<br />MECHANICAL PLAN
<br />SCALE: 1/4" = I'-0" 0 6" 1' 2' 4'
<br />(9 0
<br />FOR NEW DUCTWORK:
<br />FLEXIBLE DUCT EXTENSION TO CEILING
<br />DIFFUSERS SHALL NOT EXCEED 4'-0"
<br />EXISTING AIR CONDITIONING
<br />CONDENSING UNITS TO
<br />REMAIN
<br />GENERAL MECHANICAL NOTE5:
<br />A. CONTRACTORS SHALL SUPPLY (G) COPIES OF SHOP DRAWINGS TO PROJECT MANAGERS SO THAT QUALITY OF
<br />CONTRACTOR 5UPFLIED EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS CAN BE REVIEWED PRIOR TO
<br />INSTALLATION. CONTRACTOR AND VENDOR MECHANICAL DRAWINGS SHALL INCLUDE:
<br />1. PLAN VIEW, SECTIONS, AND ELEVATIONS OF ADDITIONAL MECHANICAL 5Y5TEM5, EQUIPMENT, FIXTURES, AND
<br />APPLIANCES.
<br />2. APPLICABLE CODES FOR INSTALLATION.
<br />B. CONTRACTOR 15 RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, LICENSES, AND FEES NECESSARY TO COMPLETE
<br />WORK PER CONSTRUCTION DOCUMENTS AND APPLICABLE CODES. CONTRACTOR SHALL REQUEST AND MAKE
<br />ARRANGEMENTS FOR NEW AND TEMPORARY UTILITY SERVICES PRIOR TO START OF CON5TRUCTION.
<br />C. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED A5 EVIDENCE THAT CONTRACTOR HAS FAMILIARIZED
<br />HIMSELF WITH THE CONSTRUCTION DOCUMENTS, CONSTRUCTION SITE, AND 15 PREPARED TO PROVIDE A
<br />COMPLETE INSTALLATION PER THESE CONSTRUCTION DOCUMENTS, ALL APPLICABLE CONSTRUCTION CODES,
<br />AND MANUFACTURER'S RECOMMENDATIONS. WHERE CONDITIONS REQUIRE THAT CHANGES BE MADE TO THE
<br />CONTRACT DOCUMENTS, AND THOSE CHANGE5 DO NOT ALTER THE SCOPE OR NATURE OF THE ORIGINAL WORK,
<br />CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL C05T TO OWNER,
<br />D. THE OWNER SHALL SUPPLY ONLY EQUIPMENT, FIXTURES, AND APPLIANCES SPECIFIED A5 'OWNER SUPPLIED'.
<br />CONTRACTOR SHALL BE RESPONSIBLE FOR IN5TALLING ALL OWNER SUPPLIED EQUIPMENT, FIXTURES AND
<br />APPLIANCES, AND FOR PROVIDING AND INSTALLING ALL OTHER EQUIPMENT, FIXTURES, APPLIANCES AND
<br />MATERIALS NOT SUPPLIED AND INSTALLED BY VENDORS. ALL EQUIPMENT, FIXTURE5, APPLIANCES, AND
<br />MATERIALS PROVIDED BY CONTRACTOR SHALL BE NEW, UNUSED, L15TED AND LABELED FOR USE. CONTRACTOR
<br />SHALL INSTALL ALL EQUIPMENT, FIXTURES, AND APPLIANCES IN COMPLIANCE WITH LABELING OF LISTING AGENCY,
<br />MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODE5 AND REGULATIONS, AND CONSTRUCTION DOCUMENT5.
<br />WHERE CONFLICT EXISTS, NOTIFY ENGINEER OF RECORD FOR ADJUDICATION.
<br />E. BALANCE UNIT FAN5 PER DE51GN STATIC PRESSURE DIFFERENTIALS, SPEEDS AND AMPERAGE DRAWS. SUBMIT
<br />AN AIR BALANCE REPORT TO PROJECT MANAGER.
<br />F. ALL DUCT SIZES ARE IN51DE DIMENSIONS. CONSTRUCT AND INSTALL DUCT SYSTEM PER'SMACNA' DUCT
<br />CONSTRUCTION STANDARDS. SEAL ALL TRANSVERSE AND LONGITUDINAL JOINTS USING ADHESIVES, GASKETS
<br />OR TAPE COMPATIBLE WITH DUCT CLASSIFICATION. PRESSURE SENSITIVE TAPE SHALL NOT BE USED A5 A
<br />PRIMARY SEALANT, PROVIDE A SEAL AGAINST BOTH POSITIVE AND NEGATIVE PRESSURES.
