My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7320 Gall Blvd (6)
Zephyrhills
>
Building Department
>
Building Plans
>
7320 Gall Blvd (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 2:17:57 PM
Creation date
1/21/2025 3:42:08 PM
Metadata
Fields
Template:
Building Plans
Street #
7320
Location
Gall Blvd
Contractor
Barr Architectural Studio
Building Plans - Permit #
11371
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IL1 <br />T. I I , . I . .,I I-_ - 11 it <br />Prof. Mgr. <br />DZZ <br />0 <br />1) <br />1) <br />GENERAL ELECTRICAL NOTES <br />1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL <br />CODE (N.E.C. 2008) AND GOVERNING MUNICIPAL, STATE AND LOCAL CODES. ALL <br />MATERIAL SHALL BE NEW AND SHALL BEAR THE U.L. LABEL WHERE APPLICABLE. <br />2. CONTRACTOR SHALL MAKE ALL NECESSARY CUTTING AND DO ALL THE <br />REPATCHING AS NECESSARY FOR THE PROPER EXECUTION OF THIS WORK. <br />3. AFTER COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL TEST FREE FROM <br />SHORT CIRCUITS AND GROUNDS. <br />4. WHERE ELECTRICAL CONDUCTORS ARE INSTALLED IN CONDUIT, THE CONDUIT <br />SHALL COMPLY WITH THE N.E.C. REQUIREMENTS. <br />5. ALL CONDUCTORS SHALL BE COPPER. NO CONDUCTOR SHALL BE SMALLER <br />THAN #12 AWG AND SHALL BE RATED FOR 600VOLTS THWN OR THHN <br />INSULATION. INSTALL A GROUNDING CONDUCTOR WITH ALL CIRCUITS, UNLESS <br />NOTED OTHERWISE, SIZED PER N.E.C. 250-122. <br />6. VERIFY BREAKER AND CORRESPONDING WIRE SIZES FOR ALL ELECTRICAL <br />EQUIPMENT. DO NOT ORDER MATERIAL BEFORE VERIFYING BREAKER & WIRE <br />SIZE. REPORT ANY DISCREPANCY IMMEDIATLY TO THE ENGINEER OF RECORD. <br />7. VERIFY AVAILABLE INTERRUPTING CURRENT (AIC) WITH POWER COMPANY. <br />EQUIPMENT AIC RATING MUST BE LARGER THAN THE POWER COMPANY AIC. <br />8- SAFETY SWITCHES SHALL BE SQUARE 'D', GENERAL ELECTRIC, OR <br />WESTINGHOUSE, FUSED OR NON —FUSED AND SIZED AS INDICATED. NEMA 3R <br />WHEN EXPOSED TO WEATHER <br />9. PANELS SHALL BE SQUARE 'D', GENERAL ELECTRIC OR EQUAL, TYPE AND <br />NUMBER OF BREAKERS AS INDICATED ON PANEL SCHEDULE. STENCIL PANEL <br />DESIGNATION ON INSIDE OF PANEL. ALL TWO —POLE BREAKERS SHALL BE <br />COMMON TRIP. PROVIDE TYPE WRITTEN SCHEDULE IN EACH LOAD CENTERS. <br />CONNECTION TO MAIN BUS SHALL BE WITH BURNDY ANNULAR COMPRESSION <br />LUGS. <br />10. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE ANCHORED TO COMPLY WITH <br />LOCAL CODE FOR WIND RESISTANCE. <br />11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF <br />CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL <br />ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS <br />NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. <br />12. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN <br />A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE <br />FULLY OPERATIVE AND ACCEPTED BY THE OWNER. <br />13. LOAD DATA IS BASED ON INFORMATION GIVEN ENGINEER AT TIME OF DESIGN. <br />VERIFY ALL EQUIPMENT AND PANEL SIZES BEFORE ORDERING AND BEFORE <br />INSTALLATION. <br />14. ALL ELECTRICAL AND COMMUNICATIONS OUTLETS TO BE AT 15" A.F.F TO <br />BOTTOM OF OUTLET UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES SHALL BE <br />O 42" AFF. TO BOTTOM OF SWITCH. <br />15. SERVICE MUST BE 3' ABOVE MSL, VERIFY AT SITE. <br />16. CONTRACTOR MUST VISIT THE SITE PRIOR TO BID OR CONSTRUCTION TO VERIFY <br />ALL EXISTING CONDITIONS. <br />17. CONTROL FOR LIGHTING TO BE AN ASTRONOMICAL TIME CLOCK. <br />18. WHEN NEW ELECTRIC SERVICE IS BEING INSTALLED, IT IS THE GENERAL <br />CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH FPL/FPL ENGINEERS ON <br />THE SIZE OF THE FPL TRANSFORMER THAT IS REQUIRED TO PROVIDE THE NEW <br />ELECTRIC SERVICE SHOWN ON ELECTRIC PLANS, GC HAS TO INFORM THE OWNER <br />ABOUT ANY EXTRA FPL CHARGES THAT MIGHT OCCUR IN ORDER TO PULL NEW <br />SERVICE. THIS HAS TO BE DONE AS EARLY AS POSSIBLE DURING THE BIDDING <br />PROCESS. <br />19. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCY <br />TO ENGINEER BEFORE BID OR INSTALLATION. CONTRACTOR TO REPLACE ANY <br />EXISTING DEVICE OR COMPONENT THAT IS REUSED IF IT IS NOT FULLY <br />OPERATIONAL. <br />AIC CALCULATIONS <br />AT 800A MAIN <br />L = LENGTH OFCIRCUITTOFAULTIN FT <br />AVAILABLE AIC ATCIRCUIT <br />_ CONSTANT FROM TABLE <br />n= NUMBER OF WIRES PER PHASE <br />C = CONSTANTc * n <br />V = VOLTS <br />F 1-732 * L * I / C * V <br />M=1/(1+F) <br />AIC =1*M <br />20 FT <br />42,000 AMPS <br />28,033 <br />2 <br />56,066 <br />= 208 VOLTS <br />0.125 <br />0.889 <br />37,341 AIVP S <br />THESE CALCULATIONS ARE BASED ON AN ESTIMATED DISTANCE: FROM <br />TRANSFORMER TO 1ST MEANS OF DISCLINNECTAND FEEDER WIRE SIZE.. <br />IF LARGER WIRE IS USED OR THE: DISTANCE (L)IS LESS THAN 20 FEET <br />THEN THE AIC VALUES WILL BE LARGER. CONTACT ENGINEER FOR NEW CALCS. <br />AIC CALCULATIONS <br />AT 800A PANEL <br />L = LENGTH OFCIRCUITTOFAULTIN FT <br />I AVAILABLE AIC AT CIRCU IT <br />c = CONSTANT FROM TABLE <br />n= NUMBER OF WIRES PER PHASE <br />C = CONSTANTc * n <br />V = VOLTS <br />F=1-732*L*I/C*V <br />M =11(1+F) <br />AIC =I*M <br />90 FT <br />37,341 AMPS <br />8,033 <br />2 <br />50,060 <br />208 VOLTS <br />0.499 <br />0.7 <br />2+,909 <br />* THESE CALCULATIONS ARE BASED ON AN ESTIMATED DISTANCE FROM <br />TRANSFORMER TO 1ST MEANS OF DISCONNECTAND FEEDER WIRE SIZE.. <br />IF