Laserfiche WebLink
r <br />W' <br />co <br />Ln <br />CO <br />i <br />w <br />J <br />lL <br />z <br />Q � <br />rV N <br />w co <br />(s) Lf) <br />E <br />�O <br />� w <br />-U <br />Ln <br />— -Z <br />O <br />N <br />t` <br />� O <br />n.:� <br />18 19 20 18 19 20 <br />� IOWR <br />MECHANICAL PLAN <br />SCALE: 1/4" = I'-0" 0 6" 1' 2' 4' <br />(9 0 <br />FOR NEW DUCTWORK: <br />FLEXIBLE DUCT EXTENSION TO CEILING <br />DIFFUSERS SHALL NOT EXCEED 4'-0" <br />EXISTING AIR CONDITIONING <br />CONDENSING UNITS TO <br />REMAIN <br />GENERAL MECHANICAL NOTE5: <br />A. CONTRACTORS SHALL SUPPLY (G) COPIES OF SHOP DRAWINGS TO PROJECT MANAGERS SO THAT QUALITY OF <br />CONTRACTOR 5UPFLIED EQUIPMENT, FIXTURES, APPLIANCES, AND MATERIALS CAN BE REVIEWED PRIOR TO <br />INSTALLATION. CONTRACTOR AND VENDOR MECHANICAL DRAWINGS SHALL INCLUDE: <br />1. PLAN VIEW, SECTIONS, AND ELEVATIONS OF ADDITIONAL MECHANICAL 5Y5TEM5, EQUIPMENT, FIXTURES, AND <br />APPLIANCES. <br />2. APPLICABLE CODES FOR INSTALLATION. <br />B. CONTRACTOR 15 RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, LICENSES, AND FEES NECESSARY TO COMPLETE <br />WORK PER CONSTRUCTION DOCUMENTS AND APPLICABLE CODES. CONTRACTOR SHALL REQUEST AND MAKE <br />ARRANGEMENTS FOR NEW AND TEMPORARY UTILITY SERVICES PRIOR TO START OF CON5TRUCTION. <br />C. SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED A5 EVIDENCE THAT CONTRACTOR HAS FAMILIARIZED <br />HIMSELF WITH THE CONSTRUCTION DOCUMENTS, CONSTRUCTION SITE, AND 15 PREPARED TO PROVIDE A <br />COMPLETE INSTALLATION PER THESE CONSTRUCTION DOCUMENTS, ALL APPLICABLE CONSTRUCTION CODES, <br />AND MANUFACTURER'S RECOMMENDATIONS. WHERE CONDITIONS REQUIRE THAT CHANGES BE MADE TO THE <br />CONTRACT DOCUMENTS, AND THOSE CHANGE5 DO NOT ALTER THE SCOPE OR NATURE OF THE ORIGINAL WORK, <br />CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL C05T TO OWNER, <br />D. THE OWNER SHALL SUPPLY ONLY EQUIPMENT, FIXTURES, AND APPLIANCES SPECIFIED A5 'OWNER SUPPLIED'. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR IN5TALLING ALL OWNER SUPPLIED EQUIPMENT, FIXTURES AND <br />APPLIANCES, AND FOR PROVIDING AND INSTALLING ALL OTHER EQUIPMENT, FIXTURES, APPLIANCES AND <br />MATERIALS NOT SUPPLIED AND INSTALLED BY VENDORS. ALL EQUIPMENT, FIXTURE5, APPLIANCES, AND <br />MATERIALS PROVIDED BY CONTRACTOR SHALL BE NEW, UNUSED, L15TED AND LABELED FOR USE. CONTRACTOR <br />SHALL INSTALL ALL EQUIPMENT, FIXTURES, AND APPLIANCES IN COMPLIANCE WITH LABELING OF LISTING AGENCY, <br />MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODE5 AND REGULATIONS, AND CONSTRUCTION DOCUMENT5. <br />WHERE CONFLICT EXISTS, NOTIFY ENGINEER OF RECORD FOR ADJUDICATION. <br />E. BALANCE UNIT FAN5 PER DE51GN STATIC PRESSURE DIFFERENTIALS, SPEEDS AND AMPERAGE