<br />G. ALL AIR -HANDLING DUCT SHALL BE THERMALLY INSULATED TO MINIMUM R-G. RECTANGULAR DUCT MAY BE SHEET
<br />METAL OR I " FIBERGLASS, CLA55 I DUCT BOARD, L15TED PER UL 16 1 . ROUND DUCT MAY BE SHEET METAL OR
<br />FLEXIBLE FIBERGLA55. FLEXIBLE DUCT 5HALL NOT BE USED AS AN ELBOW, FLEXIBLE DUCT SHALL NOT EXCEED 4'
<br />IN LENGTH. ALL DUCT SHALL BE INSTALLED FEK'5MACNA' 5TANDARD5 AND MANUFACTURER'S
<br />RECOMMENDATIONS. TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR DUCT ELBOWS.
<br />H. RUNOUT DUCT SIZES SHALL BE SAME SIZE ROUND DUCT AS DIFFUSER NECK 51ZE UNLESS INDICATED
<br />OTHERWISE.
<br />I. ALL FIELD INSTALLED ELECTRICAL WIRING SHALL BE STRANDED COPPER CONDUCTORS WITH 75 DEG C.
<br />WATER-RESISTANT INSULATION, AND BE INSTALLED PER THE LATEST EDITION OF NFPA 70.
<br />J. CONTRACTOR SHALL PERFORM IN -PLACE, FULL FUNCTIONAL TESTS OF ALL MECHANICAL SYSTEMS, EQUIPMENT,
<br />FIXTURES AND APPLIANCES: AND THESE MECHANICAL SYSTEMS SHALL BE MADE TO OPERATE PER
<br />MANUFACTURER'S SPECIFICATIONS PRIOR TO JOB COMPLETION.
<br />K. ALL ABANDONED DUCTWORK SHALL BE REMOVED FROM SITE.
<br />® MECHANICAL KEYN OTE5
<br />1. INSTALL ACCUREX MODEL XO TYPE II OVEN HOOD, 48"W X 481 X 24"H. HOOD FURNISHED BY OWNER. MOUNT AT
<br />7-2" A.F.F. FABRICATE AND INSTALL BRACKETS REQUIRED TO MOUNT HOOD. ROUTE DUCT VERTICALLY.
<br />COORDINATE EXHAUST DUCT ROUTING WITH BUILDING STRUCTURE, WATER PIPING, AND ELECTRICAL CONDUITS.
<br />l e% ��p' •GEN
<br />`.v•.�� S•.c�o
<br />�Ir ; • ,k
<br />to A E U ,
<br />✓, 1
<br />STIPULATION FOR REUSE
<br />THI5 DRAWING WAS SPECIFICALLY
<br />PREPARED FOR USE IN REGAP.D5 TO THE
<br />PERMITTING AND CONSTRUCTION OF THI5
<br />PROJECT AND 15 NOT SUITABLE FOR USE
<br />FOR ANY OTHER PROJECT. USE OF THIS
<br />DRAWING FOR REFERENCE OR EXAMPLE
<br />ON ANOTHER PROJECT REQUIRE5 THE
<br />5EPVICI-5 OF PROPERLY LICENSED
<br />ARCHITECTS AND ENGINEERS.
<br />REPRODUCTION OF THIS DRAWING FOR
<br />REUSE ON ANOTHER PROJECT 15 NOT
<br />AUTHORIZED AND MAY BE CONTRARY TO
<br />THE LAW.
<br />2.
<br />1 4/ 1 0 EXHAUST DUCT UP TO 51DEWALL EXHAUST FAN EF- I . MAINTAIN 1 0'-0" MIN TO RTU AIR INTAKE. PROVIDE
<br />so
<br />N
<br />AND INSTALL BACKDRAFT DAMPER. ADJUST FAN AIRFLOW PER EXHAUST FAN SCHEDULE.
<br />°
<br />5
<br />n
<br />N
<br />m
<br />o �
<br />3.
<br />NOT USED.
