Laserfiche WebLink
a, <br />w <br />P <br />0 <br />.r <br />L� <br />i.. <br />4 � <br />E <br />M <br />ci <br />so o <br />LO <br />r;� <br />LO <br />c.� <br />00 <br />LO <br />Cn <br />w <br />I`__ <br />o <br />M Ld <br />w <br />c, CD <br />0 <br />I,.I <br />U <br />z <br />T_ <br />p <br />u) <br />a� <br />c <br />vs W <br />4 <br />Chi <br />a <br />o < <br />w <br />v <br />M <br />I <br />a� <br />N <br />T_ <br />I <br />co <br />CN <br />V <br />r�. <br />4 .n <br />0 <br />CD °d- <br />0 <br />cl� <br />.1�1 <br />HVAC SYMBOL LEGEND <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br />-CEILING DIFFUSER, ROUND NECK -FIRE DAMPER -TERMINAL UNIT, VARIABLE/CONSTANT AIR VOLUME <br />(CEILING DIFFUSERS ARE 4-WAY THROW UNO) (WITH ACCESS PANEL) <br />-FIRE & SMOKE DAMPER -TERMINAL UNIT, VARIABLE/CONSTANT AIR VOLUME <br />(WITH ACCESS PANEL) WITH ELECTRIC HEAT <br />-ROUND DIFFUSER <br />-�- ' -CEILING RETURN -EXISTING FIRE DAMPER TO REMAIN <br />L. _ J <br />-CEILING EXHAUST -EXISTING FIRE & SMOKE DAMPER TO REMAIN -ELECTRIC DUCT HEATER (W/ PANEL CLEARANCE) <br />-CEILING DIFFUSER, RECTANGULAR OR <br />SQUARE NECK (CEILING DIFFUSERS -MOTOR OPERATED CONTROL DAMPER (MOD) <br />ARE 4-WAY THROW UNO) M <br />L_J <br />-SUPPLY REGISTER OR GRILLE JFM -AIR FLOW MEASURING STATION <br />(� (VERTICAL MOUNT, SIDEWALL)-HYDRONIC REHEAT COIL <br />-RETURN/EXHAUST REGISTER OR GRILLE -MANUAL BALANCING DAMPER <br />(VERTICAL MOUNT, SIDEWALL)Al INLINE CENTRIFUGAL FAN <br />-DOOR GRILLE E---�-JI 1.�---I <br />-REVISION REFERENCE <br />t -DETAIL REFERENCE: TOP -DETAIL , -UP DN <br /># -CHANGE OF ELEVATION <br />M t BOTTOM -DRAWING# SHOWN ON -_ -'"- -- -UNDERCUT DOOR <br />Q -THERMOSTAT/TEMPERATURE SENSOR <br />-FLEXIBLE DUCT <br />Q-HUMIDISTAT/HUMIDITY SENSOR ® -ACCESS DOORS, VERTICAL OR HORIZONTAL <br />-TRANSITION, CONCENTRIC <br />-DUCT SMOKE DETECTOR <br />-STAINLESS STEEL DUCTWORK <br />�--.- -CONNECT TO EXISTING <br />III -FLEXIBLE CONNECTION -TRANSITION, ECCENTRIC <br />-DEMOLISH TO POINT INDICATED <br />Mom--- -MOTORIZED CONTROL DAMPER 12x8 e -FIAT OVAL DUCT 1Ox8 80 -TRANSITION, SQUARE TO ROUND <br />-TEMPERATURE SENSOR r <br />[]-- -PRESSURE SENSOR 24x12 -NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN /� WW/TURNI GRVANESLBOW <br />-BACKDRAFT DAMPER 2412 -EXISTING DUCTWORK TO REMAIN <br />�O -NEUTRAL RELATIVE PRESSURE----------------4 -RADIUS ELBOW <br />2402 -EXISTING DUCTWORK TO BE REMOVED <br />0+ -POSITIVE RELATIVE PRESSURE -2412 <br />0 -NEGATIVE RELATIVE PRESSURE -DUCT ELBOW, POSITIVE PRESSURE (SUPPLY), FIRST <br />DIMENSION INDICATES SIDE TO WHICH ARROW IS POINTING -RECTANGULAR/ROUND BRANCH TAKE -OFF <br />L J - -SHEET NOTE CALLOUT DOWN UP W/IN FLOOR OR ROUND/ROUND BRANCH TAKE -OFF <br />1Q----- -SHEET NOTE CALLOUT A 1 1 -DUCT ELBOW, EXHAUST �� rr <br />,_.,„�_._, -SQUARE THROAT TEE <br />- - -SHEET NOTE CALLOUT VII t -DUCT ELBOW, NEGATIVE PRESSURE, RETURN <br />® -CEILING MOUNTED ACCESS DOOR -DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE <br />® -RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE, 12x8 -RADIUS TEE <br />SUPPLY OR OUTSIDE AIR <br />-RECTANGULAR DUCT SECTION UP, <br />NEGATIVE PRESSURE, RETURN <br />® -RECTANGULAR DUCT SECTION UP, EXHAUST <br />RECTANGLE -TO- ROUND TAKE -OFF <br />-ROUND DUCT SECTION UP <br />-EXHAUST DUCT UP THROUGH SLAB W/ -STANDARD BRANCH TAKEOFF <br />FAN ON