALL CONSIST OF A STAINLESS STEEL FINISH PLATE, A DIE-CAST CHROME PLATED <br />COVER PLATE, A MACHINED BRASS HOUSING FOR THE PRIMARY CHECK VALVE, THE SECONDARY CHECK <br />VALVE, AND POSITIVE PIN -KEYING DEVICES TO PREVENT ACCIDENTAL INSTALLATION INTO A ROUGHING -IN <br />ASSEMBLY OF A DISSIMILAR GAS. THE FINISHING ASSEMBLY SHALL INCORPORATE A DOUBLE SEAL WHICH <br />AUTOMATICALLY ENGAGES WHEN A HOSE ADAPTER OR PATIENT TREATMENT DEVICE IS REMOVED FROM THE <br />OUTLET. <br />THE FINISHING ASSEMBLY SHALL BE DESIGNED IN ACCORDANCE WITH CGA V-5 STANDARD FOR DIAMETER <br />INDEX SAFETY SYSTEM, THE EXPOSED PORTION OF QUICK CONNECT OUTLET CONNECTION SHALL BE <br />POLISHED CHROME PLATE. <br />GAS SERVICE COMPLETE ASSEMBLY <br />BASIS OF DESIGN <br />AMICO (CHEMETRON COMPATIBLE) <br />OXYGEN - O-CHWAL-U-OXY - O-CHWAL-U-AIR <br />VACUUM - 0-CHWAL-U-VAC <br />VACUUM SLIDE - O-WALSLIDE <br />NITROUS OXIDE - O-CHWAL-U-N20 <br />NITROGEN - O-DISWAL-E-NIT <br />PLUMBING SPECIFICATIONS <br />1.1 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING <br />PLUMBING SYSTEM. <br />1.2 CODES AND STANDARDS: ALL PLUMBING WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2010 <br />FLORIDA BUILDING CODE, PLUMBING AND ALL LOCAL CODES HAVING JURISDICTION. <br />1.3 ALL PLUMBING WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. <br />1.4 CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED FOR THE <br />EXECUTION OF THIS WORK. <br />1.5 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE FABRICATION OR <br />INSTALLATION. OFFSETS AND/OR TRANSITIONS REQUIRED SHALL BE PROVIDED WITHOUT <br />ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL HIS WORK IN A TIMELY MANNER <br />TO PREVENT DELAYS IN THE CONSTRUCTION. <br />1.6 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT AND/OR <br />MATERIAL. <br />1.7 PROVIDE ALL MATERIALS REQUIRED TO PROPERLY SUPPORT ALL PIPING AND EQUIPMENT. PIPE <br />HANGERS SHALL BE ADJUSTABLE TYPE AND BE SPACED IN ACCORDANCE WITH THE 2010 FLORIDA <br />BUILDING CODE, PLUMBING PROVIDED PLASTIC COATED RING ON HANGERS FOR COPPER PIPING <br />TO PROVIDE DIELECTRIC ISOLATION. <br />1.8 PROVIDE DIELECTRIC UNIONS OR FLANGES BETWEEN COPPER AND STEEL PIPING AND BETWEEN <br />BRASSWARE AND STEEL. DO NOT USE STEEL AND COPPER PIPING IN THE SAME SYSTEM WITHOUT <br />SUCH ISOLATION. <br />1.9 PROVIDE REDUCING FITTINGS (REDUCING BUSHINGS SHALL NOT BE USED) WHERE CHANGES IN <br />PIPE SIZES OCCUR. <br />1.10 THIS CONTRACTOR SHALL SUPPLY AND INSTALL ALL SERVICES THROUGHOUT THE BUILDING AND <br />MAKE CONNECTION TO SITE UTILITIES APPROXIMATELY 5' On OUTSIDE THE BUILDING. <br />CONTRACTOR SHALL SUPPLY AND INSTALL FIXTURES, FITTINGS, VALVING AND TRIM AND MAKE <br />READY FOR USE ALL FIXTURES, EQUIPMENT, ETC. <br />1.11 SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />2.00 - BASIC MATERIALS AND METHODS <br />2.1 ABOVEGROUND WATER PIPE AND FITTINGS - TYPE "L" COPPER, HARD DRAWN. <br />2.2 PROVIDE UNIONS OR FLANGES IN ALL DOMESTIC WATER SERVICE LINES AT EACH