<br />PLUMBING FIXTURE SCHEDULE
<br />WC-1 FLOOR MOUNTED ACCESSIBLE WATER CLOSET W/BEDPAN WASHER
<br />VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED, SIPHON JET, ELONGATED CLOSET BOWL WITH INTEGRAL
<br />BEDPAN LUGS, 1-1/2 INCH TOP SPUD.
<br />1.6 GALLON, CHROME PLATED FLUSH VALVE(EXPOSED), METAL OSCILLATING NON -HOLD OPEN HANDLE,
<br />1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM
<br />BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1/2" TOP SPUD, WALL AND SPUD FLANGES,
<br />SOLID RING PIPE SUPPORT, BEDPAN WASHER DIVERTER ASSEMBLY WITH WALL SUPPORT, PROVIDE
<br />OFFSET TO AVOID GRAB BAR, MOUNT FLUSH VALVE HANDLE MAX 44" A.F.F..
<br />CONTOURED SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH OPEN FRONT LESS COVER. SEAT SHALL
<br />INCLUDE STAINLESS STEEL SELF SUSTAINING CHECK HINGE FEATURE.
<br />BASIS OF DESIGN
<br />CHINA - AMERICAN STANDARD - 3043.156
<br />FLUSH VALVE - SLOAN ROYAL SLIMLINE BPW-1150-1.6
<br />SEAT - BEMIS - 1655--SS/C
<br />INTEGRAL COUNTER LAVATORY
<br />LAVATORY BOWL PROVIDED AS INTEGRAL PART OF COUNTERTOP BY ARCHITECTURAL, COORDINATE DRAIN
<br />CONNECTION AND FAUCET HOLE FOR THREE HOLE INSTALLATION.
<br />8 WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK SPOUT AND MAX.
<br />2 GPM FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE HANDLES WITH COLOR CODED INDEXES
<br />AND RENEWABLE SEATS IN MONEL. OUTLET OF SPOUT TO BE MINIMUM OF 5 INCHES ABOVE RIM OF
<br />FIXTURE.
<br />CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1 /4" O.D. TAILPIECE, CHROME PLATED 17 GAUGE
<br />1-1 /4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND TAILPIECE
<br />WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE COLLARS TO ALLOW
<br />PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE STOP AND
<br />WATER SUPPLY COVERS OF SAME MATERIAL.
<br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP
<br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE.
<br />BOWL - INTEGRAL WITH COUNTERTOP
<br />FAUCET - CHICAGO - 785-E29VP
<br />FAUCET - CHICAGO - 582-4-E29VP
<br />STRAINER/TRAP - MCGUIRE - 155A/PW 2150
<br />SUPPLIES - MCGUIRE - H170LK
<br />1 INTEGRAL COUNTER SINK
<br />SINK BOWL PROVIDED AS INTEGRAL PART OF COUNTERTOP BY ARCHITECTURAL, COORDINATE DRAIN
<br />CONNECTION AND FAUCET HOLE FOR THREE HOLE INSTALLATION.
<br />8" WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK SPOUT AND MAX.
<br />2 GPM FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE HANDLES WITH COLOR CODED
<br />INDEXES AND RENEWABLE SEATS IN MONEL. OUTLET OF SPOUT TO BE MINIMUM OF 5 INCHES ABOVE RIM
<br />OF FIXTURE.
<br />CHROME PLATED CAST BRASS GRID STRAINER WITH 1-1/4" O.D. TAILPIECE, CHROME PLATED 17 GAUGE
<br />1-1/4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND TAILPIECE
<br />WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE COLLARS TO
<br />ALLOW PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT AND COLD ANGLE
<br />STOP AND WATER SUPPLY COVERS OF SAME MATERIAL.
<br />3/8 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP
<br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE.
