DEMOLITION GENERAL NOTES
<br />b
<br />03
<br />Ln
<br />z
<br />c�
<br />0
<br />N
<br />O
<br />O
<br />O
<br />O
<br />tL
<br />a
<br />G DEMOLITION KEY NOTES
<br />I . EXISTING CEILING GRID AND TILE TO REMAIN. REPLACE ANY DAMAGED OR DIRTY TILES WITH NEW
<br />TO MATCH EXISTING.
<br />2. EXISTING CEILING GRID TO REMAIN, REMOVE EXISTING TILE. REFER TO SHEET A2 FOR EXTENTS OF NEW TILE.
<br />3. REMOVE CEILING AND GRID AS SHOWN (VERIFY WITH PROJECT MANAGER). REFER TO REFLECTED CEILING PLAN
<br />FOR NEW WORK. REWORK HVAC AIR DEVICES AND ASSOCIATED DUCTWORK ONLY IF REQUIRED.
<br />4. NOT U5LD
<br />5. NOT USED
<br />G. NOT USED
<br />7. EXISTING DIFFUSERS AND RETURN GRILLES TO REMAIN.
<br />8, NO3 USED
<br />9. EXISTING CEILING MOUNTED EXHAUST FAN TO REMAIN.
<br />10. NOT USED
<br />I NOT USED
<br />€ 2. NOT U5ED
<br />13. IF NECESSARY, REMOVE AND RELOCATE MOTION SENSORS, DOOR CONTACTS, CAMERAS AND SECURITY 5Y5TE EQUIPMENT
<br />VERIFY WITH PROJECT MANAGER. REFER TO SECURITY PLAN FOR NEW AND RELOCATED CAMERAS
<br />AND ASSOCIATED WIRING.
<br />14. EXISTING LIGHT FIXTURE TO REMAIN.
<br />15. REMOVE EXISTING LIGHT FIXTURE AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER
<br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF
<br />SALVAGED FIXTURE5.
<br />I G. EXISTING EXIT LIGHT/ EMERGENCY UNIT TO REMAIN,
<br />17. REMOVE EXIT LIGHT/EMERGENCY UNIT AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER
<br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF
<br />SALVAGED FIXTURES.
<br />15. EXISTING CEILING RECEPTACLE5 TO REMAIN.
<br />19. N01- USED
<br />20. REMOVE EXISTING EVAPORATOR, DISCONNECT POWER AND REFRIGERANT PIPING.
<br />2 1 . REMOVE EXISTING EVAPORATOR FOR RELOCATION, DISCONNECT POWER AND REFRIGERANT PIPING. REFER TO MECHANICAL
<br />SHEETS.
<br />22. EXISTING CAMERAS TO REMAIN.
<br />23, NOT USED
<br />24. NO WORK IN THIS AREA, UNLESS NOTED OTHERWISE.
<br />25, NOT USED
<br />2G. EXISTING EXTERIOR SOFFIT, LIGHTING AND COMPONENT TO REMAIN.
<br />27. EXISTING CEILING MOUNTED EVAPORATOR TO REMAIN.
<br />25. EXISTING SPEAKERS TO REMAIN.
<br />29. EXISTING CEILING MOUNTED AIR -CURTAIN TO BE REMOVED.
<br />30. NO U5ED
<br />3 1. EXISTING WI-FI CONNECTION TO REMAIN.
<br />32. REMOVE EXISTING POWER POLE AND ALL A550CIATED WIRING BACK TO PANEL.
<br />u
<br />LEGEND
<br />0
<br />0
<br />CEILING DEMOLITION PLAN
<br />SCALE: 114" = I '- 0"
<br />SEE DEMOLITION KEY NOTES
<br />EXISTING CEILING GRID, LIGHTS, AND EQUIPMENT,
<br />ETC. TO REMAIN.
<br />EXISTING CEILING GRID, LIGHTS, AND EQUIPMENT,
<br />BULKHEAD, WALL, ETC. TO BE REMOVED AND / OR
<br />RELOCATED
<br />4'-TWO - LAMP FLUORESCENT
<br />LOW -PROFILE WRAP AROUND FIXTURE.
<br />RECESSED LIGHTING.
<br />RECESSED LIGHTING.
<br />COMBINATION EXIT 51GN AND DUALITE
<br />EMERGENCY LAMP5.
<br />EMERGENCY LIGHTING UNIT W/ 2 HEADS.
<br />DUALITE OUTDOOR LXT05 WITH
<br />MINIMUM OF 90 MINUTE BACK-UP
<br />BATTERY. INSTALL ONLY WHEN
<br />REQUIRED BY CODE.
<br />A. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH
<br />PERSPECTIVE TRADES. BUILDING / FIRE / HEALTH OFFICIALS, AND OWNER'S
<br />REPRESENTATIVE.
<br />B. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, LOAD
<br />BEARING WALLS, AND STRUCTURAL ITEMS PRIOR TO STARTING WORK.