PIECE OF <br />EQUIPMENT, SPECIALTY VALVES OR AT OTHER LOCATIONS REQUIRED FOR READY DISCONNECT. <br />2.3 WATER HAMMER ARRESTORS SHALL BE INSTALLED AT THE LOCATIONS ON THE PLANS AND IN <br />ACCORDANCE WITH PDI STANDARD WH-201. PRODUCTS SHALL BE EQUAL TO THOSE <br />MANUFACTURED BY PRECISION PLUMBING PRODUCTS OR SIOUX CHIEF. <br />2.4 VALVES: PROVIDE VALVES TO ISOLATE EACH RISER, BRANCH LINE AND PIECE OF EQUIPMENT. <br />2.5 PROVIDE PRESSURE REDUCING VALVE AND AIR GAP CONNECTION AT DISHWASHER AS REQUIRED <br />BY CODE AND ACCORDING TO MANUFACTURER. <br />2.6 ABOVEGROUND SANITARY WASTE, SANITARY VENT AND STORM PIPING - SERVICE WEIGHT CAST IRON <br />WITH NO -HUB COUPLINGS - ("HUSKEY 4000" OR "CLAMPALL" ONLY). <br />2.7 ABOVEGROUND SANITARY WASTE ARMS - SERVICE WEIGHT CAST IRON WITH NO -HUB COUPLINGS OR <br />DWV COPPER. <br />2.8 INSTALL GRAVITY LINES SLOPED AT 1/8" PER FOOT FOR PIPE 3" AND LARGER AND 1/4" PER <br />FOOT FOR PIPE SMALLER THAT 3". VERIFY INVERT ELEVATION WITH SITE PIPING PRIOR TO ANY PIPE BEING <br />INSTALLED. <br />3.00 - PLUMBING FIXTURES AND TRIM <br />3.1 ALL PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH IN COMMERCIAL <br />STANDARD CS77-28 AS PROMULGATED BY THE U.S. DEPARTMENT OF COMMERCE. <br />3.2 ALL FIXTURES ARE TO BE WHITE VITREOUS CHINA UNLESS OTHERWISE SPECIFICALLY NOTED. <br />3.3 FIXTURES AND FITTINGS PROPOSED SHALL BE FROM ONE MANUFACTURER AND OF SIMILAR <br />CHARACTER IN ANY ROOM OR LOCATION. ESCUTCHEONS, HANDLES, ETC., ON THE DIFFERENT FIXTURES <br />SHALL BE OF THE SAME DESIGN, <br />3.4 PROVIDE FIXTURE CARRIERS AS RECOMMENDED BY FIXTURE MANUFACTURER AND/OR <br />CONSTRUCTION METHOD. <br />3.5 PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON -ACCESSIBLE CEILINGS. <br />REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. <br />3.6 FLOOR DRAIN TRAP SEALS SHALL HAVE AN APPROVED AUTOMATIC PRIMING DEVICE DESIGNED FOR <br />THAT PURPOSE. <br />3.7 ALL CONCEALED TRAPS, PRIMERS, VALVES, CLEANOUTS, ETC. LOCATED IN TILED AREAS SHALL BE <br />PROVIDED WITH AN ACCESS PANEL. <br />4.00 - INSULATION <br />4.1 ABOVE GROUND HOT WATER - FIBERGLASS, 1" THICKNESS, ASJ JACKET, DOUBLE SEALING LAP <br />JOINT, 0.24 K AT 75"F. INSULATION AND ADHESIVES INSTALLED IN RETURN AIR PLENUMS SHALL HAVE A <br />MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50. <br />5.00 - VALVES AND COCKS <br />5.1 VALVES 2" AND SMALLER SHALL BE BALL VALVES, 150 PSI SWP, 400 PSI WOG. STANDARD <br />PORT BALL, BRONZE TRIM, CAST BRONZE BODY, CHROMIUM -PLATED BRASS BALL, BRONZE NON -BLOWOUT <br />STEM, TEFLON SEAT, DOUBLE O-RING STEM SEALS, ZINC -COATED STEEL HANDLE WITH PLASTIC COATED HAND <br />GRIP, 90 DEGREE OPERATION FROM FULL OPEN TO TIGHT SHUT-OFF - STOCKHAM S214-BR-T T, STOCKHAM <br />S216-BR-T-S OR EQUAL. <br />5.2 CHECK VALVES, ROUGH BRASS, REGRINDING BRONZE DISC - STOCKHAM B-345; B-309 OR EQUAL. <br />6.00 - STERILIZATION <br />6.1 DOMESTIC WATER PIPING SHALL BE THOROUGHLY FLUSHED OUT AND STERILIZED IN ACCORDANCE <br />WITH THE 2010 FLORIDA BUILDING