<br />BASIS OF DESIGN
<br />BOWL - INTEGRAL WITH COUNTERTOP
<br />FAUCET - CHICAGO - 785-E29VP
<br />FAUCET - CHICAGO - 582-4-E29VP
<br />STRAINER/TRAP - MCGUIRE - 155A/PW 2150
<br />SUPPLIES - MCGUIRE - H170LK
<br />1.00 - GENERAL PROVISIONS
<br />S 1 ACCESSIBLE SHOWER VALVE W/DIVERTER AND DRAIN
<br />ANTI -SCALD BALANCED PRESSURE CONCEALED SHOWER VALVE WITH STAINLESS STEEL BALANCING PISTON,
<br />VOLUME CONTROL, INTEGRAL SERVICE STOPS, INTEGRAL BI-METAL THERMOMETER WITH STAINLESS STEEL
<br />COMPONENTS MOUNTED IN SHATTERPROOF CASE AND ALL METAL CHROME PLATED TRIM.
<br />HAND SPRAY UNIT ON 30" WALL MOUNTED ADJUSTING BAR, FLEXIBLE METAL HOSE WITH WALL
<br />CONNECTION AND INTEGRAL IN -LINE VACUUM BREAKER. SHOWER HEAD WITH MAX. 2.5 GPM FLOW
<br />REGULATOR CHROME PLATED BRASS DIVERTER AND FIXED ADJUSTABLE SHOWER HEAD WITH FLANGE AND
<br />ARM, ALL TRIM SHALL BE COPPER NICKEL CHROME PLATED.
<br />COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLE MEMBRANE CLAMP AND
<br />ADJUSTABLE COLLAR WITH 6" ROUND TOP, NICKEL BRONZE STRAINER.
<br />BASIS OF DESIGN
<br />VALVE AND SHOWER HEAD SYSTEM - SYMMONS - 1-117VT-FS-B30
<br />SHOWER STALL DRAIN - ZURN Z-415
<br />5H-2 ACCESSIBLE SHOWER VALVE W/DIVERTER
<br />ANTI -SCALD BALANCED PRESSURE CONCEALED SHOWER VALVE WITH STAINLESS STEEL BALANCING PISTON,
<br />VOLUME CONTROL, INTEGRAL SERVICE STOPS, INTEGRAL BI-METAL THERMOMETER WITH STAINLESS STEEL
<br />COMPONENTS MOUNTED IN SHATTERPROOF CASE AND ALL METAL CHROME PLATED TRIM.
<br />HAND SPRAY UNIT ON 30" WALL MOUNTED ADJUSTING BAR, FLEXIBLE METAL HOSE WITH WALL
<br />CONNECTION AND INTEGRAL IN -LINE VACUUM BREAKER. SHOWER HEAD WITH MAX. 2.5 GPM FLOW
<br />REGULATOR CHROME PLATED BRASS DIVERTER AND FIXED ADJUSTABLE SHOWER HEAD WITH FLANGE AND
<br />ARM, ALL TRIM SHALL BE COPPER NICKEL CHROME PLATED.
<br />BASIS OF DESIGN
<br />VALVE AND SHOWER HEAD SYSTEM - SYMMONS - 1-117VT-FS-830
<br />GO MEDICAL GAS WALL OUTLET
<br />THE QUICK CONNECT RECESSED OUTLETS SHALL BE SUITABLE FOR THE SERVICES LISTED BELOW. OUTLETS
<br />SHALL CONSIST OF A ROUGHING IN ASSEMBLY AND A FINISHED ASSEMBLY.
<br />THE ROUGHING IN ASSEMBLY SHALL CONSIST OF A DIE-CAST BACK PLATE WITH MOUNTING FLANGES ON
<br />ALL FOUR SIDES, A RAISED PLASTER STRIKE, AND A NON - REMOVABLE POSITIVE PIN -KEYING
<br />ARRANGEMENT FOR EACH SPECIFIC GAS SERVICE. IDENTIFICATION OF EACH GAS SERVICE SHALL BE
<br />PERMANENTLY CAST INTO THE BACK PLATE AND CAN BE READ THROUGH A TRANSPARENT PLASTIC
<br />PLASTER GUARD.
<br />MOUNTED TO THE BACK PLATE IS A FULLY ASSEMBLED BRASS SECONDARY CHECK THAT IS COMPLETELY
<br />SERVICEABLE FROM THE FRONT. THE CHECK PREVENTS A GAS FLOW WHEN THE FINISHING ASSEMBLY IS
<br />REMOVED FOR MAINTENANCE OR SERVICE. THE SECONDARY CHECK VALVE INCLUDES 7-INCHES OF
<br />3/8-INCH O.D. TYPE K COPPER INLET TUBE WITH A LABEL IDENTIFYING THE SPECIFIC GAS BY NAME AND
<br />COLOR AND A PLASTIC DUST CAP. ROTATION OF THE INLET TUBE SHALL ALLOW GAS CONNECTION FROM
<br />THE TOP.