DRAWS. SUBMIT <br />AN AIR BALANCE REPORT TO PROJECT MANAGER. <br />F. ALL DUCT SIZES ARE IN51DE DIMENSIONS. CONSTRUCT AND INSTALL DUCT SYSTEM PER'SMACNA' DUCT <br />CONSTRUCTION STANDARDS. SEAL ALL TRANSVERSE AND LONGITUDINAL JOINTS USING ADHESIVES, GASKETS <br />OR TAPE COMPATIBLE WITH DUCT CLASSIFICATION. PRESSURE SENSITIVE TAPE SHALL NOT BE USED A5 A <br />PRIMARY SEALANT, PROVIDE A SEAL AGAINST BOTH POSITIVE AND NEGATIVE PRESSURES. <br />G. ALL AIR -HANDLING DUCT SHALL BE THERMALLY INSULATED TO MINIMUM R-G. RECTANGULAR DUCT MAY BE SHEET <br />METAL OR I " FIBERGLASS, CLA55 I DUCT BOARD, L15TED PER UL 16 1 . ROUND DUCT MAY BE SHEET METAL OR <br />FLEXIBLE FIBERGLA55. FLEXIBLE DUCT 5HALL NOT BE USED AS AN ELBOW, FLEXIBLE DUCT SHALL NOT EXCEED 4' <br />IN LENGTH. ALL DUCT SHALL BE INSTALLED FEK'5MACNA' 5TANDARD5 AND MANUFACTURER'S <br />RECOMMENDATIONS. TURNING VANES SHALL BE PROVIDED IN ALL RECTANGULAR DUCT ELBOWS. <br />H. RUNOUT DUCT SIZES SHALL BE SAME SIZE ROUND DUCT AS DIFFUSER NECK 51ZE UNLESS INDICATED <br />OTHERWISE. <br />I. ALL FIELD INSTALLED ELECTRICAL WIRING SHALL BE STRANDED COPPER CONDUCTORS WITH 75 DEG C. <br />WATER-RESISTANT INSULATION, AND BE INSTALLED PER THE LATEST EDITION OF NFPA 70. <br />J. CONTRACTOR SHALL PERFORM IN -PLACE, FULL FUNCTIONAL TESTS OF ALL MECHANICAL SYSTEMS, EQUIPMENT, <br />FIXTURES AND APPLIANCES: AND THESE MECHANICAL SYSTEMS SHALL BE MADE TO OPERATE PER <br />MANUFACTURER'S SPECIFICATIONS PRIOR TO JOB COMPLETION. <br />K. ALL ABANDONED DUCTWORK SHALL BE REMOVED FROM SITE. <br />® MECHANICAL KEYN OTE5 <br />1. INSTALL ACCUREX MODEL XO TYPE II OVEN HOOD, 48"W X 481 X 24"H. HOOD FURNISHED BY OWNER. MOUNT AT <br />7-2" A.F.F. FABRICATE AND INSTALL BRACKETS REQUIRED TO MOUNT HOOD. ROUTE DUCT VERTICALLY. <br />COORDINATE EXHAUST DUCT ROUTING WITH BUILDING STRUCTURE, WATER PIPING, AND ELECTRICAL CONDUITS. <br />l e% ��p' •GEN <br />`.v•.�� S•.c�o <br />�Ir ; • ,k <br />to A E U , <br />✓, 1 <br />STIPULATION FOR REUSE <br />THI5 DRAWING WAS SPECIFICALLY <br />PREPARED FOR USE IN REGAP.D5 TO THE <br />PERMITTING AND CONSTRUCTION OF THI5 <br />PROJECT AND 15 NOT SUITABLE FOR USE <br />FOR ANY OTHER PROJECT. USE OF THIS <br />DRAWING FOR REFERENCE OR EXAMPLE <br />ON ANOTHER PROJECT REQUIRE5 THE <br />5EPVICI-5 OF PROPERLY LICENSED <br />ARCHITECTS AND ENGINEERS. <br />REPRODUCTION OF THIS DRAWING FOR <br />REUSE ON ANOTHER PROJECT 15 NOT <br />AUTHORIZED AND MAY BE CONTRARY TO <br />THE LAW. <br />2. <br />1 4/ 1 0 EXHAUST DUCT UP TO 51DEWALL EXHAUST FAN EF- I . MAINTAIN 1 0'-0" MIN TO RTU AIR INTAKE. PROVIDE <br />so <br />N <br />AND INSTALL BACKDRAFT DAMPER. ADJUST FAN AIRFLOW PER EXHAUST FAN SCHEDULE. <br />° <br />5 <br />n <br />N <br />m <br />o � <br />3. <br />NOT USED. <br />oo <br />o <br />4, <br />EXISTING FUKNACE(5) IN ATTIC SPACE TO REMAIN. REFER TO SCHEDULE ON SHEET M-2 FOR UNIT INFORMATION. <br />4 <br />N <br />MAINTAIN MANUAL OUTSIDE AIR DAMPER AND REBALANCE TO CFM INDICATED IN BUILDING AIR BALANCE <br />SCHEDULE ON DRAWING M-2. <br />� <br />y <br />y <br />5. <br />EXISTING THERM05TAT(5) TO REMAIN. RELOCATE A5 REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. <br />z <br />z <br />z <br />W <br />W <br />LJ <br />O N <br />N <br />G. <br />NOT USED. <br />o <br />7. <br />EXISTING SUPPLY AIR DIFFUSER TO REMAIN. <br />Fn <br />m <br />0 <br />0 <br />0 <br />o� <br />o <br />8. <br />NOT USED. <br />Lu <br />L <br />a <br />N <br />9. <br />NOT USED. <br />'cl <br />� <br />Lu <br />'z <br />z <br />o <br />O <br />O <br />O <br />N L <br />10. <br />EXISTING RETURN AIR GRILLE TO REMAIN. <br />O <br />�`o <br />z <br />1 1. NOT USED. <br />12, <br />NOT USED. <br />13. <br />EXISTING RE5TROOM EXHAUST FAN TO REMAIN. <br />Q <br />> <br />m <br />14. <br />EXISTING CONDENSER TO REMAIN. <br />i <br />il— <br />J <br />15, <br />NOT USED. <br />J LL <br />� <br />Q <br />I G. <br />RELOCATE EXISTING EVAPORATOR A5 NECESSARY. FURGE, MODIFY, AND RECHARGE REFRIGERANT LINES A5 <br />z <br />NECESSARY. <br />_ <br />. <br />— ( <br />17. <br />INSTALL VENDOR SUPPLIED EVAPORATOR(5) IN COOLER PER MANUFACTURER'S REQUIREMENTS. <br />U <br />18, <br />INSTALL LINE -SET AND 4-CONDUCTOR CONTROL WIRING FROM GRADE MOUNTED CONDENSING UNIT TO UNIT <br />COOLERS/ MERCHANDISING EQUIPMENT. DOUBLE INSULATE AND PROTECT EXTERIOR LINE -SET USING 2" FOAM <br />W <br />WRAP AND 5CH.40 PVC CONDUIT TO [ROOF / WALL] PENETRATION. [INSTALL LINE -SET THROUGH CHEMICAL CURB <br />N <br />OR SIMILAR ROOF PENETRATION SEALING SYSTEM.] INSULATE BOTH LIQUID AND SUCTION LINES INSIDE BUILDING <br />U51NG I " FOAM WRAP. PROVIDE ADDITIONAL REFRIGERANT WHERE LENGTH OF LINE -SET EXCEEDS FACTORY <br />6858 <br />CHARGE CAPACITY. MAKE FINAL CONNECTIONS, MECHANICAL CONTRACTOR 15 RESPONSIBLE FOR5EALING ALL <br />[ROOF / BUILDING] PENETRATIONS FOR MECHANICAL EQUIPMENT WATERTIGHT, COORDINATE WITH OTHER <br />BLDGNOR <br />TRADES. <br />VEK51ON OR <br />7 5 1 1 9 3 -01 <br />PROJECT ID <br />19. <br />INSTALL CONDENSING UNITS ON EQUIPMENT RAILS ON CONCRETE. CONDENSING UNIT FURNISHED BY OWNER. <br />5CALE 0 <br />4' <br />MAINTAIN MINIMUM REQUIRED CLEARANCES: 3'-0" TO PARAPET WALLS, AND 2'-0" TO ADJACENT UNIT5. <br />20. <br />INSTALL NEW ROOF MOUNTED EQUIPMENT TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA MECHANICAL <br />1/4"= 1-0" <br />CODE SECTION 30 1 . 1 2 REGARDING WIND RESISTANCE. <br />DE51GN TEAM <br />DATE <br />DGNK. <br />F'.MGR. <br />W115 <br />OG.24.2015 <br />RVWR. <br />W115 <br />DRWG. NO. <br />0-M- <br />