Laserfiche WebLink
DEMOLITION GENERAL NOTES <br />f. <br />Q <br />Ln <br />03 <br />SR <br />0 <br />z <br />0 <br />N <br />O <br />O <br />0 <br />0 <br />J <br />LL <br />N <br />io <br />O II 0 IL Ul - - L-JEE2qELEC. 2z 3o ELEC.JIT I 0 1 <br />L------�L_-- J 23 22 30 L----J <br />STORAGE/ a ^ ---- -3 ---_- 9 COOLER <br />r - - IL 4 <br />N / 1r 1r------- -, <br />28 <br />�L---- JL------- JL--------- J 12 <br />r-­11 11 - II --- II III/ 'i 0 I 0 - - <br />L - JL- JL JI II III' J / 1 1 \ s <br />\ ---- L====JL-J _z <br />4 I I 4 \�// 3 35 <br />J--- / 7 f '//� � <br />r , r (� �l FOOD SERVICE/� 20 27 r\ <br />II I II I 3 AREA <br />II I 3 LJ �--� 10 17 �la , 40 <br />m II I 22 33 r - - - - - 1 177 '/J / / � 3 / \ 12 <br />leiIII I <br />r --I I _ I ��/ %��/77 �TTT7 % TTT7 <br />r I v -,1 1 z- 111-1 1 L 111 i / / �` \ 3 I I I I 16 <br />1 \ \ \ \ \L� \ J 3 �� I I1 3 0 <br />LLB <br />� __-1 20 27 1 L_-1 �� I 7 ----� 5 I // /' I I _ <br />1 (D31 ❑ L_JC� 1 �I/ j / // // 6 <br />12 <br />LJL_----- /' I/ I // / / I � I I --I L- J <br />1 -� -- r--7 <br />IG <br />ON <br />(D I I <br />^ <br />SALES AREA <br />l0 17 ��� // \\\ // / I \\1 O 111 <br />34 O I I 22 33 ' 3 / / 1 <-,I Ili r----� 18 <br />a 4 I \ II 0 <br />p z3 \ \ / / / \I I L_L -=-_J <br />5--- <br />OFFICE \\j <br />29 I r - \\ O3 \\ 4 MEN'S <br />9 O 3/� <br />_ RESTROOM <br />IF I ATTENDANT i II I LO IIr 1 v <br />AREA I I I 1031 F- <br />29 <br />9 I L-J I O <br />O I 0001 11 <br />3 r � 11 1I 7 <br />(3 13 <br />OFFICE 1 I LD I' /' L <br />/�\ II I 0-1 O 1 I LII I II 34 --------- WOMEN S <br />F---� =1 0 - -___-J IL _--, _ r-� I I RESTROOM <br />r --11r �� -11 IF -Ir � 10110 <br />11 0 11 0 1 29 <br />OI I J I II 11 II II I I L--I`--JL---JL----------J <br />18 <br />34 <br />I . EQUIPMENT / FURNITURE TO REMAIN. COORDINATE ANY REPAIRS WITH <br />PROJECT MANAGER. <br />2. EQUIPMENT / FURNITURE TO BE REMOVED AND STORED IN A SAFE <br />PLACE TO BE REINSTALLED IN NEW LOCATION PER REMODEL PLANS. <br />COORDINATE WORK WITH PROJECT MANAGER. CONTRACTOR SHALL BE <br />RESPONSIBLE FOR REMOVAL AND INSTALLATION OF EQUIPMENT PER <br />PLANS AND INSTRUCTIONS OF PROJECT MANAGER. REMOVE ALL <br />PLUMBING AND ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO <br />SOURCE UNLESS OTHERWISE NOTED ON PLUMBING AND ELECTRICAL <br />DRAWINGS. <br />3. EQUIPMENT / FURNITURE TO BE REMOVED. COORDINATE WORK WITH <br />PROJECT MANAGER. GENERAL CONTRACTOR SHALL BE RESPONSIBLE <br />FOR REMOVAL AND DISPOSAL OF EQUIPMENT UNLESS OTHERWISE <br />INSTRUCTED BY PROJECT MANAGER. REMOVE ALL PLUMBING AND <br />ELECTRICAL ASSOCIATED WITH EQUIPMENT BACK TO SOURCE UNLESS <br />OTHERWISE NOTED ON PLUMBING AND ELECTRICAL DRAWINGS. <br />4. WALL(5) / PARTITION(S) TO REMAIN. REFER TO FLOOR PLAN FOR EXTENT <br />OF NEW WORK REQUIRED ON EXISTING WALL. FINISH MATERIALS TO <br />REMAIN UNLESS OTHERWISE NOTED. REFER TO FINISH PLAN. <br />5. PROJECT MANAGER AND CONTRACTOR SHALL COORDINATE WITH <br />MARKETING DEPARTMENT FIELD MERCHANDISER FOR REMOVAL OF <br />EXISTING GONDOLA EQUIPMENT. <br />G. REMOVE MERCHANDISING AND STORAGE RACKS, AND / OR SHELV(NG. <br />COORDINATE WITH PROJECT MANAGER FOR REUSE OF SHELVING AND <br />STORAGE OF MERCHANDISE. GONDOLA SHELVING RELOCATION MAY <br />ALREADY BE COMPLETED BY OTHERS BEFORE REMODEL. VERIFY AT <br />BID WALK. <br />7. REMOVE CABINETRY AND COUNTERS. <br />8. NOT USED <br />9. EXISTING EQUIPMENT * FURNITURE TO REMAIN "A5-I5". <br />10. REMOVE WALL FINISHES, GRAPHICS, AND APPLICATIONS TO ALLOW <br />FOR INSTALLATION OF NEW CABINETRY AND/ OR MERCHANDISING <br />EQUIPMENT. INSTALL STRAIGHT AND PLUMB. REFER TO FINISH PLAN. <br />COORDINATE WITH PROJECT MANAGER. <br />1 1 . REMOVE WALL / PARTITION. REMOVE ACCESSIBLE GAS, PLUMBING, <br />ELECTRICAL, AND TELEPHONE FEEDERS. CAP ALL INACCESSIBLE <br />UTILITIES PER APPLICABLE CODES AND INDUSTRY STANDARDS. <br />12. REMOVE COOLER PANELS AND COOLER DOORS AS NEEDED FOR NEW <br />COOLER LAYOUT. <br />13. NOT USED <br />14, NOT USED <br />15. NOT USED <br />I G. REMOVE EXISTING FLOOR FINISH FROM THIS AREA. PREPARE EXISTING <br />CONCRETE SUBFLOOR FOR NEW CONCRETE SEALER. AREA TO RECEIVE <br />NEW WALK-IN CAVE. REFER TO ARCHITECTURAL SHEETS. <br />17. EXISTING FLOOR TILE TO REMAIN. <br />18. EXISTING SIDEWALK TO REMAIN. <br />19. NOT USED <br />20. COORDINATE SAW CUTS OF CONCRETE SLAB WITH PLUMBING AND <br />ELECTRICAL DRAWINGS. CONTRACTOR TO DETERMINE PRIOR TO <br />CUTTING OF SLAB IF SLAB IS STRUCTURAL. NOTIFY PROJECT MANAGER <br />IMMEDIATELY IF STRUCTURAL SLAB EXISTS. REFER TO THIS SHEET FOR <br />APPROXIMATE LOCATIONS OF SAW CUTS. <br />2 1 . NOT USED <br />22. REFER TO UTILITY DRAWINGS FOR EXTENT OF MECHANICAL, PLUMBING, <br />AND ELECTRICAL DEMOLITION. <br />23, EXISTING PLUMBING FIXTURES TO REMAIN. <br />24. NOT USED <br />25. NOT U5ED <br />2G. NOT USED <br />27. IF NECESSARY REMOVE EXISTING FLOOR TILE. EXISTING SLAB TO BE <br />PREPARED FOR NEW FINISH. SEE FINISH SCHEDULE. <br />28. EXISTING COOLER/ FREEZERTO REMAIN. <br />29. NO WORK IN THIS AREA. UNLESS NOTED OTHERWISE. <br />30. EXISTING ELECTRICAL EQUIPMENT TO REMAIN. <br />3 1. NOl' USED <br />32. NOT USED <br />33. SEE PLUMBING DRAWINGS FOR REMOVAL OF PLUMBING PIPING. TEST <br />PIPING SYSTEM FOR LEAKS PRIOR TO RETURNING TO SERVICE. <br />34. EXISTING PARKING TO REMAIN. <br />35. EXISTING COOLER DOORS TO REMAIN. <br />3G. NOT USED <br />37. NOT USED <br />38: NOT USE <br />39. NOT USED <br />40. EXISTING BULK CO2 TANK TO REMAIN. <br />DEMOLITION PLAN <br />D- I SCALE: 1 J4" = 1 ' - 0" <br />►wz�v <br />Z� <br />A. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH O v • <br />RESPECTIVE TRADES. BUILDING / FIRE / HEALTH OFFICIALS, AND OWNERS C�<q <br />H o <br />REPRESENTATIVE. W <br />J o <br />a <br />B. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, LOAD c <br />BEARING WALLS, AND STRUCTURAL ITEMS PRIOR TO STARTING WORK. O in <br />NOTIFY AND COORDINATE WITH OWNER'S REPRESENTATIVE ALL U ) • <br />DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION i0 in <br />DOCUMENTS. Z <br />C. LEGALLY DISPOSE ALL REMOVED MATERIALS PER GOVERNING m <br />AUTHORITIES AND AS DIRECTED BY OWNER'S REPRESENTATIVE. ALL Q -'alDEBRIS SHALL BE REMOVED FROM THE SITE, UNLESS PLACED IN W r a <br />APPROVED CONTAINERS. U U.) • <br />D. ALL TEMPORARY SUPPORTS, SHORING AND BRACING ETC. SHALL BE <br />DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. SUBMIT TO <br />OWNER'S REPRESENTATIVE FOR APPROVAL. <br />E. DEMOLITION EQUIPMENT THAT PRODUCES EXCESSIVE NOISE SHALL BE <br />OPERATED ONLY WHEN ADJOINING BUSINESSES ARE CLOSED, OR AS <br />COORDINATED WITH ALL CONCERNED PARTIES AND LOCAL MUNICIPALITY <br />RESTRICTION. ,` dy W NC3 <br />F. ALL HAZARDOUS MATERIAL REMOVAL, ASBESTOS ABATEMENT, LEAD <br />PAINT ENCAPSULATION PROCEDURES ARE TO MEET E.P.A. AND LOCAL <br />REQUIREMENTS. ?J 96622 ' <br />A..G. REMOVE ALL FLOOR FINISHES AND PREP SUB -FLOORS TO RECEIVE NEW / T <br />FLOOR FINISHES AS INDICATED ON THE FLOOR FINISH PLAN. <br />COORDINATE RESILIENT FLOORING REMOVAL WITH ASBESTOS 'RED ARC`r <br />ASSESSMENT REPORT. <br />STIPULATION FOR REUSE <br />H. THE GENERAL CONTRACTOR SHALL COORDINATE AND PROVIDE A WRITTEN THI5 DRAWING WAS SPECIFICALLY <br />RECORD, TO THE OWNER'S REPRESENTATIVE, OF ALL SALVAGED PREPARED FOR USE IN REGARDS TO THE <br />FIXTURES, TRIMS, EQUIPMENT, CABINET, ETC. PRIOR TO DEMOLITION. ALL PERMITTING AND CONSTRUCTION OF THIS <br />DECOR ITEMS ARE THE RESPONSIBILITY OF THE OWNER, HOWEVER, THE PROJECT AND IS NOT SUITABLE FOR USE <br />FOR ANY OTHER PROJECT. USE OF THIS <br />GENERAL CONTRACTOR SHALL PROVIDE A SECURE AND ADEQUATE DRAWING FOR REFERENCE OR EXAMPLE <br />STORAGE AREA FOR SUCH ITEMS. ON ANOTHER PROJECT REQUIRES THE <br />SERVICES OF PROPERLY LICENSED <br />ARCHITECTS AND ENGINEERS. <br />I. THE GENERAL CONTRACTOR SHALL REMOVE ALL FIXTURES AND REPRODUCTION OF THIS DRAWING FOR <br />EQUIPMENT (SHOWN DASHED). THE GENERAL CONTRACTOR 15 REUSE ON ANOTHER PROJECT 15 NOT <br />RESPONSIBLE FOR THE RECORDING OF EXISTING EQUIPMENT. AurnoRlzeD AND MAYBE conlTRaRYTo <br />THE LAW. <br />LOCATIONS, CONNECTION TYPES, AND ROUGH-IN5, AS WELL AS, NEW <br />ROUGH -INS AND ALL FINAL CONNECTIONS, AS REQUIRED FOR ALL <br />REUSED AND RELOCATED EQUIPMENT. <br />J. THIS PLAN INDICATES ONLY THE APPROXIMATE DEMOLITION REQUIRED <br />FOR COMPLETION OF THIS REMODEL. EXISTING CONDITIONS NOT SHOWN <br />OR NOTED SHALL REMAIN UNCHANGED UNLESS APPROVED BY THE <br />ARCHITECT OR OWNER'S REPRESENTATIVE. ALL EXISTING MATERIALS <br />ADJACENT TO THE NEW CONSTRUCTION SHALL BE PATCHED, REPAIRED, <br />AND FINISHED TO PROVIDE A SMOOTH, LEVEL, AND UNNOTICEABLE <br />TRANSITION BETWEEN NEW AND EXISTING FINISHES. <br />K. EXISTING MATERIALS MAY BE REUSED ONLY IF SPECIFICALLY NOTED, OR, <br />IF PRIOR APPROVAL 15 OBTAINED FROM THE OWNER'S REPRESENTATIVE. <br />REUSED MATERIALS SHALL, EITHER