<br />THE FINISH ASSEMBLY SHALL CONSIST OF A STAINLESS STEEL FINISH PLATE, A DIE-CAST CHROME PLATED
<br />COVER PLATE, A MACHINED BRASS HOUSING FOR THE PRIMARY CHECK VALVE, THE SECONDARY CHECK
<br />VALVE, AND POSITIVE PIN -KEYING DEVICES TO PREVENT ACCIDENTAL INSTALLATION INTO A ROUGHING -IN
<br />ASSEMBLY OF A DISSIMILAR GAS. THE FINISHING ASSEMBLY SHALL INCORPORATE A DOUBLE SEAL WHICH
<br />AUTOMATICALLY ENGAGES WHEN A HOSE ADAPTER OR PATIENT TREATMENT DEVICE IS REMOVED FROM THE
<br />OUTLET.
<br />THE FINISHING ASSEMBLY SHALL BE DESIGNED IN ACCORDANCE WITH CGA V-5 STANDARD FOR DIAMETER
<br />INDEX SAFETY SYSTEM, THE EXPOSED PORTION OF QUICK CONNECT OUTLET CONNECTION SHALL BE
<br />POLISHED CHROME PLATE.
<br />GAS SERVICE COMPLETE ASSEMBLY
<br />BASIS OF DESIGN
<br />AMICO (CHEMETRON COMPATIBLE)
<br />OXYGEN - O-CHWAL-U-OXY - O-CHWAL-U-AIR
<br />VACUUM - 0-CHWAL-U-VAC
<br />VACUUM SLIDE - O-WALSLIDE
<br />NITROUS OXIDE - O-CHWAL-U-N20
<br />NITROGEN - O-DISWAL-E-NIT
<br />PLUMBING SPECIFICATIONS
<br />1.1 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING
<br />PLUMBING SYSTEM.
<br />1.2 CODES AND STANDARDS: ALL PLUMBING WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2010
<br />FLORIDA BUILDING CODE, PLUMBING AND ALL LOCAL CODES HAVING JURISDICTION.
<br />1.3 ALL PLUMBING WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER.
<br />1.4 CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED FOR THE
<br />EXECUTION OF THIS WORK.
<br />1.5 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE FABRICATION OR
<br />INSTALLATION. OFFSETS AND/OR TRANSITIONS REQUIRED SHALL BE PROVIDED WITHOUT
<br />ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL HIS WORK IN A TIMELY MANNER
<br />TO PREVENT DELAYS IN THE CONSTRUCTION.
<br />1.6 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT AND/OR
<br />MATERIAL.
<br />1.7 PROVIDE ALL MATERIALS REQUIRED TO PROPERLY SUPPORT ALL PIPING AND EQUIPMENT. PIPE
<br />HANGERS SHALL BE ADJUSTABLE TYPE AND BE SPACED IN ACCORDANCE WITH THE 2010 FLORIDA
<br />BUILDING CODE, PLUMBING PROVIDED PLASTIC COATED RING ON HANGERS FOR COPPER PIPING
<br />TO PROVIDE DIELECTRIC ISOLATION.
<br />1.8 PROVIDE DIELECTRIC UNIONS OR FLANGES BETWEEN COPPER AND STEEL PIPING AND BETWEEN
<br />BRASSWARE AND STEEL. DO NOT USE STEEL AND COPPER PIPING IN THE SAME SYSTEM WITHOUT
<br />SUCH ISOLATION.
<br />1.9 PROVIDE REDUCING FITTINGS (REDUCING BUSHINGS SHALL NOT BE USED) WHERE CHANGES IN
<br />PIPE SIZES OCCUR.
<br />1.10 THIS CONTRACTOR SHALL SUPPLY AND INSTALL ALL SERVICES THROUGHOUT THE BUILDING AND
<br />MAKE CONNECTION TO SITE UTILITIES APPROXIMATELY 5' On OUTSIDE THE BUILDING.