<br />NOTIFY AND COORDINATE WITH OWNER'S REPRESENTATIVE ALL
<br />DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION
<br />DOCUMENTS.
<br />C. LEGALLY DISPOSE ALL REMOVED MATERIALS PER GOVERNING AUTHORITIES
<br />AND AS DIRECTED BY OWNER'S REPRESENTATIVE. ALL DEBRIS SHALL BE
<br />REMOVED FROM THE SITE, UNLESS PLACED IN APPROVED CONTAINERS.
<br />D. ALL TEMPORARY SUPPORTS, SHORING AND BRACING ETC. SHALL BE
<br />DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. SUBMIT TO
<br />OWNER'S REPRESENTATIVE FOR APPROVAL.
<br />E. DEMOLITION EQUIPMENT THAT PRODUCES EXCESSIVE NOISE SHALL BE
<br />OPERATED ONLY WHEN ADJOINING BUSINESSES ARE CLOSED, OR AS
<br />COORDINATED WITH ALL CONCERNED PARTIES AND LOCAL MUNICIPALITY
<br />RESTRICTION.
<br />F. ALL HAZARDOUS MATERIAL REMOVAL, ASBESTOS ABATEMENT, LEAD PAINT
<br />ENCAPSULATION PROCEDURES ARE TO MEET E.P.A. AND LOCAL
<br />REQUIREMENTS.
<br />G. REMOVE ALL FLOOR FINISHES AND PREP SUB -FLOORS TO RECEIVE NEW
<br />FLOOR FINISHES AS INDICATED ON THE FLOOR FINISH PLAN. COORDINATE
<br />RESILIENT FLOORING REMOVAL WITH ASBESTOS ASSESSMENT REPORT.
<br />H. THE GENERAL CONTRACTOR SHALL COORDINATE AND PROVIDE A WRITTEN
<br />RECORD, TO THE OWNER'S REPRESENTATIVE, OF ALL SALVAGED FIXTURES,
<br />TRIMS, EQUIPMENT, CABINET, ETC. PRIOR TO DEMOLITION. ALL DECOR
<br />ITEMS ARE THE RESPONSIBILITY OF THE OWNER, HOWEVER, THE GENERAL
<br />CONTRACTOR SHALL PROVIDE A SECURE AND ADEQUATE STORAGE AREA
<br />FOR SUCH ITEMS.
<br />I. THE GENERAL CONTRACTOR SHALL REMOVE ALL FIXTURES AND EQUIPMENT
<br />(SHOWN DASHED). THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR THE
<br />RECORDING OF EXISTING EQUIPMENT. LOCATIONS, CONNECTION TYPES, AND
<br />ROUGH -INS, AS WELL AS, NEW ROUGH -INS AND ALL FINAL CONNECTIONS, AS
<br />REQUIRED FOR ALL REUSED AND RELOCATED EQUIPMENT.
<br />J. THIS PLAN INDICATES ONLY THE APPROXIMATE DEMOLITION REQUIRED FOR
<br />COMPLETION OF THI5 REMODEL. EXISTING CONDITIONS NOT SHOWN OR
<br />NOTED SHALL REMAIN UNCHANGED UNLESS APPROVED BY THE ARCHITECT
<br />OR OWNER'S REPRESENTATIVE. ALL EXISTING MATERIALS ADJACENT TO THE
<br />NEW CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND FINISHED TO
<br />PROVIDE A SMOOTH, LEVEL, AND UNNOTICEABLE TRANSITION BETWEEN NEW
<br />AND EXISTING FINISHES.
<br />K. EXISTING MATERIALS MAY BE REUSED ONLY IF SPECIFICALLY NOTED, OR, IF
<br />PRIOR APPROVAL IS OBTAINED FROM THE OWNER'S REPRESENTATIVE.
<br />REUSED MATERIALS SHALL, EITHER BE REAPPLIED AND / OR REFINISHED TO A
<br />LIKE NEW CONDITION IN A C05T EFFECTIVE WAY, OR NEW MATERIALS SHALL
<br />BE USED.
<br />L. THOROUGHLY CLEAN, PATCH AND REPAIR ALL EXISTING SURFACES TO A LIKE
<br />NEW CONDITION. PROVIDE PROPER PREPARATION FOR ALL SURFACES TO
<br />RECEIVE NEW FINISHES. COORDINATE FINI5HE5 WITH CONSTRUCTION
<br />DOCUMENTS AND / OR OWNER'S REPRESENTATIVE.
<br />M. SEE ARCHITECTURAL, PLUMBING, AND ELECTRICAL SHEETS FOR ADDITIONAL
<br />CONCRETE SLAB REMOVAL. PATCH AND REPAIR SLAB AS REQUIRED TO
<br />MATCH EXISTING.
