Laserfiche WebLink
L <br />10 <br />GENERAL PLUMBING NOTES <br />PLUMBING FIXTURES SHALL COMPLY WITH (F.B.C. 2007 PLUMBING TABLE 604.4) <br />A WATER HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK - CLOSING VALVES <br />ARE UTILIZED, UNLESS OTHERWISE APPROVED. THE ARRESTOR SHALL BE LOCATED <br />DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. REFER TO ARCHITECTURAL <br />WITHIN AN EFFECTIVE RANGE OF THE QUICK - CLOSING VALVE. ACCESS SHALL BE <br />PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, EQUIPMENT, <br />PROVIDED TO WATER HAMMER ARRESTORS. <br />ETC. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED <br />FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION. <br />SHUTOFF VALVE SHALL BE INSTALLED ON THE WATER SUPPLY PIPE TO EACH APPLIANCE <br />OR MECHANICAL EQUIPMENT AS PER (F.B.C. 2007 PLUMBING 606.2.3) <br />ALL WORK AND MATERIALS SHALL COMPLY WITH LATEST EDITIONS OF THE NATIONAL, <br />STATE, AND ALL LOCAL CODES AND ORDINANCES HAVING JURISDICTION. <br />THE DEVELOPED LENGTH OF HOT WATER PIPING FROM THE SOURCE OF HOT WATER <br />SUPPLY TO THE FARTHEST FIXTURE SHALL BE LESS THAN 100 FT. <br />THE PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE <br />THEMSELVES WITH ALL EXISTING CONDITIONS. ALL EXCAVATION AND BACKFILL AS <br />RESTROOMS SHALL COMPLY WITH (F.B.C. 2007 BUILDING SECTION 13-412.1.ABC.2.5.2) <br />REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE PART OF THIS CONTRACT, <br />THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED <br />ALL MATERIALS SHALL BE NEW AND FREE OF NOTICEABLE DEFECTS. <br />ON THE LEFT SIDE OF THE FIXTURE. (F.B.C. 2007 PLUMBING 607.4) <br />ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR AND IN A <br />ALL DEVICES INTENDED TO SERVE SOME SPECIAL FUNCTION AND THAT CONNECT TO THE <br />FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY <br />WATER SUPPLY SYSTEM SHALL BE PROVIDED WITH PROTECTION AGAINST BACKFLOW AND <br />OPERATIVE AND ACCEPTED BY THE ENGINEER/ARCHITECT AS SUCH. <br />CONTAMINATION OF THE WATER SUPPLY SYSTEM. (F.B.C. 2007 PLUMBING 608.3) <br />ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH <br />NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE PURGED OF DELETERIOUS <br />THE PROGRESS OF CONSTRUCTION. <br />MATTER AND, DISINFECTED PRIOR TO UTILIZATION. (F.B.C. 2007 PLUMBING 610.1) <br />VERIFY LOCATION, SIZE AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO THE START <br />OF CONSTRUCTION. IMMEDIATELY ADVISE THE ENGINEER/ARCHITECT OF ANY <br />HOT WATER AND DRAIN PIPES UNDER SINKS AND/OR LAVATORIES SHALL BE INSULATED <br />DISCREPANCIES. ALL EXISTING PLUMBING SHOWN ON THE PLANS IS ESTIMATED AND MAY <br />OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO <br />NOT BE IN THE SAME LOCATION AS SHOWN, CONTRACTOR MUST VERIFY EXISTING <br />SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. (F.B.C. 2007 BUILDING 11-4.19.4 <br />PLUMBING PRIOR TO COMMENCING WORK. <br />& 11-4.24.6) <br />PROVIDE A MINIMUM PITCH OF 1/8' FOR 3" OR LARGER PIPES, 1/4' PITCH FOR LESS <br />THAN 3" PIPES. <br />PROVIDE 1/2" COLD WATER TRAP PRIMER FOR ALL DRAINS FROM THE NEAREST <br />PROVIDE A CLEANOUT AT THE BASE OF EACH SOIL AND WASTE STACK. <br />PLUMBING FIXTURE, WHERE APPLICABLE. <br />PROVIDE MEANS OF RESEALING ALL FLOOR DRAINS. <br />NO HOT WATER WITH A TEMPERATURE HIGHER THAN 140' TO DISCHARGE INTO SANITARY. <br />AN OPEN VENT TERMINAL FROM A DRAIGAGE SYSTEM SHALL NOT BE LOCATED DIRECTLY <br />BENEATH ANY DOOR, OPENABLE WINDOW, OR OTHER AIR INTAKE OPENING OF THE <br />BUILDING OR OF AN ADJACENT BUILDING, AND ANY SUCH VENT TERMINAL SHALL NOT <br />BE WITHIN 10 FEET HORIZONTALLY OF SUCH AN OPENING UNLESS IT IS AT LEAST 2 <br />FEET ABOVE THE TOP OF SUCH OPENING. (F.B.C. 2007 PLUMBING 904.5) <br />NOTES: <br />LANDLORD <br />SHALL USE <br />BEST EFFORTS (I.E. VIDEO) TO CONFIRM <br />THAT THE <br />EXISTING <br />SANITARY <br />SYSTEM ( <br />WHETHER IT <br />IS BEING REUSED OR CONNECTED TO) IS <br />IN GOOD <br />WORKING <br />ORDER. <br />(LINE SHOULD BE CLEAR OF BUT NOT LIMITED TO, <br />THE METERS AND RELATED EQUIPMENT SHALL BE <br />AS DETERMINED BY TENANT. <br />ALL BREAKS, DEBRIS). THE LOCATION OF <br />WITHIN THE DEMISED PREMISES, LOCATION <br />BACKFLOW <br />WATER PREVENTER <br />METER <br />1-1 /2" <br />SHUT—OFF <br />VALVE <br />I � <br />i <br />J <br />CAP AND <br />TERMINATE I �' <br />FOR FUTURE <br />USE. / <br />4" CAP AN <br />TERMINATE <br />FOR FUTURE <br />USE. <br />SHUT—OFF <br />VALVE <br />WATER ISOMETRIC PLAN <br />SCALE: MSC <br />CO <br />�-LCONNECT TO THE EXISTING <br />SEWER LINE, CONTRACTOR <br />TO VERIFY LOCATION ® SITE. <br />CONNECT TO THE EXISTING <br />SFWFR I INF rnNITPAr.TOP <br />WAFER PLAN <br />SCALE: 1/16"=1'-0" <br />Proj. Mgr. <br />DZZ <br />Job. Capt. <br />DZZ <br />Drawn by <br />DZZ <br />Revd by STATE OF FLORIDA <br />RB RONALD BARR, A.I.A. <br />AR 0016160 <br />w <br />F_ z R>. o <br />Uli W OD W z:" z <br />�a cmZ�o <br />w F0 <br /><X a L' 8,W�zw <br />a�b mo�F- <br />ZoFk'ZOmo <br />I�I w� <br />z�w XWz0<=000F�Ftn <br />0LU ��0 W'2(n VoY <br />wm0 MW 'z-Wc�8UWW~O <br />6:cu 0FWjF<FWF'EE Q3 <br />4Ng�o 'g OU_ooc6.>m<z�F <br />a�gV yp�NF-ZQwON7 <br />w0T <� <br />r W0 3oUF�aOzzZiz <br />6W'0< Waooz~ow ovW <br />Maas �M7ow�oD�� <br />p2Um p=Wf l�i?�0X z=a. <br />N_ O W Z N o z z o 2 N W a V 0 <br />��V)iw X<c oi28�p6ia <br />©COPYRIGHT 2010 <br />BARR ARCHITECTURAL STUDIO <br />Revisions: <br />CONSULTANTS: <br />BUCHANAN P.E CONSULTING INC. <br />ELECTRICAL' MECHANICAL' PLUMBING <br />ENGINEERING <br />6191 W. ATLANTIC BLVD. SUITE #2 <br />MARGATE, FL 33063 <br />Ph:954-590-3300 Fax:954-590-2232 <br />Email: mepengineers@aol.com <br />RAJA BUCHANAN FL RE # 48916 <br />CERTIFICATE OF AUTHORIZATION # 8842 <br />DEC 13 2010 <br />h <br />a <br />w <br />;n <br />N ° <br />c <br />.0mN <br />o N c1 <br />L N c <br />N � <br />c� <br />O>N <br />V o 0) <br />,. E <br />E <br />0) <br />M 0 cz <br />W c <br />E <br />_ o <br />�Q. <br />y � L <br />M c <br />Or <br />z CO <br />+- U <br />La-C <br />U <br />i <br />CU <br />NO. REVISIONS DATE BY <br />T •M <br />770 Cochituate Road <br />Framingham, Massachusetts 01701 <br />PLANNED BY: <br />C—SET BY: <br />CHECKED BY: <br />STORE LOCATION: SCALE: 1 /16" = 1'-011 <br />ZEPHYRHILLS, EL DATE: 12/10/10 <br />DRAWING DESCRIPTION: STORE TYPE <br />PLUMBING PLAN DB 1180A P-1 <br />DRAWING No. <br />I <br />LL. <br />