<br />CONTRACTOR SHALL SUPPLY AND INSTALL FIXTURES, FITTINGS, VALVING AND TRIM AND MAKE
<br />READY FOR USE ALL FIXTURES, EQUIPMENT, ETC.
<br />1.11 SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
<br />2.00 - BASIC MATERIALS AND METHODS
<br />2.1 ABOVEGROUND WATER PIPE AND FITTINGS - TYPE "L" COPPER, HARD DRAWN.
<br />2.2 PROVIDE UNIONS OR FLANGES IN ALL DOMESTIC WATER SERVICE LINES AT EACH PIECE OF
<br />EQUIPMENT, SPECIALTY VALVES OR AT OTHER LOCATIONS REQUIRED FOR READY DISCONNECT.
<br />2.3 WATER HAMMER ARRESTORS SHALL BE INSTALLED AT THE LOCATIONS ON THE PLANS AND IN
<br />ACCORDANCE WITH PDI STANDARD WH-201. PRODUCTS SHALL BE EQUAL TO THOSE
<br />MANUFACTURED BY PRECISION PLUMBING PRODUCTS OR SIOUX CHIEF.
<br />2.4 VALVES: PROVIDE VALVES TO ISOLATE EACH RISER, BRANCH LINE AND PIECE OF EQUIPMENT.
<br />2.5 PROVIDE PRESSURE REDUCING VALVE AND AIR GAP CONNECTION AT DISHWASHER AS REQUIRED
<br />BY CODE AND ACCORDING TO MANUFACTURER.
<br />2.6 ABOVEGROUND SANITARY WASTE, SANITARY VENT AND STORM PIPING - SERVICE WEIGHT CAST IRON
<br />WITH NO -HUB COUPLINGS - ("HUSKEY 4000" OR "CLAMPALL" ONLY).
<br />2.7 ABOVEGROUND SANITARY WASTE ARMS - SERVICE WEIGHT CAST IRON WITH NO -HUB COUPLINGS OR
<br />DWV COPPER.
<br />2.8 INSTALL GRAVITY LINES SLOPED AT 1/8" PER FOOT FOR PIPE 3" AND LARGER AND 1/4" PER
<br />FOOT FOR PIPE SMALLER THAT 3". VERIFY INVERT ELEVATION WITH SITE PIPING PRIOR TO ANY PIPE BEING
<br />INSTALLED.
<br />3.00 - PLUMBING FIXTURES AND TRIM
<br />3.1 ALL PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH IN COMMERCIAL
<br />STANDARD CS77-28 AS PROMULGATED BY THE U.S. DEPARTMENT OF COMMERCE.
<br />3.2 ALL FIXTURES ARE TO BE WHITE VITREOUS CHINA UNLESS OTHERWISE SPECIFICALLY NOTED.
<br />3.3 FIXTURES AND FITTINGS PROPOSED SHALL BE FROM ONE MANUFACTURER AND OF SIMILAR
<br />CHARACTER IN ANY ROOM OR LOCATION. ESCUTCHEONS, HANDLES, ETC., ON THE DIFFERENT FIXTURES
<br />SHALL BE OF THE SAME DESIGN,
<br />3.4 PROVIDE FIXTURE CARRIERS AS RECOMMENDED BY FIXTURE MANUFACTURER AND/OR
<br />CONSTRUCTION METHOD.
<br />3.5 PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON -ACCESSIBLE CEILINGS.
<br />REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.
<br />3.6 FLOOR DRAIN TRAP SEALS SHALL HAVE AN APPROVED AUTOMATIC PRIMING DEVICE DESIGNED FOR
<br />THAT PURPOSE.
<br />3.7 ALL CONCEALED TRAPS, PRIMERS, VALVES, CLEANOUTS, ETC. LOCATED IN TILED AREAS SHALL BE
<br />PROVIDED WITH AN ACCESS PANEL.
<br />4.00 - INSULATION
<br />4.1 ABOVE GROUND HOT WATER - FIBERGLASS, 1" THICKNESS, ASJ JACKET, DOUBLE SEALING LAP
<br />JOINT, 0.24 K AT 75"F. INSULATION AND ADHESIVES INSTALLED IN RETURN AIR PLENUMS SHALL HAVE A
<br />MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50.