<br />N. REMOVE ALL UNUSED OR ABANDONED PLUMBING, MECHANICAL, AND
<br />ELECTRICAL ITEMS IN THEIR ENTIRETY AND PROVIDE PROPER CAP
<br />TERMINATION BELOW THE SLAB. COORDINATE WITH LOCAL BUILDING AND
<br />UTILITY OFFICIALS. REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW
<br />CONSTRUCTION. SEE PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS
<br />FOR ADDITIONAL DEMOLITION AND / OR RELOCATION INFORMATION.
<br />O. THE GENERAL CONTRACTOR SHALL PROVIDE AN ASSESSMENT OF ALL
<br />EXISTING ROOFING TO REMAIN. ALL DAMAGED FLASHING, COPING,
<br />MEMBRANE, SHINGLES, TILES, ETC. SHALL BE REPAIRED TO PROVIDE A
<br />WATERTIGHT BUILDING ENVELOPE. UNUSED OR ABANDONED ROOFTOP
<br />ITEMS SHALL BE REMOVED AND ROOF OPENINGS SHALL BE CLOSED AND
<br />ROOFED WITH SIMILAR MATERIALS. ROOF DRAINS SHALL BE CLEARED AND
<br />REPAIRED AS REQUIRED AND WORKING OVERFLOWS SHALL BE PROVIDED.
<br />SEE ROOF PLAN FOR ADDITIONAL NOTES AND NEW ROOFING CONDITIONS.
<br />P. REMOVE ALL EXTRANEOUS MATERIALS FROM FLOORS, WALLS, AND CEILINGS
<br />WHICH ARE NOT APPLICABLE TO THE NEW OR EXISTING CONSTRUCTION.
<br />ITEMS INCLUDE BUT ARE NOT LIMITED TO: ELECTRIC OUTLETS, CONDUITS,
<br />DUCTWORK; CEILING ANGLES, DRYWALL, FRAMING, FURRING, SOFFITS,
<br />MECHANICAL ITEMS, ELECTRICAL ITEMS, PLUMBING ITEMS, HANGERS, AND
<br />RELATED CONSTRUCTION DEBRIS.
<br />Q. PREVENT FUBLIC ACCESS TO WORK AREA. INSTALL BARRIERS AND SIGNAGE
<br />TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND CONTRACTORS OF
<br />DANGER.
<br />R. CONTRACTOR SHALL SET THEIR SAW BLADES NO DEEPER THAN 3 1 /2" WHEN
<br />SAW CUTTING FLOOR.
<br />NORTH
<br />+ COOLER/ FREEZER LIGHTING
<br />SPEAKER
<br />0o CEILING MOUNTED RECEPTACLE
<br />Qn SECURITY CAMERA
<br />OR Z
<br />SUPPLY DIFFUSER
<br />OR z z RETURN AIR GRILLE/ EXHAUST GRILLE.
<br />CEILING SYSTEM
<br />Loco
<br />O
<br />W 0 i
<br />I -j ci
<br />o
<br />a
<br />�cc
<br />o a
<br />O m
<br />U N
<br />O co
<br />z
<br />O cn j:z- II
<br />I ) 1
<br />a=_
<br />W } O
<br />U L I
<br />'X96612
<br />ci
<br />STIPUM I-15E
<br />THIS DRAWING WAS SPECIFICALLY
<br />PREPARED FOR USE IN REGARD5 TO THE
<br />PERMITTING AND CONSTRUCTION OF THIS
<br />PROJECT AND 15 NOT SUITABLE FOR USE
<br />FOR ANY OTHER PROJECT. USE OF THIS
<br />DRAWING FOR REFERENCE OR EXAMPLE
<br />ON ANOTHER PROJECT REQUIRES THE
<br />SERVICES OF PROPERLY LICENSED
<br />ARCHITECTS AND ENGINEERS.
<br />REPRODUCTION OF THIS DRAWING FOR
<br />REUSE ON ANOTHER PROJECT 15 NOT
<br />AUTHORIZED AND MAY BE CONTRARY TO
<br />THE LAW.
<br />o u�
<br />O
<br />Lo
<br />>
<br />�S
<br />C�
<br />my
<br />3a
<br />'a
<br />�n
<br />N L
<br />o
<br />�o
<br />LL1
<br />C)
<br />®
<br />o
<br />cm
<br />m
<br />z
<br />LL
<br />J
<br />z
<br />_
<br />LJ
<br />y
<br />W
<br />IN
<br />LLJ
<br />STORE OR
<br />BLDG NO.
<br />/ Q
<br />G6 58
<br />VERSION OR
<br />PROJECT ID
<br />751 1 93-0
<br />SCALE O
<br />4'
<br />1 /4" = P-0"
<br />DESIGN TEAM
<br />DATE
<br />DGNR.
<br />P.MGR.
<br />CESO
<br />0G.24.2015
<br />RVWR.
<br />JAD
<br />DRWG. NO.
<br />G858- D-2
<br />KE
<br />
|