ROOF ABOVE <br />-EXHAUST FAN ON ROOF W/ DUCT DOWN THROUGH ROOF -SPIN-IN TAKE -OFF <br />HVAC PIPING SYMBOL LEGEND <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br />CWS -CONDENSER WATER SUPPLY -FLOW DIRECTION EIT <br />CWR -CONDENSER WATER RETURN -GATE VALVE - P-TRAP <br />CHWS -CHILLED WATER SUPPLY 6 -BALL VALVE <br />-MANUAL VENT <br />CHWR -CHILLED WATER RETURN '`A -CALIBRATING BALANCING VALVE <br />_CD -CONDENSATE 00 -BUTTERFLY VALVE � -PRESSURE GAUGE <br />CR -CONDENSATE RETURN -GAS COCK-�MM�.._.._ -FLOW METER <br />PC -PUMPED CONDENSATE ---------+I -UNION <br />M -WATER METER <br />HWR -HOT WATER RETURN -STRAINER -INLINE PUMP <br />HWS -HOT WATER SUPPLY '�' -CONTROL VALVE -INLINE PUMP <br />HPS -HIGH PRESSURE STEAM SUPPLY-•------C -SOLENOID VALVE L -CAP <br />MPS -MEDIUM PRESSURE STEAM SUPPLY 9" -PSI REG. -CONNECTION, BOTTOM <br />LPS -LOW PRESSURE STEAM SUPPLY -CHECK VALVE <br />I -CONNECTION, TOP <br />HPR -HIGH PRESSURE STEAM RETURN R -FLOW SWITCH <br />-COUPLING <br />MPR -MEDIUM PRESSURE STEAM RETURN -SLOPE DIRECTION (DOWN) -ELBOW, 90' <br />LPR -LOW PRESSURE STEAM RETURN -FLEX CONNECTION <br />�c�---- -ELBOW, 45' <br />------ RL--- -REFRIGERANT LIQUID -i-• -O.S.&Y. GATE VALVE <br />G -ELBOW, TURNED DOWN <br />RS -REFRIGERANT SUCTION -STEAM TRAP <br />a----r- � -ELBOW, TURNED UP <br />-THREE-WAY CONTROL VALVE <br />Q -TEE, OUTLET DOWN <br />-THERMOMETER -tom- -TEE, OUTLET UP <br />-TWO-WAY CHECK VALVE -45' PIPE RISE (R) / DROP (D) <br />-RELIEF VALVE -PIPE ANCHORS <br />-CONCENTRIC REDUCER <br />-VALVE ON RISER -ECCENTRIC REDUCER <br />DEMOw _}��R T -PIPING DEMOLITION <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT <br />SYMBOL <br />AFD <br />AFF <br />AFR <br />AHU <br />AP <br />BOP <br />BHP <br />BTU <br />CD <br />CT <br />CV <br />AP <br />AT <br />CFM <br />CU <br />DDC <br />DN <br />EAT <br />ESP <br />ETR <br />EWT <br />FCU <br />FD <br />FF <br />FLA <br />FPM <br />GPM <br />KW <br />LAT <br />LWT <br />HVAC ABBREVIATIONS <br />DESCRIPTION SYMBOL DESCRIPTION <br />-ADJUSTABLE FREQUENCY DRIVE <br />-ABOVE FINISHED FLOOR <br />-ABOVE FINISHED ROOF <br />-AIR HANDLING UNIT <br />-ACCESS PANEL <br />-BOTTOM OF PIPE <br />-BRAKE HORSEPOWER <br />-BRITISH THERMAL UNIT <br />-CENTER LINE <br />-CFM (CUBIC FEET PER MINUTE) <br />-CEILING DIFFUSER <br />-COOLING TOWER <br />-CONSTANT AIR VOLUME <br />-CHANGE IN PRESSURE <br />-CHANGE IN TEMPERATURE <br />-CUBIC FEET PER MINUTE <br />-CONDENSING UNIT <br />-DIRECT DIGITAL CONTROLS <br />-DOWN <br />-ENTERING AIR TEMPERATURE <br />-EXTERNAL STATIC PRESSURE <br />-EXISTING TO REMAIN <br />-ENTERING WATER TEMPERATURE <br />-FAN COIL UNIT <br />-FIRE DAMPER <br />-FINAL FILTERS <br />-FULL LOAD AMPS <br />-FEET PER MINUTE <br />-GALLONS PER MINUTE <br />-KILOWATT <br />-LEAVING AIR TEMPERATURE <br />-LEAVING WATER TEMPERATURE <br />LD -LINEAR DIFFUSER <br />MBH -THOUSAND BTUs PER HOUR <br />MCA -MINIMUM CIRCUIT AMPS <br />MOCP -MAXIMUM OVER CURRENT PROTECTION <br />MOD -MOTOR OPERATED CONTROL DAMPER (MOD) <br />NC -NORMALLY CLOSED <br />NO -NORMALLY OPEN <br />NTS --NOT TO SCALE <br />OA -OUTSIDE AIR <br />OAL -OUTSIDE AIR LOUVER <br />PRV -PRESSURE REDUCING VALVE <br />PRS -PRESSURE REDUCING STATION <br />PSI -POUNDS PER SQUARE INCH <br />PSIG -PSI GAUGE <br />PTAC -PACKAGED TERMINAL AIR CONDITIONER <br />PVC -POLYVINYL CHLORIDE PIPE <br />RA -RETURN