<br />5.00 - VALVES AND COCKS
<br />5.1 VALVES 2" AND SMALLER SHALL BE BALL VALVES, 150 PSI SWP, 400 PSI WOG. STANDARD
<br />PORT BALL, BRONZE TRIM, CAST BRONZE BODY, CHROMIUM -PLATED BRASS BALL, BRONZE NON -BLOWOUT
<br />STEM, TEFLON SEAT, DOUBLE O-RING STEM SEALS, ZINC -COATED STEEL HANDLE WITH PLASTIC COATED HAND
<br />GRIP, 90 DEGREE OPERATION FROM FULL OPEN TO TIGHT SHUT-OFF - STOCKHAM S214-BR-T T, STOCKHAM
<br />S216-BR-T-S OR EQUAL.
<br />5.2 CHECK VALVES, ROUGH BRASS, REGRINDING BRONZE DISC - STOCKHAM B-345; B-309 OR EQUAL.
<br />6.00 - STERILIZATION
<br />6.1 DOMESTIC WATER PIPING SHALL BE THOROUGHLY FLUSHED OUT AND STERILIZED IN ACCORDANCE
<br />WITH THE 2010 FLORIDA BUILDING CODE, PLUMBING.
<br />PLUMBING SYMBOL LEGEND
<br />_-��- SYMBOL --_ DESCRIPTION
<br />AV ACID VENT
<br />AW - ACID WASTE
<br />----AW---- - BELOW GROUND ACID WASTE
<br />CD - ABOVE GROUND CONDENSATE DRAIN
<br />----- CD---- - BELOW GROUND CONDENSATE DRAIN
<br />CA - COMPRESSED AIR
<br />- DOMESTIC COLD WATER
<br />G
<br />GR
<br />ST
<br />---- ST -----
<br />STO
<br />---- STO ---
<br />M
<br />C01
<br />COI
<br />co
<br />FD 1113FD SC
<br />-
<br />(0)
<br />FS W
<br />ppG
<br />mc-
<br />wTw
<br />rC
<br />11,
<br />C
<br />= AP-XX
<br />1Q-XX
<br />11'1 r
<br />-,1 '11 MGV-XX
<br />zi
<br />- DOMESTIC HOT WATER
<br />- DOMESTIC HOT WATER RECIRCULATING
<br />- GAS
<br />- KITCHEN WASTE (GREASE)
<br />- ABOVE GROUND SANITARY
<br />- BELOW GROUND SANITARY
<br />- SANITARY VENT
<br />- EXISTING PIPING TO BE REMOVED
<br />- ABOVE GROUND STORM
<br />- BELOW GROUND STORM
<br />- OVERFLOW STORM DRAIN
<br />- BELOW GROUND OVERFLOW STORM
<br />- WATER METER
<br />- HOSE BIBB OR WALL HYDRANT
<br />- CLEAN OUT PLUG
<br />- WALL CLEANOUT
<br />- FLOOR CLEAN OUT
<br />- FLOOR DRAIN
<br />- ROOF DRAIN
<br />- FLOOR SINK
<br />- SHUT-OFF VALVE IN VALVE BOX
<br />- SHUTOFF VALVE
<br />- BALL VALVE
<br />- CALIBRATED BALANCING VALVE
<br />- CHECK VALVE (SWING)
<br />- PRESSURE REDUCING VALVE
<br />- SOLENOID OPERATED VALVE
<br />- REDUCED PRESSURE BACKFLOW PREVENTER
<br />- RELIEF OR SAFETY VALVE
<br />- GAS COCK
<br />GAS PRESSURE REGULATOR
<br />- SHUTOFF VALVE ON RISER
<br />- GAS COCK ON RISER
<br />- CONNECTION, TOP
<br />- CONNECTION, BOTTOM
<br />- ELBOW, TURNED DOWN
<br />- ELBOW, TURNED UP
<br />- TEE, TURNED UP
<br />- TEE, TURNED DOWN
<br />- CAP
<br />- DIRECTION OF FLOW
<br />- ALARM PANEL
<br />- MEDICAL GAS OUTLET
<br />- MEDICAL GAS VALVE BOX
<br />- CONNECT TO EXISTING
<br />- DEMOLISH TO POINT INDICATED
<br />- REVISION REFERENCE
<br />- DETAIL REFERENCE: TOP -DETAIL#,