CODE, PLUMBING. <br />PLUMBING SYMBOL LEGEND <br />_-��- SYMBOL --_ DESCRIPTION <br />AV ACID VENT <br />AW - ACID WASTE <br />----AW---- - BELOW GROUND ACID WASTE <br />CD - ABOVE GROUND CONDENSATE DRAIN <br />----- CD---- - BELOW GROUND CONDENSATE DRAIN <br />CA - COMPRESSED AIR <br />- DOMESTIC COLD WATER <br />G <br />GR <br />ST <br />---- ST ----- <br />STO <br />---- STO --- <br />M <br />C01 <br />COI <br />co <br />FD 1113FD SC <br />- <br />(0) <br />FS W <br />ppG <br />mc- <br />wTw <br />rC <br />11, <br />C <br />= AP-XX <br />1Q-XX <br />11'1 r <br />-,1 '11 MGV-XX <br />zi <br />- DOMESTIC HOT WATER <br />- DOMESTIC HOT WATER RECIRCULATING <br />- GAS <br />- KITCHEN WASTE (GREASE) <br />- ABOVE GROUND SANITARY <br />- BELOW GROUND SANITARY <br />- SANITARY VENT <br />- EXISTING PIPING TO BE REMOVED <br />- ABOVE GROUND STORM <br />- BELOW GROUND STORM <br />- OVERFLOW STORM DRAIN <br />- BELOW GROUND OVERFLOW STORM <br />- WATER METER <br />- HOSE BIBB OR WALL HYDRANT <br />- CLEAN OUT PLUG <br />- WALL CLEANOUT <br />- FLOOR CLEAN OUT <br />- FLOOR DRAIN <br />- ROOF DRAIN <br />- FLOOR SINK <br />- SHUT-OFF VALVE IN VALVE BOX <br />- SHUTOFF VALVE <br />- BALL VALVE <br />- CALIBRATED BALANCING VALVE <br />- CHECK VALVE (SWING) <br />- PRESSURE REDUCING VALVE <br />- SOLENOID OPERATED VALVE <br />- REDUCED PRESSURE BACKFLOW PREVENTER <br />- RELIEF OR SAFETY VALVE <br />- GAS COCK <br />GAS PRESSURE REGULATOR <br />- SHUTOFF VALVE ON RISER <br />- GAS COCK ON RISER <br />- CONNECTION, TOP <br />- CONNECTION, BOTTOM <br />- ELBOW, TURNED DOWN <br />- ELBOW, TURNED UP <br />- TEE, TURNED UP <br />- TEE, TURNED DOWN <br />- CAP <br />- DIRECTION OF FLOW <br />- ALARM PANEL <br />- MEDICAL GAS OUTLET <br />- MEDICAL GAS VALVE BOX <br />- CONNECT TO EXISTING <br />- DEMOLISH TO POINT INDICATED <br />- REVISION REFERENCE <br />- DETAIL REFERENCE: TOP -DETAIL#, <br />BOTTOM -DRAWING# SHOWN ON <br />PLUMBING ABBREVIATIONS <br />SYMBOL <br />DESCRIPTION <br />AFF <br />- ABOVE FINISH FLOOR <br />AW <br />- ACID WASTE <br />AV <br />- ACID VENT <br />CA <br />- COMPRESSED AIR <br />CD <br />- CONDENSATE DRAIN <br />CFH <br />- CUBIC FEET PER HOUR <br />CO <br />- CLEANOUT <br />CONT <br />- CONTINUATION <br />DCW <br />- DOMESTIC COLD WATER <br />DHW <br />- DOMESTIC HOT WATER SUPPLY <br />DHR <br />- DOMESTIC HOT WATER RECIRCULATING <br />DN <br />- DOWN <br />DS <br />- DOWNSPOUT <br />DWG <br />- DRAWING <br />EXIST <br />- EXISTING <br />'F <br />- DEGREE FAHRENHEIT <br />FCO <br />- FLOOR CLEANOUT <br />FD <br />- FLOOR DRAIN <br />FS <br />- FLOOR SINK <br />G <br />- GAS <br />GPH <br />- GALLONS PER HOUR <br />GPM <br />- GALLONS PER MINUTE <br />GR <br />- KITCHEN WASTE (GREASE) <br />HB <br />- HOSE BIBB <br />HD <br />- HUB DRAIN <br />IE <br />- INVERT ELEVATION <br />IW <br />- INDIRECT WASTE <br />KW <br />- KILOWATT <br />LBS <br />- POUNDS <br />MH <br />- MANHOLE <br />NC <br />- NORMALLY CLOSED <br />NIC <br />- NOT IN CONTRACT <br />NO <br />- NORMALLY OPEN <br />NTS <br />- NOT TO SCALE <br />OD <br />- OUTSIDE DIAMETER <br />PRV <br />- PRESSURE REDUCING VALVE <br />PSI <br />- POUNDS PER SQUARE INCH <br />PVC <br />- POLYVINYL CHLORIDE PIPE <br />RD <br />- ROOF DRAIN <br />RPBP <br />- REDUCED PRESSURE BACKFLOW PREVENTOR <br />SAN <br />- SANITARY <br />SD <br />- STORM DRAIN <br />SF <br />- SQUARE FEET <br />SH <br />- SHEET <br />ST <br />- STORM <br />STO <br />- OVERFLOW STORM DRAIN <br />V <br />- VENT <br />VAC <br />- VACUUM <br />VTR <br />- VENT THRU ROOF <br />WCO <br />- WALL CLEANOUT <br />WTR <br />- WATER <br />PLUMBING REPORTS/ <br />CERTIFICATIONS <br />SYSTEM CHECKS TO BE COMPLETED PRIOR AND _DURING AHCA SURVEY <br />MEDICAL GAS SYSTEMS TEST FOR THE RENOVATED ZONES. <br />REQUIRED REPORTS AND CERTIFICATIONS <br />- MEDICAL GAS CERTIFICATION FOR THE RENOVATED ZONES. <br />- WATER PURIFICATION CERTIFICATE FOR THE RENOVATED AREA. <br />ii A <br />FLORIDA BUILDING CODE 2010 EDITION <br />FLORIDA FIRE PREVENTION CODE 2010 EDITION <br />FLORIDA ADMINISTRATION CODE 61G15 FAC <br />NFPA 13, 2007 EDITION <br />NFPA 14, 2007 EDITION <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT <br />INSULATED PIPE HANGER <br />No Scab <br />PIPE HANGER <br />(SEE SPECS.) <br />SHEETMETAL <br />_E W/FLARED 1 <br />GENERAL NOTES <br />1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS. <br />2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. <br />3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW <br />SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS <br />PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON <br />DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS <br />DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY. <br />4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, <br />WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF <br />THE NEW WORK, <br />5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. <br />SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. <br />SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING <br />HOURS. <br />6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS <br />NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY <br />ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN <br />CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS AND OTHER <br />POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES. <br />7. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL <br />ROOMS OR AS SPECIFICALLY NOTED. <br />8. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE <br />NON -ACCESSIBLE CEILINGS. <br />9. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND <br />FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR <br />EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS <br />FOR FINAL FINISHES. <br />10. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH <br />ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. <br />11. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE <br />BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. <br />12. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />13, PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS. <br />14. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, <br />DEVICES, APPLIANCES AND APPARATUS. <br />15. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. <br />16. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL <br />CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. <br />17. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET <br />FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. <br />18. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) <br />PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL <br />PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE <br />RE-ROUTED AT NO ADDITIONAL COST. <br />19. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER <br />DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE <br />FIXTURE. <br />20. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL <br />CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, <br />ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS <br />CONTRACTOR OR FURNISHED BY OTHERS. <br />24. PROVIDE CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A. INSPECTION. <br />PLUMBING DRAWING INDEX <br />SHEET <br />DESCRIPTION <br />ISSUED <br />PO.1 <br />PLUMBING NOTES, SCHEDULES, AND DETAILS <br />YES <br />P1.0 <br />PLUMBING DEMOLITION PLAN <br />YES <br />P1.1 <br />PLUMBING RENOVATION PLAN <br />YES <br />TYPICAL PIPING INSULATION <br />DO NOT CRUSH <br />TYPICAL GALVANIZED <br />SHEET METAL SADDLE. <br />REFER TO SPECIFICATIONS - <br />TYPICAL 12 GAUGE <br />CHANNEL STRUT WITH <br />SLOTS <br />TYPICAL DOUBLE NUT WITH <br />SINGLE WASHER. TYPICAL <br />BOTH SIDES OF STRUT <br />TYPICAL ALL -THREAD <br />CONTINUOUS, ONE PIECE <br />HANGER ROD. COUPLING OF <br />RODS IS NOT PERMITTED - <br />TYPICAL STRUT MOUNTED <br />PIPE STRAP <br />NOTE: <br />LENGTH AS REQUIRED BY <br />NUMBER OF PIPES AND SIZES <br />REQUIRED <br />NOTE: <br />1. REFER TO SPECIFICATIONS AND FLOOR PLANS FOR MATERIAL AND SIZES <br />2. SPECIFIED HANGER ROD, STRUT, NUTS, WASHER, AND PIPE STRAPS SHALL B]OF <br />GALVANIZED PLATED MATERIALS <br />2 No Scale <br />HANGER <br />500 N. Westshore Blvd. <br />Suite 435 <br />Tampa, Florida 33609 <br />Phone: 813-637-0110 <br />ENGINEERING Fax: 813-637-0013 <br />FOR ARCHITECTURE WWW.tic-engineers.com <br />® Copyright 2014 TLC Engineering for Architecture, Inc. <br />COA 15 TLC NO:714026 <br />s <br />ON, US <br />- ;1� <br />C.i <br />H <br />d] <br />U <br />0 <br />c� <br />00 <br />b- <br />U M <br />M <br />© N IT, CJ� <br />r__4 <br />00 <br />�VZ <br />M di <br />b <br />p <br />b <br />� _ U <br />"1 M N <br />A <br />A <br />A <br />Q.7 <br />N <br />03 <br />4--o <br />. V-4 <br />03 <br />. r..r <br />O <br />4--t <br />V1 <br />W <br />E-+ <br />C) <br />Q) <br />03 <br />Project No. 714026 <br />PO* I <br />Q2014 BH/PK Architecta, Inc. <br />