LARGER WIRE IS USED OR THE: DISTANCE (L)IS LESS THAN 90 FEET <br />THEN THE AIC VALUES WILL BE LARGER. CONTACT ENGINEER FOR NEW CALCS. <br />NOTE: <br />UNDERGROUND <br />CONDUITS TO BE PVC <br />(2) SETS OF <br />600 MCM CU <br />81#1/0 CU GRD <br />IN 3-1/2" CONDUIT EACH <br />(2) SETS OF 600 <br />MCM CU IN 3-1/2" NEMA-3R <br />CONDUIT EACH <br />ELEC. <br />MIN <br />METER MAIN . AIC =42 K <br />FMAIN_1 <br />s0OA <br />DISC <br />1 OF 2 <br />MAIN <br />MDP <br />CT CAN <br />EXISTING <br />800A <br />20F2 <br />1-PHA20V/2E <br />3-PHASE <br />L <br />SAVE -A -LOT <br />120V/208V <br />#2/o CU <br />PHASE <br />(2) SETS OF 600 GROUNDING <br />M <br />MIN <br />MCM CU IN 3-1/2" CONDUCTOR IN <br />AIC = 32 K <br />CONDUIT EACH 3/4" CONDUIT <br />TO POWER E-- <br />UTILITY <br />TRANSFORMER <br />STRUCTURAL C/W <br />STEEL PIPE <br />TWO 5/8" <br />COPPER CLAD <br />GROUND RODS <br />ELECTRICAL RISER DIAGRAM <br />v <br />THERE ARE TWO MAINS <br />TO COMMON AREA GROUPED AT THIS <br />PHONE ROOM OR LOCATION <br />ELECTRICAL PLAN <br />SCALE: 1/16"=1'-0" <br />NO.I REVISIONS /d\ I DATE <br />STORE LOCATION: <br />ZEPHYRHILLS, FL <br />r DRAWING DESCRIPTION: <br />ELECTRICAL SERVICE PLAN <br />Job. Caps~ <br />DZZ <br />Drawn by <br />DZZ <br />Revd by STATE OF FLORIDA <br />RB RONALD BARR, A.I.A. <br />AR 0016160 <br />W ZZ <br />V� 0 ZjZ <br />W <br />ZZZZZ ZWWjtWOXWW56;<Wm <br />WImN<fAa�F—yUWO <br />cc an 0 m W ~ U g U W RY ac <br />N U ;oaP-�i5z�g <br />v—Fv§MZF� <br />0 �FWYo� <br />211: <br />NO0Wm VI�e3EjNyW< <br />© COPYRIGHT 2010 <br />BARR ARCHITECTURAL STUDIO <br />RW31onx <br />CONSULTANTS: <br />BUCHANAN P.E CONSULTING INC. <br />ELECTRICAL' MECHANICAL' PLUMBING <br />EN G /NEE RING <br />6191 W. ATLANTIC BLVD. SUITE #2 <br />MARGATE, FL 33063 <br />Ph: 954-590-3300 Fax: 954-590-2232 <br />Email: mepengineers@aol.com <br />RAJA BUCHANAN FL RE # 48916 <br />CERTIFICATE OF AUTHORIZATION # 8842 <br />DEC 13 2010 <br />0 <br />Cq <br />co <br />o <br />L <br />�O .n N <br />I r <br />N <br />c <br />C <br />c <br />U� <br />O , LD <br />ca <br />AM <br />a= <br />�►� <br />rn <br />ca <br />U <br />M o <br />W <br />c <br />ca <br />E <br />L <br />_ <br />o <br />y »- 00 <br />C: <br /><Omk <br />� � <br />o <br />A,, <br />r <br />N <br />Ln <br />U <br />co <br />BYI _T <br />•m <br />ok <br />770 Cochituate Road <br />Framingham, Massachusetts 01701 <br />PLANNED BY- <br />C—SET BY: <br />CHECKED BY: <br />SCALE: 1 /16" = 1'-0" <br />DATE: 12/10/10 <br />STORE TYPE <br />DB 1180A E-1 <br />MA%MVO Na. <br />J <br />LL <br />w <br />N <br />
The URL can be used to link to this page
Your browser does not support the video tag.