<br />oo
<br />o
<br />4,
<br />EXISTING FUKNACE(5) IN ATTIC SPACE TO REMAIN. REFER TO SCHEDULE ON SHEET M-2 FOR UNIT INFORMATION.
<br />4
<br />N
<br />MAINTAIN MANUAL OUTSIDE AIR DAMPER AND REBALANCE TO CFM INDICATED IN BUILDING AIR BALANCE
<br />SCHEDULE ON DRAWING M-2.
<br />�
<br />y
<br />y
<br />5.
<br />EXISTING THERM05TAT(5) TO REMAIN. RELOCATE A5 REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.
<br />z
<br />z
<br />z
<br />W
<br />W
<br />LJ
<br />O N
<br />N
<br />G.
<br />NOT USED.
<br />o
<br />7.
<br />EXISTING SUPPLY AIR DIFFUSER TO REMAIN.
<br />Fn
<br />m
<br />0
<br />0
<br />0
<br />o�
<br />o
<br />8.
<br />NOT USED.
<br />Lu
<br />L
<br />a
<br />N
<br />9.
<br />NOT USED.
<br />'cl
<br />�
<br />Lu
<br />'z
<br />z
<br />o
<br />O
<br />O
<br />O
<br />N L
<br />10.
<br />EXISTING RETURN AIR GRILLE TO REMAIN.
<br />O
<br />�`o
<br />z
<br />1 1. NOT USED.
<br />12,
<br />NOT USED.
<br />13.
<br />EXISTING RE5TROOM EXHAUST FAN TO REMAIN.
<br />Q
<br />>
<br />m
<br />14.
<br />EXISTING CONDENSER TO REMAIN.
<br />i
<br />il—
<br />J
<br />15,
<br />NOT USED.
<br />J LL
<br />�
<br />Q
<br />I G.
<br />RELOCATE EXISTING EVAPORATOR A5 NECESSARY. FURGE, MODIFY, AND RECHARGE REFRIGERANT LINES A5
<br />z
<br />NECESSARY.
<br />_
<br />.
<br />— (
<br />17.
<br />INSTALL VENDOR SUPPLIED EVAPORATOR(5) IN COOLER PER MANUFACTURER'S REQUIREMENTS.
<br />U
<br />18,
<br />INSTALL LINE -SET AND 4-CONDUCTOR CONTROL WIRING FROM GRADE MOUNTED CONDENSING UNIT TO UNIT
<br />COOLERS/ MERCHANDISING EQUIPMENT. DOUBLE INSULATE AND PROTECT EXTERIOR LINE -SET USING 2" FOAM
<br />W
<br />WRAP AND 5CH.40 PVC CONDUIT TO [ROOF / WALL] PENETRATION. [INSTALL LINE -SET THROUGH CHEMICAL CURB
<br />N
<br />OR SIMILAR ROOF PENETRATION SEALING SYSTEM.] INSULATE BOTH LIQUID AND SUCTION LINES INSIDE BUILDING
<br />U51NG I " FOAM WRAP. PROVIDE ADDITIONAL REFRIGERANT WHERE LENGTH OF LINE -SET EXCEEDS FACTORY
<br />6858
<br />CHARGE CAPACITY. MAKE FINAL CONNECTIONS, MECHANICAL CONTRACTOR 15 RESPONSIBLE FOR5EALING ALL
<br />[ROOF / BUILDING] PENETRATIONS FOR MECHANICAL EQUIPMENT WATERTIGHT, COORDINATE WITH OTHER
<br />BLDGNOR
<br />TRADES.
<br />VEK51ON OR
<br />7 5 1 1 9 3 -01
<br />PROJECT ID
<br />19.
<br />INSTALL CONDENSING UNITS ON EQUIPMENT RAILS ON CONCRETE. CONDENSING UNIT FURNISHED BY OWNER.
<br />5CALE 0
<br />4'
<br />MAINTAIN MINIMUM REQUIRED CLEARANCES: 3'-0" TO PARAPET WALLS, AND 2'-0" TO ADJACENT UNIT5.
<br />20.
<br />INSTALL NEW ROOF MOUNTED EQUIPMENT TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA MECHANICAL
<br />1/4"= 1-0"
<br />CODE SECTION 30 1 . 1 2 REGARDING WIND RESISTANCE.