<br />BOTTOM -DRAWING# SHOWN ON
<br />PLUMBING ABBREVIATIONS
<br />SYMBOL
<br />DESCRIPTION
<br />AFF
<br />- ABOVE FINISH FLOOR
<br />AW
<br />- ACID WASTE
<br />AV
<br />- ACID VENT
<br />CA
<br />- COMPRESSED AIR
<br />CD
<br />- CONDENSATE DRAIN
<br />CFH
<br />- CUBIC FEET PER HOUR
<br />CO
<br />- CLEANOUT
<br />CONT
<br />- CONTINUATION
<br />DCW
<br />- DOMESTIC COLD WATER
<br />DHW
<br />- DOMESTIC HOT WATER SUPPLY
<br />DHR
<br />- DOMESTIC HOT WATER RECIRCULATING
<br />DN
<br />- DOWN
<br />DS
<br />- DOWNSPOUT
<br />DWG
<br />- DRAWING
<br />EXIST
<br />- EXISTING
<br />'F
<br />- DEGREE FAHRENHEIT
<br />FCO
<br />- FLOOR CLEANOUT
<br />FD
<br />- FLOOR DRAIN
<br />FS
<br />- FLOOR SINK
<br />G
<br />- GAS
<br />GPH
<br />- GALLONS PER HOUR
<br />GPM
<br />- GALLONS PER MINUTE
<br />GR
<br />- KITCHEN WASTE (GREASE)
<br />HB
<br />- HOSE BIBB
<br />HD
<br />- HUB DRAIN
<br />IE
<br />- INVERT ELEVATION
<br />IW
<br />- INDIRECT WASTE
<br />KW
<br />- KILOWATT
<br />LBS
<br />- POUNDS
<br />MH
<br />- MANHOLE
<br />NC
<br />- NORMALLY CLOSED
<br />NIC
<br />- NOT IN CONTRACT
<br />NO
<br />- NORMALLY OPEN
<br />NTS
<br />- NOT TO SCALE
<br />OD
<br />- OUTSIDE DIAMETER
<br />PRV
<br />- PRESSURE REDUCING VALVE
<br />PSI
<br />- POUNDS PER SQUARE INCH
<br />PVC
<br />- POLYVINYL CHLORIDE PIPE
<br />RD
<br />- ROOF DRAIN
<br />RPBP
<br />- REDUCED PRESSURE BACKFLOW PREVENTOR
<br />SAN
<br />- SANITARY
<br />SD
<br />- STORM DRAIN
<br />SF
<br />- SQUARE FEET
<br />SH
<br />- SHEET
<br />ST
<br />- STORM
<br />STO
<br />- OVERFLOW STORM DRAIN
<br />V
<br />- VENT
<br />VAC
<br />- VACUUM
<br />VTR
<br />- VENT THRU ROOF
<br />WCO
<br />- WALL CLEANOUT
<br />WTR
<br />- WATER
<br />PLUMBING REPORTS/
<br />CERTIFICATIONS
<br />SYSTEM CHECKS TO BE COMPLETED PRIOR AND _DURING AHCA SURVEY
<br />MEDICAL GAS SYSTEMS TEST FOR THE RENOVATED ZONES.
<br />REQUIRED REPORTS AND CERTIFICATIONS
<br />- MEDICAL GAS CERTIFICATION FOR THE RENOVATED ZONES.
<br />- WATER PURIFICATION CERTIFICATE FOR THE RENOVATED AREA.
<br />ii A
<br />FLORIDA BUILDING CODE 2010 EDITION
<br />FLORIDA FIRE PREVENTION CODE 2010 EDITION
<br />FLORIDA ADMINISTRATION CODE 61G15 FAC
<br />NFPA 13, 2007 EDITION
<br />NFPA 14, 2007 EDITION
<br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
<br />INSULATED PIPE HANGER
<br />No Scab
<br />PIPE HANGER
<br />(SEE SPECS.)
<br />SHEETMETAL
<br />_E W/FLARED 1
<br />GENERAL NOTES
<br />1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS.
<br />2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES.