BE REAPPLIED AND / OR REFINISHED <br />TO A LIKE NEW CONDITION IN A C05T EFFECTIVE WAY, OR NEW <br />MATERIALS SHALL BE USED. <br />L. THOROUGHLY CLEAN, PATCH AND REPAIR ALL EXISTING SURFACES TO A <br />LIKE NEW CONDITION. PROVIDE PROPER PREPARATION FOR ALL <br />SURFACES TO RECEIVE NEW FINISHES. COORDINATE FINISHES WITH <br />CONSTRUCTION DOCUMENTS AND / OR OWNER'S REPRESENTATIVE. <br />M. SEE ARCHITECTURAL, PLUMBING, AND ELECTRICAL SHEETS FOR <br />ADDITIONAL CONCRETE SLAB REMOVAL. PATCH AND REPAIR SLAB AS <br />REQUIRED TO MATCH EXISTING. <br />N. REMOVE ALL UNUSED OR ABANDONED PLUMBING, MECHANICAL, AND <br />ELECTRICAL ITEMS IN THEIR ENTIRETY AND PROVIDE PROPER CAP <br />TERMINATION BELOW THE SLAB. COORDINATE WITH LOCAL BUILDING AND <br />UTILITY OFFICIALS. REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW <br />CONSTRUCTION. SEE PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS <br />FOR ADDITIONAL DEMOLITION AND / OR RELOCATION INFORMATION. <br />0. THE GENERAL CONTRACTOR SHALL PROVIDE AN ASSESSMENT OF ALL <br />EXISTING ROOFING TO REMAIN. ALL DAMAGED FLASHING, COPING,o <br />MEMBRANE, SHINGLES, TILES, ETC. SHALL BE REPAIRED TO PROVIDE A <br />WATERTIGHT BUILDING ENVELOPE. UNUSED OR ABANDONED ROOFTOP o <br />ITEMS SHALL BE REMOVED AND ROOF OPENINGS SHALL BE CLOSED AND <br />ROOFED WITH SIMILAR MATERIALS. ROOF DRAINS SHALL BE CLEARED o0 ° <br />AND REPAIRED AS REQUIRED AND WORKING OVERFLOWS SHALL BE N <br />PROVIDED. SEE ROOF PLAN FOR ADDITIONAL NOTES AND NEW ROOFING <br />CONDITIONS. �a m <br />c� 3 <br />P. REMOVE ALL EXTRANEOUS MATERIALS FROM FLOORS, WALLS, AND <br />CEILINGS WHICH ARE NOT APPLICABLE TO THE NEW OR EXISTING <br />CONSTRUCTION. ITEMS INCLUDE BUT ARE NOT LIMITED TO: ELECTRIC <br />OUTLETS, CONDUITS, DUCTWORK, CEILING ANGLES, DRYWALL, FRAMING, o <br />z L <br />FURRING, SOFFITS, MECHANICAL ITEMS, ELECTRICAL ITEMS, PLUMBING O <br />ITEMS, HANGERS, AND RELATED CONSTRUCTION DEBRIS. Lo o <br />Q. PREVENT PUBLIC ACCESS TO WORK AREA. INSTALL BARRIERS AND <br />51GNAGE TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND N <br />CONTRACTORS OF DANGER. <br />3 <br />R. CONTRACTOR SHALL SET THEIR SAW BLADES NO DEEPER THAN 3 1 /2" ¢ <br />WHEN SAW CUTTING FLOOR. <br />5 <br />>m <br />1 tj <br />0 <br />z <br />LEGEND <br /># SEE DEMOLITION KEY NOTES <br />-J <br />O <br />O <br />EXISTING WALLS TO REMAIN <br />QD <br />- <br />tL <br />C) <br />EXISTING, WALL, EQUIPMENT, FURNITURE ETC. TO <br />� <br />- - - - BE REMOVED AND / OR RELOCATED <br />� <br />W <br />O:�E <br />AREA OF FLOOR SLAB TO BE REMOVED TO TRENCH <br />rr T FOR UTILITIES. COORDINATE W/ PLUMBING AND <br />� 1J � <br />N <br />Q <br />ELECTRICAL DRAWINGS <br />STORE OR <br />13LDG No. <br />G 8 5 8 <br />VERSION OR <br />PROJECT ID <br />75 1 1 93-01 <br />SCALE 0 <br />4' <br />114" = 1'-0' <br />DESIGN TEAM <br />DATE <br />DGNK. <br />P.MGK. <br />CESO <br />OG.24.2015 <br />RVWR. <br />JAD <br />DRWG. N0. <br />