AIR <br />RHC -REHEAT COIL <br />RHP -ROOFTOP HEAT PUMP <br />RPM -REVOLUTIONS PER MINUTE <br />RS/L -REFRIGERANT SUCTION & LIQUID LINES <br />RTU -ROOFTOP AIR HANDLING UNIT <br />SA -SUPPLY AIR <br />SP -STATIC PRESSURE <br />TSP -TOTAL STATIC PRESSURE <br />UNO -UNLESS NOTED OTHERWISE <br />V/PH -VOLTS/PHASE <br />VAV -VARIABLE AIR VOLUME <br />VFD -VARIABLE FREQUENCY DRIVE <br />MECHANICAL REPORTS/CERTIFICATIONS <br />SYSTEM CHECKS TO BE COMPLETED PRIOR AND DURING AHCA SURVEY <br />- HVAC SYSTEM START-UP/SHUTDOWN FOR ALL EQUIPMENT SERVING THE RENOVATED AREAS. <br />SMOKE DETECTOR SENSITIVITY TEST (SIGNED BY A LICENSED CONTRACTOR) FOR ALL EQUIPMENT <br />SERVING THE RENOVATED AREAS. <br />REQUIRED REPORTS AND CERTIFICATIONS <br />- HVAC PRE -TEST REPORT FOR THE ENTIRE UNITS SERVING THE RENOVATED AREAS PRIOR TO <br />CONSTRUCTION. <br />- HVAC TEST AND BALANCE REPORT FOR THE COMPLETED MECHANICAL SYSTEMS. <br />- PRESSURE DIFFERENTIAL TEST READINGS FOR ALL EXISTING DUCT MOUNTED SMOKE DETECTORS <br />CONNECTED TO THE UNITS SERVING THE RENOVATED AREAS. <br />- SMOKE DETECTOR ACTIVATION/SENSITIVITY TEST, INCLUDING THE RANGE. <br />HVAC DRAWING INDEX <br />SHEET DESCRIPTION ISSUED <br />MO.1 MECHANICAL LEGEND, GENERAL NOTES & SHEET INDEX Yes <br />MO.2 INFECTION CONTROL RISK ASSESMENT Yes <br />M1.0 MECHANICAL DEMOLITION PLAN Yes <br />M1.1 MECHANICAL RENOVATION PLAN Yes <br />M2.0 MECHANICAL DETAILS Yes <br />HVAC GENERAL NOTES <br />1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. <br />TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT <br />FURNISHED. <br />2. DIMENSIONS SHALL BE FIELD -VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR <br />FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS <br />SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE <br />TO OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR <br />PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH <br />AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, <br />PLUMBING, AND ELECTRICAL CONDUIT. <br />3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE <br />SMACNA HVAC DUCT CONSTRUCTION STANDARD. <br />4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK. <br />5, PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS, <br />6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT <br />EQUIPMENT FURNISHED. <br />7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL <br />REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES. <br />8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT <br />48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH <br />OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS. <br />9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. <br />PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE, RIGID <br />INSTALLATION. <br />10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. <br />11. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. <br />12. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR <br />PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED. <br />13. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR <br />OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT. <br />14. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING <br />VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL <br />TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. <br />15. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, <br />AIR HANDLING UNITS, AND FAN COIL UNITS. <br />16, INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR ALL TIMES NEEDED. SUCH <br />INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT <br />OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. <br />PRE -WORK SHALL BE PERFORMED TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE. <br />17. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL REMAIN PROPERTY OF THE <br />OWNER OR DISPOSED OF LEGALLY, AS DIRECTED BY OWNER. <br />18. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., <br />AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF <br />RATED WALLS. <br />19. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 25-0" CLEAR FROM ALL PLUMBING VENTS <br />AND EXHAUST AIR DISCHARGE LOCATIONS. LOWEST POINT OF EACH OUTSIDE AIR INTAKE ON <br />ROOF SHALL BE A MINIMUM OF 36" ABOVE ROOF. <br />20. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI. <br />21. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY <br />PIPED FULL SIZE TO THE NEAREST PLUMBING DRAIN. <br />22. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO <br />ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL <br />CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES <br />OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM <br />FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN <br />ACCORDANCE WITH NEC-110.26. <br />23. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL <br />AIR VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING. <br />24. PROVIDE DUCT SMOKE DETECTOR ACCESS AT THE EXISTING AIR HANDLING UNITS THAT SERVE <br />THE RENOVATED AREA IF MISSING OR INSUFFICIENT. PROVIDE MINIMUM ONE CEILING TILE <br />ACCESS IN FRONT OF DUCT MOUNTED SMOKE DETECTORS AND AS SHOWN ON FLOOR PLAN. <br />DEMOLITION NOTES <br />1. THE CONTRACTOR SHALL PROVIDE PROTECTION FOR ALL PARTS OF THE BUILDING. ITS <br />APPLICABLE CODES AND STANDARDS I <br />CONTENTS AND OCCUPANTS WHEREVER WORK UNDER THIS CONTRACT IS PERFORMED. <br />FLORIDA BUILDING CODE 2010 EDITION <br />FLORIDA FIRE PREVENTION CODE 2010 EDITION <br />FLORIDA ADMINISTRATION CODE 61G15 FAC <br />FLORIDA GUIDELINES INSTITUTE 2010 EDITION <br />NFPA 13, 2007 EDITION <br />NFPA 14, 2007 EDITION <br />HVAC EQUIPMENT TAGS <br />/-TAG <br />A 200 <br />`-CFM <br />/_AHU NUMBER <br />AH-1 <br />-AIR DISTRIBUTION DEVICE <br />-AIR HANDLING UNIT <br />AHU NUMBER -,\,\," COIL NUMBER <br />HC-1-1 -REHEAT COIL <br />VARIABLE/CONSTANT AIR VOLUME TERMINAL UNITS <br />TERMINAL UNIT TYPE - AHU NUMBER <br />VTU - VARIABLE TERMINAL UNIT <br />CTU -CONSTANT TERMINAL UNIT TERMINAL NUMBER <br />PTU - PARALLEL TERMINAL UNIT VTU -1-1 <br />STU - SERIES TERMINAL UNIT <br />2. AREA UNDER CONSTRUCTION MUST BE MAINTAINED TO HAVE A NEGATIVE PRESSURE IN <br />RELATION TO ADJACENT SPACES OF A MINIMUM 0.03" WC. TEMPORARY FILTRATION TO BE <br />PROVIDED ON THE RETURN AIR GRILLES OF ANY AREAS THAT ARE WITHIN THE CONSTRUCTION <br />ZONE AND OPERATE DURING PERIODS OF CONSTRUCTION. THESE FILTERS TO BE REMOVED <br />AND ANY PERMANENT FILTERS IN THIS SYSTEM ARE TO BE REPLACED AT THE CONCLUSION <br />OF THIS PROJECT. ALL DUCT AND PIPING OPENINGS IN CONSTRUCTION AREA ARE TO BE <br />SEALED AND PROTECTED DURING DEMOLITION/CONSTRUCTION. <br />3. DEMOLITION SHALL INCLUDE