<br />3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW
<br />SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS
<br />PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON
<br />DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS
<br />DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY.
<br />4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS,
<br />WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF
<br />THE NEW WORK,
<br />5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE.
<br />SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES.
<br />SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING
<br />HOURS.
<br />6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS
<br />NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY
<br />ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN
<br />CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS AND OTHER
<br />POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES.
<br />7. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL
<br />ROOMS OR AS SPECIFICALLY NOTED.
<br />8. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE
<br />NON -ACCESSIBLE CEILINGS.
<br />9. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND
<br />FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR
<br />EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS
<br />FOR FINAL FINISHES.
<br />10. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH
<br />ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER.
<br />11. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE
<br />BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR.
<br />12. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
<br />13, PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS.
<br />14. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES,
<br />DEVICES, APPLIANCES AND APPARATUS.
<br />15. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED.
<br />16. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL
<br />CLEANOUT WITH COVER FLUSH TO FINISH SURFACE.
<br />17. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET
<br />FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN.
<br />18. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.)
<br />PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL
<br />PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE
<br />RE-ROUTED AT NO ADDITIONAL COST.
<br />19. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER
<br />DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE
<br />FIXTURE.
<br />20. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL
<br />CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS,
<br />ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS
<br />CONTRACTOR OR FURNISHED BY OTHERS.
<br />24. PROVIDE CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A. INSPECTION.
<br />PLUMBING DRAWING INDEX
<br />SHEET
<br />DESCRIPTION
<br />ISSUED
<br />PO.1
<br />PLUMBING NOTES, SCHEDULES, AND DETAILS
<br />YES
<br />P1.0
<br />PLUMBING DEMOLITION PLAN
<br />YES
<br />P1.1
<br />PLUMBING RENOVATION PLAN
<br />YES
<br />TYPICAL PIPING INSULATION
<br />DO NOT CRUSH
<br />TYPICAL GALVANIZED
<br />SHEET METAL SADDLE.
<br />REFER TO SPECIFICATIONS -
<br />TYPICAL 12 GAUGE
<br />CHANNEL STRUT WITH
<br />SLOTS
<br />TYPICAL DOUBLE NUT WITH
<br />SINGLE WASHER. TYPICAL
<br />BOTH SIDES OF STRUT
<br />TYPICAL ALL -THREAD
<br />CONTINUOUS, ONE PIECE
<br />HANGER ROD. COUPLING OF
<br />RODS IS NOT PERMITTED -
<br />TYPICAL STRUT MOUNTED
<br />PIPE STRAP
<br />NOTE:
<br />LENGTH AS REQUIRED BY
<br />NUMBER OF PIPES AND SIZES
<br />REQUIRED
<br />NOTE:
<br />1. REFER TO SPECIFICATIONS AND FLOOR PLANS FOR MATERIAL AND SIZES
<br />2. SPECIFIED HANGER ROD, STRUT, NUTS, WASHER, AND PIPE STRAPS SHALL B]OF
<br />GALVANIZED PLATED MATERIALS
<br />2 No Scale
<br />HANGER
<br />500 N. Westshore Blvd.
<br />Suite 435
<br />Tampa, Florida 33609
<br />Phone: 813-637-0110
<br />ENGINEERING Fax: 813-637-0013
<br />FOR ARCHITECTURE WWW.tic-engineers.com
<br />® Copyright 2014 TLC Engineering for Architecture, Inc.
<br />COA 15 TLC NO:714026
<br />s
<br />ON, US
<br />- ;1�
<br />C.i
<br />H
<br />d]
<br />U
<br />0
<br />c�
<br />00
<br />b-
<br />U M
<br />M
<br />© N IT, CJ�
<br />r__4
<br />00
<br />�VZ
<br />M di
<br />b
<br />p
<br />b
<br />� _ U
<br />"1 M N
<br />A
<br />A
<br />A
<br />Q.7
<br />N
<br />03
<br />4--o
<br />. V-4
<br />03
<br />. r..r
<br />O
<br />4--t
<br />V1
<br />W
<br />E-+
<br />C)
<br />Q)
<br />03
<br />Project No. 714026
<br />PO* I
<br />Q2014 BH/PK Architecta, Inc.
<br />
|