REMOVAL OF EXISTING BUILDING CONSTRUCTION TO EXTENT <br />REQUIRED TO PERFORM CONSTRUCTION ACTIVITIES INDICATED. <br />4. THE DEMOLITION PROCEDURES SHALL PROVIDE FOR SAFE CONDUCT OF THE WORK, <br />PROTECTION OF PERSONNEL, CAREFUL REMOVAL AND DISPOSITION OF MATERIALS SPECIFIED <br />TO BE SALVAGED, PROTECTION OF PROPERTY TO REMAIN UNDISTURBED, COORDINATION WITH <br />OTHER WORK IN PROGRESS, AND TIMELY DISCONNECTION OF UTILITY SERVICES. <br />5. EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE, WORK DAMAGED BY THE <br />CONTRACTOR SHALL BE REPAIRED TO MATCH EXISTING WORK OR WORK INSTALLED UNDER <br />THIS CONTRACT DEPENDING ON CONTRACT REQUIREMENTS. <br />6. EXISTING WORK SHALL BE CUT, DRILLED, ALTERED, REMOVED OR TEMPORARILY REMOVED AND <br />REPLACED FOR PERFORMANCE OF WORK UNDER THE CONTRACT. WORK REPLACED SHALL <br />MATCH SIMILAR EXISTING WORK. STRUCTURAL MEMBERS OF CONCRETE OR STRUCTURAL STEEL <br />SHALL NOT BE CUT OR ALTERED, EXCEPT AS SHOWN WITHOUT AUTHORIZATION OF THE <br />OWNER. WORK REMAINING IN PLACE DAMAGED OR DEFACED DURING THIS CONTRACT SHALL BE <br />RESTORED TO THE CONDITION AT TIME OF AWARD OF CONTRACT. CUT, ALTER, REMOVE OR <br />TEMPORARILY REMOVE AND REPLACE EXISTING WORK FOR THE INSTALLATION OF MECHANICAL, <br />PLUMBING AND ELECTRICAL WORK AND OTHER CONSTRUCTION. <br />7. PROPERLY REMOVE AND DISPOSE OF ALL EXISTING FIXTURES AS REQUIRED TO ACCOMMODATE <br />NEW PLAN. REFER TO THE ARCHITECTURAL DEMOLITION PLANS. CONSULT WITH THE OWNER <br />AND OBTAIN OWNERS APPROVAL PRIOR TO DISPOSAL OF REMOVED MATERIAL. <br />8. UNLESS INDICATED OTHERWISE, ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, PIPING, <br />WIRING, HANGERS AND SUPPORTS SHALL BE REMOVED BACK TO BELOW SLAB, ABOVE <br />CEILING, OR WITHIN WALL CAVITIES AS INDICATED ON THE DRAWINGS. REFER TO THE <br />ARCHITECTURAL DEMOLITION PLANS. CONSULT WITH THE OWNER AND OBTAIN OWNERS <br />APPROVAL PRIOR TO DISPOSAL OF REMOVED MATERIAL. <br />9. THE EXISTING EQUIPMENT INDICATED ON THESE DRAWINGS WAS COMPILED FROM ORIGINAL <br />CONSTRUCTION DRAWINGS, 'AS -BUILT" DRAWINGS AND ENGINEERS FIELD OBSERVATIONS. THE <br />EXISTING EQUIPMENT INDICATED REPRESENTS A BEST FAITH EFFORT BY THE ENGINEER TO <br />DEMONSTRATE THE CONDITIONS UNDER WHICH THE WORK IS TO BE EXECUTED. THE <br />CONTRACTOR SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS TO THE DEGREE AND <br />EXTENT NECESSARY TO PREPARE A PROPER AND ADEQUATE BID FOR THE WORK INDICATED. <br />SUBMISSION OF A BID WILL BE INTERPRETED AS MEANING THE CONTRACTOR HAS REVIEWED <br />EXISTING CONDITIONS AND UNDERSTANDS THE DIFFICULTIES AND CHALLENGES UNDER WHICH <br />THE WORK IS TO BE ACCOMPLISHED. <br />500 N. Westshore Blvd. <br />Suite 435 <br />Tampa, Florida 33609 <br />Phone: 813-637-0110 <br />ENGINEERING Fax: 813-637-0013 <br />FOR ARCHITECTURE wwwAlc-engineers.com <br />a Copyright 2014 TLC Engineering for Architecture, Inc. <br />COA 15 TLC NO:714026 <br />I <br />0MO-AMUN <br />U <br />4-1 <br />Q.� <br />+-i <br />U <br />c <br />A <br />00 <br />U a, <br />0 �. <br />M <br />O CA 44 a, <br />cdM�N <br />kn <br />v <br />00 44 <br />a <br />p <br />b <br />U <br />ER <br />Q <br />1 <br />Q.7 <br />N <br />V- 4 <br />as <br />A-4 <br />. V-1 <br />Cn <br />GC3 <br />W <br />d <br />UD <br />rU-s CIS <br />U CI:3 <br />Project No. 714026 <br />mo's <br />Q2014 BH/PK Architects, Inc, <br />